Image not available
Illustrative purposes only
88827115.
TIMER, 8A, DIN RAIL
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CROUZET
- Product type: Analogue Timers - DIN Rail
- Product Range:MAR1; TIMER, 8A, DIN RAIL; Product Range:MAR1 Series; Timer Functions:On-Delay; Time Min:0.1s; Time Max:100h; No. of Timing Ranges:7Ranges; Timer Output:1 Changeover Relay; Supply Volta
- SVHC: No SVHC (10-Jun-2022)
- Time Max: 0
- Time Min: 0.1s
- Timer Output: 1 Changeover Relay
- Product Range: MAR1 Series
- Timer Functions: On-Delay
- Current Rating Nom: 8A
- Supply Voltage Max: 240VAC
- No. of Timing Ranges: 0
- Connection / Termination: Screw Terminals
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 49.75 € |
| Current stock | 10+ |
| Lead time | 30 days |
## › **MAR1** › Timers ## ›DIN rail mount ›17.5 mm - 1 Relay 8A - › **Multi-function or mono-function** - › **Multi-range** - › **Multi-voltage** - › **Screw or spring terminals** - › **LED status indicator (relay version)** - › **Possibility of external load connection in parallel to the control input** - › **3-wire PNP sensor compatible** |**Specifications**||||||| |---|---|---|---|---|---|---| |Functions<br>Timing|Output|Nominal rating||Connections|Supply voltage|Code| |A - At<br>0,1 s →100 h|1 changeover|8 A||Screw terminals|24 V DC / 24|88827115| ||relay||||→240 V AC|| |||||||| |**Timing**||||||| |Timing ranges (7 ranges)|||1 s - 10 s - 1 min - 10 min - 1 h - 10 h - 100 h|||| |Repetition accuracy with constant parameters|||± 0.5 % (IEC/EN 61812-1)|||| |Drift Temperature|||± 0,05 % / °C|± 0,05 % / °C||| |Drift Voltage|||± 0,2 % / V|± 0,2 % / V||| |Display accuracy according to IEC/EN 61812-1|||± 10 % / 25 °C|||| |Immunity from micro power cuts : typical|||< 10 ms|||| |Minimum pulse duration typically (relay version)|||30 ms|||| |Minimum pulse duration typically (solid state version)|||50 ms|||| |Minimum pulse duration typically (relay version under load)|||100 ms|||| |Maximum reset time by de-energisation typically (relay version)|||120 ms|||| |Maximum reset time by de-energisation typically (solid state version)|||350 ms|||| |||||||| |**Supply**||||||| |Multi-voltage power supply|||Depending on version|||| |Frequency (Hz)|||50 / 60|||| |Operating factor|||100 %|||| ||||85 →110 % Un|||| |Operating range|||85 →120 % Un for 12 V AC / DC|||| ||||32 VA (240 VAC)|||| ||||1,5 W (240 VDC)|||| |Max. absorbed power|||0,6 W (24 VDC)|||| ||||0,7 VA (12 VAC)|||| ||||0,7 W (12 VDC)|||| **Output specification** ~~ooo~~ Rated power 2000 VA/80 W ~~Oe E Ee~~ **I** Timers **I 02** **I** www.crouzet-control.com ## **Output specification** |**Output specifcation**|**Output specifcation**| |---|---| |Maximum breaking current|8 AAC 250 VAC resistive<br>8 ADC 30 VDC resistive| |Minimum breaking current|10 mA / 5 VDC| |Voltage breaking capacity|250 VAC / 8 AAC resistive<br>250 VDC / 0,3 A resistive| |Electrical life (operations)|10⁵<br>8 A 250 VAC resistive| |Mechanical life (operations)|10 x 10⁶| |Breakdown voltage acc. to IEC/EN 61812-1|2,5 kV / 1 min / 1 mA / 50 Hz| |Impulse voltage acc. to IEC/EN 60664-1, IEC/EN 61812-1|5 kV<br>wave 1.2 / 50 μs| |1 or 2 changeover relays, AgNi (cadmium-free)|1 C/O| ||| |**General characteristics**|| |Conformity to standards|IEC/EN 61812-1<br>IEC/EN 61000-6-1<br>IEC/EN 61000-6-2<br>IEC/EN 61000-6-3<br>IEC/EN 61000-6-4| |Certifcations|CE, UL, cUL, CSA, GL| |Temperature limits use (°C)|-20 →+60| |Temperature limits stored (°C)|-30 →+60| |Installation category (acc. to IEC/EN 60664-1)|Voltage surge category III| |Creepage distance and clearance acc. to IEC/EN 60664-1|4 kV / 3 mm| |Protection (IEC/EN 60529)|IP20| ||IP40| |Degree of protection acc. to IEC/EN 60529 Front face|IP50| |Vibration resistance acc. to IEC/EN 60068-2-6|20 m/s² 10 Hz →150 Hz| |Relative humidity no condensation acc. to IEC/EN 60068-2-30|93 % non-condensing| |Electromagnetic compatibility - Immunity to electrostatic discharges<br>acc to IEC/EN 61000-4-2|Level III (Air 8 kV / Contact 6 kV)| |Immunity to radiated, radio-frequency, electromagnetic feld acc. IEC/<br>EN 61000-4-3|Level I (1 V/m : 2,0 G Hz →2,7 G Hz)<br>Level II (3 V/m : 1,4 G Hz →2,0 G Hz)<br>Level III (10 V/m : 80 M Hz →1 G Hz)| |Immunity to rapid transient bursts acc. to IEC/EN 61000-4-4|Level III (direct 2 kV / Capacitive coupling clamp 1 kV)| |Immunity to shock waves on power supply acc. to IEC/EN 61000-4-5|Level III (2 kV / common mode 2 kV/residual current mode 1 kV)| |Immunity to radio frequency in common mode acc. to<br>IEC/EN 61000-4-6|Level III (10V rms : 0.15 M Hz to 80 M Hz)| |Immunity to voltage dips and breaks acc. to IEC/EN 61000-4-11|0 % residual voltage, 1 cycle<br>70 % residual voltage, 25/30 cycles| |Mains-borne and radiated emissions acc. to EN 55022 (CISPR22),<br>EN55011 (CISPR11)|Class B| |Fixing : Symmetrical DIN rail|35 mm| |Terminal capacity Single-wire without ferrule|1 x 0,5 →3,3 mm² (AWG 20 →AWG 12)<br>2 x 0,5 →2,5 mm² (AWG 20 →AWG 14)| |Terminal capacity Multi-wire with ferrule|1 x 0,5 →2,5 mm² (AWG 20 →AWG 14)<br>2 x 0,5 →1,5 mm² (AWG 20 →AWG 16)| |Housing material|Self-extinguishing| |Shock test IEC/EN 60068-2-27|15 g - 11 ms| |Short interruption on power line acc to IEC/EN 61000-4-11|0 % residual voltage, 250/300 cycles| |Spring terminals, 2 terminals per connection point - fexible wire|2 x 0,5 →1,5 mm² (AWG 20 →AWG 16)| |Spring terminals, 2 terminals per connection point - rigid wire|2 x 0,5 →1,5 mm² (AWG 20 →AWG 16)| **I** Timers **I 03** **I** www.crouzet-control.com |**General characteristics**|**General characteristics**|**General characteristics**|**General characteristics**|**General characteristics**|**General characteristics**|**General characteristics**|**General characteristics**|**General characteristics**|||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Weight : casing 17,5 mm||||||||||88827105 (MUR1) : 63 g<br>88827115 (MAR1) : 63 g<br>88827125 (MBR1) : 63 g<br>88827135 (MCR1) : 62 g<br>88827145 (MHR1) : 63 g<br>88827150 (MLR4) : 63 g<br>88827155 (MLR1) : 64 g<br>88827100 (MUR4) : 62 g<br>88827103 (MUR3) : 66 g<br>88827503 (MURc3) : 59 g<br>88827150 (MLR4) : 63 g<br>88827185 (MXR1) : 63 g<br>88827004 (MUS2) : 55 g<br>88827014 (MAS5) : 53 g<br>88827044 (MHS2) : 53 g<br>88827054 (MLS2) : 56 g|||| |Insulation resistance according to IEC/EN 60664-1||||||||||100 MOhm(s) (500 V DC)|||| ||||||||||||||| |**Dimensions**|||||||||||||| |67,5<br>45<br>3||,5||60|||5,5|17|,5<br>90<br>2,6||||| ||||||44||||||||| ||||||23,2||||||||| ||||||||||||||| ||||||||||90<br>2,6||||| ||||||||||||||| ||45||||||||||||| ||||||||||||||| ||||||||||||||| ||||||||||||||| ||||||||||||||| ||||||||||||||| ||||||||||||||| |**Curves**<br>|||||||||||||| |Function A<br>Delay on energisation 1 relay<br>U<br>R<br>|||||||||||||| ||||||||||||T||| |Function At<br>Timing on energisation with memory 1 relay<br>U<br>C<br>R|||||||||||||| ||||||||||||||| ||||||||||||||| |**Connections**|||||||||||||| |1 changeover relay output<br>+||||||||||U<br>A<br>A<br>|1<br>R<br>15<br>2<br>18<br>16<br>Y1||| |**Curves**|||||||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Function A|U||||||||||||||||| |Delay on energisation 1 relay|R|||||T|||||||||||| |Function At|U||||||||||||||||| |Timing on energisation with memory 1 relay|C<br>R||||||||||||||||| ||||||t1|||||||t2|||||| ||||||||||T|=||t1+t2|||||| ||||||||||||||||||| |**Connections**|||||||||||||||||| |1 changeover relay output|+||U||||||||||||||| ||||A1|||Y1||||R<br>15|||||||| ||||||||||||||||||| ||||A2||||||||||||||| ||||||||||16|||18|||||| **I** Timers **I 04 I** www.crouzet-control.com ## **Connections** **==> picture [239 x 105] intentionally omitted <==** **----- Start of picture text -----**<br> IEC61812-1TU : 0,1s-100h: 24-240VAC 50-60Hz 32VA 24VDC 0,6W: 8A/250V<br>t eu? fom<br>Made in Indonesia ——— S N MAR1<br>- Use copper conductors only<br>TORQUE: 6mm 6mm<br>VP 0,6...1N.m5.3...8.8lbf.in 2x 20...14AWG0,5...2,5mm [2] 2x 0,5...1,5mm20...16AWG2 eee<br>US 44UF<br>C LISTED IND.CONT. EQ.<br>**----- End of picture text -----**<br>
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →