- Manufacturer: CROUZET
- Product type:
- SVHC: Lead (21-Jan-2025)
- Load Current: 25A
- Product Range: GNA Series
- Relay Mounting: Panel Mount
- Switching Mode: Zero Crossing
- Relay Terminals: Screw
- Control Voltage Max: 32VDC
- Control Voltage Min: 4VDC
- Contact Configuration: -
- Operating Voltage Max: 280VAC
- Operating Voltage Min: 24VAC
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 42.54 € |
| Current stock | 10+ |
| Lead time | 28 days |
**|** 10/2020 ## › **GNA Series** ## **Essential Solid State Relays** Panel Mount - AC Output Single Phase - › **Output current of 25, 40, 50 and 90 Amps** - › **Output voltage of 24-280 V** a **and 48-660 V** a - › **Control voltage of 4-32 V** c - › **Zero cross (resistive loads)** **==> picture [177 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> › Integrated IP20 touch-safe removable covers<br>**----- End of picture text -----**<br> **==> picture [107 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> › LED input status indicator<br>**----- End of picture text -----**<br> **==> picture [475 x 97] intentionally omitted <==** **----- Start of picture text -----**<br> Zero Cross<br>› Cost-effective solution<br>Version<br>Product Selection - Zero Cross (Resistive Loads)<br>Rated Load Current 25A 40A 50A 90A<br>Output Voltage 24-280 V a 48-660 V a 48-660 V a 48-660 V a<br>Control Voltage<br>4-32 V c 84137910N 84137450N 84137460N 84137480N<br>**----- End of picture text -----**<br> **==> picture [386 x 181] intentionally omitted <==** **----- Start of picture text -----**<br> PART NUMBERING SYSTEM<br>Series Output Voltage Generation<br>8413: Single Phase 9: 280 V a / Zero Cross N: New Generation<br>4: 660 V a / Zero Cross<br>8413 7 9 1 0 N<br>Cover/Layout Output Control<br>7: Included Current Voltage<br>1: 25 A 0: 4-32 V c<br>5: 40 A<br>6: 50 A<br>8: 90 A<br>**----- End of picture text -----**<br> Do you need an adapted or customized solution? Contact us on **www.crouzet.com** ## **Description:** Crouzet Solid State Relays are designed to be used in almost any application, offering very long life expectancy and are easy to install, easy to use, robust and multipurpose. For more information about Crouzet’s Solid State relays, please visit **www.crouzet.com** . **|** WWW.CROUZET.COM **| 2** **|** GNA Series **|** 10/2020 **==> picture [495 x 161] intentionally omitted <==** **----- Start of picture text -----**<br> Accessories<br>Type Description Part-Number<br>Heatsink 0.9 °C/W Thermal Resistance 26532752N<br>Heatsink 1.1 °C/W Thermal Resistance 26532753N<br>Heatsink 1.2 °C/W Thermal Resistance 26532754N<br>Heatsink 1.75 °C/W Thermal Resistance 26532755N<br>Heatsink 2.2 °C/W Thermal Resistance 26532756N<br>Adapter DIN Rail 26532764N<br>Thermal Pad Self-Adhesive Thermal Pad 26532722N<br>Screws Screw Mounting Kit 26532001<br>Thermal Grease Thermal Grease for Heatsink mounting 26532003<br>**----- End of picture text -----**<br> |**Output Specifcations(1)**|**Output Specifcations(1)**|**Output Specifcations(1)**|**Output Specifcations(1)**|**Output Specifcations(1)**| |---|---|---|---|---| |**Description**|25A|40A|50A|90A| |Maximum Load Current [Arms](3)|25|40|50|90| |Minimum Load Current [mArms]|5|||| |Min / Max Operating Voltage (47-63Hz) [Vrms]|24-280 Va|48-660 Va||| |Transient Voltage [Vpk](2)|600|1200||| |Maximum Off-State Leakage Current @ Rated Voltage<br>[mArms]|1|||| |Minimum Off-State dV/dt @ Maximum Rated Voltage [V/µsec]|500|||| |1 Second Surge Current (Apk. Ta=25 °C) 50/60 Hz|100|96|165|347| |Maximum 1 Cycle Surge Current (50/60Hz) [Apeak]<br>Typ @ 50 Hz|270/284 (min)<br>340 (typ)|320/_ (min)<br>420 (typ)|530/_ (min)<br>580 (typ)|1100/_ (min)<br>1200 (typ)| |Maximum On-State Voltage Drop @ Rated Current [Vpeak]|1.22|1.23|1.22|1.4| |Thermal Resistance Junction to Case (Rjc) [°C/W]|1.7|0.7|0.55|0.3| |Maximum 1/2 Cycle I² t for Fusing @ 50 Hz (min. / typical)<br>[A² sec]|487|882|1680|7200| |Minimum Heat Sink for Rated Current @ 40 °C [°C/W]|1.3|1.05|0.85|0.33| ## **Input Specifications** |**Description**|4-32 Vc|4-32 Vc| |---|---|---| |Input Voltage Range|4-32 Vc(4)|| |Maximum Reverse Voltage|-32 Vc|| |Minimum Turn-On Voltage|3 Vc|3.5 Vc| |Must Turn-Off Voltage|1 Vc|2 Vc| |Minimum Input Current (for on-state)|10 mA|| |Maximum Input Current [mA]|14 mA|| |Nominal Input Impedance [Ohms]|Current Limited|| |Maximum Turn-On Time [msec]|1/2 Cycle(5)|| |Maximum Turn-Off Time [msec]|1/2 Cycle(5)|| ## **General Specifications** |**Description**|25A|40A|50A|90A| |---|---|---|---|---| |Dielectric Strength, Input to Output (50/60 Hz)|4000 Vrms|||| |Dielectric Strength, Input/Output to Ground (50/60 Hz)|2500 Vrms|4000 Vrms||| |Minimum Insulation Resistance (@ 500 Vc)|109Ω|||| |Maximum Capacitance, Input/Output|0.8 pF|||| |Ambient Operating Temperature Range|-40 to 80 °C|||| |Ambient Storage Temperature Range|-40 to 100 °C|||| **|** WWW.CROUZET.COM **| 3** **|** GNA Series **|** 10/2020 |**General Specifcations**|**General Specifcations**|**General Specifcations**|**General Specifcations**|**General Specifcations**| |---|---|---|---|---| |**Description**|25A|40A|50A|90A| |Weight (typical)|80 g|||| |Housing Material|UL94 V-0|||| |Baseplate Material|Aluminum|||| |Input Terminal Screw Torque Range (in-lb/Nm)|11-18 /1.2-2.0|||| |Load Terminal Screw Torque Range (in-lb/Nm)|18-26 / 2-3|||| |SSR Mounting Screw Torque Range (in-lb/Nm)|11-16 /1.2-1.8|||| |Humidity per IEC60068-2-78|40-85%|||| |LED Input Status Indicator|Green|||| |MTBF (Mean Time Between Failures) at 40 °C ambient<br>temperature (years)(5)|72|||| |MTBF (Mean Time Between Failures) at 60 °C ambient<br>temperature (years)(5)|46|||| ## **General Notes** (1)All parameters at 25 °C unless otherwise specified (2)Output will self trigger between 450-600 Vpk not suitable for capacitive loads - (3)Heat sinking required, see derating curves (4)Increase minimum voltage by 1 V for operations from -20 to -40 °C (5)All parameters at 50 % power rating and 100 % duty cycle (contact tech support for detailed report) ## **Diagrams** ## **Wiring** **==> picture [156 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> GNA -<br>**----- End of picture text -----**<br> **==> picture [75 x 156] intentionally omitted <==** **----- Start of picture text -----**<br> AC<br>V<br>1<br>1 ( a ) 2 ( a )<br>4 (-/ a ) 3 (+/ a )<br>**----- End of picture text -----**<br> |**TERMINALS**|**WIRE SIZE**|**WIRE SIZE**|**Terminal Screw**<br>**Torque (N.m)**| |---|---|---|---| ||**SOLID**|**STRANDED**|| |**Input**|18..14 AWG (0.75..2.5 mm²)<br>2 x 18..14 AWG (0.75..2.5 mm²)|18..14 AWG (0.75..2.5 mm²)<br>2 x 18..14 AWG (0.75..2.5 mm²)|1.2 - 2| |**Output**|16..8 AWG (1.5..10 mm²)<br>2 x 16..8 AWG (1.5..10 mm²)|16..8 AWG (1.5..6 mm²)<br>2 x 16..10 AWG (1.5..6 mm²)|2 - 3| Recomended overvoltage external protection: TVS Diode **==> picture [43 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> B Load<br>**----- End of picture text -----**<br> **|** WWW.CROUZET.COM **| 4** **|** GNA Series **|** 10/2020 ## **Diagrams** ## **Equivalent Circuit Block** GNA Series DC control / Thyristor 40 A / 50 A / 90 A **==> picture [236 x 50] intentionally omitted <==** **----- Start of picture text -----**<br> GNA Series DC control / Triac 25 A<br>Current Limiter<br>-DC 4 4AC<br>INPUT OUTPUT<br>**----- End of picture text -----**<br> **==> picture [187 x 281] intentionally omitted <==** **----- Start of picture text -----**<br> Input current vs Input Voltage<br>Standard Regulated DC inputs<br>14<br>12<br>10<br>t<br>8 t<br>tTH<br>6 ‘<br>4 tH<br>t<br>2 t<br>t<br>0 Lf<br>0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32<br>Input Voltage (V)<br>Input current vs Input Voltage<br>Standard Regulated DC inputs<br>14<br>12<br>10<br>t<br>8 t<br>tqlTHi<br>6 H<br>4 tf<br>'<br>2 t<br>t<br>0 Lu<br>0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32<br>Input Voltage (V)<br>Input Current (mA)<br>Input Current (mA)<br>**----- End of picture text -----**<br> ## **Diagrams** ## **Dimensions (mm)** **==> picture [184 x 152] intentionally omitted <==** **----- Start of picture text -----**<br> GNA front view<br>r 28 Ø4,7 7 2 M5<br>—<br>1 Kp<br>4,7<br>25,4 2 M4<br>59,4 47,6<br>**----- End of picture text -----**<br> **==> picture [111 x 103] intentionally omitted <==** **----- Start of picture text -----**<br> GNA side view<br>‘ AEE ee ee ee e<br>3 —<br>44,5 [(±0,3)]<br>an<br>29,1<br>16,3<br>**----- End of picture text -----**<br> **|** WWW.CROUZET.COM **| 5** **|** GNA Series **|** 10/2020 ## **Curves** ## **Surge Current Information** **==> picture [495 x 663] intentionally omitted <==** **----- Start of picture text -----**<br> GNA - 25 A GNA - 40 A<br>300 350<br>300<br>250<br>200<br>200<br>150<br>100 100<br>50<br>0 0<br>0,01 0,1 1 10 0,01 0,1 1 10<br>T (s) T (s)<br>No Repetitive Surge Current No Repetitive Surge Current<br>Repetitive Surge Current Repetitive Surge Current<br>GNA - 50 A GNA - 90 A<br>600 1200<br>1100<br>500 1000<br>900<br>400 800<br>700<br>300 600<br>500<br>200 400<br>300<br>100 200<br>100<br>0 0<br>0,01 0,1 1 10 0,01 0,1 1 10<br>T (s) T (s)<br>No Repetitive Surge Current No Repetitive Surge Current<br>Repetitive Surge Current Repetitive Surge Current<br>Curves<br>Thermal Derating Curves<br>GNA - 25 A GNA - 40 A GNA - 50 A<br>30 45 55<br>40 50<br>25 45<br>35<br>40<br>20 30 35<br>25 30<br>15<br>20 25<br>10 15 20<br>15<br>10<br>10<br>5 5<br>5<br>0 0 10 20 30 40 50 60 70 80 0 0 10 20 30 40 50 60 70 80 0 0 10 20 30 40 50 60 70 80<br>Ambient Temperature (°C) Ambient Temperature (°C)<br>Ambient Temperature (°C)<br>3 2,2 2 1,75 1,5 1,1 1 2,2 2 1,75 1,5 1 0,9 0,7 2 1,75 1,5 1,1 1 0,9 0,7<br>C°/W C°/W C°/W<br>GNA - 90 A<br>95<br>90<br>85<br>80<br>75<br>70<br>65<br>60<br>55<br>50<br>45<br>40<br>35<br>30<br>25<br>20<br>15<br>10<br>5<br>0<br>0 10 20 30 40 50 60 70 80<br>Ambient Temperature (°C)<br>1,5 1,2 1,1 0,9 0,7 0,5 0,3<br>C°/W<br>Itsm ( Apeak)<br>Itsm ( Apeak)<br>Itsm ( Apeak) Itsm ( Apeak)<br>Current (Arms) Current (Arms) Current (Arms)<br>Current (Arms)<br>**----- End of picture text -----**<br> ## **Warning:** The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form of contractual commitment. Crouzet and its subsidiaries reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products.
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →