Image not available
Illustrative purposes only
90/00049205
Thermocouple, Material Insulated, 100mm, K, -200 °C, 800 °C, Nickel Chromium, 100 ", 2.5 m
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: JUMO UK LTD
- Product type: Thermocouples
- Thermocouple Type:K; Sensing Temperature Min:-200°C; Sensing Temperature Max:+1200°C; Sensor Body Material:Nickel Chromium; Lead Length:2.5m; Product Range:901221/32 Series; SVHC:No SVH
- SVHC: No SVHC (16-Jul-2019)
- Insulation: Silicone
- Product Range: -
- Thermocouple Type: K
- Lead Length - Metric: 2.5m
- Sensor Body Material: Nickel Chromium
- Probe Length - Metric: -
- Lead Length - Imperial: 100"
- Thermocouple Shielding: Shielded
- Probe Diameter - Metric: -
- Probe Length - Imperial: -
- Sensing Temperature Min: -200°C
- Measured Temperature Max: 800°C
- Measured Temperature Min: -200°C
- Thermocouple Termination: Wire Leaded
- Probe Diameter - Imperial: -
- Thermocouple Wire Standard: -
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 95.73 € |
| Current stock | 10+ |
| Lead time | 30 days |
**JUMO Instrument Co. Ltd.** ## **JUMO GmbH & Co. KG** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk ## **JUMO PROCESS CONTROL INC.** 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 e-mail: info@JumoUSA.com Internet: www.JumoUSA.com **Data Sheet 90.1221** **Page 1/7** # **Mineral-insulated thermocouples to DIN 43 710 and EN 60 584** ■ **for temperatures from -200 to +1200°C** ■ **flexible sheath with shock-proof measuring insert** ■ **protection tube diameter from 0.5mm** ■ **fast response** ■ **fitting length to suit application** Thanks to their special properties, mineral-insulated thermocouples are used in chemical plant, power stations, pipelines, in engine construction and on test beds. The thermocouple wires are embedded in compressed fire-resistant magnesium oxide inside the flexible thin-walled sheath. The excellent heat transfer between the sheath and the thermocouple enables short response times (t0.5 from 0.15sec) and high measurement accuracy. The shock-proof construction ensures a long life. The minimum bending radius is 5 x the external diameter. The minimum fitting length EL is 50mm for 0.5mm to 2.0mm dia., and 100mm for 3.0 to 6.0mm dia. The thermocouples are normally insulated from the sheath. The measuring insert is fitted with thermocouples to EN 60 584 or DIN 43 710. Versions with two thermocouples are also available. **Test pressure:** 40 bar (helium) leakage test at the measurement point. **Insulation resistance:** thermocouple against sheath at ambient temperature for lengths up to 1m: 200MΩ, for lengths 1m and above: 200MΩ x m. ## **Technical data** **Connection** available with cable ends as: bare wires, with ferrules, receptacles or multipole connector **Connecting cable** silicone, ambient temperature -50 to +180°C PTFE, ambient temperature -190 to +260°C metal braiding, ambient temperature -20 to +350°C **Protection tube** stainless steel 1.4541, thermocouple Type L and Type J Inconel 2.4816 (Inconel 600) , thermocouple Type K **Measuring insert** insulated assembly: 1 x Fe-Con J, EN 60 584, Cl. 2, operating temperature -200 to +800°C 1 x Fe-Con L, DIN 43 710, Cl. 2, operating temperature -200 to +800°C 1 x NiCr-Ni K, EN 60 584, Cl. 2, operating temperature -200 to +1200°C 2 x Fe-Con L, DIN 43 710, Cl. 2, operating temperature -200 to +800°C 2 x NiCr-Ni K, EN 60 584, Cl. 2, operating temperature -200 to +1200°C **Response times** in water with 0.4m/sec / in air with 2m/sec 0.5mm dia: water t0.5 = 0.15sec, t0.9 = 0.30sec / air t0.5 = 3.5sec, t0.9 = 8.0sec 1.0mm dia: water t0.5 = 0.20sec, t0.9 = 0.60sec / air t0.5 = 7.5sec, t0.9 = 17.0sec 1.5mm dia: water t0.5 = 0.40sec, t0.9 = 0.90sec / air t0.5 = 10.0sec, t0.9 = 25.0sec 2.0mm dia: water t0.5 = 0.80sec, t0.9 = 2.60sec / air t0.5 = 13.0sec, t0.9 = 34.0sec 3.0mm dia: water t0.5 = 1.00sec, t0.9 = 2.80sec / air t0.5 = 22.0sec, t0.9 = 64.0sec 4.5mm dia: water t0.5 = 2.50sec, t0.9 = 6.50sec / air t0.5 = 34.0sec, t0.9 = 113.0sec 6.0mm dia: water t0.5 = 3.00sec, t0.9 = 9.00sec / air t0.5 = 55.0sec, t0.9 = 170.0sec 11.03/00073440 ## **JUMO GmbH & Co. KG** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net ## **JUMO Instrument Co. Ltd.** JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk ## **JUMO PROCESS CONTROL INC.** 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 e-mail: info@JumoUSA.com Internet: www.JumoUSA.com **==> picture [119 x 43] intentionally omitted <==** ## **Data Sheet 90.1221** **Page 2/7** ## **Lead resistances in** Ω **/m at 20°C for mineral-insulated thermocouples** |**Diameter**|**1 thermocouple**|**2 thermocouples**| |---|---|---| |**D in mm**|**resistance in**Ω**/m**|**resistance in**Ω**/m**| |**Thermocouple Fe-Con L**||| |6.0|0.66|0.85| |4.5|1.40|1.80| |3.0|2.70|3.50| |2.0|5.00|7.70| |1.5|12.00|-| |1.0|21.50|-| |**Thermocouple Fe-Con J**||| |6.0|0.54|-| |3.0|2.10|-| |2.0|8.60|-| |1.5|15.00|-| |1.0|34.00|-| |**Thermocouple NiCr-Ni K**||| |6.0|0.88|2.70| |4.5|1.56|4.80| |3.0|3.50|11.00| |2.0|7.90|25.00| |1.5|14.00|-| |1.0|32.00|-| |0.5|126.00|-| 11.03/00073440 **JUMO GmbH & Co. KG** **JUMO Instrument Co. Ltd.** ## **JUMO PROCESS CONTROL INC.** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 e-mail: info@JumoUSA.com Internet: www.JumoUSA.com **==> picture [119 x 43] intentionally omitted <==** ## **Data Sheet 90.1221** ## **Page 3/7** ## **Dimensions** **==> picture [505 x 229] intentionally omitted <==** **Type 901221/10** **Type 901221/20** **Type 901221/3x** **==> picture [164 x 229] intentionally omitted <==** **Type 901221/40** 11.03/00073440 **JUMO GmbH & Co. KG** **JUMO PROCESS CONTROL INC.** **JUMO Instrument Co. Ltd.** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 e-mail: info@JumoUSA.com Internet: www.JumoUSA.com **==> picture [119 x 43] intentionally omitted <==** ## **Data Sheet 90.1221** ## **Page 4/7** ## **Order details: Mineral-insulated thermocouples to DIN 43 710 and EN 60 584** |||**(1) **|**Basic version**<br>Mineral-insulated thermocouple with bare<br>connecting wires<br>Mineral-insulated thermocouple with<br>standard flat emf-free connector<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br>2 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br> **Protection tube diameter D in mm**<br>0.5mm, only with Type 1 x NiCr-Ni K<br>1mm<br>1.5mm<br>2mm<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>/<br> ,...<br>901221/10 - 1042 -<br>3<br>-<br>200<br>/<br>0001|**Basic version**<br>Mineral-insulated thermocouple with bare<br>connecting wires<br>Mineral-insulated thermocouple with<br>standard flat emf-free connector<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br>2 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br> **Protection tube diameter D in mm**<br>0.5mm, only with Type 1 x NiCr-Ni K<br>1mm<br>1.5mm<br>2mm<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>/<br> ,...<br>901221/10 - 1042 -<br>3<br>-<br>200<br>/<br>0001|**Basic version**<br>Mineral-insulated thermocouple with bare<br>connecting wires<br>Mineral-insulated thermocouple with<br>standard flat emf-free connector<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br>2 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br> **Protection tube diameter D in mm**<br>0.5mm, only with Type 1 x NiCr-Ni K<br>1mm<br>1.5mm<br>2mm<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>/<br> ,...<br>901221/10 - 1042 -<br>3<br>-<br>200<br>/<br>0001|**Basic version**<br>Mineral-insulated thermocouple with bare<br>connecting wires<br>Mineral-insulated thermocouple with<br>standard flat emf-free connector<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br>2 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br> **Protection tube diameter D in mm**<br>0.5mm, only with Type 1 x NiCr-Ni K<br>1mm<br>1.5mm<br>2mm<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>/<br> ,...<br>901221/10 - 1042 -<br>3<br>-<br>200<br>/<br>0001|**Basic version**<br>Mineral-insulated thermocouple with bare<br>connecting wires<br>Mineral-insulated thermocouple with<br>standard flat emf-free connector<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br>2 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br> **Protection tube diameter D in mm**<br>0.5mm, only with Type 1 x NiCr-Ni K<br>1mm<br>1.5mm<br>2mm<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>/<br> ,...<br>901221/10 - 1042 -<br>3<br>-<br>200<br>/<br>0001|||||| |---|---|---|---|---|---|---|---|---|---|---|---|---| |901221/10<br>901221/20<br>**(2) **<br>x<br>x<br>1040<br>x<br>x<br>1042<br>x<br>x<br>1043<br>x<br>2042<br>x<br>2043<br>**(3) **<br>x<br>0.5<br>x<br>x<br>1<br>x<br>x<br>1.5<br>x<br>x<br>2<br>x<br>x<br>3<br>x<br>x<br>4.5<br>x<br>x<br>6<br>**(4) **<br>x<br>x<br>100<br>x<br>x<br>200<br>x<br>x<br>300<br>x<br>x<br>400<br>x<br>x<br>500<br>x<br>x<br>...<br>**(5) **<br>x<br>x<br>000<br>x<br>x<br>309<br>**Order code**||901221/10|Mineral-insulated thermocouple with bare<br>connecting wires<br>Mineral-insulated thermocouple with<br>standard flat emf-free connector<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, s<br>1 x Fe-Con L, operating temperature -200 to +800°C, s<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C,<br>2 x Fe-Con L, operating temperature -200 to +800°C, s<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C,<br> **Protection tube diameter D in mm**<br>0.5mm, only with Type 1 x NiCr-Ni K<br>1mm<br>1.5mm<br>2mm<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>/<br>|||||||||| |||||||||||||| |||||||||||||| |||901221/20||||||||||| |||||||||||||| |||||||||||||| |||||||||||||| |||||||||||||| |||||||||||||| |||||||||||||| |**Order example**|||901221/10 -|1042 -|3<br>-|200<br>/||||||| 1. List extra codes in sequence, separated by commas. 11.03/00073440 **JUMO GmbH & Co. KG** **JUMO PROCESS CONTROL INC.** **JUMO Instrument Co. Ltd.** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 e-mail: info@JumoUSA.com Internet: www.JumoUSA.com **==> picture [119 x 43] intentionally omitted <==** ## **Data Sheet 90.1221** ## **Page 5/7** ## **Order details: Mineral-insulated thermocouples to DIN 43 710 and EN 60 584** ||||**(1) **|**Basic version**<br>Mineral-insulated thermocouple with<br>siliconized compensating cable<br>Mineral-insulated thermocouple with<br>PTFE- insulated compensating cable<br>Mineral-insulated thermocouple and<br>compensating cable with metal-braiding and<br>glass silk insulation<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br>2 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br> **Protection tube diameter D in mm**<br>0.5mm, only with Type 1 x NiCr-Ni K<br>1mm<br>1.5mm<br>2mm<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Compensating cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Compensating cable length AL in mm (500**≤**AL**≤**500000)**<br>2500mm (standard)<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>shielded compensating cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>**(7)**<br>-<br>-<br>-<br>-<br>-<br>/<br> ,...<br>901221/32 - 1042 -<br>3<br>-<br>200<br>-<br>11<br>- 2500<br>/<br>0001|**Basic version**<br>Mineral-insulated thermocouple with<br>siliconized compensating cable<br>Mineral-insulated thermocouple with<br>PTFE- insulated compensating cable<br>Mineral-insulated thermocouple and<br>compensating cable with metal-braiding and<br>glass silk insulation<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br>2 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br> **Protection tube diameter D in mm**<br>0.5mm, only with Type 1 x NiCr-Ni K<br>1mm<br>1.5mm<br>2mm<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Compensating cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Compensating cable length AL in mm (500**≤**AL**≤**500000)**<br>2500mm (standard)<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>shielded compensating cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>**(7)**<br>-<br>-<br>-<br>-<br>-<br>/<br> ,...<br>901221/32 - 1042 -<br>3<br>-<br>200<br>-<br>11<br>- 2500<br>/<br>0001|**Basic version**<br>Mineral-insulated thermocouple with<br>siliconized compensating cable<br>Mineral-insulated thermocouple with<br>PTFE- insulated compensating cable<br>Mineral-insulated thermocouple and<br>compensating cable with metal-braiding and<br>glass silk insulation<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br>2 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br> **Protection tube diameter D in mm**<br>0.5mm, only with Type 1 x NiCr-Ni K<br>1mm<br>1.5mm<br>2mm<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Compensating cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Compensating cable length AL in mm (500**≤**AL**≤**500000)**<br>2500mm (standard)<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>shielded compensating cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>**(7)**<br>-<br>-<br>-<br>-<br>-<br>/<br> ,...<br>901221/32 - 1042 -<br>3<br>-<br>200<br>-<br>11<br>- 2500<br>/<br>0001|**Basic version**<br>Mineral-insulated thermocouple with<br>siliconized compensating cable<br>Mineral-insulated thermocouple with<br>PTFE- insulated compensating cable<br>Mineral-insulated thermocouple and<br>compensating cable with metal-braiding and<br>glass silk insulation<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br>2 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br> **Protection tube diameter D in mm**<br>0.5mm, only with Type 1 x NiCr-Ni K<br>1mm<br>1.5mm<br>2mm<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Compensating cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Compensating cable length AL in mm (500**≤**AL**≤**500000)**<br>2500mm (standard)<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>shielded compensating cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>**(7)**<br>-<br>-<br>-<br>-<br>-<br>/<br> ,...<br>901221/32 - 1042 -<br>3<br>-<br>200<br>-<br>11<br>- 2500<br>/<br>0001|**Basic version**<br>Mineral-insulated thermocouple with<br>siliconized compensating cable<br>Mineral-insulated thermocouple with<br>PTFE- insulated compensating cable<br>Mineral-insulated thermocouple and<br>compensating cable with metal-braiding and<br>glass silk insulation<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br>2 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br> **Protection tube diameter D in mm**<br>0.5mm, only with Type 1 x NiCr-Ni K<br>1mm<br>1.5mm<br>2mm<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Compensating cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Compensating cable length AL in mm (500**≤**AL**≤**500000)**<br>2500mm (standard)<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>shielded compensating cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>**(7)**<br>-<br>-<br>-<br>-<br>-<br>/<br> ,...<br>901221/32 - 1042 -<br>3<br>-<br>200<br>-<br>11<br>- 2500<br>/<br>0001||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |901221/32<br>901221/33<br>901221/34<br>**(2) **<br>x<br>x<br>x<br>1040<br>x<br>x<br>x<br>1042<br>x<br>x<br>x<br>1043<br>x<br>x<br>2042<br>x<br>x<br>2043<br>**(3) **<br>x<br>x<br>x<br>0.5<br>x<br>x<br>x<br>1<br>x<br>x<br>x<br>1.5<br>x<br>x<br>x<br>2<br>x<br>x<br>x<br>3<br>x<br>x<br>x<br>4.5<br>x<br>x<br>x<br>6<br>**(4) **<br>x<br>x<br>x<br>100<br>x<br>x<br>x<br>200<br>x<br>x<br>x<br>300<br>x<br>x<br>x<br>400<br>x<br>x<br>x<br>500<br>x<br>x<br>x<br>...<br>**(5) **<br>x<br>x<br>x<br>03<br>x<br>x<br>x<br>11<br>x<br>x<br>x<br>13<br>x<br>x<br>x<br>80<br>**(6) **<br>x<br>x<br>x<br>2500<br>x<br>x<br>x<br>...<br>**(7) **<br>x<br>x<br>x<br>000<br>x<br>x<br>x<br>309<br>x<br>x<br>x<br>317<br>**Order code**|||901221/32|Mineral-insulated thermocouple with<br>siliconized compensating cable<br>Mineral-insulated thermocouple with<br>PTFE- insulated compensating cable<br>Mineral-insulated thermocouple and<br>compensating cable with metal-braiding and<br>glass silk insulation<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, s<br>1 x Fe-Con L, operating temperature -200 to +800°C, s<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C,<br>2 x Fe-Con L, operating temperature -200 to +800°C, s<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C,<br> **Protection tube diameter D in mm**<br>0.5mm, only with Type 1 x NiCr-Ni K<br>1mm<br>1.5mm<br>2mm<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Compensating cable end**<br>bare cable ends<br>ferrules to DIN 46 228 Part 4 (standard)<br>receptacle 6.3 to DIN 46 247<br>multipole connector (please specify type in plain text)<br> **Compensating cable length AL in mm (500**≤**AL**≤**500**<br>2500mm (standard)<br>please specify in plain text (500mm steps)<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>shielded compensating cable<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>-||||||||||| |||||||||||||||| |||||||||||||||| |||||||||||||||| ||||901221/33|||||||||||| |||||||||||||||| |||||||||||||||| ||||901221/34|||||||||||| |||||||||||||||| |||||||||||||||| |||||||||||||||| |||||||||||||||| |**Order example**||||901221/32 -|1042 -|3<br>-|200<br>-|||||||| 1. List extra codes in sequence, separated by commas. 11.03/00073440 **JUMO GmbH & Co. KG** **JUMO PROCESS CONTROL INC.** **JUMO Instrument Co. Ltd.** Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 e-mail: info@JumoUSA.com Internet: www.JumoUSA.com **==> picture [119 x 43] intentionally omitted <==** ## **Data Sheet 90.1221** **Page 6/7** ## **Order details: Mineral-insulated thermocouples to DIN 43 710 and EN 60 584** ||**(1) **|**Basic version**<br>Mineral-insulated thermocouple with<br>terminal head Form J<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br>2 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br> **Protection tube diameter D in mm**<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Process connection**<br>thread 3/8" pipe<br>thread 1/2" pipe<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>/<br> ,...<br>901221/40 - 1042 -<br>6<br>-<br>200<br>-<br>104<br>/<br>0001|**Basic version**<br>Mineral-insulated thermocouple with<br>terminal head Form J<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br>2 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br> **Protection tube diameter D in mm**<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Process connection**<br>thread 3/8" pipe<br>thread 1/2" pipe<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>/<br> ,...<br>901221/40 - 1042 -<br>6<br>-<br>200<br>-<br>104<br>/<br>0001|**Basic version**<br>Mineral-insulated thermocouple with<br>terminal head Form J<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br>2 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br> **Protection tube diameter D in mm**<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Process connection**<br>thread 3/8" pipe<br>thread 1/2" pipe<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>/<br> ,...<br>901221/40 - 1042 -<br>6<br>-<br>200<br>-<br>104<br>/<br>0001|**Basic version**<br>Mineral-insulated thermocouple with<br>terminal head Form J<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br>2 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br> **Protection tube diameter D in mm**<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Process connection**<br>thread 3/8" pipe<br>thread 1/2" pipe<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>/<br> ,...<br>901221/40 - 1042 -<br>6<br>-<br>200<br>-<br>104<br>/<br>0001|**Basic version**<br>Mineral-insulated thermocouple with<br>terminal head Form J<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br>2 x Fe-Con L, operating temperature -200 to +800°C, sheath, Mat. Ref. 1.4541<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C, sheath, Mat. Ref. 2.4816<br> **Protection tube diameter D in mm**<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Process connection**<br>thread 3/8" pipe<br>thread 1/2" pipe<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>**(6)**<br>-<br>-<br>-<br>-<br>/<br> ,...<br>901221/40 - 1042 -<br>6<br>-<br>200<br>-<br>104<br>/<br>0001|||| |---|---|---|---|---|---|---|---|---|---| |901221/40<br>**(2) **<br>x<br>1040<br>x<br>1042<br>x<br>1043<br>x<br>2042<br>x<br>2043<br>**(3) **<br>x<br>3<br>x<br>4.5<br>x<br>6<br>**(4) **<br>x<br>100<br>x<br>200<br>x<br>300<br>x<br>400<br>x<br>500<br>x<br>...<br>**(5) **<br>x<br>103<br>x<br>104<br>**(6) **<br>x<br>000<br>x<br>309<br>**Order code**|901221/40|Mineral-insulated thermocouple with<br>terminal head Form J<br> **Measuring insert / operating temperature in °C**<br>1 x Fe-Con J, operating temperature -200 to +800°C, s<br>1 x Fe-Con L, operating temperature -200 to +800°C, s<br>1 x NiCr-Ni K, operating temperature -200 to +1200°C,<br>2 x Fe-Con L, operating temperature -200 to +800°C, s<br>2 x NiCr-Ni K, operating temperature -200 to +1200°C,<br> **Protection tube diameter D in mm**<br>3mm<br>4.5mm<br>6mm<br> **Fitting length EL in mm (50**≤**EL**≤**50000)**<br>100mm<br>200mm<br>300mm<br>400mm<br>500mm<br>please specify in plain text (50mm steps)<br> **Process connection**<br>thread 3/8" pipe<br>thread 1/2" pipe<br> **Extra codes**<br>no extra code<br>uninsulated assembly (thermocouple welded to tip)<br>**(1)**<br>**(2)**<br>**(3)**<br>**(4)**<br>**(5)**<br>-<br>-<br>-<br>-|||||||| ||||||||||| ||||||||||| |**Order example**||901221/40 -|1042 -|6<br>-|200<br>-||||| 1. List extra codes in sequence, separated by commas. 11.03/00073440 ## **JUMO GmbH & Co. KG** ## **JUMO PROCESS CONTROL INC.** ## **JUMO Instrument Co. Ltd.** Delivery address:Mackenrodtstraße 14, JUMO House 885 Fox Chase, Suite 103 36039 Fulda, Germany Temple Bank, Riverway Coatesville PA 19320, USA Postal address: 36035 Fulda, Germany Harlow, Essex CM 20 2TT, UK Phone: 610-380-8002 Phone: +49 661 6003-0 Phone: +44 1279 635533 1-800-554-JUMO Fax: +49 661 6003-607 Fax: +44 1279 635262 Fax: 610-380-8009 e-mail: mail@jumo.net e-mail: sales@jumo.co.uk e-mail: info@JumoUSA.com Internet: www.jumo.net Internet: www.jumo.co.uk Internet: www.JumoUSA.com **==> picture [119 x 43] intentionally omitted <==** **Data Sheet 90.1221 Page 7/7** ## **Stock versions:** |**(1)**||||**(2)**||||**(3)**|||||**(4)**||||**(5)**|Sales No.| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||-||||-||||-||||/||||| |901221/20||-||1043||-||3||-|||100|/|||000|90/00056899| |901221/20||-||1043||-||3||-|||250|/|||000|90/00068440| |**Stock versions:**||||||||||||||||||| |**(1)**|||**(2)**|||**(3)**||**(4)**|||**(5)**|||**(6)**|||**(7)**|Sales No.| ||-|||-|||-|||-|||-|||/||| |901221/32|-|1042||-||6|-|100||-|11||-|2500||/|000|90/00049206| |901221/32|-|1042||-||6|-|200||-|11||-|2500||/|000|90/00068450| |901221/32|-|1042||-||6|-|500||-|11||-|2500||/|000|90/00068452| |901221/32|-|1042||-||3|-|100||-|11||-|2500||/|000|90/00056809| |901221/32|-|1042||-||3|-|200||-|11||-|2500||/|000|90/00068433| |901221/32|-|1042||-||3|-|300||-|11||-|2500||/|000|90/00068434| |901221/32|-|1042||-||3|-|500||-|11||-|2500||/|000|90/00068435| |901221/32|-|1042||-||1.5|-|100||-|11||-|2500||/|000|90/00056811| |901221/32|-|1042||-||1.5|-|200||-|11||-|2500||/|000|90/00068438| |901221/32|-|1042||-||1.5|-|500||-|11||-|2500||/|000|90/00068439| |901221/32|-|1043||-||6|-|100||-|11||-|2500||/|000|90/00056812| |901221/32|-|1043||-||6|-|200||-|11||-|2500||/|000|90/00068427| |901221/32|-|1043||-||6|-|300||-|11||-|2500||/|000|90/00068428| |901221/32|-|1043||-||6|-|500||-|11||-|2500||/|000|90/00068429| |901221/32|-|1043||-||3|-|100||-|11||-|2500||/|000|90/00056813| |901221/32|-|1043||-||3|-|200||-|11||-|2500||/|000|90/00068441| |901221/32|-|1043||-||3|-|300||-|11||-|2500||/|000|90/00068442| |901221/32|-|1043||-||3|-|500||-|11||-|2500||/|000|90/00068443| |901221/32|-|1043||-||1.5|-|100||-|11||-|2500||/|000|90/00049205| |901221/32|-|1043||-||1.5|-|200||-|11||-|2500||/|000|90/00068436| |901221/32|-|1043||-||1.5|-|500||-|11||-|2500||/|000|90/00068437| |901221/32|-|1043||-||0.5|-|100||-|11||-|2500||/|000|90/00066345| |**Stock versions:**||||||||||||||||||| |**(1)**|||**(2)**||||**(3)**|||**(4)**||||**(5)**|||**(6)**|Sales No.| ||-||||-|||-||||-|||/|||| |901221/40|-||1042||-||6|-||100||-||104|/||000|90/00087482| |901221/40|-||1042||-||6|-||300||-||104|/||000|90/00068454| |901221/40|-||1043||-||6|-||100||-||104|/||000|90/00087483| |901221/40|-||1043||-||6|-||200||-||104|/||000|90/00068430| |901221/40|-||1043||-||6|-||300||-||104|/||000|90/00068431| |901221/40|-||1043||-||6|-||500||-||104|/||000|90/00068432| 11.03/00073440
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →