Image not available
Illustrative purposes only
90/00546800
RTD Sensor, Indoor, Outdoor, Probe, -50 °C, 90 °C, 100 ohm, Platinum
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: JUMO UK LTD
- Product type: RTD Temperature Sensors
- Sensing Temperature Min:-50°C; Sensing Temperature Max:+90°C; Resistance:-; Product Range:-; SVHC:No SVHC (27-Jun-2018); Temperature Sensing Range:-50°C to +90°C
- RTD Type: Probe
- Probe Length: -
- RTD Accuracy: -
- Product Range: -
- Probe Diameter: -
- Probe Material: -
- Cable Termination: -
- Resistance @ 0°C: 100ohm
- Wire Configuration: 2-Wire
- RTD Element Material: Platinum
- Cable Length - Metric: -
- Cable Length - Imperial: -
- Sensing Temperature Max: +90°C
- Sensing Temperature Min: -50°C
- Measured Temperature Max: 90°C
- Measured Temperature Min: -50°C
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 53.41 € |
| Current stock | 10+ |
| Lead time | 30 days |
**JUMO GmbH & Co. KG** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net **JUMO Instrument Co. Ltd.** JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk **JUMO Process Control, Inc.** 8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO 1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us **Data sheet 90.2520 (90.2523) Page 1/7** # **Indoor, outdoor and channel RTD temperature probe** ■ **For temperatures from -50 ... +90 °C (200 °C)** ■ **For application in the air conditioning technology** ■ **Protection class IP20 to IP65** ■ **Connection: in 2-wire, 3-wire or 4-wire circuit** ■ **Available with 4 ... 20 mA or 0 ... 10 V transmitter** Indoor, outdoor and channel RTD temperature probes for air conditioning technology are mainly used for temperature measurement in rooms, in air channels and outdoors. Various device versions made of plastic with different protection classes are available for the respective measuring task. The measuring insert is normally fitted with a Pt 100 temperature probe as per DIN EN 60751, Class B in 2-wire circuit, versions with Pt500, Pt1000 or Ni1000 can also be supplied. From the connection terminals, wiring in 3-wire and 4-wire circuit is also possible. A transmitter can be optionally integrated. ## **Technical Data** **Connection case** **Sheath Measuring insert** **Transmitter** Plastic case PC (basic type 902520/11 material PP), IP20 to IP65, basic type 902524/25 protection class IP54 and IP65 Stainless steel 1.4571; Ø 5.4 mm, Ø 6 mm Pt100 temperature probe, DIN EN 60751, class B, 2-wire circuit Pt1000 temperature probe, DIN EN 60751, class B, 2-wire circuit, For further probes, refer to the order details Analog transmitters, output signal 4 ... 20 mA or 0 ... 10 V 2011-05-20/00311507 ## **JUMO GmbH & Co. KG** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net **JUMO Instrument Co. Ltd.** JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk **JUMO Process Control, Inc.** 8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO 1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us **Data sheet 90.2520 (90.2523) Page 2/7** |**Transmitter**||**Output 4 ... 20 mA**|**Output 0 ... 10 V**| |---|---|---|---| ||**Input**||| ||Measuring input|Pt100 (DIN EN 60751)|| ||Probe current|≤0.5 mA|| ||Measuring range|Permanent measurement due to analog signal path|| ||**Measuring circuit monitoring**||| ||Underrange|dropping to≤3.6 mA|0 V| ||Overrange|increasing to÷22 mA ... < 28 mA (typical<br>24 mA)|increasing to÷11 V... < 14 V<br>(typical 12 V)| ||Probe short-circuit|≤3.6 mA|0 V| ||Probe and wire break|÷22 mA ... < 28 mA (typical 24 mA)|÷11 V... < 14 V (typical 12 V)| ||**Output**||| ||Output signal|load-independent direct current 4 ... 20 mA|Direct current 0 ... 10 V| ||Transmission behavior|temperature linear|| ||Transmission accuracy|≤± 0.1 %|≤± 0.2 %| ||Damping of the residual ripple<br>of a voltage supply of 24 V,<br>amplitude 10 V/50 Hz,<br>burden 470Ω/Load 10MΩ|37 dB|40 dB| ||Burden (Rb)|Rb = (Ub - 7.5 V) / 22 mA|-| ||Burden influence|≤± 0.02 % / 100Ω1|-| ||Load/load influence|-|÷10 kΩ/≤± 0.1 %| ||Setting time for temperature changes|≤10 ms|| ||Adjustment conditions|DC 24 V / approx. 22 °C|| ||Calibration accuracy|≤± 0.2 %1,2or≤± 0.2 K|| ||Overall accuracy, probe/calibration|± 0.4 K (typical) at 20 °C / 24 V voltage supply|| ||**Voltage supply**||| ||Voltage supply (Ub)|DC 7.5 ... 30 V|DC 15 ... 30 V| ||Reverse voltage protection|yes|| ||Voltage supply influence|≤± 0.01 %/V deviation from 24 V1|| ||**Environmental influences**||| ||Operating temperature range|-40 ...+ 85 °C|| ||Storage temperature range|-40 ... +100 °C|| ||Temperature coefficient|≤± 0.01 %/K deviation from 22 °C1|| ||Ambient conditions<br>similar to DIN EN 60654 Kl. C1|relative humidity≤95 % annual average, no condensation|| ||EMC Interference emission/<br>resistance|EN 61326 class B/Industrial requirements|| 1. All specifications referring to the measuring range limit value of 20mA. 2. The higher value is valid. ## **Connection example with power pack, output 4 ... 20 mAConnection example with power pack, output 0 ... 10 V** **==> picture [511 x 196] intentionally omitted <==** **----- Start of picture text -----**<br> Controller Indicator<br>Controller Indicator<br>3-wire<br>transmitter + - + -<br>+<br>2-wiretransmitter - + - + Supply unit7.5 - 30V DC 0 - 10V 0 - 10V<br>+ + - Supply unit<br>- 4 - 20mA - + - 15 - 30V DC N<br>L1<br>+<br>Connection diagram<br>Output 4 - 20mA Output 0 - 10V<br>Connection for Terminal Connection for Terminal<br>Supply voltage + 81 Ub - 7.5V 81 82 Supply voltage + 81 81 82 83<br>7.5 - 30V DC R =B 22mA 15 - 30V DC - 82<br>Load ≥ 10kΩ<br>Current output4 - 20mA - 82 RUBb = burden resistance [= supply voltage] + - Voltage output0 - 10V + 83- 82 + - +<br>83<br>82<br>81<br>**----- End of picture text -----**<br> 2011-05-20/00311507 **JUMO GmbH & Co. KG** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net **JUMO Instrument Co. Ltd.** JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk **JUMO Process Control, Inc.** 8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO 1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us **Data sheet 90.2520 (90.2523) Page 3/7** ## **Dimensions** **==> picture [133 x 229] intentionally omitted <==** **==> picture [334 x 229] intentionally omitted <==** **Basic type 902520/10** **Basic type 902520/11** **Basic type 902520/12** **==> picture [164 x 178] intentionally omitted <==** **==> picture [121 x 229] intentionally omitted <==** **==> picture [162 x 230] intentionally omitted <==** **Basic type 902520/13** **Basic type 902520/15** **Basic type 902524/20** 2011-05-20/00311507 ## **JUMO GmbH & Co. KG** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net **JUMO Instrument Co. Ltd.** JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk **JUMO Process Control, Inc.** 8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO 1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us **==> picture [119 x 43] intentionally omitted <==** **Data sheet 90.2520 (90.2523)** **Page 4/7** **==> picture [162 x 226] intentionally omitted <==** **Basic type 902524/25** 2011-05-20/00311507 **JUMO GmbH & Co. KG** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net **JUMO Instrument Co. Ltd.** JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk **JUMO Process Control, Inc.** 8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO 1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us **Data sheet 90.2520 (90.2523) Page 5/7** ## **Order details: Indoor and outdoor RTD temperature probe** ||||||**(1) Basic type**|**(1) Basic type**|**(1) Basic type**|||||||||**(5)**<br>,...1<br>000| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |x<br>x<br>x<br>x<br>x <br>x <br>x <br>x<br>x <br>x<br>x<br>x <br>x<br>x|||||902520/10<br>Indoor RTD temperature probe<br>Protection class IP20|||||||||||| |||||||||||||||||| |||||||||||||||||| ||x<br> x <br> x <br> x<br>x <br> x <br> x||||902520/11<br>Indoor and outdoor RTD temperature probe<br>Protection class IP54|||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| |||x <br>x <br>x <br>x <br> x <br> x <br> x <br> x <br> x <br>x <br>x|||902520/12<br>Indoor and outdoor RTD temperature probe<br>Protection class IP65|||||||||||| |||||||||||||||||| |||||||||||||||||| |||||||||||||||||| ||||x<br> x<br> x<br> x<br>x<br> x <br> x <br>x <br> x<br> x <br>x <br>x <br> x <br> x<br> x||902520/13<br>Indoor and outdoor RTD temperature probe<br>with stepped sheath<br>Protection class IP65|||||||||||| |||||||||||||||||| |||||||||||||||||| |||||x<br> x<br> x<br> x<br>x<br>x<br>x<br> x<br> x<br> x<br> x<br>x|902520/15<br>Outdoor RTD temperature probe<br>Protection class IP65|||||||||||| |||||||||||||||||| |||||||||||||||||| ||||||**(2) Operating temperature in °C**<br>361<br>-50 ... +90 °C<br>568<br>-30 ... +60 °C (measuring range only in connection with<br>572<br>-30 ... +80 °C (standard)<br>635<br>-20 ... +80 °C (standard)<br>803<br>0 ... 40 °C (measuring range only in connection with extr<br>807<br>0 ... 60 °C (measuring range only in connection with extr<br>**(3) Measuring insert**<br>1001<br>1x Pt 100 in 3-wire-circuit<br>1003<br>1x Pt 100 in 2-wire circuit<br>1005<br>1x Pt1000 in 2-wire circuit<br>1009<br>1x Ni1000 in 2-wire circuit<br>1619<br>1x KTY 81-110<br>1728<br>1x NTC 1 kOhm<br>2001<br>2x Pt100 in 3-wire-circuit<br>2003<br>2x Pt100 in 2-wire circuit<br>**(4) Tolerance class as per DIN EN 60 751**<br>0<br>Technical data Ni/NTC/KTY<br>1<br>Class B (standard)<br>2<br>Class A (not for basic type 902520/10 in connection with<br>3<br>Class AA (1/3 DIN B) (not for basic type 902520/10 in co<br>**(5) Extra codes**<br>000<br>None<br>330<br>Transmitter analog, output 4 ... 20 mA2(in connection wi<br>333<br>Transmitter analog, output 0 ... 10 V2(in connection with<br>903<br>Cable screw-connection (IP65)|||||||||||| |**Order**<br>**Order**|||**code**<br>**example**|||**(1)**<br>-<br>902520/10<br>-|**(2)**<br>-<br>572<br>-|||||||||| > 1 List extra codes in sequence, separated by commas. > 2 Specify measuring range in plain text. 2011-05-20/00311507 **JUMO GmbH & Co. KG** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net **JUMO Instrument Co. Ltd.** JUMO House Temple Bank, Riverway Harlow, Essex CM20 2DY, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk **JUMO Process Control, Inc.** 8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO 1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us **Data sheet 90.2520 (90.2523) Page 6/7** ## **Order details: Channel RTD temperature probe** |||**(1) **|**Basic type**<br>Channel RTD temperature probe<br>with stepped sheath<br>Protection class IP65<br>Channel RTD temperature probe<br>with plain sheath<br>Protection class IP54<br>**Operating temperature in °C**<br>-50 ... +200 °C (standard)<br>-30 ... +60 °C (measuring range only in connection with extra code 330 or 333)<br>-30 ... +80 °C (standard)<br>0 ... 60 °C (measuring range only in connection with extra code 330 or 333)<br> **Measuring insert**<br>1x Pt 100 in 2-wire circuit<br>1x Pt1000 in 2-wire circuit<br>1x Ni1000 in 2-wire circuit<br>2x Pt100 in 2-wire circuit<br> **Tolerance class as per DIN EN 60 751**<br>Class B (standard)<br>Class A<br>Class AA (1/3 DIN B)<br> **Sheath diameter D in mm**<br>Ø 6 mm (for basic type 902524/20 Ø 6 mm stepped down to Ø 3.3 mm)<br> **Nominal length NL in mm (NL 50 ... 500)**<br>100 mm<br>150 mm<br>200 mm<br>Please specify in plain text (50 mm steps)<br> **Process connection**<br>None<br>Sheath screw-connection G 1/4<br>Sheath screw-connection G 1/2<br>Stop flange Ø 6 mm<br> **Extra codes**<br>None<br>Sheath Ø 6 mm stepped down to Ø 3.3 mm<br>Transmitter analog, output 4 ... 20 mA2(in connection with 1x Pt100)<br>Transmitter analog, output 0 ... 10 V2(in connection with 1x Pt100)<br>Protection class IP65<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>-<br>902524/20<br>-<br>572<br>-<br>1003<br>-<br>1<br>-<br>6<br>-<br>100|**Basic type**<br>Channel RTD temperature probe<br>with stepped sheath<br>Protection class IP65<br>Channel RTD temperature probe<br>with plain sheath<br>Protection class IP54<br>**Operating temperature in °C**<br>-50 ... +200 °C (standard)<br>-30 ... +60 °C (measuring range only in connection with extra code 330 or 333)<br>-30 ... +80 °C (standard)<br>0 ... 60 °C (measuring range only in connection with extra code 330 or 333)<br> **Measuring insert**<br>1x Pt 100 in 2-wire circuit<br>1x Pt1000 in 2-wire circuit<br>1x Ni1000 in 2-wire circuit<br>2x Pt100 in 2-wire circuit<br> **Tolerance class as per DIN EN 60 751**<br>Class B (standard)<br>Class A<br>Class AA (1/3 DIN B)<br> **Sheath diameter D in mm**<br>Ø 6 mm (for basic type 902524/20 Ø 6 mm stepped down to Ø 3.3 mm)<br> **Nominal length NL in mm (NL 50 ... 500)**<br>100 mm<br>150 mm<br>200 mm<br>Please specify in plain text (50 mm steps)<br> **Process connection**<br>None<br>Sheath screw-connection G 1/4<br>Sheath screw-connection G 1/2<br>Stop flange Ø 6 mm<br> **Extra codes**<br>None<br>Sheath Ø 6 mm stepped down to Ø 3.3 mm<br>Transmitter analog, output 4 ... 20 mA2(in connection with 1x Pt100)<br>Transmitter analog, output 0 ... 10 V2(in connection with 1x Pt100)<br>Protection class IP65<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>-<br>902524/20<br>-<br>572<br>-<br>1003<br>-<br>1<br>-<br>6<br>-<br>100|**Basic type**<br>Channel RTD temperature probe<br>with stepped sheath<br>Protection class IP65<br>Channel RTD temperature probe<br>with plain sheath<br>Protection class IP54<br>**Operating temperature in °C**<br>-50 ... +200 °C (standard)<br>-30 ... +60 °C (measuring range only in connection with extra code 330 or 333)<br>-30 ... +80 °C (standard)<br>0 ... 60 °C (measuring range only in connection with extra code 330 or 333)<br> **Measuring insert**<br>1x Pt 100 in 2-wire circuit<br>1x Pt1000 in 2-wire circuit<br>1x Ni1000 in 2-wire circuit<br>2x Pt100 in 2-wire circuit<br> **Tolerance class as per DIN EN 60 751**<br>Class B (standard)<br>Class A<br>Class AA (1/3 DIN B)<br> **Sheath diameter D in mm**<br>Ø 6 mm (for basic type 902524/20 Ø 6 mm stepped down to Ø 3.3 mm)<br> **Nominal length NL in mm (NL 50 ... 500)**<br>100 mm<br>150 mm<br>200 mm<br>Please specify in plain text (50 mm steps)<br> **Process connection**<br>None<br>Sheath screw-connection G 1/4<br>Sheath screw-connection G 1/2<br>Stop flange Ø 6 mm<br> **Extra codes**<br>None<br>Sheath Ø 6 mm stepped down to Ø 3.3 mm<br>Transmitter analog, output 4 ... 20 mA2(in connection with 1x Pt100)<br>Transmitter analog, output 0 ... 10 V2(in connection with 1x Pt100)<br>Protection class IP65<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>-<br>902524/20<br>-<br>572<br>-<br>1003<br>-<br>1<br>-<br>6<br>-<br>100|||||||**(7)**<br>/<br>252<br>/|**(8)**<br>,...1<br>000| |---|---|---|---|---|---|---|---|---|---|---|---|---|---| |x<br>x<br>x<br>x <br>x <br>x <br>x<br>x <br>x <br>x<br>x <br>x <br>x <br>x <br>x <br>x <br>x <br>x<br>x||902524/20|Channel RTD temperature probe<br>with stepped sheath<br>Protection class IP65||||||||||| ||||||||||||||| ||||||||||||||| ||||||||||||||| ||x<br> x<br> x<br> x<br> x<br> x<br> x<br> x<br>x<br>x<br>x<br> x<br> x<br> x<br> x<br> x<br>x<br>x|902524/25|Channel RTD temperature probe<br>with plain sheath<br>Protection class IP54||||||||||| ||||||||||||||| ||||||||||||||| |||(2)<br>380<br>568<br>572<br>807<br>**(3) **<br>1003<br>1005<br>1009<br>2003<br>**(4) **<br>1<br>2<br>3<br>**(5) **<br>6<br>**(6) **<br>100<br>150<br>200<br>...<br>**(7) **<br>000<br>252<br>254<br>662<br>**(8) **<br>000<br>310<br>330<br>333<br>404|**Operating temperature in °C**<br>-50 ... +200 °C (standard)<br>-30 ... +60 °C (measuring range only in connection with<br>-30 ... +80 °C (standard)<br>0 ... 60 °C (measuring range only in connection with ext<br> **Measuring insert**<br>1x Pt 100 in 2-wire circuit<br>1x Pt1000 in 2-wire circuit<br>1x Ni1000 in 2-wire circuit<br>2x Pt100 in 2-wire circuit<br> **Tolerance class as per DIN EN 60 751**<br>Class B (standard)<br>Class A<br>Class AA (1/3 DIN B)<br> **Sheath diameter D in mm**<br>Ø 6 mm (for basic type 902524/20 Ø 6 mm stepped do<br> **Nominal length NL in mm (NL 50 ... 500)**<br>100 mm<br>150 mm<br>200 mm<br>Please specify in plain text (50 mm steps)<br> **Process connection**<br>None<br>Sheath screw-connection G 1/4<br>Sheath screw-connection G 1/2<br>Stop flange Ø 6 mm<br> **Extra codes**<br>None<br>Sheath Ø 6 mm stepped down to Ø 3.3 mm<br>Transmitter analog, output 4 ... 20 mA2(in connection w<br>Transmitter analog, output 0 ... 10 V2(in connection wit<br>Protection class IP65||||||||-<br>-||| |**Order code**<br>**Order example**|||**(1)**<br>-<br>902524/20<br>-|**(2)**<br>-<br>572<br>-|**(3)**<br>-<br>1003<br>-||||||||| ||||||||||||||| |||||||||||100|||| > 1 List extra codes in sequence, separated by commas. > 2 Specify measuring range in plain text. 2011-05-20/00311507 **Data sheet 90.2520 (90.2523) Page 7/7** **JUMO GmbH & Co. KG JUMO Instrument Co. Ltd.** Delivery address:Mackenrodtstraße 14, JUMO House 36039 Fulda, Germany Temple Bank, Riverway Postal address: 36035 Fulda, Germany Harlow, Essex CM20 2DY, UK Phone: +49 661 6003-0 Phone: +44 1279 635533 Fax: +49 661 6003-607 Fax: +44 1279 635262 e-mail: mail@jumo.net e-mail: sales@jumo.co.uk Internet: www.jumo.net Internet: www.jumo.co.uk **JUMO Process Control, Inc.** 8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO 1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us **==> picture [119 x 43] intentionally omitted <==** ## **Stock versions** |**Stock versions**|| |---|---| |**Order code**|**Part No.**| |902520/10-572-1001-1/000|90/00065671| |902520/10-572-1005-1/000|90/00397862| |902520/10-803-1003-1/330 (0 to 40 °C)|90/00064003| |902520/10-807-1003-1/330 (0 to 60 °C)|90/00065717| |902520/10-803-1003-1/333 (0 to 40 °C)|90/00439187| |902520/11-635-1003-1/000|90/00055723| |902520/12-572-1003-1/000|90/00064881| |902520/12-572-1005-1/000|90/00350019| |902520/12-807-1003-1/330 (0 to 60 °C)|90/00064883| |902520/13-572-1003-1/000|90/00419733| |902520/13-572-1005-1/000|90/00404301| |902520/13-568-1003-1/330 (-30 to +60 °C)|90/00419736| |902520/13-568-1003-1/333 (-30 to +60 °C)|90/00439195| |902520/15-361-1003-1/000|90/00546799| |902520/15-361-1005-1/000|90/00546802| |902520/15-361-1003-1/903|90/00546800| |902520/15-361-1005-1/903|90/00546801| |902524/20-572-1003-1-6-100-662/000|90/00064894| |902524/20-568-1003-1-6-100-662/330 (-30 to +60 °C)|90/00065087| |902524/25-380-1003-1-6-100-000/310,404|90/00410556| |902524/25-380-1003-1-6-150-000/310,404|90/00410562| |902524/25-380-1003-1-6-200-000/310,404|90/00410563| 2011-05-20/00311507
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →