Image not available
Illustrative purposes only
90/00059085
RTD Sensor, Push In, Probe, -50 °C, 80 °C, 100 ohm, Platinum
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: JUMO UK LTD
- Product type: RTD Temperature Sensors
- Sensing Temperature Min:-50°C; Sensing Temperature Max:+400°C; Resistance:100ohm; Product Range:902150/10 Series; SVHC:No SVHC (27-Jun-2018); External Diameter:6mm; External Length / Height:50mm; O
- RTD Type: Probe
- Resistance: 100ohm
- Probe Length: 50mm
- RTD Accuracy: -
- Product Range: -
- Probe Diameter: 6mm
- Probe Material: Stainless Steel
- Cable Termination: Wire Leaded
- Resistance @ 0°C: 100ohm
- Wire Configuration: 2-Wire
- RTD Element Material: Platinum
- Cable Length - Metric: 2.5m
- Cable Length - Imperial: 8.2ft
- Sensing Temperature Max: +400°C
- Sensing Temperature Min: -50°C
- Measured Temperature Max: 80°C
- Measured Temperature Min: -50°C
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 78.22 € |
| Current stock | 10+ |
| Lead time | 30 days |
**JUMO GmbH & Co. KG** Delivery address: Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net **JUMO Instrument Co. Ltd.** JUMO House Temple Bank, Riverway Harlow - Essex CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 63 52 62 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk **JUMO Process Control, Inc.** 8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO 1-800-554-JUMO Fax: 315-697-5867 E-mail: info@jumo.us Internet: www.jumo.us **Data Sheet 90.2150 (90.2105) Page 1/5** # **Push-in resistance thermometers with connecting cable** ■ **for temperatures from -50 to +400°C** ■ **as single or twin resistance thermometer** ■ **in 2-wire, 3-wire or 4-wire circuit** ■ **connecting cable in PVC, silicone, PTFE, or with metal braiding** Push-in resistance thermometers are preferred for measuring temperatures in liquids and gases. Applications include HVAC and refrigeration, heating installations, ovens, plant engineering, and laboratories. Depending on the version, the connecting cables are suitable for dry or humid areas within the range -50 to +350°C. The connection of the cable to the protection tube incorporates strain relief. A cable protector can be supplied as an option. The measuring insert is normally fitted with a Pt100 temperature sensor to EN 60 751, Class B in 2-wire circuit. Versions with Pt500 or Pt1000 are also available. Furthermore, there is a choice of 3-wire and 4-wire circuit connections. ## **Technical data** **Connection Connecting cable** **Protection tube Measuring insert Response times Accessories** cable ends available as: bare wires, with ferrules, receptacles or multipole connectors PVC, ambient temperature -5 to +80°C (+100/+105°C) silicone, ambient temperature -50 to +180°C PTFE, ambient temperature -190 to +260°C metal braiding, ambient temperature -50 to +350°C a shielded connecting cable can be supplied as an option stainless steel 1.4571, 5mm, 5.2mm, 6mm and 8mm dia. Pt100 temperature sensor, EN 60 751, Cl. B, 2-wire circuit t0.9 approx. 10sec, in water 0.2 m/sec, 6mm dia. pocket, see Data Sheet 90.9721 and 90.2440 2009-05-26/00311500 **JUMO GmbH & Co. KG** Delivery address: Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net **JUMO Instrument Co. Ltd. JUMO Process Control, Inc.** JUMO House 8 Technology Boulevard Temple Bank, Riverway Canastota, NY 13032, USA Harlow - Essex CM20 2DY, UK Phone: 315-697-JUMO Phone: +44 1279 63 55 33 1-800-554-JUMO Fax: +44 1279 63 52 62 Fax: 315-697-5867 E-mail: sales@jumo.co.uk E-mail: info@jumo.us Internet: www.jumo.co.uk Internet: www.jumo.us **==> picture [119 x 43] intentionally omitted <==** **Data Sheet 90.2150 (90.2105) Page 2/5** ## **Dimensions** **==> picture [505 x 229] intentionally omitted <==** **Type 902150/10 Type 902150/20** **Type 902150/30** **==> picture [164 x 229] intentionally omitted <==** **Type 902150/40** 2009-05-26/00311500 **JUMO GmbH & Co. KG** Delivery address: Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net **JUMO Instrument Co. Ltd.** JUMO House Temple Bank, Riverway Harlow - Essex CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 63 52 62 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk **JUMO Process Control, Inc.** 8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO 1-800-554-JUMO Fax: 315-697-5867 E-mail: info@jumo.us Internet: www.jumo.us **==> picture [119 x 43] intentionally omitted <==** **Data Sheet 90.2150 (90.2105) Page 3/5** ## **Order details: Push-in resistance thermometers with connecting cable** |||**(1) **|**Basic version**<br>Push-in resistance thermometer with<br>connecting cable, one-piece protection tube<br>in stainless steel<br>Push-in resistance thermometer with coiled<br>connecting cable, one-piece protection tube<br>in stainless steel<br> **Operating temperature in °C / connecting cable**<br>-50 to +180°C / silicone<br>-50 to +260°C / PTFE<br>-50 to +260°C / metal braiding<br>-5 to +80°C / PVC<br>-5 to +105°C / PUR<br>-5 to +105°C / PUR (for 1 x 2-wire circuit only)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt100 in 4-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br> **Protection tube diameter D in mm**<br>5mm<br>5.2mm<br>6mm<br> **Fitting length EL in mm**<br>45mm (standard with D 5mm and D 5.2mm)<br>50mm (with D 6mm only)<br>60mm (with D 6mm only)<br> **Connecting cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Connecting cable length AL in mm (500**≤**AL**≤**500000 for type**<br>1100mm (stretched)<br>2500mm<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>cable protector: coil<br>cable protector: tube<br>shielded connecting cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>-<br>902150/10 -<br>378<br>-<br>1001<br>-<br>1<br>-<br>6<br>-<br>50|**Basic version**<br>Push-in resistance thermometer with<br>connecting cable, one-piece protection tube<br>in stainless steel<br>Push-in resistance thermometer with coiled<br>connecting cable, one-piece protection tube<br>in stainless steel<br> **Operating temperature in °C / connecting cable**<br>-50 to +180°C / silicone<br>-50 to +260°C / PTFE<br>-50 to +260°C / metal braiding<br>-5 to +80°C / PVC<br>-5 to +105°C / PUR<br>-5 to +105°C / PUR (for 1 x 2-wire circuit only)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt100 in 4-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br> **Protection tube diameter D in mm**<br>5mm<br>5.2mm<br>6mm<br> **Fitting length EL in mm**<br>45mm (standard with D 5mm and D 5.2mm)<br>50mm (with D 6mm only)<br>60mm (with D 6mm only)<br> **Connecting cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Connecting cable length AL in mm (500**≤**AL**≤**500000 for type**<br>1100mm (stretched)<br>2500mm<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>cable protector: coil<br>cable protector: tube<br>shielded connecting cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>-<br>902150/10 -<br>378<br>-<br>1001<br>-<br>1<br>-<br>6<br>-<br>50|**Basic version**<br>Push-in resistance thermometer with<br>connecting cable, one-piece protection tube<br>in stainless steel<br>Push-in resistance thermometer with coiled<br>connecting cable, one-piece protection tube<br>in stainless steel<br> **Operating temperature in °C / connecting cable**<br>-50 to +180°C / silicone<br>-50 to +260°C / PTFE<br>-50 to +260°C / metal braiding<br>-5 to +80°C / PVC<br>-5 to +105°C / PUR<br>-5 to +105°C / PUR (for 1 x 2-wire circuit only)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt100 in 4-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br> **Protection tube diameter D in mm**<br>5mm<br>5.2mm<br>6mm<br> **Fitting length EL in mm**<br>45mm (standard with D 5mm and D 5.2mm)<br>50mm (with D 6mm only)<br>60mm (with D 6mm only)<br> **Connecting cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Connecting cable length AL in mm (500**≤**AL**≤**500000 for type**<br>1100mm (stretched)<br>2500mm<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>cable protector: coil<br>cable protector: tube<br>shielded connecting cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>-<br>902150/10 -<br>378<br>-<br>1001<br>-<br>1<br>-<br>6<br>-<br>50|**Basic version**<br>Push-in resistance thermometer with<br>connecting cable, one-piece protection tube<br>in stainless steel<br>Push-in resistance thermometer with coiled<br>connecting cable, one-piece protection tube<br>in stainless steel<br> **Operating temperature in °C / connecting cable**<br>-50 to +180°C / silicone<br>-50 to +260°C / PTFE<br>-50 to +260°C / metal braiding<br>-5 to +80°C / PVC<br>-5 to +105°C / PUR<br>-5 to +105°C / PUR (for 1 x 2-wire circuit only)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt100 in 4-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br> **Protection tube diameter D in mm**<br>5mm<br>5.2mm<br>6mm<br> **Fitting length EL in mm**<br>45mm (standard with D 5mm and D 5.2mm)<br>50mm (with D 6mm only)<br>60mm (with D 6mm only)<br> **Connecting cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Connecting cable length AL in mm (500**≤**AL**≤**500000 for type**<br>1100mm (stretched)<br>2500mm<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>cable protector: coil<br>cable protector: tube<br>shielded connecting cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>-<br>902150/10 -<br>378<br>-<br>1001<br>-<br>1<br>-<br>6<br>-<br>50|**Basic version**<br>Push-in resistance thermometer with<br>connecting cable, one-piece protection tube<br>in stainless steel<br>Push-in resistance thermometer with coiled<br>connecting cable, one-piece protection tube<br>in stainless steel<br> **Operating temperature in °C / connecting cable**<br>-50 to +180°C / silicone<br>-50 to +260°C / PTFE<br>-50 to +260°C / metal braiding<br>-5 to +80°C / PVC<br>-5 to +105°C / PUR<br>-5 to +105°C / PUR (for 1 x 2-wire circuit only)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt100 in 4-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br> **Protection tube diameter D in mm**<br>5mm<br>5.2mm<br>6mm<br> **Fitting length EL in mm**<br>45mm (standard with D 5mm and D 5.2mm)<br>50mm (with D 6mm only)<br>60mm (with D 6mm only)<br> **Connecting cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Connecting cable length AL in mm (500**≤**AL**≤**500000 for type**<br>1100mm (stretched)<br>2500mm<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>cable protector: coil<br>cable protector: tube<br>shielded connecting cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>-<br>902150/10 -<br>378<br>-<br>1001<br>-<br>1<br>-<br>6<br>-<br>50|**Basic version**<br>Push-in resistance thermometer with<br>connecting cable, one-piece protection tube<br>in stainless steel<br>Push-in resistance thermometer with coiled<br>connecting cable, one-piece protection tube<br>in stainless steel<br> **Operating temperature in °C / connecting cable**<br>-50 to +180°C / silicone<br>-50 to +260°C / PTFE<br>-50 to +260°C / metal braiding<br>-5 to +80°C / PVC<br>-5 to +105°C / PUR<br>-5 to +105°C / PUR (for 1 x 2-wire circuit only)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt100 in 4-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br> **Protection tube diameter D in mm**<br>5mm<br>5.2mm<br>6mm<br> **Fitting length EL in mm**<br>45mm (standard with D 5mm and D 5.2mm)<br>50mm (with D 6mm only)<br>60mm (with D 6mm only)<br> **Connecting cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Connecting cable length AL in mm (500**≤**AL**≤**500000 for type**<br>1100mm (stretched)<br>2500mm<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>cable protector: coil<br>cable protector: tube<br>shielded connecting cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>-<br>902150/10 -<br>378<br>-<br>1001<br>-<br>1<br>-<br>6<br>-<br>50||||| |---|---|---|---|---|---|---|---|---|---|---|---|---| |902150/10<br>902150/20<br>**(2) **<br>x<br>378<br>x<br>386<br>x<br>388<br>x<br>724<br>x<br>730<br>x<br>912<br>**(3) **<br>x<br>1001<br>x<br>x<br>1003<br>x<br>1011<br>x<br>2001<br>x<br>2003<br>**(4) **<br>x<br>x<br>1<br>x<br>x<br>2<br>**(5) **<br>x<br>5<br>x<br>5.2<br>x<br>x<br>6<br>**(6) **<br>x<br>45<br>x<br>x<br>50<br>x<br>60<br>**(7) **<br>x<br>x<br>03<br>x<br>x<br>11<br>x<br>x<br>13<br>x<br>x<br>80<br>**(8) **<br>x<br>1100<br>x<br>2500<br>x<br>...<br>**(9) **<br>x<br>x<br>000<br>x<br>315<br>x<br>316<br>x<br>x<br>317<br>**Order code**||902150/10|Push-in resistance thermometer with<br>connecting cable, one-piece protection tube<br>in stainless steel<br>Push-in resistance thermometer with coiled<br>connecting cable, one-piece protection tube<br>in stainless steel<br> **Operating temperature in °C / connecting cable**<br>-50 to +180°C / silicone<br>-50 to +260°C / PTFE<br>-50 to +260°C / metal braiding<br>-5 to +80°C / PVC<br>-5 to +105°C / PUR<br>-5 to +105°C / PUR (for 1 x 2-wire circuit only)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt100 in 4-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br> **Protection tube diameter D in mm**<br>5mm<br>5.2mm<br>6mm<br> **Fitting length EL in mm**<br>45mm (standard with D 5mm and D 5.2mm)<br>50mm (with D 6mm only)<br>60mm (with D 6mm only)<br> **Connecting cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Connecting cable length AL in mm (500**≤**AL**≤**50000**<br>1100mm (stretched)<br>2500mm<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>cable protector: coil<br>cable protector: tube<br>shielded connecting cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>-|||||||||| |||||||||||||| |||||||||||||| |||902150/20||||||||||| |||||||||||||| |||||||||||||| |||||||||||**902150/10)**<br>**(7)**<br>-<br><br>-<br>11<br>|<br>**(8)**<br>-<br>/<br>-<br>2500<br>/|**(9)**<br>,...<br>0001| |||||||||||||| |**Order example**|||902150/10 -|378<br>-|1001<br>-|1<br>-||50||||| 1. List extra codes in sequence, separated by commas. 2009-05-26/00311500 **JUMO GmbH & Co. KG** Delivery address: Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net **JUMO Instrument Co. Ltd.** JUMO House Temple Bank, Riverway Harlow - Essex CM20 2DY, UK Phone: +44 1279 63 55 33 Fax: +44 1279 63 52 62 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk **JUMO Process Control, Inc.** 8 Technology Boulevard Canastota, NY 13032, USA Phone: 315-697-JUMO 1-800-554-JUMO Fax: 315-697-5867 E-mail: info@jumo.us Internet: www.jumo.us **==> picture [119 x 43] intentionally omitted <==** **Data Sheet 90.2150 (90.2105) Page 4/5** ## **Order details: Push-in resistance thermometers with connecting cable** |||**(1) **|**Basic version**<br>Push-in resistance thermometer with<br>connecting cable, multi-piece protection<br>tube (welded) in stainless steel<br>Push-in resistance thermometer with<br>connecting cable,<br>protection tube angled 90° (welded)<br>in stainless steel<br> **Operating temperature in °C / connecting cable**<br>-50 to +180°C / silicone<br>-50 to +260°C / PTFE<br>-50 to +260°C / metal braiding<br>-50 to +350°C / metal braiding<br>-50 to +400°C / metal braiding<br>-5 to +80°C / PVC<br>5 to 105°C / PUR (for 1 x 2-wire circuit only)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt100 in 4-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br> **Protection tube diameter D in mm**<br>6mm<br>8mm<br> **Fitting length EL in mm (50**≤**EL**≤**500)**<br>50mm<br>60mm<br>100mm<br>150mm<br>200mm<br>please specify in plain text (50mm steps)<br> **Connecting cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Connecting cable length AL in mm (500**≤**AL**≤**500000)**<br>2500mm<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>stepped protection tube<br>cable protector: coil<br>cable protector: tube<br>shielded connecting cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>-<br>-<br>902150/30 -<br>378<br>-<br>1001<br>-<br>1<br>-<br>6<br>-|**Basic version**<br>Push-in resistance thermometer with<br>connecting cable, multi-piece protection<br>tube (welded) in stainless steel<br>Push-in resistance thermometer with<br>connecting cable,<br>protection tube angled 90° (welded)<br>in stainless steel<br> **Operating temperature in °C / connecting cable**<br>-50 to +180°C / silicone<br>-50 to +260°C / PTFE<br>-50 to +260°C / metal braiding<br>-50 to +350°C / metal braiding<br>-50 to +400°C / metal braiding<br>-5 to +80°C / PVC<br>5 to 105°C / PUR (for 1 x 2-wire circuit only)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt100 in 4-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br> **Protection tube diameter D in mm**<br>6mm<br>8mm<br> **Fitting length EL in mm (50**≤**EL**≤**500)**<br>50mm<br>60mm<br>100mm<br>150mm<br>200mm<br>please specify in plain text (50mm steps)<br> **Connecting cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Connecting cable length AL in mm (500**≤**AL**≤**500000)**<br>2500mm<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>stepped protection tube<br>cable protector: coil<br>cable protector: tube<br>shielded connecting cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>-<br>-<br>902150/30 -<br>378<br>-<br>1001<br>-<br>1<br>-<br>6<br>-|**Basic version**<br>Push-in resistance thermometer with<br>connecting cable, multi-piece protection<br>tube (welded) in stainless steel<br>Push-in resistance thermometer with<br>connecting cable,<br>protection tube angled 90° (welded)<br>in stainless steel<br> **Operating temperature in °C / connecting cable**<br>-50 to +180°C / silicone<br>-50 to +260°C / PTFE<br>-50 to +260°C / metal braiding<br>-50 to +350°C / metal braiding<br>-50 to +400°C / metal braiding<br>-5 to +80°C / PVC<br>5 to 105°C / PUR (for 1 x 2-wire circuit only)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt100 in 4-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br> **Protection tube diameter D in mm**<br>6mm<br>8mm<br> **Fitting length EL in mm (50**≤**EL**≤**500)**<br>50mm<br>60mm<br>100mm<br>150mm<br>200mm<br>please specify in plain text (50mm steps)<br> **Connecting cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Connecting cable length AL in mm (500**≤**AL**≤**500000)**<br>2500mm<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>stepped protection tube<br>cable protector: coil<br>cable protector: tube<br>shielded connecting cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>-<br>-<br>902150/30 -<br>378<br>-<br>1001<br>-<br>1<br>-<br>6<br>-|**Basic version**<br>Push-in resistance thermometer with<br>connecting cable, multi-piece protection<br>tube (welded) in stainless steel<br>Push-in resistance thermometer with<br>connecting cable,<br>protection tube angled 90° (welded)<br>in stainless steel<br> **Operating temperature in °C / connecting cable**<br>-50 to +180°C / silicone<br>-50 to +260°C / PTFE<br>-50 to +260°C / metal braiding<br>-50 to +350°C / metal braiding<br>-50 to +400°C / metal braiding<br>-5 to +80°C / PVC<br>5 to 105°C / PUR (for 1 x 2-wire circuit only)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt100 in 4-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br> **Protection tube diameter D in mm**<br>6mm<br>8mm<br> **Fitting length EL in mm (50**≤**EL**≤**500)**<br>50mm<br>60mm<br>100mm<br>150mm<br>200mm<br>please specify in plain text (50mm steps)<br> **Connecting cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Connecting cable length AL in mm (500**≤**AL**≤**500000)**<br>2500mm<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>stepped protection tube<br>cable protector: coil<br>cable protector: tube<br>shielded connecting cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>-<br>-<br>902150/30 -<br>378<br>-<br>1001<br>-<br>1<br>-<br>6<br>-|**Basic version**<br>Push-in resistance thermometer with<br>connecting cable, multi-piece protection<br>tube (welded) in stainless steel<br>Push-in resistance thermometer with<br>connecting cable,<br>protection tube angled 90° (welded)<br>in stainless steel<br> **Operating temperature in °C / connecting cable**<br>-50 to +180°C / silicone<br>-50 to +260°C / PTFE<br>-50 to +260°C / metal braiding<br>-50 to +350°C / metal braiding<br>-50 to +400°C / metal braiding<br>-5 to +80°C / PVC<br>5 to 105°C / PUR (for 1 x 2-wire circuit only)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt100 in 4-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br> **Protection tube diameter D in mm**<br>6mm<br>8mm<br> **Fitting length EL in mm (50**≤**EL**≤**500)**<br>50mm<br>60mm<br>100mm<br>150mm<br>200mm<br>please specify in plain text (50mm steps)<br> **Connecting cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Connecting cable length AL in mm (500**≤**AL**≤**500000)**<br>2500mm<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>stepped protection tube<br>cable protector: coil<br>cable protector: tube<br>shielded connecting cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>-<br>-<br>902150/30 -<br>378<br>-<br>1001<br>-<br>1<br>-<br>6<br>-|**(6)**<br><br>50<br>|||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---| |902150/30<br>902150/40<br>**(2) **<br>x<br>378<br>x<br>386<br>x<br>388<br>x<br>397<br>x<br>402<br>x<br>724<br>x<br>912<br>**(3) **<br>x<br>1001<br>x<br>x<br>1003<br>x<br>1011<br>x<br>2001<br>x<br>x<br>2003<br>**(4) **<br>x<br>x<br>1<br>x<br>x<br>2<br>**(5) **<br>x<br>x<br>6<br>x<br>8<br>**(6) **<br>x<br>50<br>x<br>x<br>60<br>x<br>x<br>100<br>x<br>x<br>150<br>x<br>x<br>200<br>x<br>x<br>...<br>**(7) **<br>x<br>x<br>03<br>x<br>x<br>11<br>x<br>x<br>13<br>x<br>x<br>80<br>**(8) **<br>x<br>x<br>2500<br>x<br>x<br>...<br>**(9) **<br>x<br>000<br>x<br>310<br>x<br>315<br>x<br>316<br>x<br>x<br>317<br>**Order code**||902150/30|Push-in resistance thermometer with<br>connecting cable, multi-piece protection<br>tube (welded) in stainless steel<br>Push-in resistance thermometer with<br>connecting cable,<br>protection tube angled 90° (welded)<br>in stainless steel<br> **Operating temperature in °C / connecting cable**<br>-50 to +180°C / silicone<br>-50 to +260°C / PTFE<br>-50 to +260°C / metal braiding<br>-50 to +350°C / metal braiding<br>-50 to +400°C / metal braiding<br>-5 to +80°C / PVC<br>5 to 105°C / PUR (for 1 x 2-wire circuit only)<br> **Measuring insert**<br>1 x Pt100 in 3-wire circuit<br>1 x Pt100 in 2-wire circuit<br>1 x Pt100 in 4-wire circuit<br>2 x Pt100 in 3-wire circuit<br>2 x Pt100 in 2-wire circuit<br> **Tolerance class to EN 60 751**<br>Class B (standard)<br>Class A<br> **Protection tube diameter D in mm**<br>6mm<br>8mm<br> **Fitting length EL in mm (50**≤**EL**≤**500)**<br>50mm<br>60mm<br>100mm<br>150mm<br>200mm<br>please specify in plain text (50mm steps)<br> **Connecting cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Connecting cable length AL in mm (500**≤**AL**≤**50000**<br>2500mm<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>stepped protection tube<br>cable protector: coil<br>cable protector: tube<br>shielded connecting cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>-||||||||||| ||||||||||||||| ||||||||||||||| |||902150/40|||||||||||| ||||||||||||||| ||||||||||||||| ||||||||||**(7)**<br>-<br>-<br>11||-<br>-|**(8)**<br>/<br>2500<br>/|**(9)**<br>,...<br>0001| ||||||||||||||| |**Order example**|||902150/30 -|378<br>-|1001<br>-|1<br>-|||||||| 1. List extra codes in sequence, separated by commas. 2009-05-26/00311500 **JUMO GmbH & Co. KG** Delivery address: Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net **JUMO Instrument Co. Ltd. JUMO Process Control, Inc.** JUMO House 8 Technology Boulevard Temple Bank, Riverway Canastota, NY 13032, USA Harlow - Essex CM20 2DY, UK Phone: 315-697-JUMO Phone: +44 1279 63 55 33 1-800-554-JUMO Fax: +44 1279 63 52 62 Fax: 315-697-5867 E-mail: sales@jumo.co.uk E-mail: info@jumo.us Internet: www.jumo.co.uk Internet: www.jumo.us **==> picture [119 x 43] intentionally omitted <==** **Data Sheet 90.2150 (90.2105) Page 5/5** ## **Stock versions** |**(1)**<br>-<br>902150/10<br>-<br>902150/10<br>-<br>902150/10<br>-<br>902150/10<br>-<br>902150/20<br>-<br>902150/30<br>-<br>902150/30<br>-<br>902150/30<br>-<br>902150/30<br>-<br>902150/40<br>-|**(2)**<br>-<br>378<br>-<br>378<br>-<br>378<br>-<br>724<br>-<br>730<br>-<br>388<br>-<br>388<br>-<br>388<br>-<br>388<br>-<br>397<br>-|**(3)**<br>-<br>1003<br>-<br>1003<br>-<br>1001<br>-<br>1003<br>-<br>1003<br>-<br>1003<br>-<br>1003<br>-<br>1001<br>-<br>1001<br>-<br>1003<br>-|**(4)**<br>-<br>1<br>-<br>1<br>-<br>1<br>-<br>1<br>-<br>1<br>-<br>1<br>-<br>1<br>-<br>1<br>-<br>1<br>-<br>1<br>-|**(5)**<br>-<br>5.2<br>-<br>6<br>-<br>6<br>-<br>6<br>-<br>6<br>-<br>6<br>-<br>6<br>-<br>6<br>-<br>6<br>-<br>6<br>-|**(6)**<br>-<br>45<br>-<br>50<br>-<br>50<br>-<br>50<br>-<br>50<br>-<br>50<br>-<br>100<br>-<br>50<br>-<br>100<br>-<br>60<br>-|**(7)**<br>-<br>11<br>-<br>11<br>-<br>11<br>-<br>11<br>-<br>11<br>-<br>11<br>-<br>11<br>-<br>11<br>-<br>11<br>-<br>11<br>-|**(8)**<br>/<br>2500<br>/<br>2500<br>/<br>2500<br>/<br>2500<br>/<br>1100<br>/<br>2500<br>/<br>2500<br>/<br>2500<br>/<br>2500<br>/<br>2500<br>/|**(9)**<br>Sales No.<br>000<br>90/00326037<br>000<br>90/00389771<br>000<br>90/00392513<br>000<br>90/00059085<br>000<br>90/00065495<br>315,317<br>90/00055718<br>315,317<br>90/00055719<br>315,317<br>90/00065451<br>315,317<br>90/00065453<br>317<br>90/00055715| |---|---|---|---|---|---|---|---|---| 2009-05-26/00311500
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →