Image not available
Illustrative purposes only
8981-1
Totalizing Counter, Dual Preset, 6 Digit, 14 mm H, 100 to 240 VAC, -20 to 65 °C
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: TRUMETER
- Product type:
- SVHC: No SVHC (04-Feb-2026)
- Digit Height: 14mm
- Product Range: 898X Series
- Panel Cutout Width: 92mm
- Supply Voltage Max: 240VAC
- Supply Voltage Min: 100VAC
- Panel Cutout Height: 45mm
- No. of Digits / Alpha: 6
- Operating Temperature Max: 65°C
- Operating Temperature Min: -20°C
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 298.79 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Model 898X** ## **Electronic Programmable LCD Preset Counter and Rate Indicator** **==> picture [250 x 166] intentionally omitted <==** **----- Start of picture text -----**<br> ——— 96 [3.77] sf max.35 [1.38]<br>7.35 [0.29]<br>11.2 [0.44]<br>= 90.5 [3.56]<br>90 [3.54] 92 [+0.8] [3.622 [+0.031] ]<br>TT 4Ces<br>48 [1.88] 43 [1.69]<br>+0.024]<br> [1.77<br>+0.6<br>45<br>**----- End of picture text -----**<br> The 898X is a counter, tachometer, timer and position display in a single unit. It can be used as a preset counter, batch counter or totalizer depending on requirements, with automatic help text to take the user through programming. With its automatic help text, clearly and legibly displayed on 14 LED segments, the 898X preset counter takes the user effortlessly through the programming. The large user-friendly front keys can be operated even when wearing gloves. The 14mm high LED display ensures easy reading even from a long distance and in poor lighting conditions. Available with RS485 interface and MODBUS and CR/LF protocol ## Key Fetatures ## Benefits - Counter, tachometer, timer and position display in one counter - Can be used as a preset counter, batch counter or total counter - 2 relays (change-over) - Many different count models - Scalable display - Set value, step to tracking preset - Multi-range power supply for AC - Automatic help text - 14-segment LED for improved text representation - Status display of the presets - 3 defined parameters - Tracking presets eliminate the need for re-programming the pre-signal - 4-stage RESET modes - 3-stage keypad locking - Suitable for installation in mosaic systems - Readable or configurable via RS232/485 interface via Modbus or CR/LF protocol - Allows for direct connection of a large display or Printer ## Specifications ## **General Technical Data** **Display** 6-digit red 14 segment LED display, 14mm [0.55] high **Operating Temperature** -20ºC - +65ºC [-4ºF - +149ºF] (non-condensing) **Storage Temperature** -25ºC - +5ºC [-13ºF - +167ºF] **Relative humidity (at +40ºC [+104ºF])** RH 93% (non-condensing) **Altitude** up to 2000m [6562’] ## **Electrical characteristics** **Power Supply** AC 100-240 VAC, +10% max. 11 VA, 50/60 Hz **External Fuse Protection** 230 VAC T0.1 A 10-30 VDC T 0.25 A **Data Retention** >10 years, EEPROM **Response time of the frequency meter** 100 / 600 ms (details in instruction manual) **Input Modes** Count Direction (cnt.dir), _Pulse Counter:_ Difference (up.dn) Addition A+B (up.up) Phase discriminator x1, x2, x4 (quad, quad x2, quad x4), Ratio (A/B), Ratio in % ((A-B)/Ax100%) _Frequency Meter:_ A, A-B, A+B quad, A/B, (A-B)/A x 100% _Timer:_ 4 start modes: FrErun, Auto, InpA.InpB., InpB.InpB. **Sensor power supply** _AC supply:_ 24V DC+ 15%, 80 mA _DC Supply:_ max. 80 mA, external power supply is connected through **EMC** Emitted interference: EN55011 class B Immunity to interference: EN 61000-6-2 **Device safety** Designed to EN 61010 part 1 Protected class 3 Application Area Pollution level 2 ## **Mechanical Data** **Protection** IP65 (from the front) **Weight** approx. 180g [6.35 oz] **Count inputs** A and B **Polarity of the inputs** programmable for all inputs in common, NPN/PNP **Input resistance** 5kΩ **Count frequency** Pulse counters: max. 55kHz Tachometers: max. 65 kHz Can be damped to 30 Hz (mechanical contacts) (details in instruction manual) **Control/Reset input** MPI 1 and MPI 2, Lock, Gate, Reset **Min pulse duration of the inputs** 10 ms/1ms **Switching levels with AC supply** _4-30 VDC_ Low: 0 … 2 VDC High 3.5 … 30 VDC **Switching levels with DC supply** _1-30 VDC_ Low: 0 … 2 VDC High: 3.5 … 30 VDC **Pulse shape** variable, Schmitt-Trigger characteristics ## **Outputs** **Switching voltage** max. 250 VAC / 150 VDC **Switching current** max . 3 A AC / DC min. 30 mA DC **Switching capacity** max. 750 VA / 90 W _**Output 1 + 2**_ **Mech. Service life (switching cycles)** 2 x 10⁷ **No. of switching cycles at 3 A / 250 VAC** 5 x 10⁴ **No. of switching cycles at 3 A / 30 VDC** 5 x 10⁴ **Relay with changeover contact Reaction time of the outputs** 13ms **(pulse / time)** (details in instruction manual) **Optional interface MODBUS and CR/LF Count Frequency** max. 45 kHz 9 (details in instruction manual) **Interface** RS232, RS485 **Baud Rate** 9600 **Device address** 1-99, programmable ## Functions / Count Modes |**Pulse Counter**|• Count with direction mode|• Percentage difference| |---|---|---| ||• Difference mode|measurement (A/B) / A x 100%| ||• Quadrature mode quad / quad2 /|• Batch counting| ||quad4|• Totaliser (overall total)| ||• Add, sub, automatic reset|• Multiplication and division factor| ||• 2-input adding mode A+B|(up to 99.9999)| ||• Ratio measurement A/B|• Set value| ||• Multi-range power supply for AC or|• Step or tracking preset| ||DC|| |**Frequency Meter (tachometer)**|• A|• Averaging| ||• A - B|• Start delay| ||• A + B|• 2nd tacho input| ||• A / B|• Gate input| ||• (A – B) / A x 100% (percentage|• Multiplication and division factor| ||display)|(up to 99.9999)| ||• Quad (phase discriminator with|| ||recognition of direction)|| |**Time and hours-run Meter (timer)**|• FrErun (control via gate input)|• InpA.InpB (start w/ InpA., stop w/| ||• Auto (start via reset, stop at|inpB.)| ||preset)|• Totaliser (overall total)| ||• InpB.InpB (start with the first edge|• Batch counting| ||at InpB (stop with second edge|• Set value| ||InpB.)|• Step or tracking preset| |Part Numbers||| **8980-1:** Dual Preset, Dual Relay Counter, 10-30VDC **8981-1:** Dual Preset, Dual Relay Counter, 100-240VAC **8981-5:** Dual Preset, Dual Relay Counter, 100-240VAC, RS485 **Trumeter (The Americas) Trumeter (Europe)** 6601 Lyons Rd, Suite H-7 Pilot Mill Coconut Creek, Florida Alfred Street FL 33073, Bury, USA BL9 9EF Tel: +1 954 725 6699 Tel: +44 161 674 0960 Email: sales.usa@trumeter.com Email: sales.uk@trumeter.com **Innovative Design Technologies Sdn. Bhd** Lot 5881, Lorong Iks Bukit Minyak 1 Taman Perindustrian Iks, 14000 Bukit Tengah Penang, Malaysia Web: www.idtworld.com Tel: + 604 5015700 Email: sales.my@idtworld.com **www.trumeter.com** 898X-DS-2.0 02/20
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →