85.02.0.024.0000
Analogue Timer, Miniature Plug In, 85 Series, Multifunction, 7 Ranges, 0.05 s, 100 h
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: FINDER
- Product type: Analogue Timers
- Product Range:85 Series; Timer Functions:Multifunction; No. of Timing Ranges:7Ranges; Time Min:0.05s; Time Max:100h; Timer Output:2 Changeover Relays; Supply Voltage Max:24V; Current Rat
- SVHC: No SVHC (04-Feb-2026)
- Time Max: 100h
- Time Min: 0.05s
- Timer Output: 2 Changeover Relays
- Product Range: 85 Series
- Timer Functions: Multifunction
- Current Rating Nom: 50mA
- Panel Cutout Width: 20.6mm
- Supply Voltage Max: 24V
- Panel Cutout Height: 20.6mm
- No. of Timing Ranges: 7Ranges
- Connection / Termination: Plug-In
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 43.53 € |
| Current stock | 10+ |
| Lead time | 30 days |
**85 SERIES** **H** ## **Plug-in timer** **==> picture [25 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 85.02<br>**----- End of picture text -----**<br> **==> picture [26 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 85.03<br>**----- End of picture text -----**<br> **==> picture [26 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> 85.04<br>**----- End of picture text -----**<br> **85.02 - 2 Pole 10 A** **85.03 - 3 Pole 10 A** **85.04 - 4 Pole 7 A** • Multifunctions - Seven time scales, from 0.05 s to 100 h - 94 series sockets for 35 mm rail (EN 60715) mount with push-in and screw terminal - 2 pole, 10 A - AC/DC supply non polarized - Plug-in for use with 94 series sockets **AI:** On-delay **DI:** Interval **SW:** Symmetrical flasher (starting pulse on) **GI:** Pulse delayed - 3 pole, 10 A - 4 pole, 7 A - AC/DC supply non polarized - AC/DC supply non polarized - Plug-in for use with 94 series sockets - Plug-in for use with 94 series sockets **AI:** On-delay **AI:** On-delay **DI:** Interval **DI:** Interval **SW:** Symmetrical flasher **SW:** Symmetrical flasher (starting pulse on) (starting pulse on) **GI:** Pulse delayed **GI:** Pulse delayed **GI:** Pulse delayed ||_For ULratings see:_||Wiring diagram||Wiring diagram|Wiring diagram| |---|---|---|---|---|---|---| ||_“General technical information” page_V||(without control signal)|(without control signal)||(without control signal)| ||**Contact specification**<br>Contact configuration||2 CO (DPDT)||3 CO (3PDT)|4 CO (4PDT)| ||Rated current/Maximum peak current<br>A||10/20||10/20|7/15| ||Rated voltage/<br>Maximum switchingvoltage|V AC|250/400||250/400|250/250| ||Rated load AC1|VA|2500||2500|1750| ||Rated load AC15 (230 V AC)|VA|500||500|350| ||Single phase motor rating (230 V AC)<br>kW||0.37||0.37|0.125| ||Breaking capacity DC1: 30/110/220 V<br>A||10/0.25/0.12||10/0.25/0.12|7/0.25/0.12| ||Minimum switching load|mW (V/mA)|300 (5/5)||300 (5/5)|300 (5/5)| ||Standard contact material<br>**Supply specification**<br>Nominal voltage (UN)|V AC (50/60 Hz)|AgNi<br>230…240||AgNi<br>230…240|AgNi<br>230…240| |||V AC/DC|12 - 24 - 48 - 110…125 (non polarized)||12 - 24 - 48 - 110…125 (non polarized)|| ||Rated power AC/DC|VA (50 Hz)/W|2/2||2/2|2/2| ||Operating range|AC|(0.85…1.1)UN||(0.85…1.1)UN|(0.85…1.1)UN| ||**Technical data**|DC|(0.85…1.1)UN||(0.85…1.1)UN|(0.85…1.1)UN| ||Specified time range||(0.05…1)s, (0.5…10)s, (5…100)s, (0.5…10)min, (5…100)min, (0.5…10)h, (5…100)h|||| ||Repeatability|%|± 2||± 2|± 2| ||Recovery time|ms|≤ 20||≤ 20|≤ 20| ||Minimum control impulse|ms|—||—|—| |III-2016, www.findernet.com|Setting accuracy-full range<br>Electrical life at rated load in AC1<br>Ambient temperature range<br>Protection category<br>**Approvals**(according to type)|%<br>cycles<br>°C|± 5<br>200 · 103<br>–20…+60<br>IP 40<br>CE @||± 5<br>± 5<br>200 · 103<br>150 · 103<br>–20…+60<br>–20…+60<br>IP 40<br>IP 40<br>®<br>HAL<br>& Ais|| **1** **85 SERIES** ## **Ordering information** Example: 85 series timer, 4 CO (4PDT), 24 V AC/DC supply voltage, AI, DI, GI, SW functions. **8 5 . 0 4 . 0 . 0 2 4 . 0 0 0 0** ## **Series** ## **Type** 0 = Multifunction (AI, DI, GI, SW)* - AI = On-delay - DI = Interval - GI = Pulse delayed SW = Symmetrical flasher (starting pulse on) ## **No. of poles** ## **Supply voltage** 012 = 12 V AC/DC 024 = 24 V AC/DC 048 = 48 V AC/DC 125 = (110…125)V AC/DC 240 = (230…240)V AC ## **Supply version** 0 = AC (50/60 Hz)/DC 8 = AC (50/60 Hz) for 240 V only 2 = 2 pole - 10 A 3 = 3 pole - 10 A 4 = 4 pole - 7 A ## **Technical data** ## **Insulation** ||Dielectric strength|between input and output circuit<br>V AC|**85.02, 85.03**|**85.02, 85.03**|**85.04**|**85.04**| |---|---|---|---|---|---|---| ||||2000||2000|| |||between open contacts<br>V AC|1000||1000|| |||between adjacent contacts<br>V AC|2000||1550|| ||Insulation (1.2/50 µs) between input and output<br>kV||6||4|| ||**EMC specifications**|||||| ||**Type of test**||**Reference standard**|||| ||Electrostatic discharge|contact discharge|EN 61000-4-2||n.a.|| |||air discharge|EN 61000-4-2||8 kV|| ||Radio-frequencyelectromagnetic field(80 ÷ 1000 MHz)||EN 61000-4-3||15 V/m|| |**H**||||||| ||Fast transients(burst) (5-50 ns,5 kHz)on Supplyterminals||EN 61000-4-4||4 kV|| ||Surges (1.2/50 µs) on<br>Supplyterminals|common mode|EN 61000-4-5||4 kV|| |||differential mode|EN 61000-4-5||2 kV|| ||Radio-frequencycommon mode(0.15 ÷ 80 MHz)on Supplyterminals||EN 61000-4-6||10 V|| ||Power-frequency (50 Hz)||EN 61000-4-8||30 A/m|| ||Radiated and conducted emission||EN 55022||class B|| ||**Other data**|||||| ||Power lost to the environment|without contact current<br>W|1.6|||| |||with rated current<br>W|3.7(85.02)|4.7(85.03)||3.6(85.04)| ## **Times scales** **==> picture [407 x 41] intentionally omitted <==** NOTE: time scales and functions must be set before energising the timer. **2** **85 SERIES** ## **Functions** |**U**|=|Supply| |---|---|---| |||voltage| ||=|Output| |||contact| ||LED<br>Sup<br>volt|ply<br>age<br>NO(SPDT-NO)<br>output contact|Contacts<br>Open<br>Closed|Contacts<br>Open<br>Closed| |---|---|---|---|---| ||O|FF<br>Open|x1 - x4|x1 - x2| ||O|N<br>Open|x1 - x4|x1 - x2| ||O|N<br>Open<br>(Timingin Progress)|x1 - x4|x1 - x2| ||O|N<br>Closed|x1 - x2|x1 - x4| **Wiring diagram Type: 85.02, 85.03, 85.04** **==> picture [56 x 61] intentionally omitted <==** **==> picture [204 x 33] intentionally omitted <==** ## **(AI) On-delay.** Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. **==> picture [512 x 496] intentionally omitted <==** **----- Start of picture text -----**<br> (DI) Interval.<br>85.02<br>Apply power to timer.<br>Output contacts transfer immediately.<br>After the preset time has elapsed, contacts reset.<br>(GI) Pulse delayed.<br>Apply power to timer. Output contacts transfer after<br>preset time has elapsed. Reset occurs after a fixed time<br>of 0.5 s.<br>85.03<br>(SW) Symmetrical flasher (starting pulse on).<br>Apply power to timer.<br>Output contacts transfer immediately and cycle<br>between ON and OFF for as long as power is applied.<br>The ratio is 1:1 (time on = time off).<br>85.04<br>U = Supply voltage<br>Signal ON Pulse<br>S = Signal switch<br>On mometary closure of Signal Switch (S) > 50 ms,<br>Uc = Supply voltage the output contacts transfer and remain so (with self-<br>to the timer holding on contact 11-14) for the duration of the preset<br>delay, after which they reset.<br>11-14 = Self-holding<br>contact<br> = Output contact<br>**----- End of picture text -----**<br> **H** **3** **85 SERIES** **94.P4** Approvals (according to type): ## **060.72** ee **060.48** **==> picture [403 x 296] intentionally omitted <==** **----- Start of picture text -----**<br> |||||| |---|---|---|---|---| |Push-in terminal socket|panel or 35 mm|94.P3|94.P4| |(EN 60715) rail mount|Blue|Blue| |For timer type|85.03|85.02, 85.04| |Accessories| |Metal retaining clip|094.81| |6-way|jumper link|094.56| |Identification tag|094.00.4| |2-way|jumper link|094.52| |2-way|jumper link|097.52| |Marker tag holder|097.00| |Sheet of marker tags for marker tag holder 097.00 , 48 tags,| |6 x 12 mm for CEMBRE's thermal transfer printers|060.48| |Sheet of marker tags for marker tag holder 097.00, 72 tags,| |6 x 12 mm|060.72| |Technical data| |Rated values|10 A - 250 V| |Dielectric strength|2 kV AC| |Protection category|IP 20| |Ambient temperature|°C|–40…+70| |Wire strip length|mm|8| |Min. wire size for 94.P3 and 94.P4 sockets|solid wire|stranded wire| |mm|[2]|Po|0.5|0.5| |AWG|PO|21|21| |Max. wire size for 94.P3 and 94.P4 sockets|solid wire|stranded wire| |mm|[2]|2 x 1.5 / 1 x 2.5|2 x 1.5 / 1 x 2.5| |AWG|2 x 18 / 1 x 14|2 x 18 / 1 x 14| **----- End of picture text -----**<br> **H** ZF **094.56** 94.P3 94.P4 **6-way jumper link** for 94.P3 and 94.P4 sockets 094.56 (blue) Rated values 10 A - 250 V ~~ee~~ **2-way jumper link** for 94.P3 and 94.P4 sockets 094.52 Rated values 10 A - 250 V **094.52** **2-way jumper link** for 94.P3 and 94.P4 sockets 097.52 Rated values 10 A - 250 V **097.52** **Marker tag holder** for 94.P3 and 94.P4 sockets 097.00 **097.00** **4** **85 SERIES** **H** |**Screw terminal (Box clamp) socket**panel or 35 mm<br>(EN 60715) rail mount<br>**94.02**<br>**Blue**<br>For timer type<br>85.02<br>**Accessories**<br>Metal retainingclip|**94.02.0**<br>**Black**<br>**94.03**<br>**Blue**<br>**94.03.0**<br>**Black**<br>**94.04**<br>**Blue**<br>**94.04.0**<br>**Black**<br>85.03<br>85.04<br>094.81|**94.02.0**<br>**Black**<br>**94.03**<br>**Blue**<br>**94.03.0**<br>**Black**<br>**94.04**<br>**Blue**<br>**94.04.0**<br>**Black**<br>85.03<br>85.04<br>094.81|**94.02.0**<br>**Black**<br>**94.03**<br>**Blue**<br>**94.03.0**<br>**Black**<br>**94.04**<br>**Blue**<br>**94.04.0**<br>**Black**<br>85.03<br>85.04<br>094.81| |---|---|---|---| |6-way jumper link<br>094.06|094.06.0 094.06<br>094.06.0|094.06|094.06.0| |Identification tag|094.00.4||| |Marker tagholder|097.00||| |Sheet of marker tags marker tag holder 097.00 , 48 tags,<br>6 x 12 mm for CEMBRE's thermal transferprinters|060.48||| |Sheet of marker tags for marker tag holder 097.00, 72 tags,<br>6 x 12 mm<br>**Technical data**<br>Rated values<br>10 A - 250 V|060.72<br>10 A - 250 V||| |Dielectric strength<br>2 kV AC|||| |Protection category<br>IP 20|||| |Ambient temperature<br>°C –40…+70|–40…+70||| |Screw torque<br>Nm 0.5|||| |Wire striplength<br>mm 8|||| |Max. wire size for 94.02/03/04 sockets<br>solid wire<br>mm2 1 x 6 / 2 x 2.5<br>AWG 1 x 10 / 2 x 14<br>~~po~~<br>~~Po~~|solid wire<br>stranded wire<br>~~po~~||| ||1 x 6 / 2 x 2.5<br>1 x 4 / 2 x 2.5<br>~~po~~<br>~~Po~~||| ||1 x 10 / 2 x 14<br>1 x 12 / 2 x 14<br>~~Po~~||| **==> picture [484 x 62] intentionally omitted <==** **----- Start of picture text -----**<br> 6-way jumper link for 94.02, 94.03 and 94.04 sockets 094.06 (blue) 094.06.0 (black)<br>Rated values 10 A - 250 V<br>ZF 3 24 } 8p<br>eras<br>094.06 0.75 otg p26.3 27 27 27 26.3<br>P E<br>P A T E N T<br>RO AN<br>U<br>E<br>E<br>U<br>NA E POR<br>**----- End of picture text -----**<br> **5** **85 SERIES** **==> picture [497 x 434] intentionally omitted <==** **----- Start of picture text -----**<br> Screw terminal (Box clamp) socket panel or 35 mm 94.84.2 94.84.20<br>(EN 60715) rail mount Blue Black<br>For timer type 85.02, 85.04<br>Accessories<br>Metal retaining clip<br>(supplied with socket - packaging code SMA) 094.81<br>94.84.2<br>6-way jumper link 094.06 094.06.0<br>Approvals a Identification tag | 094.80.3<br>(according to type): Technical data<br>CE FAL & AXus Rated values 10 A - 250 V<br>Dielectric strength 2 kV AC<br>Protection category IP 20<br>Ambient temperature °C –40…+70<br>© Screw torque Nm 0.5<br>Wire strip length mm 7<br>Max. wire size for 94.84.2 socket Po solid wire stranded wire<br>mm [2] Po 1 x 6 / 2 x 2.5 1 x 4 / 2 x 2.5<br>AWG 1 x 10 / 2 x 14 1 x 12 / 2 x 14<br>|<br>Top terminals 7 42.3<br>a f l J )<br>Pe > ee (Ca [Ts<br>H o oll r a<br>~ 8<br>31] 21 cn a"<br>94.84.2 Bottom terminals 94.84.2<br>6-way jumper link for 94.84.2 socket 094.06 (blue) 094.06.0 (black)<br>Rated values 10 A - 250 V<br>H<br>094.06<br>P E<br>P A T E N T<br>RO AN<br>U<br>E<br>E<br>U<br>NA E POR<br>**----- End of picture text -----**<br> **6** **85 SERIES** **H** **==> picture [66 x 31] intentionally omitted <==** **----- Start of picture text -----**<br> 94.94.3<br>Approvals<br>(according to type):<br>**----- End of picture text -----**<br> |**Screw terminal (Box clamp) socket**panel or 35 mm<br>rail mount|**Screw terminal (Box clamp) socket**panel or 35 mm<br>rail mount||**94.92.3**<br>**(blue)**|**94.92.30**<br>**(black)**|**94.94.3**<br>**(blue)**|**94.94.30**<br>**(black)**| |---|---|---|---|---|---|---| |For timer type|||85.02||85.04|| |**Accessories**<br>Metal retainingclip||||094.81||| |6-way jumper link|||094.06|094.06.0|094.06|094.06.0| |Identification tag<br>**Technical data**||||094.80.3||| |Rated values|||10 A - 250 V|||| |Dielectric strength<br>Protection category|||2 kV AC<br>IP 20|||| |Ambient temperature||°C|–25…+70|||| ||Screw torque|Nm|0.5|||| |Wire striplength||mm|8|||| |Max. wire size for 94.92.3 and 94.94.3 sockets|||solid wire||stranded wire|| |||mm2|1 x 6 / 2 x 2.5||1 x 4 / 2 x 2.5|| |||AWG|1 x 10 / 2 x 14||1 x 12 / 2 x 14|| **==> picture [89 x 122] intentionally omitted <==** **----- Start of picture text -----**<br> Top terminals +<br>| ecco<br>q<br>|<br>Bottom terminals<br>94.94.3<br>**----- End of picture text -----**<br> **==> picture [81 x 58] intentionally omitted <==** **----- Start of picture text -----**<br> 094.06<br>P E<br>P A T E N T<br>RO AN<br>U<br>E<br>E<br>U<br>NA E POR<br>**----- End of picture text -----**<br> **6-way jumper link** for 94.92.3 and 94.94.3 sockets Rated values 094.06 (blue) 094.06.0 (black) 10 A - 250 V **7** **85 SERIES** |(according to type):<br>(according to type):<br>**Screw terminal (Plate clamp) socket**<br>panel or 35 mm rail (EN 60715) mount<br>**94.72**<br>**Blue**<br>**94.72.0**<br>**Black**<br>For timer type<br>85.02<br>**Accessories**<br>Metal retaining clip (supplied with timer)<br>**Screw terminal socket**<br>panel or 35 mm rail (EN 60715) mount<br>**94.82**<br>**Blue**<br>For timer type<br>85.02<br>**Accessories**<br>Metal retaining clip (supplied with timer)<br>**Technical data**<br>Rated values<br>10 A - 250 V<br>Dielectric strength<br>2 kV AC<br>Protection category<br>IP 20<br>Ambient temperature<br>°C –40…+70<br>Screw torque<br>Nm 0.5<br>Wire striplength<br>mm 8(94.72,94.73<br>Max. wire size for 94.72, 94.73, 94.74 and 94.82 sockets<br>solid wire<br>mm2 1 x 2.5 / 2 x 1.5<br>AWG 1 x 14 / 2 x 16<br>Hl<br>S ®@<br>®<br>& Aus<br>=,<br>@<br>@<br>FAL&<br>~~J~~<br>°<br>~~|~~<br>clus|**94.72.0**<br>**Black**<br>**94.73**<br>**Blue**<br>**94.73.0**<br>**Black**<br>**94.74**<br>**Blue**<br>**94.74.0**<br>**Black**<br>85.03<br>85.02, 85.04<br>094.81<br>**94.82.0**<br>**Black**<br>85.02<br>094.81| |---|---| ||| ||| ||| ||| ||94.73,94.74)<br>9(94.82)| ||stranded wire| ||1 x 2.5 / 2 x 1.5<br>1 x 2.5 / 2 x 1.5| ||1 x 14 / 2 x 16<br>1 x 14 / 2 x 16| **==> picture [11 x 10] intentionally omitted <==** **----- Start of picture text -----**<br> H<br>**----- End of picture text -----**<br> **==> picture [357 x 131] intentionally omitted <==** **----- Start of picture text -----**<br> 94.72 94.73 94.74<br>«2 25.<br>Ne . r_<br>FI] no | 242 “U<br>[A [E}}comCOIL (e_S | |e oa“ Le Y<br>94.82 .26<br>94.82<br>**----- End of picture text -----**<br> **8**
Updated at April 29, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →