Image not available
Illustrative purposes only
90/00065671
RTD Sensor, Indoor, Outdoor, Component, -30 °C, 80 °C, 100 ohm, Platinum
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: JUMO UK LTD
- Product type: RTD Temperature Sensors
- Sensing Temperature Min:-30°C; Sensing Temperature Max:+80°C; Resistance:100ohm; Product Range:-; SVHC:No SVHC (27-Jun-2018); Temperature Sensing Range:-30°C to +80°C
- RTD Type: Component
- Resistance: 100ohm
- Probe Length: -
- RTD Accuracy: -
- Product Range: -
- Probe Diameter: -
- Probe Material: -
- Cable Termination: -
- Resistance @ 0°C: 100ohm
- Wire Configuration: 3-Wire
- RTD Element Material: Platinum
- Cable Length - Metric: -
- Cable Length - Imperial: -
- Sensing Temperature Max: +80°C
- Sensing Temperature Min: -30°C
- Measured Temperature Max: 80°C
- Measured Temperature Min: -30°C
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 107.34 € |
| Current stock | 10+ |
| Lead time | 30 days |
Internet: www.JumoUSA.com ## **M. K. JUCHHEIM GmbH & Co** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net ## **JUMO Instrument Co. Ltd.** JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk ## **JUMO PROCESS CONTROL INC.** 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-mail: info@JumoUSA.com ## ~~ee~~ **Data Sheet 90.2523 Page 1/6** # **Indoor, outdoor and duct resistance thermometers** ■ **for temperatures from -30 to +80°C (200°C)** ■ **for use in HVAC** ■ **IP20 to IP65 protection** ■ **for 2-wire, 3-wire or 4-wire connections** ■ **fitted transmitter option 4 – 20mA / 0 – 10V** Indoor, outdoor and duct resistance thermometers for HVAC applications are mainly used for temperature measurement in rooms, air ducts and outdoors. Different instrument versions with plastic housings for different protection ratings are available to suit the particular measurement task. The measuring insert is normally fitted with a Pt100 temperature sensor to EN 60751, Class B, in 2-wire circuit. Versions with Pt500, Pt1000 or Ni 1000 can also be supplied. An extension in 3- or 4-wire circuit, starting from the terminals, is possible. A transmitter can optionally be integrated. ## **Technical data** **Terminal box** **Protection tube Measuring insert Transmitter** plastic PC housing (material PP on Type 902523/11), IP20 to IP65, Type 902523/25: IP54 and IP65 protection stainless steel 1.4571; 5.4mm and 6mm dia. Pt100 temperature sensor, EN 60 751, Class B, 2-wire circuit analog transmitter, output signal 4 – 20mA or 0 – 10V 02.03/00311507 ## **M. K. JUCHHEIM GmbH & Co** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net ## **JUMO Instrument Co. Ltd.** JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk ## **JUMO PROCESS CONTROL INC.** 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-mail: info@JumoUSA.com Internet: www.JumoUSA.com **==> picture [119 x 43] intentionally omitted <==** ## **Data Sheet 90.2523** ## **Page 2/6** |**Transmitter**||**Output 4 – 20mA**|**Output 0 – 10V**| |---|---|---|---| ||**Input**||| ||Measurement input|Pt100 (EN 60 751)|| ||Sensor current|≤0.5mA|| ||Sampling rate|continuous measurement because of analog signal path|| ||**Measurement circuit monitoring**||| ||Underrange|falling to≤3.6mA|0V| ||Overrange|rising to≥22mA to < 28mA<br>(24mA typical)|rising to≥11V to < 14V<br>(12V typical)| ||Probe short circuit|≤3.6mA|0V| ||Probe and lead break|≥22mA to < 28mA (24mA typical)|≥11V to < 14V (12V typical)| ||**Output**||| ||Output signal|proportional DC current 4 – 20mA|DC voltage 0 – 10V| ||Transfer characteristic|linear with temperature|| ||Transfer accuracy|≤±0.1%|≤±0.2%| ||Damping of ripple on<br>24V supply voltage,<br>amplitude 10V/50Hz,<br>burden 470Ω/load 10MΩ|37dB|40dB| ||Burden (Rb)|Rb = (Ub - 7.5V) / 22mA|-| ||Burden error|≤±0.02% / 100Ω1|-| ||Load/load error|-|≥10kΩ/≤±0.1%| ||Settling time on temperature change|≤10msec|| ||Calibration conditions|24V DC / approx. 22°C|| ||Calibration accuracy|≤±0.2%1,2or≤±0.2°C|| ||Overall accuracy: sensor/calibration|±0.4°C (typical) at 20°C / 24V supply voltage|| ||**Supply**||| ||Supply voltage (Ub)|7.5 – 30V DC|15 – 30V DC| ||Reverse polarity protection|yes|| ||Supply voltage error|≤±0.01% per V deviation from 24V1|| ||**Ambient conditions**||| ||Operating temperature range|-40 to +85°C|| ||Storage temperature range|-40 to +100°C|| ||Temperature error|≤±0.01% per °C deviation from 22°C1|| ||Climatic conditions<br>similar to EN 60 654, Class C1|relative humidity≤95% annual mean, no condensation|| ||EMC interference emission/immunity|EN 61 326, Class B / to industrial requirements|| 1. All data refer to the end-of-range value 20mA. 2. The larger value applies. ## **Connection example with supply unit, 4 – 20mA output Connection example with supply unit, 0 – 10V output** **==> picture [415 x 105] intentionally omitted <==** **----- Start of picture text -----**<br> Controller Indicator<br>Controller Indicator<br>3-wire<br>transmitter + - + -<br>+<br>2-wiretransmitter - + - + Supply unit7.5 - 30V DC 0 - 10V 0 - 10V<br>+ + - Supply unit<br>- 4 - 20mA - + - 15 - 30V DC N<br>L1<br>+<br>**----- End of picture text -----**<br> ## **Connection diagram** ## **Output 4 - 20mA** **Output 0 - 10V** **==> picture [509 x 71] intentionally omitted <==** **----- Start of picture text -----**<br> Connection for Terminal Connection for Terminal<br>Supply voltage + 81 Ub - 7.5V 81 82 Supply voltage + 81 81 82 83<br>7.5 - 30V DC R =B 22mA 15 - 30V DC - 82<br>Load ≥ 10kΩ<br>Current output4 - 20mA - 82 URBb = burden resistance [= supply voltage] + - Voltage output0 - 10V + 83- 82 + - +<br>83<br>82<br>81<br>**----- End of picture text -----**<br> 02.03/00311507 **JUMO PROCESS CONTROL INC.** **JUMO Instrument Co. Ltd.** ## **M. K. JUCHHEIM GmbH & Co** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-mail: info@JumoUSA.com Internet: www.JumoUSA.com **==> picture [119 x 43] intentionally omitted <==** **Data Sheet 90.2523 Page 3/6** ## **Dimensions** **==> picture [133 x 229] intentionally omitted <==** **==> picture [334 x 229] intentionally omitted <==** **Type 902523/10** **Type 902523/11** **==> picture [334 x 229] intentionally omitted <==** ## **Type 902523/12** **==> picture [164 x 227] intentionally omitted <==** **----- Start of picture text -----**<br> approx. 52<br>**----- End of picture text -----**<br> **Type 902523/13** **==> picture [74 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Type 902523/20<br>**----- End of picture text -----**<br> **==> picture [74 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> Type 902523/25<br>**----- End of picture text -----**<br> 02.03/00311507 **M. K. JUCHHEIM GmbH & Co** **JUMO PROCESS CONTROL INC.** **JUMO Instrument Co. Ltd.** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-mail: info@JumoUSA.com Internet: www.JumoUSA.com **==> picture [119 x 43] intentionally omitted <==** **Data Sheet 90.2523** **Page 4/6** ## **Order details: Indoor, outdoor and duct resistance thermometers** |||||**(1) **|**Basic version**<br>Indoor resistance thermometer,<br>Protection IP20<br>Indoor and outdoor<br>resistance thermometer,<br>Protection IP54<br>Indoor and outdoor<br>resistance thermometer,<br>Protection IP65<br>Indoor and outdoor<br>resistance thermometer<br>with stepped protection tube,<br>Protection IP65<br> **Operating temperature in °C**<br>-30 to +60°C (range only in conjunction with extra code 330 or 333)<br>-30 to +80°C (standard)<br>0 to 40°C (range only in conjunction with extra code 330 or 333)<br>0 to 60°C (range only in conjunction with extra code 330 or 333)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt1000 in 2-wire circuit<br>1 x Ni 1000 in 2-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A (not for Type 902523/10 and transmitter)<br>Class 1/3 DIN (not for Type 902523/10 and transmitter)<br> **Extra codes**<br>no extra code<br>analog transmitter, 4 – 20mA output (in conjunction with 1 x Pt100)*<br>analog transmitter, 0 – 10V output (in conjunction with 1 x Pt100)*<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>/<br> ,...<br>902523/10 -<br>572<br>- 1001 -<br>1<br>/<br>0001|**Basic version**<br>Indoor resistance thermometer,<br>Protection IP20<br>Indoor and outdoor<br>resistance thermometer,<br>Protection IP54<br>Indoor and outdoor<br>resistance thermometer,<br>Protection IP65<br>Indoor and outdoor<br>resistance thermometer<br>with stepped protection tube,<br>Protection IP65<br> **Operating temperature in °C**<br>-30 to +60°C (range only in conjunction with extra code 330 or 333)<br>-30 to +80°C (standard)<br>0 to 40°C (range only in conjunction with extra code 330 or 333)<br>0 to 60°C (range only in conjunction with extra code 330 or 333)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt1000 in 2-wire circuit<br>1 x Ni 1000 in 2-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A (not for Type 902523/10 and transmitter)<br>Class 1/3 DIN (not for Type 902523/10 and transmitter)<br> **Extra codes**<br>no extra code<br>analog transmitter, 4 – 20mA output (in conjunction with 1 x Pt100)*<br>analog transmitter, 0 – 10V output (in conjunction with 1 x Pt100)*<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>/<br> ,...<br>902523/10 -<br>572<br>- 1001 -<br>1<br>/<br>0001|**Basic version**<br>Indoor resistance thermometer,<br>Protection IP20<br>Indoor and outdoor<br>resistance thermometer,<br>Protection IP54<br>Indoor and outdoor<br>resistance thermometer,<br>Protection IP65<br>Indoor and outdoor<br>resistance thermometer<br>with stepped protection tube,<br>Protection IP65<br> **Operating temperature in °C**<br>-30 to +60°C (range only in conjunction with extra code 330 or 333)<br>-30 to +80°C (standard)<br>0 to 40°C (range only in conjunction with extra code 330 or 333)<br>0 to 60°C (range only in conjunction with extra code 330 or 333)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt1000 in 2-wire circuit<br>1 x Ni 1000 in 2-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A (not for Type 902523/10 and transmitter)<br>Class 1/3 DIN (not for Type 902523/10 and transmitter)<br> **Extra codes**<br>no extra code<br>analog transmitter, 4 – 20mA output (in conjunction with 1 x Pt100)*<br>analog transmitter, 0 – 10V output (in conjunction with 1 x Pt100)*<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>/<br> ,...<br>902523/10 -<br>572<br>- 1001 -<br>1<br>/<br>0001|**Basic version**<br>Indoor resistance thermometer,<br>Protection IP20<br>Indoor and outdoor<br>resistance thermometer,<br>Protection IP54<br>Indoor and outdoor<br>resistance thermometer,<br>Protection IP65<br>Indoor and outdoor<br>resistance thermometer<br>with stepped protection tube,<br>Protection IP65<br> **Operating temperature in °C**<br>-30 to +60°C (range only in conjunction with extra code 330 or 333)<br>-30 to +80°C (standard)<br>0 to 40°C (range only in conjunction with extra code 330 or 333)<br>0 to 60°C (range only in conjunction with extra code 330 or 333)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt1000 in 2-wire circuit<br>1 x Ni 1000 in 2-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A (not for Type 902523/10 and transmitter)<br>Class 1/3 DIN (not for Type 902523/10 and transmitter)<br> **Extra codes**<br>no extra code<br>analog transmitter, 4 – 20mA output (in conjunction with 1 x Pt100)*<br>analog transmitter, 0 – 10V output (in conjunction with 1 x Pt100)*<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>/<br> ,...<br>902523/10 -<br>572<br>- 1001 -<br>1<br>/<br>0001|**Basic version**<br>Indoor resistance thermometer,<br>Protection IP20<br>Indoor and outdoor<br>resistance thermometer,<br>Protection IP54<br>Indoor and outdoor<br>resistance thermometer,<br>Protection IP65<br>Indoor and outdoor<br>resistance thermometer<br>with stepped protection tube,<br>Protection IP65<br> **Operating temperature in °C**<br>-30 to +60°C (range only in conjunction with extra code 330 or 333)<br>-30 to +80°C (standard)<br>0 to 40°C (range only in conjunction with extra code 330 or 333)<br>0 to 60°C (range only in conjunction with extra code 330 or 333)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt1000 in 2-wire circuit<br>1 x Ni 1000 in 2-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A (not for Type 902523/10 and transmitter)<br>Class 1/3 DIN (not for Type 902523/10 and transmitter)<br> **Extra codes**<br>no extra code<br>analog transmitter, 4 – 20mA output (in conjunction with 1 x Pt100)*<br>analog transmitter, 0 – 10V output (in conjunction with 1 x Pt100)*<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>/<br> ,...<br>902523/10 -<br>572<br>- 1001 -<br>1<br>/<br>0001|||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>x<br>**Order code**||||902523/10|Indoor resistance thermometer,<br>Protection IP20<br>Indoor and outdoor<br>resistance thermometer,<br>Protection IP54<br>Indoor and outdoor<br>resistance thermometer,<br>Protection IP65<br>Indoor and outdoor<br>resistance thermometer<br>with stepped protection tube,<br>Protection IP65<br> **Operating temperature in °C**<br>-30 to +60°C (range only in conjunction with extra code<br>-30 to +80°C (standard)<br>0 to 40°C (range only in conjunction with extra code 33<br>0 to 60°C (range only in conjunction with extra code 33<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt1000 in 2-wire circuit<br>1 x Ni 1000 in 2-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A (not for Type 902523/10 and transmitter)<br>Class 1/3 DIN (not for Type 902523/10 and transmitter)<br> **Extra codes**<br>no extra code<br>analog transmitter, 4 – 20mA output (in conjunction wit<br>analog transmitter, 0 – 10V output (in conjunction with<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>/<br>|||||||||||| |||||||||||||||||| |||||||||||||||||| |||||902523/11||||||||||||| |||||||||||||||||| |||||902523/12||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||902523/13||||||||||||| |||||||||||||||||| |||||||||||||||||| |||||**(2) **<br>568<br>572<br>803<br>807<br>**(3) **<br>1001<br>1003<br>1005<br>1009<br>2001<br>2003<br>**(4) **<br>1<br>2<br>3<br>**(5) **<br>000<br>330<br>333||||||||||||| |||||||||||||||||| |**Order example**|||||902523/10 -|572<br>-|1001 -|1<br>/||||||||| - Please specify range in plain text. - 1.List extra codes in sequence, separated by commas. 02.03/00311507 **M. K. JUCHHEIM GmbH & Co** **JUMO PROCESS CONTROL INC.** **JUMO Instrument Co. Ltd.** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-mail: info@JumoUSA.com Internet: www.JumoUSA.com **==> picture [119 x 43] intentionally omitted <==** **Data Sheet 90.2523** **Page 5/6** ## **Order details: Indoor, outdoor and duct resistance thermometers** |||**(1) **|**Basic version**<br>Duct resistance thermometer<br>with stepped protection tube,<br>Protection IP65<br>Duct resistance thermometer<br>with plain protection tube,<br>Protection IP54<br> **Operating temperature in °C**<br>-50 to +200°C (standard)<br>-30 to +60°C (range only in conjunction with extra code 330 or 333)<br>-30 to +80°C (standard)<br>0 to 60°C (range only in conjunction with extra code 330 or 333)<br> **Measuring insert**<br>1 x Pt100 in 2-wire circuit<br>1 x Pt1000 in 2-wire circuit<br>1 x Ni 1000 in 2-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br>Class 1/3 DIN<br> **Protection tube diameter D in mm**<br>6mm (Type 902523/20: stepped down from 6mm dia. to 3.3mm dia.)<br> **Fitting length EL in mm (50**≤**EL**≤**500)**<br>100mm<br>150mm<br>200mm<br>please specify in plain text (in 50mm steps)<br> **Process connection**<br>no process connection<br>screwed pipe joint G 1/4 (1/4" pipe)<br>screwed pipe joint G 1/2 (1/2" pipe)<br>stop flange 6mm dia.<br> **Extra codes**<br>no extra code<br>protection tube stepped down from 6mm dia. to 3.3mm dia.<br>analog transmitter, 4 – 20mA output (in conjunction with 1 x Pt100)*<br>analog transmitter, 0 – 10V output (in conjunction with 1 x Pt100)*<br>Protection IP65<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>-<br>-<br>902523/20 -<br>572<br>- 1003 -<br>1<br>-<br>6<br>-<br>100<br>-|**Basic version**<br>Duct resistance thermometer<br>with stepped protection tube,<br>Protection IP65<br>Duct resistance thermometer<br>with plain protection tube,<br>Protection IP54<br> **Operating temperature in °C**<br>-50 to +200°C (standard)<br>-30 to +60°C (range only in conjunction with extra code 330 or 333)<br>-30 to +80°C (standard)<br>0 to 60°C (range only in conjunction with extra code 330 or 333)<br> **Measuring insert**<br>1 x Pt100 in 2-wire circuit<br>1 x Pt1000 in 2-wire circuit<br>1 x Ni 1000 in 2-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br>Class 1/3 DIN<br> **Protection tube diameter D in mm**<br>6mm (Type 902523/20: stepped down from 6mm dia. to 3.3mm dia.)<br> **Fitting length EL in mm (50**≤**EL**≤**500)**<br>100mm<br>150mm<br>200mm<br>please specify in plain text (in 50mm steps)<br> **Process connection**<br>no process connection<br>screwed pipe joint G 1/4 (1/4" pipe)<br>screwed pipe joint G 1/2 (1/2" pipe)<br>stop flange 6mm dia.<br> **Extra codes**<br>no extra code<br>protection tube stepped down from 6mm dia. to 3.3mm dia.<br>analog transmitter, 4 – 20mA output (in conjunction with 1 x Pt100)*<br>analog transmitter, 0 – 10V output (in conjunction with 1 x Pt100)*<br>Protection IP65<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>-<br>-<br>902523/20 -<br>572<br>- 1003 -<br>1<br>-<br>6<br>-<br>100<br>-|**Basic version**<br>Duct resistance thermometer<br>with stepped protection tube,<br>Protection IP65<br>Duct resistance thermometer<br>with plain protection tube,<br>Protection IP54<br> **Operating temperature in °C**<br>-50 to +200°C (standard)<br>-30 to +60°C (range only in conjunction with extra code 330 or 333)<br>-30 to +80°C (standard)<br>0 to 60°C (range only in conjunction with extra code 330 or 333)<br> **Measuring insert**<br>1 x Pt100 in 2-wire circuit<br>1 x Pt1000 in 2-wire circuit<br>1 x Ni 1000 in 2-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br>Class 1/3 DIN<br> **Protection tube diameter D in mm**<br>6mm (Type 902523/20: stepped down from 6mm dia. to 3.3mm dia.)<br> **Fitting length EL in mm (50**≤**EL**≤**500)**<br>100mm<br>150mm<br>200mm<br>please specify in plain text (in 50mm steps)<br> **Process connection**<br>no process connection<br>screwed pipe joint G 1/4 (1/4" pipe)<br>screwed pipe joint G 1/2 (1/2" pipe)<br>stop flange 6mm dia.<br> **Extra codes**<br>no extra code<br>protection tube stepped down from 6mm dia. to 3.3mm dia.<br>analog transmitter, 4 – 20mA output (in conjunction with 1 x Pt100)*<br>analog transmitter, 0 – 10V output (in conjunction with 1 x Pt100)*<br>Protection IP65<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>-<br>-<br>902523/20 -<br>572<br>- 1003 -<br>1<br>-<br>6<br>-<br>100<br>-|**Basic version**<br>Duct resistance thermometer<br>with stepped protection tube,<br>Protection IP65<br>Duct resistance thermometer<br>with plain protection tube,<br>Protection IP54<br> **Operating temperature in °C**<br>-50 to +200°C (standard)<br>-30 to +60°C (range only in conjunction with extra code 330 or 333)<br>-30 to +80°C (standard)<br>0 to 60°C (range only in conjunction with extra code 330 or 333)<br> **Measuring insert**<br>1 x Pt100 in 2-wire circuit<br>1 x Pt1000 in 2-wire circuit<br>1 x Ni 1000 in 2-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br>Class 1/3 DIN<br> **Protection tube diameter D in mm**<br>6mm (Type 902523/20: stepped down from 6mm dia. to 3.3mm dia.)<br> **Fitting length EL in mm (50**≤**EL**≤**500)**<br>100mm<br>150mm<br>200mm<br>please specify in plain text (in 50mm steps)<br> **Process connection**<br>no process connection<br>screwed pipe joint G 1/4 (1/4" pipe)<br>screwed pipe joint G 1/2 (1/2" pipe)<br>stop flange 6mm dia.<br> **Extra codes**<br>no extra code<br>protection tube stepped down from 6mm dia. to 3.3mm dia.<br>analog transmitter, 4 – 20mA output (in conjunction with 1 x Pt100)*<br>analog transmitter, 0 – 10V output (in conjunction with 1 x Pt100)*<br>Protection IP65<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>-<br>-<br>902523/20 -<br>572<br>- 1003 -<br>1<br>-<br>6<br>-<br>100<br>-|**Basic version**<br>Duct resistance thermometer<br>with stepped protection tube,<br>Protection IP65<br>Duct resistance thermometer<br>with plain protection tube,<br>Protection IP54<br> **Operating temperature in °C**<br>-50 to +200°C (standard)<br>-30 to +60°C (range only in conjunction with extra code 330 or 333)<br>-30 to +80°C (standard)<br>0 to 60°C (range only in conjunction with extra code 330 or 333)<br> **Measuring insert**<br>1 x Pt100 in 2-wire circuit<br>1 x Pt1000 in 2-wire circuit<br>1 x Ni 1000 in 2-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br>Class 1/3 DIN<br> **Protection tube diameter D in mm**<br>6mm (Type 902523/20: stepped down from 6mm dia. to 3.3mm dia.)<br> **Fitting length EL in mm (50**≤**EL**≤**500)**<br>100mm<br>150mm<br>200mm<br>please specify in plain text (in 50mm steps)<br> **Process connection**<br>no process connection<br>screwed pipe joint G 1/4 (1/4" pipe)<br>screwed pipe joint G 1/2 (1/2" pipe)<br>stop flange 6mm dia.<br> **Extra codes**<br>no extra code<br>protection tube stepped down from 6mm dia. to 3.3mm dia.<br>analog transmitter, 4 – 20mA output (in conjunction with 1 x Pt100)*<br>analog transmitter, 0 – 10V output (in conjunction with 1 x Pt100)*<br>Protection IP65<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>-<br>-<br>902523/20 -<br>572<br>- 1003 -<br>1<br>-<br>6<br>-<br>100<br>-|||||| |---|---|---|---|---|---|---|---|---|---|---|---|---| |902523/20<br>902523/25<br>**(2) **<br>x<br>380<br>x<br>568<br>x<br>572<br>x<br>807<br>**(3) **<br>x<br>x<br>1003<br>x<br>x<br>1005<br>x<br>x<br>1009<br>x<br>2003<br>**(4) **<br>x<br>x<br>1<br>x<br>x<br>2<br>x<br>3<br>**(5) **<br>x<br>x<br>6<br>**(6) **<br>x<br>x<br>100<br>x<br>150<br>x<br>200<br>x<br>...<br>**(7) **<br>x<br>x<br>000<br>x<br>x<br>252<br>x<br>x<br>254<br>x<br>x<br>662<br>**(8) **<br>x<br>x<br>000<br>x<br>310<br>x<br>330<br>x<br>333<br>x<br>404<br>**Order code**||902523/20|Duct resistance thermometer<br>with stepped protection tube,<br>Protection IP65<br>Duct resistance thermometer<br>with plain protection tube,<br>Protection IP54<br> **Operating temperature in °C**<br>-50 to +200°C (standard)<br>-30 to +60°C (range only in conjunction with extra code<br>-30 to +80°C (standard)<br>0 to 60°C (range only in conjunction with extra code 33<br> **Measuring insert**<br>1 x Pt100 in 2-wire circuit<br>1 x Pt1000 in 2-wire circuit<br>1 x Ni 1000 in 2-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br>Class 1/3 DIN<br> **Protection tube diameter D in mm**<br>6mm (Type 902523/20: stepped down from 6mm dia. t<br> **Fitting length EL in mm (50**≤**EL**≤**500)**<br>100mm<br>150mm<br>200mm<br>please specify in plain text (in 50mm steps)<br> **Process connection**<br>no process connection<br>screwed pipe joint G 1/4 (1/4" pipe)<br>screwed pipe joint G 1/2 (1/2" pipe)<br>stop flange 6mm dia.<br> **Extra codes**<br>no extra code<br>protection tube stepped down from 6mm dia. to 3.3mm<br>analog transmitter, 4 – 20mA output (in conjunction wit<br>analog transmitter, 0 – 10V output (in conjunction with<br>Protection IP65<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>-|||||||||| |||||||||||||| |||||||||||||| |||902523/25||||||||||| |||||||||||||| |||||||||||||| |||||||||**(7)**<br>/<br>252<br>/||**(8)**|,...|| |||||||||||||| |**Order example**|||902523/20 -|572<br>-|1003 -|1<br>-||||0001||| - Please specify range in plain text. - 1.List extra codes in sequence, separated by commas. 02.03/00311507 ## **M. K. JUCHHEIM GmbH & Co** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net ## **JUMO Instrument Co. Ltd.** JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk ## **JUMO PROCESS CONTROL INC.** 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-mail: info@JumoUSA.com Internet: www.JumoUSA.com **==> picture [119 x 43] intentionally omitted <==** **Data Sheet 90.2523** **Page 6/6** ## **Stock versions:** |**(3)**<br><br>-<br><br>1001<br>-<br><br>2001<br>-<br><br>1003<br>-<br><br>1003<br>-<br><br>1003<br>-<br><br>2003<br>-<br><br>1003<br>-<br><br>2003<br>-<br><br>1003<br>-<br><br>1003<br>-<br><br>2003<br>-<br><br>1003<br>-<br>**(4)**<br>**(5)**<br>-<br>-<br>1<br>-<br>6<br>-<br>1<br>-<br>6<br>-<br>1<br>-<br>6<br>-||**(4)**|/<br>/<br>/<br>/<br>/<br>/<br>/<br>/<br>/<br>/<br>/<br>/<br>/<br>**(7)**<br>/<br>662<br>/<br>662<br>/<br>662<br>/|**(5)**<br>Sales No.<br>000<br>90/00065671<br>000<br>90/00065672<br>330 (0 to 40°C)<br>90/00064003<br>330 (0 to 60°C)<br>90/00065717<br>000<br>90/00055723<br>000<br>90/00055724<br>000<br>90/00064881<br>000<br>90/00064882<br>330 (0 to 60°C)<br>90/00064883<br>000<br>90/00064852<br>000<br>90/00064853<br>330 (-30 to +60°C)<br>90/00065073<br>**(8)**<br>Sales No.<br>000<br>90/00064894<br>330 (-30 to +60°C)<br>90/00065087<br>330 (0 to 60°C)<br>90/00064896| |---|---|---|---|---| |||||| |||||| 02.03/00311507
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →