Image not available
Illustrative purposes only
86.00.0.240.0000
Analogue Timer, Module, 86 Series, Multifunction, 1 Ranges, 0.05 s, 100 h
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: FINDER
- Product type: Analogue Timers
- Product Range:86 Series; Timer Functions:Multifunction; No. of Timing Ranges:1Ranges; Time Min:0.05s; Time Max:100h; Timer Output:-; Supply Voltage Max:240VAC; Current Rating Nom:-; Connection / Ter
- SVHC: No SVHC (04-Feb-2026)
- Time Max: 100h
- Time Min: 0.05s
- Timer Output: -
- Product Range: 86 Series
- Timer Functions: Multifunction
- Current Rating Nom: -
- Panel Cutout Width: -
- Supply Voltage Max: 240VAC
- Panel Cutout Height: -
- No. of Timing Ranges: 1Ranges
- Connection / Termination: Plug-In
| Delivery and price | |
|---|---|
| Units per pack | 20 |
| Price | 39.07 € |
| Current stock | 500+ |
| Lead time | 30 days |
**86 SERIES**
|**Timer modules for use in conjunction with**<br>**relay & socket.**<br>**86.00 - Multi-function & multi-voltage timer**<br>**module**<br>**86.30 - Bi-function & multi-voltage timer module**<br>•Timer module type 86.00 for 90, 92, 96<br>series sockets and type 86.30 for 90, 92, 94, 95,<br>96, 97 series sockets<br>•Wide supply voltage range:<br>12…240 V AC/DC (86.00)<br>12…24 V AC/DC or 230…240 V AC (86.30)<br>•LED indicator<br>86.00<br>86.30<br>**Contact specification**<br>Contact configuration<br>38ns<br>~~i~~i<br>miei<br>Wu<br>10~~.~~5|6.3<br>15.5<br>11.3<br>CU<br>UD<br>2<br>0.5<br>1.05 ‘|<br>3.8 Lt |<br>4~~.~~25<br>87~~5~~|**86.00**<br>•Time scale: from 0.05 s to 100 h<br>•Multi-function<br>•Plug-in for use with 90.02, 90.03, 92.03 and<br>96.04 sockets<br>=<br>| {l) [f<br>=<br>t|**86.00**<br>•Time scale: from 0.05 s to 100 h<br>•Multi-function<br>•Plug-in for use with 90.02, 90.03, 92.03 and<br>96.04 sockets<br>=<br>| {l) [f<br>=<br>t|**86.30**<br>•Time scale: from 0.05 s to 100 h<br>•Bi-function<br>•Plug-in for use with 90.02, 90.03, 92.03, 94.P3,<br>94.P4, 94.02, 94.03, 94.04, 95.P3, 95.P5, 95.03,<br>95.05, 96.02, 96.04, 97.P1, 97.P2, 97.01 and<br>97.02 sockets|**86.30**<br>•Time scale: from 0.05 s to 100 h<br>•Bi-function<br>•Plug-in for use with 90.02, 90.03, 92.03, 94.P3,<br>94.P4, 94.02, 94.03, 94.04, 95.P3, 95.P5, 95.03,<br>95.05, 96.02, 96.04, 97.P1, 97.P2, 97.01 and<br>97.02 sockets|**86.30**<br>•Time scale: from 0.05 s to 100 h<br>•Bi-function<br>•Plug-in for use with 90.02, 90.03, 92.03, 94.P3,<br>94.P4, 94.02, 94.03, 94.04, 95.P3, 95.P5, 95.03,<br>95.05, 96.02, 96.04, 97.P1, 97.P2, 97.01 and<br>97.02 sockets|
|---|---|---|---|---|---|
||**AI:**On-delay<br>**DI:**Interval<br>**SW:**Symmetrical flasher (starting pulse on)<br>**BE:**Off-delay with control signal<br>**CE:**On- and off-delay with control signal<br>**DE:**Interval with control signal on<br>**EE:**Interval with control signal off<br>**FE:**Interval with control signal on and off<br>Relay + socket<br>Wiring diagram<br>(without control signal)<br>Relay + socket<br>Wiring diagram<br>(with control signal)<br>See 56, 60 and 62 series relays<br>Note: Do not use with relays<br>62.3x.x012.x300 and 62.3x.x012.x600<br>12…240<br>H A2<br>Al<br>Bi1<br>:<br>H A2<br>A1<br>Bi<br>:<br>“pe<br>Orr “en<br>(<br>Ss<br>N~~im~~ Li+<br>~~Ne~~ Lit||**AI:**On-delay<br>**DI:**Interval<br>Relay + socket<br>Wiring diagram<br>See 40, 44, 46, 55, 56, 60 and<br>62 series relays<br>12…24<br>110…125<br>230…240<br>i A2<br>Al<br>:<br>~on<br>(<br>~~Ni~~ Lit|||
|Rated current/Maximum peak current<br>A||||||
|Rated voltage/<br>Maximum switchingvoltage<br>V AC||||||
|Rated load AC1<br>VA||||||
|Rated load AC15 (230 V AC)<br>VA||||||
|Single phase motor rating (230 V AC)<br>kW||||||
|Breaking capacityDC1: 30/110/220 V<br>A||||||
|Minimum switching load<br>mW (V/mA)||||||
|Standard contact material<br>**Supply specification**<br>Nominal voltage (UN)<br>V AC (50/60 Hz)<br>V DC||||||
||12…240||12…24|—|—|
|Rated power AC/DC<br>W|1.2||0.15|||
|Operating range<br>V AC (50/60 Hz)<br>DC<br>**Technical data**<br>Specified time range|10.2…265||9.6…33.6|88…137|184…265|
||10.2…265<br>9.6…33.6<br>—<br>—<br>(0.05…1)s, (0.5…10)s, (5…100)s, (0.5…10)min, (5…100)min, (0.5…10)h, (5…100)h|||||
|Repeatability<br>%|± 1||± 1|||
|Recoverytime<br>ms|≤ 50||≤ 50|||
|Minimun control impulse<br>ms|50||—|||
|Setting accuracyfull range<br>%|± 5||± 5|||
|Electrical life at rated load in AC1<br>cycles|See 56, 60 and 62 series relays||See 40, 44, 46, 55, 56, 60 and 62 series relays|||
|Ambient temperature range<br>°C|–20…+50||–20…+50|||
|Protection category|IP 20||IP 20|||
|**Approvals**(according to type)|C€<br>EAL|EAL|EAL AXus|||
**H**
**1**
**86 SERIES**
## **Ordering information**
Example: 86 series multi-function timer module, (12…240)V AC/DC supply voltage.
## **8 6 . 0 0 . 0 . 2 4 0 . 0 0 0**
**0**
## **Series**
## **Type**
0 = Multi-function (AI, DI, SW, BE, CE, DE, EE, FE) 3 = Bi-function (AI, DI)
## **No. of poles**
See 40, 44, 46, 55, 56, 60 and 62 series relays Poles for chosen relay/socket combination - according to chart below
**Supply voltage** 024 = (12…24)V AC/DC (86.30 only) 120 = (110…125)V AC (86.30 only) 240 = (12…240)V AC/DC (86.00 only) 240 = (230…240)V AC (86.30 only) **Supply version** 0 = AC (50/60 Hz)/DC 8 = AC (50/60 Hz)
## **Combinations**
**==> picture [421 x 16] intentionally omitted <==**
**----- Start of picture text -----**<br>
Number of poles Relay type Socket type Timer module<br>**----- End of picture text -----**<br>
|**Number of poles**|**Relay type**|**Socket type**|**Timer module**|
|---|---|---|---|
|1|40.31|95.P3/95.03|86.30|
|1|40.61|95.P5/95.05|86.30|
|1|46.61|97.P1/97.01|86.30|
|2|40.52/44.52/44.62|95.P5/95.05|86.30|
|2|46.52|97.P2/97.02|86.30|
|2|55.32|94.P4/94.02|86.30|
|2|56.32|96.02|86.30|
|2|60.12|90.02|86.00/86.30|
|2|62.32|92.03|86.00/86.30|
|3|55.33|94.P3/94.03|86.30|
|3|60.13|90.03|86.00/86.30|
|3|62.33|92.03|86.00/86.30|
|4|55.34|94.P4/94.04|86.30|
|4|56.34|96.04|86.00/86.30|
**H**
## **Technical data**
## **EMC specifications**
|**Type of test**||**Reference standard**|**86.00**|**86.30**|
|---|---|---|---|---|
|Electrostatic discharge|contact discharge|EN 61000-4-2|4 kV|n.a.|
||air discharge|EN 61000-4-2|8 kV|8 kV|
|Radio-frequencyelectromagnetic field (80 ÷|1000 MHz)|EN 61000-4-3|10 V/m|10 V/m|
|Fast transients (burst) (5-50 ns, 5 kHz) on Supplyterminals||EN 61000-4-4|4 kV|2 kV|
|Surges (1.2/50 µs) on Supply terminals|common mode|EN 61000-4-5|4 kV|2 kV|
||differential mode|EN 61000-4-5|4 kV|1 kV|
|Radio-frequency common mode (0.15 ÷ 80 MHz)<br>on Supplyterminals||EN 61000-4-6|10 V|10 V|
|Radiated and conducted emission||EN 55022|class B|class B|
|**Other data**||**86.00**|**86.30**||
|Current absorption on signal control (B1)|mA|1|—||
|Power lost to the environment|without contact current<br>W|0.1 (12 V) - 1 (230 V)|0.2||
||with rated current|See 56, 60 and 62 series relays|See 40, 44, 46, 55, 56, 60, 62 series<br>relays||
## **Times scales**
**==> picture [408 x 41] intentionally omitted <==**
NOTE: Time scales and functions must be set before energising the timer.
To achieve the minimum time setting of 0.05 seconds it is necessary to use one of the functions with control signal. When setting very short times it may be necessary to take into account the operate time of the relay used.
**2**
**86 SERIES**
## **Functions**
|**U**= Supply voltage<br>**S**= Signal switch<br> = Output contact||LED<br>Type 86.00|LED<br>Type 86.30|Supply<br>voltage|NO output<br>contact|
|---|---|---|---|---|---|
|||||OFF|Open|
|||||ON|Open|
|||||ON|Open<br>(Timingin Progress)|
|||||ON|Closed|
||Withoutcontrol signal= Start via contact in supply line (A1).<br>Withcontrol signal= Start via contact into control terminal (B1).|||||
**==> picture [510 x 453] intentionally omitted <==**
**----- Start of picture text -----**<br>
Wiring diagram Type 86.00<br>Without control signal (AI) On-delay.<br>Apply power to timer. Output contacts transfer after preset<br>time has elapsed. Reset occurs when power is removed.<br>(DI) Interval.<br>Apply power to timer. Output contacts transfer immediately.<br>After the preset time has elapsed, contacts reset.<br>(SW) Symmetrical flasher (starting pulse on).<br>Apply power to timer. Output contacts transfer immediately<br>and cycle between ON and OFF for as long as power is<br>applied. The ratio is 1:1 (time on = time off).<br>With control signal (BE) Off-delay with control signal.<br>Power is permanently applied to the timer.<br>The output contacts transfer immediately on closure of the<br>Signal Switch (S). Opening the Signal Switch initiates the preset<br>delay, after which time the output contacts reset.<br>(CE) On- and off-delay with control signal.<br>* Power is permanently applied to the timer.<br>Closing the Signal Switch (S) initiates the preset delay, after<br>which time the output contacts transfer. Opening the Signaltime the output contacts transfer. Opening the Signal<br>switch initiates the same preset delay, after which time the<br>* With DC supply,<br>output contacts reset.<br>positive polarity has<br>(DE) Interval with control signal on.<br>to be conneted to B1<br>Power is permanently applied to the timer.<br>terminal (according to<br>On momentary or maintained closure of Signal Switch (S),<br>EN 60204-1).<br>the output contacts transfer, and remain so for the duration<br>Switch S should be<br>of the preset delay, after which they reset.<br>exclusively used to<br>(EE) Interval with control signal off.<br>provide the control<br>Power is permanently applied to the timer.<br>signal to terminal B1.<br>On opening of the Signal Switch (S) the output contacts<br>(Do not connect any<br>transfer, and remain so for the duration of the preset delay,<br>other load at this point).<br>after which they reset.<br>(FE) Interval with control signal on and off.<br>Power is permanently applied to the timer.<br>Both the opening and closing of the Signal Switch (S)<br>initiates the transfer of the output contacts. In both instances<br>the contacts reset after the delay period has elapsed.<br>**----- End of picture text -----**<br>
> Closing the Signal Switch (S) initiates the preset delay, after **H** which time the output contacts transfer. Opening the Signaltime the output contacts transfer. Opening the Signal switch initiates the same preset delay, after which time the output contacts reset.
**Wiring diagram Type 86.30**
**==> picture [63 x 88] intentionally omitted <==**
**==> picture [178 x 86] intentionally omitted <==**
## **(AI) On-delay.**
Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed.
## **(DI) Interval.**
Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset.
**3**
**86 SERIES**
## **H**
**==> picture [504 x 507] intentionally omitted <==**
**----- Start of picture text -----**<br>
Screw terminal (Box clamp) socket 90.02 90.02.0 90.03 90.03.0<br>panel or 35 mm rail (EN 60715) mount Blue Black Blue Black<br>For relay type 60.12 60.13<br>Accessories<br>Metal retaining clip 090.33<br>6-way jumper link 090.06<br>90.03 Identification tag 090.00.2<br>Approvals Timer module 86.00, 86.30<br>(according to type): Technical data<br>C€ @ FAL Adis Double terminal A1 (for easy start connection)<br>2) Rated values 10 A - 250 V<br>Dielectric strength 2 kV AC<br>Protection category IP 20<br>Ambient temperature °C –40…+70<br>© Screw torque Nm 0.6<br>Wire strip length mm 10<br>Max. wire size for 90.02 and 90.03 sockets Po solid wire stranded wire<br>mm [2] Po 1 x 6 / 2 x 2.5 1 x 4 / 2 x 2.5<br>AWG Po 1 x 10 / 2 x 14 1 x 12 / 2 x 14<br>38 81.1<br>NC NC NO ad -s n -3 el NO NC NO NC NO NC ed = ed el = el<br>NO et an t {———* " J<br>eke) | sete) . PI reninininin:<br>COIL COM COIL COM COIL oe) eee oo a cou SARIOOM COL eeeece 5<br>90.02<br>; a y 9 0 . 03 =e 30.5 im 26.9<br>9 0.03<br>90.02 33.5<br>90.03 90.03 + 60.13 + 86.00<br>6-way jumper link for 90.02 and 90.03 sockets 090.06<br>= EZ Rated values 190 10 A - 250 V<br>090.06<br>Approvals<br>49.5 15 23 15 23 15 49.5<br>(according to type): ~ LL<br>P E A<br>P A T E N T<br>RO N<br>U<br>E<br>20.4<br>77.5 35.5<br>3.2<br>34.8<br>21.6<br>4<br>E<br>U<br>NA E POR<br>**----- End of picture text -----**<br>
**4**
**86 SERIES**
**H**
**==> picture [453 x 211] intentionally omitted <==**
**----- Start of picture text -----**<br>
||||||
|---|---|---|---|---|
|Screw terminal (Box clamp) socket|92.03|92.03.0|
|panel or 35 mm rail (EN 60715) mount|Blue|Black|
|For relay type|62.32, 62.33|
|Accessories|
|Metal retaining clip|
|92.03|(supplied with socket - packaging code SMA)|092.71|
|Approvals|Identification tag|092.00.2|
|(according to type):|Timer modules|86.00, 86.30|
|C€|@|FAL|Ais|Technical data|
|Rated values|16 A - 250 V|
|Dielectric strength|6 kV (1.2/50 µs) between coil and contacts|
|Protection category|IP 20|
|Ambient temperature|°C|–40…+70 (see diagram L92)|
|©|Screw torque|Nm|0.8|
|Wire strip length|mm 10|
|Max. wire size for 92.03 socket|Po|solid wire|stranded wire|
|mm|[2]|Po|1 x 10 / 2 x 4|1 x 6 / 2 x 4|
|AWG|Po|1 x 8 / 2 x 12|1 x 10 / 2 x 12|
**----- End of picture text -----**<br>
## **L 92 - Rated current v ambient temperature**
**==> picture [7 x 50] intentionally omitted <==**
**----- Start of picture text -----**<br>
Rated current (A)<br>**----- End of picture text -----**<br>
**==> picture [205 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
78.5<br>40 60.9<br>35.5 30.3<br>27 27<br>Pe |<br>i<br>© © @| d OL<br>— rere<br>Pao a coal ERESESESEEEE<br>= CEE<br>“| ord B e e<br>fomme==~ D J<br>32 92.03 + 62.33 + 86.30<br>3<br>4.<br>3<br>3.2<br>91.3 .4<br>35<br>46.3<br>21.6<br>**----- End of picture text -----**<br>
**5**
**86 SERIES**
**==> picture [11 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
H<br>**----- End of picture text -----**<br>
|**Push-in terminal socket**panel or 35 mm<br>(EN 60715) rail mount<br>For relay type||**94.P3**<br>**Blue**<br>55.33|**94.P4**<br>**Blue**<br>55.32, 55.34|**94.P4**<br>**Blue**<br>55.32, 55.34|
|---|---|---|---|---|
|**Accessories**<br>Metal retainingclip||094.71|||
|Plastic retaining and release clip<br>(supplied with socket-packaging code SPA)||094.91.3|||
|6-way jumper link<br>Identification tag<br>2-way jumper link||094.56<br>094.00.4<br>094.52.1|||
|2-way jumper link||097.52|||
|Marker tagholder<br>Timer modules(see table below)||097.00<br>86.30|||
|Sheet of marker tags for plastic retaining and release clip<br>094.91.3 and for marker tag holder 097.00 , 48 tags, 6 x 12 mm<br>for CEMBRE thermal transfer printers<br>**Technical data**|094.91.3 and for marker tag holder 097.00 , 48 tags, 6 x 12 mm|060.48|||
|Rated values||10 A - 250 V|||
|Dielectric strength||2 kV AC|||
|Protection category||IP 20|||
|Ambient temperature|°C|–40…+70|||
|Wire striplength|mm|8|||
|Min. wire size for 94.P3 and 94.P4 sockets||solid wire||stranded wire|
||mm2|0.5||0.5|
||AWG|21||21|
|Max. wire size for 94.P3 and 94.P4 sockets||solid wire||stranded wire|
||mm2|2 x 1.5 / 1 x 2.5<br>~~—__~~||2 x 1.5 / 1 x 2.5|
||AWG|2 x 18 / 1 x 14||2 x 18 / 1 x 14|
**==> picture [21 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
94.P4<br>**----- End of picture text -----**<br>
Approvals (according to type):
Certain relay/socket combinations
**==> picture [31 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
094.91.3<br>**----- End of picture text -----**<br>
**==> picture [25 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
060.48<br>**----- End of picture text -----**<br>
94.P3 94.P4 **6-way jumper link** for 94.P3 and 94.P4 sockets 094.56 (blue) Rated values 10 A - 250 V ZF 31 31 31 31 31 a) Gee Oh hee ~ 161.6 5.6 **2-way jumper link** for 94.P3 and 94.P4 sockets 094.52.1 Rated values 10 A - 250 V 2 304 5. 9, Looe o ~~l~~ 2 ~~75 2~~ 6 **2-way jumper link** for 94.P3 and 94.P4 sockets 097.52 Rated values 10 A - 250 V ~~2~~ 42 ~~!~~ ~s, 5 ~~.~~ **Marker tag holder** ~~15.6,~~ - 4 ~~4~~ for 94.P3 and 94.P4 sockets 097.00 | e ~~s t~~ **86 series timer modules** (12…24)V AC/DC; Bi-function: AI, DI; (0.05 s…100 h) 86.30.0.024.0000 (110…125)V AC; Bi-function: AI, DI; (0.05 s…100 h) 86.30.8.120.0000 (230…240)V AC; Bi-function: AI, DI; (0.05 s…100 h) 86.30.8.240.0000 : ~~ot~~ **86.30** Approvals (according to type): cAL
**==> picture [84 x 51] intentionally omitted <==**
**----- Start of picture text -----**<br>
ZF<br>094.56<br>P E<br>P A T E N T<br>RO AN<br>U<br>E<br>E<br>U<br>NA E POR<br>**----- End of picture text -----**<br>
**==> picture [31 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
094.52.1<br>**----- End of picture text -----**<br>
**097.52 097.00**
**6**
**86 SERIES**
|**Screw terminal (Box clamp) socket**panel or 35 mm<br>(EN 60715) rail mount<br>For relay type<br>**Accessories**<br>Metal retainingclip|panel or 35 mm<br>**94.02**<br>**Blue**<br>**94.02.0**<br>**Black**<br>**94.03**<br>**Blue**<br>**94.03.0**<br>**Black**<br>**94.04**<br>**Blue**<br>**94.04.0**<br>**Black**<br>55.32<br>55.33<br>55.32, 55.34<br>094.71|panel or 35 mm<br>**94.02**<br>**Blue**<br>**94.02.0**<br>**Black**<br>**94.03**<br>**Blue**<br>**94.03.0**<br>**Black**<br>**94.04**<br>**Blue**<br>**94.04.0**<br>**Black**<br>55.32<br>55.33<br>55.32, 55.34<br>094.71|panel or 35 mm<br>**94.02**<br>**Blue**<br>**94.02.0**<br>**Black**<br>**94.03**<br>**Blue**<br>**94.03.0**<br>**Black**<br>**94.04**<br>**Blue**<br>**94.04.0**<br>**Black**<br>55.32<br>55.33<br>55.32, 55.34<br>094.71|panel or 35 mm<br>**94.02**<br>**Blue**<br>**94.02.0**<br>**Black**<br>**94.03**<br>**Blue**<br>**94.03.0**<br>**Black**<br>**94.04**<br>**Blue**<br>**94.04.0**<br>**Black**<br>55.32<br>55.33<br>55.32, 55.34<br>094.71|panel or 35 mm<br>**94.02**<br>**Blue**<br>**94.02.0**<br>**Black**<br>**94.03**<br>**Blue**<br>**94.03.0**<br>**Black**<br>**94.04**<br>**Blue**<br>**94.04.0**<br>**Black**<br>55.32<br>55.33<br>55.32, 55.34<br>094.71|
|---|---|---|---|---|---|
|Plastic retaining and release clip<br>(supplied with socket -packagingcode SPA)|094.91.3 094.91.30|094.91.30 094.91.3 094.91.30|094.91.30 094.91.3|094.91.3|094.91.30|
|6-way jumper link|094.06<br>094.06.0|094.06.0 094.06<br>094.06.0|094.06.0 094.06|094.06|094.06.0|
|Identification tag<br>Marker tagholder|094.00.4<br>097.00|||||
|Marker tagholder<br>Timer modules(see table below)|097.00<br>86.30|||||
|Sheet of marker tags for plastic retaining and release clip<br>094.91.3 and for marker tag holder 097.00 , 48 tags, 6 x 12 mm<br>for CEMBRE thermal transfer printers<br>**Technical data**<br>Rated values|Sheet of marker tags for plastic retaining and release clip<br>094.91.3 and for marker tag holder 097.00 , 48 tags, 6 x 12 mm<br>060.48<br>10 A - 250 V|||||
|Dielectric strength|2 kV AC|||||
|Protection category|IP 20|||||
|Ambient temperature|°C –40…+70|||||
|Screw torque|Nm 0.5|||||
|Wire striplength|mm 8|||||
|Max. wire size for 94.02/03/04 sockets|solid wire<br>mm2 1 x 6 / 2 x 2.5<br>AWG 1 x 10 / 2 x 14<br>~~Pp~~||stranded wire|||
||||1 x 4 / 2 x 2.5|||
||||1 x 12 / 2 x 14|||
**94.04**
Approvals (according to type):
Certain relay/socket combinations
**094.91.3**
## **060.48**
Top 86 ~~.~~ 9 ~~27 termi~~ nals 60 ~~.~~ 9 ~~-—+ oo O~~ OO , F : = ~~e~~ ra) [I ¢ 1 oo A a U ~~|.Oc~~ ~~**o** nf~~ N —— 94.04 —S Bottom 7 35.5 **H** terminals 094.06 (blue) 094.06.0 (black) 10 A - 250 V
**==> picture [271 x 62] intentionally omitted <==**
**----- Start of picture text -----**<br>
6-way jumper link for 94.02, 94.03 and 94.04 sockets<br>Rated values<br>ZF 2 135 et e<br>erat<br>094.06 | Spa ELE REED SEED S<br>P E<br>P A T E N T<br>RO AN<br>U<br>E<br>E<br>U<br>NA E POR<br>**----- End of picture text -----**<br>
## **86 series timer modules**
|(12…24)V AC/DC;Bi-function: AI,DI; (0.05 s…100 h)<br>86.30.0.024.0000|86.30.0.024.0000|
|---|---|
|(110…125)V AC;Bi-function: AI,DI; (0.05 s…100 h)<br>86.30.8.120.0000|86.30.8.120.0000|
|(230…240)V AC;Bi-function: AI,DI; (0.05 s…100 h)<br>86.30.8.240.0000|86.30.8.240.0000|
Approvals (according to type):
## **86.30**
**7**
**86 SERIES**
|**Push-in terminals socket**panel or 35 mm rail mount<br>For relay type<br>**Accessories**<br>Metal retainingclip|**95.P3**<br>**95.P5**<br>40.31<br>40.51/ 52/ 61, 44.52/62<br>095.71|**95.P3**<br>**95.P5**<br>40.31<br>40.51/ 52/ 61, 44.52/62<br>095.71|
|---|---|---|
|Plastic retaining and release clip<br>(supplied with socket-packaging code SPA)|095.91.3||
|8-way jumper link|097.58||
|2-way jumper link(12.5 mmpitch)|097.52||
|2-way jumper link(4.6 mmpitch)|097.42||
|Marker tagholder(for tags 060.48 type)|097.00||
|Timer modules(see table below)|86.30||
|Identification tag|095.00.4||
|Sheet of marker tags for plastic retaining and release clip<br>095.91.3 and for marker tag holder 097.00, 48 tags,<br>6 x 12 mm, for CEMBRE thermal transfert printer<br>**Technical data**<br>Rated values|060.48<br>10 A - 250 V*||
|Dielectric strength|6 kV(1.2/50µs)between coil and contacts||
|Protection category|IP 20||
|Ambient temperature<br>°C|–40…+70(see diagram L95)||
|Wire striplength<br>mm|8||
|Min. wire size for 95.P3 and 95.P5 sockets<br>mm2 <br>AWG|solid wire|stranded wire|
||0.5|0.5|
||21|21|
|Max. wire size for 95.P3 and 95.P5 sockets<br>mm2 <br>AWG|solid wire|stranded wire|
||2 x 1.5/1 x 2.5|2 x 1.5/1 x 2.5|
||2 x 18/1 x 14|2 x 18/1 x 14|
## **L 95 - Total socket current v ambient temperature**
**==> picture [445 x 421] intentionally omitted <==**
**----- Start of picture text -----**<br>
oo 11 COM com<br>a 14 NO<br>a<br>es a 12 NC ” Ne<br>a a f ° s les<br>a a a G =: B i e Fh<br>H a ot] 2 0a0 | 20| afy 40fp ty yy60 80| A2 P A1 COIL i 5 con ~— #3 4<br>(°C) 95.P3 95.P5<br>8-way jumper link for 95.P3 and 95.P5 sockets 097.58<br>Rated values 10 A - 250 V<br>cS© P ) AA[LAL5.8 4BALLBSBA 3*<br>097.58 L. 117.2 | a 5 . 6<br>2-way jumper link for 95.P3 and 95.P5 sockets 097.52<br>Rated values 10 A - 250 V<br>betc a . n<br>ff 7;<br>097.52<br>a m<br>2-way jumper link for 95.P3 and 95.P5 sockets 097.42<br>Rated values 10 A - 250 V<br>f 8 46<br>097.42<br>7 7 ,<br>@Q Marker tag holder ve for 95.P3 and 95.P5 sockets | 097.00<br>097.00 = t<br>86 series timer modules<br>(12…24)V AC/DC; Bi-function: AI, DI; (0.05 s…100 h) 86.30.0.024.0000<br>(110…125)V AC; Bi-function: AI, DI; (0.05 s…100 h) 86.30.8.120.0000<br>(230…240)V AC; Bi-function: AI, DI; (0.05 s…100 h) 86.30.8.240.0000<br>e 86.30 °<br>Approvals (according to type): C€ EAL Adis<br>Total socket current (A)<br>**----- End of picture text -----**<br>
**8**
**86 SERIES**
|**Screw terminal (Box clamp) socket**panel or 35 mm rail mount<br>For relay type<br>**Accessories**<br>Metal retainingclip|panel or 35 mm rail mount<br>**95.03 (blue)**<br>**95.03.0 (black) 95.05 (blue)**<br>**95.05.0 (black)**<br>40.31<br>40.51, 40.52, 40.61<br>095.71|panel or 35 mm rail mount<br>**95.03 (blue)**<br>**95.03.0 (black) 95.05 (blue)**<br>**95.05.0 (black)**<br>40.31<br>40.51, 40.52, 40.61<br>095.71|panel or 35 mm rail mount<br>**95.03 (blue)**<br>**95.03.0 (black) 95.05 (blue)**<br>**95.05.0 (black)**<br>40.31<br>40.51, 40.52, 40.61<br>095.71|panel or 35 mm rail mount<br>**95.03 (blue)**<br>**95.03.0 (black) 95.05 (blue)**<br>**95.05.0 (black)**<br>40.31<br>40.51, 40.52, 40.61<br>095.71|
|---|---|---|---|---|
|Plastic retaining and release clip<br>supplied with socket -packagingcode SPA)|095.01|095.01.0|095.01<br>095.01.0|095.01.0|
|8-way jumper link|095.18|095.18.0|095.18<br>095.18.0|095.18.0|
|Marker tagholder(for tags 060.48 type)|097.00||||
|Identification tag|095.00.4||||
|Timer modules(see table below)|86.30||||
|Sheet of marker tags for plastic retaining and release clip<br>095.01 and for marker tag holder 097.00, 48 tags, 6 x 12 mm,<br>for CEMBRE thermal transfer printers<br>**Technical data**<br>Rated values|mm,<br>060.48<br>10 A - 250 V*||||
|Dielectric strength|6 kV(1.2/50µs)between coil and contacts||||
|Protection category|IP 20||||
|Ambient temperature|°C –40…+70(see diagram L95)||||
|Screw torque<br>Nm|Nm 0.5||||
|Wire striplength<br>mm|mm 8||||
|Max. wire size for 95.03 and 95.05 sockets<br>mm<br>AWG|solid wire<br>mm2 1 x 6 / 2 x 2.5<br>~~|~~||stranded wire||
||||1 x 4 / 2 x 2.5||
||AWG 1 x 10 / 2 x 14<br>~~|~~||1 x 12 / 2 x 14||
## **L 95 - Total socket current v ambient temperature**
**==> picture [484 x 238] intentionally omitted <==**
**----- Start of picture text -----**<br>
pg a — —<br>11 COM<br>egoa NOa SO a OS 14 NO 'cow |+<br>a a a ON<br>12 NC<br>eLEag EPa 3 ee | - Cl ose e gRIS[ seE lon§3 :<br>ag a aOO cal cal i<br>a a Sel el tet<br>ol - 20 tL}0 | 20tt 40py tp60 ty80 A2 A1 COIL L—-él col Tral a i :<br>ry 32<br>(°C) 95.03 158, 95.05 usa 2.<br>8-way jumper link for 95.03 and 95.05 sockets 095.18 (blue) 095.18.0 (black)<br>Rated values 10 A - 250 V<br>GZ % 110.5 5A<br>095.18<br>P tH tH a tc te a a or)<br>15 15.8 15 . 8 15 . 8 15 . 8 15.8 15 °<br>86 series timer modules<br>= (12…24)V AC/DC; Bi-function: AI, DI; (0.05 s…100 h) 86.30.0.024.0000<br>(110…125)V AC; Bi-function: AI, DI; (0.05 s…100 h) 86.30.8.120.0000<br><a (230…240)V AC; Bi-function: AI, DI; (0.05 s…100 h 6 ) 86.30.8.240.0000<br>Approvals (according to type):<br>P E A<br>P A T E N T<br>RO N<br>U<br>E<br>Total socket current (A)<br>E<br>U<br>NA E POR<br>**----- End of picture text -----**<br>
**==> picture [10 x 10] intentionally omitted <==**
**----- Start of picture text -----**<br>
H<br>**----- End of picture text -----**<br>
**==> picture [21 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
86.30<br>**----- End of picture text -----**<br>
**9**
**86 SERIES**
|**Screw terminal (Box clamp) socket**<br>panel or 35 mm rail (EN 60715) mount<br>For relay type<br>**Accessories**<br>Metal retaining clip<br>(supplied with socket -packagingcode SMA)|**96.02**<br>**Blue**<br>**96.02.0**<br>**Black**<br>**96.04**<br>**Blue**<br>56.32<br>56.34<br>094.71<br>096.71<br>|<br>~~ee~~|**96.02**<br>**Blue**<br>**96.02.0**<br>**Black**<br>**96.04**<br>**Blue**<br>56.32<br>56.34<br>094.71<br>096.71<br>|<br>~~ee~~|**96.04**<br>**Blue**<br>**96.04.0**<br>**Black**<br>56.34<br>096.71<br>|<br>~~ee~~|**96.04**<br>**Blue**<br>**96.04.0**<br>**Black**<br>56.34<br>096.71<br>|<br>~~ee~~|
|---|---|---|---|---|
|Plastic retaining and release clip<br>(supplied with socket -packagingcode SPA)|094.91.3<br>~~ee~~<br>~~1~~|094.91.30<br>—<br>~~ee~~<br>~~ee~~<br>~~1__,___~~|—<br>~~ee~~<br>~~ee~~<br>~~__,___~~|—<br>~~ee~~<br>~~ee~~<br>~~__,___~~|
|6-way jumper link|094.06<br>~~ee~~<br>~~1~~|094.06.0<br>—<br>~~ee~~<br>~~ee ~~<br>~~1__,___~~|—<br>~~ee~~<br> ~~ee~~<br>~~__,___~~|—<br>~~ee~~<br>~~ee~~<br>~~__,___~~|
|Identification tag|095.00.4<br>090.00.2<br>~~1__,___~~||090.00.2<br>~~__,___~~||
|Timer modules<br>**Technical data**<br>Rated values|86.30<br>86.00, 86.30<br>12 A - 250 V<br>~~1~~ ~~__,___~~||||
|Dielectric strength|2 kV AC||||
|Protection category|IP 20||||
|Ambient temperature<br>°C|–40…+70||||
|Screw torque<br>Nm <br>Ss)|0.8||||
|Wire striplength<br>mm <br>~~|~~|8<br>~~|~~||||
|Max. wire size for 96.02/04 sockets<br>mm2 <br>AWG <br>~~|~~<br>~~|~~|solid wire<br>stranded wire<br>~~|~~||stranded wire||
||1 x 6 / 2 x 2.5<br>1 x 4 / 2 x 2.5<br>~~|Fs~~<br>~~|~~<br>r~~rrrc—~~idzY||1 x 4 / 2 x 2.5||
||1 x 10 / 2 x 14<br>1 x 12 / 2 x 14<br>~~Fs~~<br>~~|~~<br>r~~rrrc—~~idzY||1 x 12 / 2 x 14||
**H**
**==> picture [485 x 99] intentionally omitted <==**
**----- Start of picture text -----**<br>
96.02 96.02 + 56.32 + 094.91.3 + 86.30 96.04 96.04 + 56.34 + 096.71 + 86.00<br>6-way jumper link for 96.02 socket 094.06 (blue) 094.06.0 (black)<br>Rated values 10 A - 250 V<br>—<br>094.06 we<br>P E A<br>P A T E N T<br>RO N<br>U<br>E E<br>U<br>NA E POR<br>**----- End of picture text -----**<br>
**10**
**86 SERIES**
|**97.P2**<br>Approvals<br>(according to type):<br>**097.01**<br>**060.48**<br>**Push-in terminal socket**panel or 35 mm rail (EN 60715) mount<br>**97.P1**<br>**97.P2**<br>For relay type<br>46.61<br>46.52<br>**Accessories**<br>Plastic retaining and release clip<br>(supplied with socket-packaging code SPA)<br>097.01<br>Metal retainingclip<br>097.71<br>Identification tag<br>095.00.4<br>8-way jumper link<br>097.58<br>2-way jumper link<br>097.52<br>2-way jumper link<br>097.42<br>Marker tagholder<br>097.00<br>Timer modules(see table below)<br>86.30<br>Sheet of marker tags for marker tag holder 097.00, 48 tags,<br>6 x 12 mm, for CEMBRE thermal transfer printers<br>060.48<br>**Technical data**<br>Rated values<br>16 A-250 V AC<br>8 A-250 V AC<br>Dielectric strength<br>6 kV(1.2/50μs)between coil and contacts<br>Protection category<br>IP 20<br>Ambient temperature<br>°C –40…+70(see diagram L97)<br>Wire striplength<br>mm 8<br>Min. wire size for 97.P1 and 97.P2 socket<br>solid wire<br>stranded wire<br>mm2 0.5<br>0.5<br>AWG 21<br>21<br>Max. wire size for 97.P1 and 97.P2 socket<br>solid wire<br>stranded wire<br>mm2 2 x 1.5 / 1 x 2.5<br>2 x 1.5 / 1 x 2.5<br>AWG 2 x 18 / 1 x 14<br>2 x 18 / 1 x 14<br>**L 97 - Rated current v ambient temperature**<br>97.P1<br>97.P2<br>Rated current (A)<br>**097.58**<br>**8-way jumper link**for 97.P1 and 97.P2 sockets<br>097.58<br>Rated values<br>10 A - 250 V<br>**097.52**<br>**2-way jumper link**for 97.P1 and 97.P2 sockets<br>097.52<br>Rated values<br>10 A - 250 V<br>**097.42**<br>**2-way jumper link**for 97.P1 and 97.P2 sockets<br>097.42<br>Rated values<br>10 A - 250 V<br>**097.00**<br>**Marker tag holder**for 95.P3 and 95.P5 sockets<br>097.00<br>CE @ FAL @<br>®<br>cAL ys<br>15~~.~~8<br>15~~.~~8<br>3~~.~~6<br>H<br>42~~.~~4<br>les |<br>"|<br>20<br>i<br>—__E,<br>| ft tt<br>|<br>| ff<br>No<br>Exh | Lik]so<br>aDS<br>-<br>'<br>b<br>~~SESE EEE~~<br>tag”<br>~~e~~e<br>tg<br>LEA<br>Pal<br>b<br>sL_i<br>tt<br>|<br>ti tt tt tt<br>.<br>.<br>a<br>SEEEEEEEERRE| ~~e~~e=<br>~~G~~k<br>we~ ~~E~~e<br>a<br>~~-~~20<br>0<br>20<br>40<br>60<br>80<br>(°C)<br>3~~LL~~<br>~~y~~<br>117.2<br>5.6<br>ff<br>~~a;ee~~<br>~~Hi~~<br>7~~7~~<br>><br>~~15.6~~<br>~~44~~<br>~~7~~|**97.P1**<br>**97.P2**<br>46.61<br>46.52<br>097.01|**97.P1**<br>**97.P2**<br>46.61<br>46.52<br>097.01|
|---|---|---|
||097.71||
||095.00.4||
||097.58||
||097.52||
||097.42||
||097.00||
||097.00<br>86.30||
||060.48<br>16 A-250 V AC<br>8 A-250 V AC||
||6 kV(1.2/50μs)between coil and contacts||
||IP 20||
||–40…+70(see diagram L97)||
||8||
||solid wire|stranded wire|
||0.5|0.5|
||21|21|
||solid wire|stranded wire|
||2 x 1.5 / 1 x 2.5|2 x 1.5 / 1 x 2.5|
**H**
**11**
**==> picture [24 x 24] intentionally omitted <==**
**----- Start of picture text -----**<br>
86<br>SERIES<br>**----- End of picture text -----**<br>
|**Screw terminal socket**<br>panel or 35 mm rail (EN 60715) mount<br>For relay type<br>**Accessories**<br>Plastic retain and eject clip<br>(supplied with socket -packagingcode SPA)|**97.01**<br>**Blue**<br>**97.02**<br>**Blue**<br>46.61<br>46.52<br>097.01|**97.01**<br>**Blue**<br>**97.02**<br>**Blue**<br>46.61<br>46.52<br>097.01|
|---|---|---|
|8-way jumper link|095.18(blue)|095.18.0(black)|
|Identification tag|095.00.4||
|Timer modules<br>**Technical data**<br>Rated current|86.30<br>16 A - 250 V AC<br>8 A - 250 V AC||
|Dielectric strength|6 kV(1.2/50µs)between coil and contacts||
|Protection category|IP 20||
|Ambient temperature|°C –40…+70(see diagram L97)||
|Screw torque<br>Nm|Nm 0.8||
|Wire striplength<br>mm|mm 8||
|Max. wire size for 97.01 and 97.02 sockets<br>mm<br>AWG|solid wire<br>mm2<br>1 x 6 / 2 x 2.5|stranded wire|
|||1 x 4 / 2 x 2.5|
||AWG<br>1 x 10 / 2 x 14|1 x 12 / 2 x 14|
## **L 97 - Rated current v ambient temperature**
(for 46.61 relay / 97.01 socket combination)
**==> picture [7 x 51] intentionally omitted <==**
**----- Start of picture text -----**<br>
Rated current (A)<br>**----- End of picture text -----**<br>
**H** "
**==> picture [491 x 164] intentionally omitted <==**
**----- Start of picture text -----**<br>
97.01 COIL ’ 97.01 fete) 1 9 7.02 col 4 ee) 97.02 1 iY |<br>97.02 + 46.52 + 097.01<br>-20 0 20 40 60 °° L t x ! t > : + 86.30 P S<br>8-way jumper link for 97.01 and 97.02 sockets 095.18 (blue) 095.18.0 (black)<br>Rated values 10 A - 250 V<br>aS ZB 8 110.5 5.1<br>095.18<br>P E A<br>P A T E N T<br>RO N<br>U<br>E E<br>U<br>NA E POR<br>**----- End of picture text -----**<br>
**12**
Updated at April 29, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →