Image not available
Illustrative purposes only
85103035
SAFETY
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CROUZET / PARTNER STOCK
- Product type: Safety Relays
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 680.55 € |
| Current stock | 10+ |
| Lead time | 30 days |
02/11/2015 www.crouzet.com ## **Emergency stop and safety guard monitoring 1 channel KNAC3-YS Part number 85103035** "Emergency stop" & "Gate monitoring" functions Single channel operation Security with redundancy and feedback circuit 3 "NO" security contacts 1 "NC" monitoring contact Security category 3 (according to EN 954-1) Performance Level (PL) d, safety category 3 to EN ISO 13849-1 SIL Claimed Level (SIL CL) 2 to IEC/EN 62061 Terminals : fixed screw terminals or plugin cage clamp terminals |**Part numbers**<br>~~SS~~|**Part numbers**<br>~~SS~~|**Part numbers**<br>~~SS~~|**Part numbers**<br>~~SS~~|**Part numbers**<br>~~SS~~| |---|---|---|---|---| |**Type**<br>**Terminals**<br>**Voltages**<br>**Supply frequency range (Hz)**<br>**Outputs**<br>**85103035**<br>KNAC3-YS<br>Clamps<br>230 VAC<br>50/60<br>3 NO + 1 NC<br>SS~~(a~~||||| |**Specifications**<br>~~SS~~||||| |**Operating characteristics**||||| |Functions||Emergency stop||| |||Monitoring of safety gates||| |Operation<br>Control input<br>ee<br>rrrrrrrr———s||1 channel<br>Manual restart with On-button (Y1 - Y2 terminals)||| |||Automatic restart (Y1 - Y2 linked)||| |Failure detection<br>res||Between terminal Y1 and common||| |Display of output state by LED||Power supply : PWR||| |||Outputs : OUT (relays K1 & K2)||| |**Supply**||||| |Supply voltage||85 102 031 / 85 103 031 : 24 VDC||| |||85 102 034 / 85 103 034 : 110 VAC||| |||85 102 035 / 85 103 035 : 230 VAC||| |Supply frequency range (Hz)<br>~~a~~||50 / 60 for AC versions||| |Operating range||AC : -15 % / +10 % U||| |||DC :±10 % U (at 10 % residual ripple)||| |||DC :- 15 % / +10 % U (at 48 % residual ripple)||| |Consumption||1,5 W (24 VDC)||| |||3,5 VA (230 VAC)||| |Initialization time<br>~~ee~~||0,5 s||| |**Precision**||||| |Maximum reset time||40 ms (24 VDC)||| |||200 ms (230 VAC)||| |Maximum response time on emergency stop||70 ms (24 VDC)||| |||35 ms (230 VAC)||| |**Output specification**||||| |Type<br>~~ee~~||Forcibly guided relays (positively driven)|Forcibly guided relays (positively driven)|Forcibly guided relays (positively driven)| |Number of safety circuits<br>~~a~~||3 NO||| |Number of data circuits<br>Nominal output voltage<br>Max. thermal current I for each contact<br>~~a~~<br>ee<br>reese<br>ee<br>reese||1 NF<br>250 VAC max.<br>5 A||| |Maximum power rating||According to AC15 (NO contacts) : 3 A / 230 V AC||| |||According to AC15 (NC contacts) : 2 A / 230 VAC||| |||According to DC13 (NO contacts) : 4 A / 24 VDC ; 0,5 A / 110 VDC||| |||According to DC13 (NC contacts) : 4 A / 24 VDC||According to DC13 (NC contacts) : 4 A / 24 VDC| |Electrical endurance||At 5 A, 230 VAC, cosφ=1 : 1,5 x 10|1 : 1,5 x 105switching cycles|| |Mechanical life<br>Maximum rate<br>TT<br>TTTTOTOCOCOC™OC*‘*S<br>rrr||At 8 A, 24 VDC, according to DC 13 (NO contacts) : 25 x 10<br>20 x 106switching cycles<br>600 switching cycles / h|At 8 A, 24 VDC, according to DC 13 (NO contacts) : 25 x 103(ON : 0,4 s ; OFF : 9,6 s)|| |Protection against short circuits||Max. fuse rating : 10 A gL||| |||Line circuit breaker : B 6 A||| |**Climatic environment**||||| |Operating temperature (oC)<br>Storage temperature (0C)<br>Altitude<br>~~a~~<br>TT<br>TTTTTOCO™O.C*SW<br>errs||-15 →+55 °C<br>-25 →+85 °C<br>< 2000m||| |Climate resistance according to IEC/EN 60068-1<br>~~ee~~||15 / 055 / 04||| |**Mechanical environment**||||| Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 www.crouzet.com Vibration resistance according to IEC/EN 60068-2-6 Amplitude : 0,35 mm Lo Frequency : 10 →55 Hz **Electromagnetic environment** Immunity to electrostatic discharges acc. IEC/EN 61000-4- ~~Po~~ 2 8 kV (air) Immunity to radiated, radio-frequency, electromagnetic 10 V / m Po field acc. IEC/EN 61000-4-3 Immunity to rapid transient bursts acc. to IEC/EN 61000-42 kV Lo 4 Immunity to shock waves according to IEC/EN 61000-4-5 Between wires for power supply : 1 kV Lo Between wires and ground : 2 kV Immunity to radio frequency in common mode acc. to 10 V Po IEC/EN 61000-4-6 ~~ee~~ Interference suppression according to IEC/EN 55011 Limit value class B **Housing** ~~ee~~ Material : self-extinguishing (UL94VO) Thermoplastic with V0 extinction behaviour ~~ee~~ Protection (IEC/EN 60529) - Casing IP40 ~~pO~~ Protection (IEC/EN 60529) - Term. block IP20 ~~po~~ Mounting DIN-rail Weight (g) 200 (24 VDC) ~~Lo~~ 270 (230 VAC) **Safety standards** ~~pe~~ Approvals CE, TÜV, cULus ~~pe~~ Environmental directive 2002/95/CE RoHS ~~pe~~ Environmental regulation 1907/2006 Reach Security data according to EN ISO 13849-1 Performance Level (PL) : d ~~Po~~ Category : 3 ~~pe~~ SIL Claimed Level (SIL CL) to IEC/EN 62061 2 ~~pe~~ Safety Integrity Level (SIL) according to CEI/EN 61508 2 ~~ee~~ Safety category to EN 954-1 3 ~~ee~~ **Principles** Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 www.crouzet.com ## ~~ee~~ **Dimensions (mm) KNAC3-YS - Clamp terminals** ~~ee~~ **Curves Function diagram** Pushbutton (On) stop (Ot) K1 Relay K2 Relay ~~ee~~ **Connections Front face drawing KNAC3-YS** Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 www.crouzet.com ~~ee~~ **Connections Contacts** A1 (+) : + / L A2 : - / N Y1, Y2 : Validation Input Y21 (-) : Measure Output (-) of secondary used for example in IT networks for insulation control 13, 14, 23, 24, 33, 34 : Safety circuit outputs (forcibly guided NO contacts) 41, 42 : Monitoring output (forcibly guided NC contact) ~~ee~~ **Applications Single channel emergency-stop circuit without feed back loop, with or without automatic restart** Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 www.crouzet.com For automatic restart, terminals Y1 - Y2 must be linked. No ON-pushbutton necessary ~~ee~~ **Applications Contact reinforcement by external contactors** For currents > 5 A, the output contacts can be reinforced by external contactors. Functioning of the external contactors is monitored by looping the NC contacts into the start circuit (Y1-Y2) Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected
Updated at April 23, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →