- Manufacturer: FINDER
- Product type: Relay Sockets
- Socket Mounting:Through Hole; Socket Terminals:Quick Connect; No. of Pins:8Pins; Current Rating:12A; Voltage Rating:250V; Product Range:-; SVHC:No SVHC (15-Jan-2019); Accessory Type:Socke
- SVHC: No SVHC (04-Feb-2026)
- No. of Pins: 8Pins
- Product Range: 96 Series
- Current Rating: 12A
- Voltage Rating: 250V
- Socket Mounting: Through Hole
- Socket Terminals: Quick Connect
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 2.19 € |
| Current stock | 100+ |
| Lead time | 30 days |
**56 Series - Miniature power relays 12 A** © ~~fi~~ nder ~~ee~~
**56**
## **Features**
## **56.32**
## **56.32-0300**
## **56.34**
## **Plug-in**
## **12 A Power relay, 2 & 4 pole**
- Flange mount option - (Faston 187, 4.8x0.5 mm termination)
- AC coils & DC coils
- Lockable test button and mechanical flag indicator - standard on 2 pole types
- Cadmium Free contacts (preferred version)
• 2 pole normally open contact (1.5 mm gap)
- 2 pole changeover contact
• 4 pole changeover contact
- Contact material options
- Plug-in/Faston 187
- Plug-in/Faston 187
- Plug-in/Faston 187
- 96 series sockets, coil EMC suppression, accessories
**1 3 2 4 3 4 1 5 2 6 3 7 4 8** WN \ aaa) **5 6 5 6 9 10 11 12 7 8 7 8 13 14** 4h 4h 4h **A1 A2 A1 A2 A1 A2 20.7 27.7 20.7 27.7 41 27.8 10 10 7.25 5.9 8.6 10 10 10** ~~mis | t~~ k ~~i|~~ _e ~~|e .~~ **7.25 5.9 4.753.85 7.25 5.9 4.753.85** For 4 CO (4PDT) only. **Contact specification** Contact configuration 2 CO (DPDT) 2 NO (DPST-NO) - 1.5 mm 4 CO (4PDT) Rated current/Maximum peak current A ~~es~~ 12/20 12/20 12/20 Rated voltage/Maximum switching voltage V AC ~~es~~ 250/400 250/400 250/400 Rated load AC1 VA es 3,000 3,000 3,000 Rated load AC15 (230 V AC) VA es 500 500 500 Single phase motor rating (230 V AC) kW es 0.55 0.55 0.55 Breaking capacity DC1: 30/110/220 V A es 12/0.25/0.12 12/0.6/0.3 12/0.25/0.12 Minimum switching load mW (V/mA) ee 500 (10/5) 500 (10/5) 500 (10/5) Standard contact material AgNi AgNi AgNi **Coil specification** Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400* V DC 6-12-24-48-60-110-125-220 — 6-12-24-48-60-110-125-220 ~~es~~ Rated power AC/DC VA (50 Hz)/W ~~es~~ 1.5/1 1.5/— 2/1.3 Operating range AC es (0.8…1.1)UN (0.85…1.1)UN (0.8…1.1)UN DC es (0.8…1.1)UN — (0.85…1.1)UN Holding voltage AC/DC ee 0.8 UN/0.6 UN 0.85 UN/— 0.8 UN/0.6 UN Must drop-out voltage AC/DC 0.2 UN/0.1 UN 0.2 UN/— 0.2 UN/0.1 UN **Technical data** Mechanical life AC/DC cycles 20 · 10[6] /50 · 10[6] 20 · 10[6] /— 20 · 10[6] /50 · 10[6] Electrical life at rated load AC1 cycles 200 · 10[3] 200 · 10[3] 150 · 10[3] a Operate/release time ms ~~ee~~ 8/8 8/4 8/8 Insulation between coil and contacts (1.2/50 µs) kV ee 4 4 5 Dielectric strength between open contacts V AC ee 1,000 2,000 1,000 Ambient temperature range °C eG –40…+70 –40…+70 –40…+70 Environmental protection RG RT I RT I RT I **Approvals** (according to type) CEP ~~CEO~~ ww GD Ws Kd **75**
- For 4 CO (4PDT) only.
## **56 Series - Miniature power relays 12 A**
## **Features**
**==> picture [27 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
56.42<br>**----- End of picture text -----**<br>
## **56.42-0300**
**==> picture [27 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
56.44<br>**----- End of picture text -----**<br>
## **Printed circuit mount 12 A Power relay**
- 2 & 4 pole
- AC coils & DC coils
- Cadmium Free contacts (preferred version)
- • Contact material option
**==> picture [525 x 623] intentionally omitted <==**
**----- Start of picture text -----**<br>
20.7 27.7 27.7 •<br>• 2 pole normally open contact •<br> 2 pole changeover contact 4 pole changeover contact<br>• PCB mount (1.5 mm gap) • PCB mount<br>• PCB mount<br>10 1 3 2 4 3 4 1 5 2 6 3 7 4 8<br>14.2 a: 7.25 5.9 4.75 3.85 oe 7.25 5.9 8.6<br>56 56.42 56.42-0300<br>nN 5 6 in 5 6 NINA 9 10 11 12<br>7 8 7 8 13 14<br>4H 4h 4h<br>41 27.8 A1 A2 A1 A2 A1 A2<br>20.7 20.7 41<br>L, _. 10 10 10 10 10<br>3.85 3.85<br>1 2 4.75 8.6 1 2 3 4 4.75<br>3 4 5.9 3 4 5.9 5 6 7 8 5.9<br>5 6 7.25 5 6 7.25 9 10 11 12 7.25<br>10 10 10 7 8 7 8 13 14<br>7.25 5.9 4.753.85<br>56.44 + 14.2 4 14.2<br>* For 4 CO (4PDT) only Copper side view Copper side view Copper side view<br>Contact specification<br>Contact configuration 2 CO (DPDT) 2 NO (DPST-NO) 1.5 mm 4 CO (4PDT)<br>Rated current/Maximum peak current A es 12/20 12/20 12/20<br>Rated voltage/Maximum switching voltage V AC es 250/400 250/400 250/400<br>Rated load AC1 VA ee 3,000 3,000 3,000<br>Rated load AC15 (230 V AC) VA ee 500 500 500<br>Single phase motor rating (230 V AC) kW ee 0.55 0.55 0.55<br>Breaking capacity DC1: 30/110/220 V A ee 12/0.25/0.12 12/0.6/0.3 12/0.25/0.12<br>Minimum switching load mW (V/mA) ee 500 (10/5) 500 (10/5) 500 (10/5)<br>Standard contact material AgNi AgNi AgNi<br>Coil specification<br>Nominal voltage (UN) V AC (50/60 Hz) 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*<br>V DC 6-12-24-48-60-110-125-220 — 6-12-24-48-60-110-125-220<br>—<br>Rated power AC/DC VA (50 Hz)/W a 1.5/1 1.5/— 2/1.3<br>Operating range AC es (0.8…1.1)UN (0.85…1.1)UN (0.8…1.1)UN<br>DC a (0.8…1.1)UN — (0.85…1.1)UN<br>Holding voltage AC/DC ee 0.8 UN/0.6 UN 0.85 UN/— 0.8 UN/0.6 UN<br>Must drop-out voltage AC/DC 0.2 UN/0.1 UN 0.2 UN/— 0.2 UN/0.1 UN<br>Technical data<br>Mechanical life AC/DC cycles 20 · 10 [6] /50 · 10 [6] 20 · 10 [6] /— 20 · 10 [6] /50 · 10 [6]<br>Electrical life at rated load AC1 cycles es 200 · 10 [3] 200 · 10 [3] 150 · 10 [3]<br>Operate/release time ms es 8/8 8/4 8/8<br>Insulation between coil and contacts (1.2/50 µs) kV 4 4 5<br>Dielectric strength between open contacts V AC ee 1,000 2,000 1,000<br>Ambient temperature range °C ee =——— –40…+70 –40…+70 –40…+70<br>Environmental protection RT I RT I RT I<br>rs es<br>Approvals (according to type)<br>37.7 36.3<br>6.5 6.5<br>35.2<br>2.5 2.5 2.5<br>6.5 27.7 27.7 27.6<br>**----- End of picture text -----**<br>
**76**
**56 Series - Miniature power relays 12 A**
## **Ordering information**
Example: 56 series plug-in relay, 2 CO (DPDT), 12 V DC coil, lockable test button and mechanical indicator.
**==> picture [352 x 189] intentionally omitted <==**
**----- Start of picture text -----**<br>
A B C D<br>5 6 . 3 2 . 9 . 0 1 2 . 0 0 4 0<br>Series A: Contact material<br>0 = Standard AgNi<br>Type<br>2 = AgCdO<br>3 = Plug-in<br>4 = AgSnO2<br>4 = PCB<br>B: Contact circuit<br>No. of poles<br>0 = CO (nPDT)<br>2 = 2 pole, 12 A<br>3 = NO (nPST),<br>4 = 4 pole, 12 A<br>1.5 mm contact gap 0<br>Coil version 1<br>8 = AC (50/60 Hz) 2<br>9 = DC 3<br>4<br>Coil voltage<br>5<br>see coil specifications<br>**----- End of picture text -----**<br>
## **D: Special versions**
- 0 = Standard
- 5 = Top flange mount (56.34 only) 6 = Rear flange mount 7 = Top 35 mm rail mount (56.34 only)
- 8 = Rear 35 mm rail mount (56.34 only)
## **C: Options**
- 0 = None
- 1 = Test button
- 2 = Mechanical indicator 3 = LED (AC) 4 = Lockable test button+mechanical indicator **56**
- 5 = Lockable test button + LED (AC)
- 54 = Lockable test button + LED (AC) + mechanical indicator
**Selecting features and options: only combinations in the same row are possible.** Preferred selections for best avaliability are shown in **bold.**
- 6 = Double LED (DC non-polarized)
- 7 = Lockable test button + double LED (DC non-polarized)
**==> picture [336 x 283] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Type|Coil version|A|B|C|D|
|56.32|AC|0|- 2 - 4|0|0 - 2 - 3 -|4|- 5|0|- 6|
|AC|0 - 2 - 4|0|54|/|
|AC|0 - 2 - 4|3|0 - 3 - 5|0 - 6|
|DC|0|- 2 - 4|0|0 - 2 -|4|- 8 - 9|0|- 6|
|DC|0 - 2 - 4|0|94|/|
|56.34|AC-DC|0|- 2 - 4|0|0|- 1|0|- 5 - 6 - 7 - 8|
|56.42|AC|0|- 2 - 4|0|- 3|0|0|
|56.44|AC-DC|0|- 2 - 4|0|0|0|
|Descriptions: Options and Special versions|
|A|‘a|"a|
|“a|4|:|
|T|7|i|t|8|il|7|8|F|7|a.|8|‘|
|A1|A2|A1|A2|i)|A1|A2|©|
|C: Option 3, 5, 54|C: Option 6, 7, 74|C: Option 8, 9, 94|D: Special versions 6|
|LED (AC)|Double LED|LED + diode (DC, polarity|Rear flange mount|
|(DC non-polarized)|positive to pin 7)|(56.34 only)|
|3.6|
**----- End of picture text -----**<br>
- 74 = Lockable test button + double LED (DC non-polarized) + mechanical indicator
- 8 = LED + diode (DC, polarity positive to pin 7) 9 = Lockable test button + LED + diode (DC, polarity positive to pin 7)
- 94 = Lockable test button + LED + diode (DC, polarity positive to pin 7) + mechanical indicator
**D: Special versions 8** Rear 35 mm rail mount (56.34 only)
**Lockable test button and mechanical flag indicator (0040)**
The dual-purpose Finder test button can be used in two ways:
Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state.
Case 2) The plastic pip is broken-off (using an appropriate cutting tool). In this case, (in addition to the above function), when the test button is pushed and rotated, the contacts are latched in the operating state, and remain so until the test button is rotated back to its former position. In both cases ensure that the test button actuation is swift and decisive.
**77**
**56 Series - Miniature power relays 12 A**
## **Technical data**
## **Insulation**
**56**
|**Insulation**||||
|---|---|---|---|
|Insulation according to EN 61810-1 ed. 2|insulation rated voltage<br>V|250|400|
||rated impulse withstand voltage<br>kV|4|4|
||pollution degree|3|2|
||overvoltage category|III|III|
|Insulation between coil and contacts (1.2/50µs)<br>kV||4 (2 contacts); 5 (4 contacts)||
|Dielectric strength between open contacts<br>V AC||1,000 (changeover); 2,000 (normallyopen)||
|Dielectric strength between adjacent contacts<br>V AC||2,500||
|**Conducted disturbance immunity**||||
|Burst(5...50)ns, 5 kHz, on A1 - A2||EN 61000-4-4|level 4(4 kV)|
|Surge (1.2/50µs) on A1 - A2 (differential mode)||EN 61000-4-5|level 4 (4 kV)|
|**Other data**||||
|Bounce time: NO/NC<br>ms||1/3(changeover)|3/—(normallyopen)|
|Vibration resistance(5...55)Hz, max. ± 1 mm: NO/NC<br>g/g||15/15||
|Shock resistance|g|16||
|Power lost in the environment|without contact current<br>W|**2pole**|**4pole**|
|||1|1.3|
||with rated current<br>W|3.8|6.9|
|Recommended distance between relays mounted on PCB<br>mm||≥5||
## **Contact specification**
**F 56 - Electrical life (AC) v contact current**
2 pole relays
**==> picture [250 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
107<br>Resistive load - cos ϕ = 1<br>106 Inductive load - cos ϕ = 0.4<br>105<br>0 4 8 12 16<br>(A)<br>Cycles<br>**----- End of picture text -----**<br>
**H 56 - Maximum DC1 breaking capacity** Changeover version
**==> picture [250 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
20<br>10 1 2 3 4 contacts in series<br>6<br>4<br>2<br>1<br>0.2<br>0.1<br>20 60 100 140 180 220<br>DC voltage (V)<br>breaking current (A)<br>DC<br>**----- End of picture text -----**<br>
**F 56 - Electrical life (AC) v contact current**
4 pole relays
**==> picture [251 x 317] intentionally omitted <==**
**----- Start of picture text -----**<br>
107<br>Resistive load - cos ϕ = 1<br>106 Inductive load - cos ϕ = 0.4<br>105<br>0 4 8 12 16<br>(A)<br>H 56 - Maximum DC1 breaking capacity<br>Normally open version<br>20<br>10<br>1 2 contacts in series<br>6<br>4<br>2<br>1<br>0.2<br>0.1<br>20 60 100 140 180 220<br>DC voltage (V)<br>Cycles<br>current (A)<br>breajking<br>DC<br>**----- End of picture text -----**<br>
- When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of ≥ 100·10[3] can be expected.
- In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time of the load will increased.
**78**
**56**
## **56 Series - Miniature power relays 12 A**
## **Coil specifications**
**DC coil data,** 2 pole relay
**==> picture [251 x 139] intentionally omitted <==**
**----- Start of picture text -----**<br>
Nominal Coil Operating range Resistance Rated coil<br>voltage code consumption<br>UN Umin Umax R I at UN<br>V V V Ω mA<br>6 9 .006 4.8 6.6 40 150<br>12 9 .012 9.6 13.2 140 86<br>24 9 .024 19.2 26.4 600 40<br>48 9 .048 38.4 52.8 2,400 20<br>60 9 .060 48 66 4,000 15<br>110 9 .110 88 121 12,500 8.8<br>125 9 .125 100 137.5 17,300 7.2<br>220 9 .220 176 242 54,000 4<br>**----- End of picture text -----**<br>
## **AC coil data,** 2 pole relay
**==> picture [251 x 149] intentionally omitted <==**
**----- Start of picture text -----**<br>
Nominal Coil Operating range Resistance Rated coil<br>voltage code consumption<br>UN Umin* Umax R I at UN (50Hz)<br>V V V Ω mA<br>6 8 .006 4.8 6.6 12 200<br>12 8 .012 9.6 13.2 50 97<br>24 8 .024 19.2 26.4 190 53<br>48 8 .048 38.4 52.8 770 25<br>60 8 .060 48 66 1,200 21<br>110 8 .110 88 121 3,940 12.5<br>120 8 .120 96 132 4,700 12<br>230 8 .230 184 253 17,000 6<br>240 8 .240 192 264 19,100 5.3<br>**----- End of picture text -----**<br>
* Umin = 0.85 UN for normally open version.
## **DC coil data,** 4 pole relay
**==> picture [251 x 137] intentionally omitted <==**
**----- Start of picture text -----**<br>
Nominal Coil Operating range Resistance Rated coil<br>voltage code consumption<br>UN Umin Umax R I at UN<br>V V V Ω mA<br>6 9 .006 5.1 6.6 32.5 185<br>12 9 .012 10.2 13.2 123 97<br>24 9 .024 20.4 26.4 490 49<br>48 9 .048 40.8 52.8 1,800 27<br>60 9 .060 51 66 3,000 20<br>110 9 .110 93.5 121 10,400 10.5<br>125 9 .125 107 137.5 14,200 8.8<br>220 9 .220 187 242 44,000 5<br>**----- End of picture text -----**<br>
**R 56 - DC coil operating range v ambient temperature** 2 pole relay
**==> picture [251 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
U<br>2.0<br>UN<br>1.5<br>1<br>1.0<br>2<br>0.5<br>-20 -10 0 10 20 30 40 50 60 70 80<br>(°C)<br>**----- End of picture text -----**<br>
**R 56 - DC coil operating range v ambient temperature** 4 pole relay
**==> picture [251 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
U<br>2.0<br>UN<br>1.5<br>1<br>1.0<br>2<br>0.5<br>-20 -10 0 10 20 30 40 50 60 70 80<br>(°C)<br>**----- End of picture text -----**<br>
## **AC coil data,** 4 pole relay
**==> picture [251 x 162] intentionally omitted <==**
**----- Start of picture text -----**<br>
Nominal Coil Operating range Resistance Rated coil<br>voltage code consumption<br>UN Umin Umax R I at UN (50Hz)<br>V V V Ω mA<br>6 8 .006 4.8 6.6 5.7 300<br>12 8 .012 9.6 13.2 22 150<br>24 8 .024 19.2 26.4 81 90<br>48 8 .048 38.4 52.8 380 37<br>60 8 .060 48 66 600 30<br>110 8 .110 88 121 1,900 16.5<br>120 8 .120 96 132 2,560 13.4<br>230 8 .230 184 253 7,700 9<br>240 8 .240 192 264 10,000 7.5<br>400 8 .400 320 440 26,000 4.9<br>**----- End of picture text -----**<br>
**R 56 - AC coil operating range v ambient temperature** 2 pole relay
**==> picture [251 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
U<br>2.0<br>UN<br>1.5<br>1<br>1.0 normally open version 2<br>changeover version 2<br>0.5<br>-20 -10 0 10 20 30 40 50 60 70 80<br>(°C)<br>**----- End of picture text -----**<br>
**R 56 - AC coil operating range v ambient temperature** 4 pole relay
**==> picture [251 x 141] intentionally omitted <==**
**----- Start of picture text -----**<br>
U<br>2.0<br>UN<br>1.5<br>1<br>1.0<br>2<br>0.5<br>-20 -10 0 10 20 30 40 50 60 70 80<br>(°C)<br>**----- End of picture text -----**<br>
**1** - Max. permitted coil voltage.
**2** - Min. pick-up voltage with coil at ambient temperature.
**1** - Max. permitted coil voltage.
**2** - Min. pick-up voltage with coil at ambient temperature.
**79**
**56 Series - Miniature power relays 12 A**
**56** 7
## **Accessories**
**==> picture [59 x 77] intentionally omitted <==**
**----- Start of picture text -----**<br>
056.05<br>g<br>056.05 with relay<br>**----- End of picture text -----**<br>
**==> picture [326 x 109] intentionally omitted <==**
**----- Start of picture text -----**<br>
Adaptor with top mount flange for 56.32.x.xxx.xx00 056.05<br>3.6<br>15 2 34.3 1.7<br>UO<br>44.4 37.5<br>**----- End of picture text -----**<br>
**80**
## **96 Series - Sockets and accessories for 56 series relays**
96.72 Approvals (according to type):
99.01 Approvals (according to type):
* Modules in Black housing are available on request.
Green LED is standard. Red LED available on request.
**==> picture [445 x 342] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|Screw terminal (Plate clamp) socket|96.72 (blue)|96.72.0 (black)|96.74 (blue)|96.74.0 (black)|
|panel or 35 mm rail (EN|50022) mount|
|For relay type|56.32|56.34|
|Accessories|
|Metal retaining clip|(supplied with socket - packaging code SMA)|094.71|||096.71|||
|Modules (see table below)|99.01|
|Technical data|
|Rated values|12 A - 250 V|
|Dielectric strength|≥|2 kV AC|
|Protection category|IP|20|
|Ambient temperature|°C|–40…+70|
|Screw torque|Nm|0.8|
|Wire strip length|mm|10|
|Max. wire size for 96.72 and 96.74 sockets|solid wire|stranded wire|
|mm|[2]|1x4 / 2x4|1x4 / 2x2.5|
|AWG|1x12 / 2x12|1x12 / 2x14|
|3.5|3.5|33.5|
|4|4|56|
|22|2|12|1|NC|42|4|32|3|22|2|12|1|NC|
|24|4|14|3|NO|44|8|34|7|24|6|14|5|NO|pp|®|
|21|6|11|5|COM|41|12|31|11|21|10|11|9|COM|
|did|A2|8|A1|7|COIL|fee|d,|3|Whole|A2|14|A1|13|COIL|6.5|||27|
|27|46|30|
|96.72|96.74|
**----- End of picture text -----**<br>
**==> picture [357 x 249] intentionally omitted <==**
**----- Start of picture text -----**<br>
|||||
|---|---|---|---|
|99.01 coil indication and EMC suppression modules|for types 96.72 and 96.74 sockets|
|See technical data pages 247/248|Blue*|
|Diode (+A1, standard polarity)|(6...220)V DC|99.01.3.000.00|
|Diode (+A2, non-standard polarity)|(6...220)V DC|99.01.2.000.00|
|LED|(6...24)V DC/AC|99.01.0.024.59|
|LED|(28...60)V|DC/AC|99.01.0.060.59|
|LED|(110...240)V|DC/AC|99.01.0.230.59|
|LED + Diode (+A1, standard polarity)|(6...24)V DC|99.01.9.024.99|
|LED + Diode (+A1, standard polarity)|(28...60)V|DC|99.01.9.060.99|
|LED + Diode (+A1, standard polarity)|(110...220)V|DC|99.01.9.220.99|
|LED + Diode (+A2, non-standard polarity)|(6...24)V DC|99.01.9.024.79|
|LED + Diode (+A2, non-standard polarity)|(28...60)V|DC|99.01.9.060.79|
|LED + Diode (+A2, non-standard polarity)|(110...220)V|DC|99.01.9.220.79|
|LED + Varistor|(6...24)V|DC/AC|99.01.0.024.98|
|LED + Varistor|(28...60)V|DC/AC|99.01.0.060.98|
|LED + Varistor|(110...240)V DC/AC|99.01.0.230.98|
|RC circuit|(6...24)V DC/AC|99.01.0.024.09|
|RC circuit|(28...60)V DC/AC|99.01.0.060.09|
|RC circuit|(110...240)V|DC/AC|99.01.0.230.09|
|Residual current by-pass (62 kΩ/1W)|(110...240)V AC|99.01.8.230.07|
**----- End of picture text -----**<br>
**81**
**96 Series - Sockets and accessories for 56 series relays**
**==> picture [508 x 719] intentionally omitted <==**
**----- Start of picture text -----**<br>
PCB socket 96.12 (blue) 96.12.0 (black) 96.14 (blue) 96.14.0 (black)<br>For relay type 56.32 56.34<br>Accessories<br>Metal retaining clip (supplied with socket - packaging code SMA) 094.51<br>er | | |<br>Technical data<br>96.12<br>Rated values 15 A - 250 V<br>Approvals<br>(according to type): Dielectric strength ≥ 2 kV AC<br>Protection category IP 20<br>Ambient temperature °C –40…+70<br>21.5<br>cree — 10 21.5 4.5 14.3<br>121 222<br>143 244<br>115 216<br>16.6 11.3<br>A113 A214<br>Copper side view<br>Ly<br>96.12<br>41.5<br>10 10 10 41.5 4.5 14.3<br>121 222 323 424<br>145 246 347 448<br>119 2110 3111 4112<br>A113 A214 32.2 11.3<br>Copper side view4<br>96.14<br>Packaging code<br>How to code and identify retaining clip and packaging options for sockets.<br>Code options according to the last three letters:<br>9 6 . 7 4 S M A<br>A Standard packaging<br>a OO SM Metal retaining clip<br>9 6 . 7 4 Without retaining clip<br>a et<br> 4.7<br>29.5 2.5 5.9 29.5 25<br>6.1<br>2.5 4.7<br>29.5 5.9 29.5 25<br>6.1<br>**----- End of picture text -----**<br>
**56** _
**82**
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →