Image not available
Illustrative purposes only
84140000
SOLID STATE RELAYS
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SENSATA/CRYDOM
- Product type:
- SVHC: No SVHC (25-Jun-2025)
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 95.79 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **DUAL GN SERIES** ## PANEL MOUNT ## Features - Current rating 25 and 40 Amps - Output voltage 24-280 VAC and 48-660 VAC - Direct bond copper substrate - Back to back dual SCR output - 4000 VAC optical isolation - Zero Voltage and Instantaneous Turn-On - UL/cUL Recognized, CE Compliant ## **SPECIFICATIONS** ## Product Selection |**1/4” Quick Connect 280 VAC**<br>**Control Voltage**<br>**25 A**<br>**40 A**|**1/4” Quick Connect 280 VAC**<br>**Control Voltage**<br>**25 A**<br>**40 A**|**1/4” Quick Connect 280 VAC**<br>**Control Voltage**<br>**25 A**<br>**40 A**|**1/4” Quick Connect 660 VAC**|**1/4” Quick Connect 660 VAC**|**Locking Connector 280 VAC**|**Locking Connector 280 VAC**| |---|---|---|---|---|---|---| ||**25 A**|**40 A**|**25 A**|**40 A**|**25 A**|**40 A**| |**4-15 VDC**|84140000|84140200|84140500|84140600|84140800|84140900| |**17-32 VDC**|84140410|84134210|84140510|84140610|84140810|84140910| ## Output Specifications[(1)] |**Description**|**280 VAC**|**660 VAC**| |---|---|---| |**Operating Voltage [Vrms]**|24-280|48-600| |**Transient Voltage(t=1 min.) [Vpk]**|550|1000| |**Maximum Off-State Leakage Current @ Rated Voltage**<br>**(@ max. line voltage) [mArms]**|0.1|0.25| Page 1 Copyright © 2018 Sensata Technologies, Inc. www.sensata.com ## Output Specifications[(1)] |**Description**|**25 A**|**40 A**| |---|---|---| |**Maximum Load Current [Arms]**|25|40| |**Minimum Load Current [mArms]**|100|100| |**Maximum 1 Cycle Surge Current (50/60Hz) [Apk]**|275/300|710/750| |**1 Second surge current (50/60 Hz @ Ta=25°C) [Apk]**|85|150| |**Maximum On-State Voltage Drop @ Rated Current [Vpk]**|1.4|1.3| |**Thermal Resistance Junction to Case (Rjc) [°C/W]**|0.6|0.4| |**Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec]**|380/370|2520/2320| |**Maximum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]**|500|500| ## Input Specifications[(1)] |**Description**|**84140x0x**|**84140x1x**| |---|---|---| |**Control Voltage Range [Vdc]**|4-15|17-32| |**Minimum Turn-On Voltage [Vdc]**|4|17| |**Must Turn-Off Voltage [Vdc]**|1|1| |**Minimum Input Current (for on-state) [mA]**|7.5|13| |**Maximum Input Current [mA]**|34|24| |**Nominal Input Impedance [Ohms]**|500|1500| |**Maximum Turn-On Time [msec](2)**|1/2 Cycle|| |**Maximum Turn-Off Time [msec]**|1/2 Cycle|| ## General Specifications[(1)] |**Description**|**Parameters**| |---|---| |**Ambient Operating Temperature Range**|-40 to 80°C| |**Ambient Storage Temperature Range**|-40 to 100 °C| |**Input to Output Isolation**|4000 Vrms| |**Input/Output to Ground Isolation**|2500 Vrms| |**Input to Output Capacitance**|8 pF| |**Operation Frequency**|47 to 63 Hz| |**Housing Material**|UL94 V-0 (self extinguishing)| |**Weight (typical)**|3.2 oz (91.5g)| ## **MECHANICAL SPECIFICATIONS[(1)]** **==> picture [485 x 178] intentionally omitted <==** **----- Start of picture text -----**<br> Tolerance: ±0.02 in / 0.5 mm<br>All dimensions are in: inches [millimeters]<br>1.78<br>[45.3] Mounting<br>Hole/Slot<br>1.17 0.19 [4.9]<br>[29.7] DIA.<br>0.18<br>[4.7] 1.00<br>[25.4]<br>LI 0.56 E ac<br>[14.3]<br>p l i ^ fq ab ^ = vpo qb i 1.87 1.21 1.31<br>[47.5] [30.6] 0.86 [33.2]<br>Input A + - + -Input B [21.8] Mating Connector for 841408xxx and 841409xxx<br> Molex # 50-57-9404 without pins<br>! [15.2]0.60 —(AYN Tot _| ——|-———_— [58.4]2.30 _———_ + 1 | Crimp Pins Molex # 16-02-0103 ;<br>0.74<br>Pin .025 SQ<br>[18.8] .100 CENTERS<br>[Fr tL [11.5]0.45 (4 places)<br>**----- End of picture text -----**<br> Page 2 Copyright © 2018 Sensata Technologies, Inc. www.sensata.com ## **WIRING DIAGRAM** **==> picture [168 x 143] intentionally omitted <==** ## **EQUIVALENT CIRCUIT BLOCK DIAGRAMS** **==> picture [275 x 73] intentionally omitted <==** **==> picture [275 x 73] intentionally omitted <==** ## **THERMAL DERATE INFORMATION** **==> picture [211 x 143] intentionally omitted <==** **==> picture [213 x 143] intentionally omitted <==** Page 3 Copyright © 2018 Sensata Technologies, Inc. www.sensata.com Example : 84140010 ## **ORDERING OPTIONS** **==> picture [542 x 405] intentionally omitted <==** **----- Start of picture text -----**<br> 84140 0 1 0<br>Family<br>1/4” Quick Connect 280 VAC<br>1/4” Quick Connect 660 VAC<br>Locking Connector 280 VAC<br>Rated Load Current<br>1/4” Quick Connect 280 VAC<br>0 : 25 Amp/Zero Voltage Turn-On<br>1 : 25 Amp/Instantaneous Turn-On<br>2 : 40 Amp/Zero Voltage Turn-On<br>3 : 40 Amp/Instantaneous Turn-On<br>1/4” Quick Connect 660 VAC<br>5 : 25 Amp<br>6 : 40 Amp<br>Locking Connector 280 VAC<br>8 : 25 Amp<br>9 : 40 Amp<br>Control Voltage<br>1/4” Quick Connect 280 VAC<br>0 : 4-15 VDC<br>1 : 17-32 VDC<br>1/4” Quick Connect 660 VAC<br>0 : 4-15 VDC<br>1 : 17-32 VDC<br>Locking Connector 280 VAC<br>0 : 4-15 VDC<br>1 : 17-32 VDC<br>Operating Voltage<br>1/4” Quick Connect 280 VAC<br>0 : 24-280 VAC<br>1/4” Quick Connect 660 VAC<br>0 : 48-660 VAC/Zero Voltage Turn-On<br>1 : 48-660 VAC/Instantaneous Turn-On<br>Locking Connector 280 VAC<br>0 : 24-280 VAC/Zero Voltage Turn-On<br>1 : 24-280 VAC/Instantaneous Turn-On<br>**----- End of picture text -----**<br> ## **GENERAL NOTES** - (1) All parameters at 25°C unless otherwise specified. - (2) Turn-on time for Instantaneous turn-on versions is 0.02 msec. For additional information or specific questions, contact Crydom Technical Support. Page 4 Copyright © 2018 Sensata Technologies, Inc. www.sensata.com ## **AGENCY APPROVALS & CERTIFICATIONS** EN60950-1: Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: Certified according to EN 62314:2006 IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3 IEC 61000-4-5 Electrical Surges Level 3 ## **WARNINGS** RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE - The product’s side panels may be hot, allow the product to cool before touching - Follow proper mounting instructions including torque values - Do not allow liquids or foreign objects to enter this product **Failure to follow these instructions can result in serious injury, or equipment damage.** HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH - Disconnect all power before installing or working with this equipment - Verify all connections and replace all covers before turning on power **Failure to follow these instructions will result in death or serious injury.** Page 5 Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. ## **CONTACT US** ## **Americas** +1 (877) 502 5500 sales.crydom@sensata.com **Europe, Middle East & Africa** +44 (1202) 416170 ssr-info.eu@sensata.com **Asia Pacific** sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev:12/04/18 ECN 20395 FDE-07-01 Rev. B www.sensata.com Copyright © 2018 Sensata Technologies, Inc.
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →