Image not available
Illustrative purposes only
84137181N
Solid State Relay, 125 A, 660 VAC, Panel Mount, Screw, Zero Crossing
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CROUZET
- Product type:
- SVHC: Lead (21-Jan-2025)
- Load Current: 125A
- Product Range: GN Series
- Relay Mounting: Panel Mount
- Switching Mode: Zero Crossing
- Relay Terminals: Screw
- Control Voltage Max: 265VAC
- Control Voltage Min: 20VAC
- Contact Configuration: -
- Operating Voltage Max: 660VAC
- Operating Voltage Min: 48VAC
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 149.51 € |
| Current stock | 10+ |
| Lead time | 30 days |
**|** 10/2020 ## › **GN Series** ## **Classic Solid State Relays** Panel Mount - AC Output Single Phase - › **Output current of 10, 25, 50, 75, 100 and 125 Amps** - › **Output voltage of 24-280 V** a **and 48-660 V** a - › **Control voltage of 4-32 V** c **, 18-36 V** z **, 20-265 V** a **and 90-260 V** a - › **Zero cross or instantaneous (resistive or inductive loads)** - › **Integrated IP20 touch-safe removable covers** - › **Built-in overvoltage protection (only Zero Cross)** |**Rated Load Current**<br>Output Voltage|10A|25A|25A|50A|75A|100A|125A| |---|---|---|---|---|---|---|---| ||24-280 Va|24-280 Va|48-660 Va|48-660 Va|48-660 Va|48-660 Va|48-660 Va| |**Control Voltage**|||||||| |4-32 Vc|**84137000N**|**84137010N**|**84137110N**|**84137120N**|**84137130N**|**84137140N**|**84137180N**| |18-36 Vz||**84137012N**||**84137122N**|||| |20-265 Va|**84137001N**|**84137011N**|**84137111N**|**84137121N**|**84137131N**|**84137141N**|**84137181N**| - › **LED input status indicator** **==> picture [453 x 306] intentionally omitted <==** **----- Start of picture text -----**<br> Product Selection- Instantaneous (Inductive Loads)<br>Rated Load Current 25A 50A 75A<br>Output Voltage 24-280 V a 48-660 V a 48-660 V a<br>Control Voltage<br>4-32 V c 84137210N 84137320N 84137330N<br>90-260 V a 84137211N 84137321N<br>PART NUMBERING SYSTEM<br>Series Output Voltage Generation<br>8413: Single Phase 0: 280 V a / Zero Cross N: New Generation<br>1: 660 V a / Zero Cross<br>2: 280 V a / Random<br>3: 660 V a / Random<br>8413 7 0 1 1 N<br>Cover/Layout Output Current Control Voltage<br>7: Included 0: 10 A 0: 4-32 V c<br>1: 25 A 1: 20-265 V a<br>2: 50 A 2: 18-36 V z<br>3: 75 A<br>4: 100 A<br>8: 125 A<br>**----- End of picture text -----**<br> Do you need an adapted or customized solution? Contact us on **www.crouzet.com** ## **Description:** Crouzet Solid State Relays are designed to be used in almost any application, offering very long life expectancy and are easy to install, easy to use, robust and multipurpose. For more information about Crouzet’s Solid State relays, please visit **www.crouzet.com** . **|** WWW.CROUZET.COM **| 2** **|** GN Series **|** 10/2020 ## **Accessories** **==> picture [495 x 16] intentionally omitted <==** **----- Start of picture text -----**<br> Type Description Part-Number<br>**----- End of picture text -----**<br> |**Type**|**Description**|**Part-Number**| |---|---|---| |||| |Heatsink|0.9 °C/W Thermal Resistance|**26532752N**| |Heatsink|1.1 °C/W Thermal Resistance|**26532753N**| |Heatsink|1.2 °C/W Thermal Resistance|**26532754N**| |Heatsink|1.75 °C/W Thermal Resistance|**26532755N**| |Heatsink|2.2 °C/W Thermal Resistance|**26532756N**| |Adapter|DIN Rail|**26532764N**| |Thermal Pad|Pre-cut Thermal Pad|**26532720N**| |Thermal Pad|Self-Adhesive Thermal Pad|**26532722N**| |Screws|Screw Mounting Kit|**26532001**| |Thermal Grease|Thermal Grease for Heatsink mounting|**26532003**| |**Output Specifcations(1)**|**Output Specifcations(1)**|**Output Specifcations(1)**|**Output Specifcations(1)**|**Output Specifcations(1)**|**Output Specifcations(1)**|**Output Specifcations(1)**|**Output Specifcations(1)**| |---|---|---|---|---|---|---|---| |**Description**|10A|25A||50A|75A|100A|125A| |Maximum Load Current [Arms](3)|10|25||50|75|100|125| |Minimum Load Current [mArms]|5||||||| |Min / Max Operating Voltage<br>(47-63Hz) [Vrms]|24-280 Va||48-660 Va||||| |Transient Voltage [Vpeak](2)(Random<br>version)|600<br>(600)||1200<br>(1600)||||| |Maximum Off-State Leakage Current @<br>Rated Voltage [mArms]<br>(Random version)|1<br>(5)||||||| |Minimum Off-State dV/dt @ Maximum<br>Rated Voltage [V/µsec]|500||||||| |1 Second Surge Current (Apk. Ta=25 °C)<br>50/60 Hz|45|100|125|230|347||613| |Maximum 1 Cycle Surge Current (50/60 Hz)<br>[Apeak]<br>Typ @ 50 Hz|120/126<br>(min)<br>160 (typ)|270/284<br>(min)<br>340 (typ)|280/_ (min)<br>500 (typ)|700/_ (min)<br>750 (typ)|1100/_ (min)<br>1200 (typ)||2000/_<br>(min)<br>2100 (typ)| |Maximum On-State Voltage Drop @ Rated<br>Current [Vpeak]<br>(Random version)|1.2|1.23<br>(1.08)|1.25<br>(1.37)|1.38<br>(1.37)|1.34<br>(1.34)|1.45|1.15| |Thermal Resistance Junction to Case<br>(Rjc) [°C/W]<br>(Random version)|2.3|1.7<br>(0.7)|0.55<br>(0.7)|0.4<br>(0.4)|0.3<br>(0.3)||0.25| |Maximum 1/2 Cycle I² t for Fusing @ 50 Hz<br>(min. / typical) [A² sec]<br>(Random version)|78/128|487/600<br>(512/882)|720/1250<br>(512/882)|2450/2800<br>(2450/2500)|6000/7200<br>(6000/7200)|6000/7200|20000/<br>22000| |Minimum Heat Sink for Rated Current<br>@ 40 °C [°C/W]<br>(Random version)|5.3|1.3<br>(2.6)|2.08<br>(2.6)|0.84<br>(0.84)|0.52<br>(0.52)|0.23|0.29| |**Input Specifcations**|**Input Specifcations**|**Input Specifcations**|**Input Specifcations**|**Input Specifcations**| |---|---|---|---|---| |**Description**|4-32 Vc|18-36 Vz|20-265 Va|90-260 Va| |Input Voltage Range|4-32 Vc (4)|18-36 Vz|20-265 Va|90-260 Va| |Maximum Reverse Voltage|-32 Vc|N/A||| |Minimum Turn-On Voltage|3 Vc|18 Vz||90 Va| |Must Turn-Off Voltage|1 Vc|5 Vz||5 Va| |Minimum Input Current (for on-state)|10 mA|5 mA AC / 4 mA DC||6.5 mA| |Maximum Input Current [mA]|14 mA|10 mA||| |Nominal Input Impedance [Ohms]|Current Limited|||| |Maximum Turn-On Time [msec]|1/2 Cycle(5)|||< 0.1| |Maximum Turn-Off Time [msec]|1/2 Cycle(5)|||| **|** WWW.CROUZET.COM **| 3** **|** GN Series **|** 10/2020 ## **General Specifications** |**Description**|10A|25A|25A|50A|75A|100A|125A| |---|---|---|---|---|---|---|---| |Dielectric Strength, Input to Output (50/60 Hz)|4000 Vrms||||||| |Dielectric Strength, Input/Output to Ground<br>(50/60 Hz)|2500 Vrms||4000 Vrms||||| |Minimum Insulation Resistance (@ 500 Vc)|109Ω||||||| |Maximum Capacitance, Input/Output|0.8 pF||||||| |Ambient Operating Temperature Range|-40 to 80 °C||||||| |Ambient Storage Temperature Range|-40 to 100 °C||||||| |Weight (typical)|80 g||||||| |Housing Material|UL94 V-0||||||| |Baseplate Material|Aluminum||||||| |Input Terminal Screw Torque Range (in-lb/Nm)|11-18 /1.2-2.0||||||| |Load Terminal Screw Torque Range (in-lb/Nm)|18-26 / 2-3||||||| |SSR Mounting Screw Torque Range (in-lb/Nm)|11-16 /1.2-1.8||||||| |Humidity per IEC60068-2-78|40-85 %||||||| |LED Input Status Indicator|Green||||||| |MTBF (Mean Time Between Failures) at 40 °C<br>ambient temperature(5)(years)|72||||||| |MTBF (Mean Time Between Failures) at 60 °C<br>ambient temperature(5)(years)|46||||||| ## **General Notes** (1) All parameters at 25 °C unless otherwise specified (2) Output will self trigger between 450-600 Vpk not suitable for capacitive loads (3) Heat sinking required, see derating curves (4) Increase minimum voltage by 1 V for operations from -20 to -40 °C (5) All parameters at 50 % power rating and 100 % duty cycle (contact tech support for detailed report) ## **Diagrams** ## **Wiring** ## GN Recommended Wire Size **==> picture [75 x 157] intentionally omitted <==** **----- Start of picture text -----**<br> AC<br>V<br>1<br>1 ( a ) 2 ( a )<br>4 (-/ a ) 3 (+/ a )<br>**----- End of picture text -----**<br> |**TERMINALS**|**WIRE SIZE**|**WIRE SIZE**|**Terminal Screw**<br>**Torque (N.m)**| |---|---|---|---| ||**SOLID**|**STRANDED**|| |**Input**|18..14 AWG (0.75..2.5 mm²)<br>2 x 18..14 AWG (0.75..2.5 mm²)|18..14 AWG (0.75..2.5 mm²)<br>2 x 18..14 AWG (0.75..2.5 mm²)|1.2 - 2| |**Output**|16..8 AWG (1.5..10 mm²)<br>2 x 16..8 AWG (1.5..10 mm²)|16..8 AWG (1.5..6 mm²)<br>2 x 16..10 AWG (1.5..6 mm²)|2 - 3| **For the random (instantaneous) models, external overvoltage protection is recommended: TVS Diode** B _Load_ **|** WWW.CROUZET.COM **| 4** **|** GN Series **|** 10/2020 ## **Diagrams Equivalent Circuit Block** ## GN Series 4-32 V c control (Thyristors) - All out 660 V a **==> picture [236 x 39] intentionally omitted <==** **----- Start of picture text -----**<br> Current Limiter<br>_ 1)AC<br>INPUT OUTPUT<br>**----- End of picture text -----**<br> **==> picture [236 x 50] intentionally omitted <==** **----- Start of picture text -----**<br> GN Series 4-32 V c control (Triac) - 10 A /25 A (280 V a )<br>Current Limiter<br>_ 1AC<br>INPUT OUTPUT<br>**----- End of picture text -----**<br> **==> picture [236 x 50] intentionally omitted <==** **----- Start of picture text -----**<br> GN Series 18-36 V z control<br>Current Limiter<br>- © 1 AC<br>Lx<br>INPUT : , OUTPUT<br>**----- End of picture text -----**<br> **==> picture [236 x 50] intentionally omitted <==** **----- Start of picture text -----**<br> GN Series 20-265 V a control<br>Current Limiter<br>- © 1AC<br>Lx<br>INPUT ACIDC K OUTPUT<br>**----- End of picture text -----**<br> **==> picture [190 x 574] intentionally omitted <==** **----- Start of picture text -----**<br> Input current vs Input Voltage<br>Standard Regulated DC inputs<br>14<br>12<br>10 zaerrr ee en<br>)<br>8 t<br>|<br>6 t<br>U<br>4 tU<br>t<br>2 t<br>t<br>U<br>0 ne<br>0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32<br>Input Voltage (V)<br>Input current vs Input Voltage<br>Standard Regulated DC inputs<br>14<br>12<br>10<br>iia PS<br>!<br>8 !<br>!<br>6 t<br>U<br>4 U!<br>!<br>2 !<br>U<br>U<br>0 2<br>0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32<br>Input Voltage (V)<br>Input current vs Input Voltage<br>Standard Regulated AC/DC inputs<br>7<br>6 ih @-e---°<br>5 ' *>-- pene eer<br>|t weer<br>4 t<br>|<br>3 ti]<br>i]<br>2 t<br>t<br>1 tt<br>t<br>0 o t<br>0 20 40 60 80 100 120 140 160 180 200 220 240 260 280<br>Input Voltage (V)<br>Input current vs Input Voltage<br>Standard Regulated AC inputs<br>7<br>6 [ -<br>5 *s-- ee ee<br>i]i] won<br>4<br>|<br>3 ti]<br>(]<br>2 )<br>t]<br>1 tt<br>t<br>0 o t<br>0 20 40 60 80 100 120 140 160 180 200 220 240 260 280<br>Input Voltage (V)<br>Input Current (mA)<br>Input Current (mA)<br>Input Current (mA)<br>Input Current (mA)<br>**----- End of picture text -----**<br> **|** WWW.CROUZET.COM **| 5** **|** GN Series **|** 10/2020 **==> picture [236 x 75] intentionally omitted <==** **----- Start of picture text -----**<br> GN Series 4-32 V c control instantaneous<br>Current Limiter<br>-DC 4 1AC<br>INPUT OUTPUT<br>ibe+] AL<br>**----- End of picture text -----**<br> **==> picture [236 x 77] intentionally omitted <==** **----- Start of picture text -----**<br> GN Series 90-260 V a control instantaneous<br>Current Limiter<br>AC i TAC<br>INPUT Converter OUTPUT<br>AC 2ACIDCaA Y ix t| CBR<br>3 2 AC<br>**----- End of picture text -----**<br> Input current vs Input Voltage Standard Regulated DC inputs **==> picture [214 x 284] intentionally omitted <==** **----- Start of picture text -----**<br> 14<br>12<br>10<br>8 t<br>qa<br>6 t<br>4 tH<br>t<br>2 t<br>0 Lf<br>0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32<br>Input Voltage (V)<br>Input current vs Input Voltage<br>Standard Regulated AC inputs<br>9<br>8<br>7 Ueeeeorer rT<br>6 i ae ;<br>i<br>5 HJ<br>4 t<br>t<br>'<br>3 t<br>J<br>2 vt<br>t<br>1 J<br>t<br>0 lt<br>0 20 40 60 80 100 120 140 160 180 200 220 240 260<br>Input Voltage (V)<br>Input Current (mA)<br>Input Current (mA)<br>**----- End of picture text -----**<br> Input current vs Input Voltage Standard Regulated AC inputs **Diagrams Dimensions (mm)** **==> picture [358 x 153] intentionally omitted <==** **----- Start of picture text -----**<br> GN front view GN side view<br>28<br>l Ø4,7 7] 2 M5 1 flo7<br>' 7a ee ae<br>TOsees feyi<br>3<br>44,5 [(±0,3)]<br>a 1 tens<br>Sy<br>' Lr Ca<br>4,7<br>25,4 2 M4<br>29,1<br>16,3<br>59,4 47,6<br>**----- End of picture text -----**<br> **|** WWW.CROUZET.COM **| 6** **|** GN Series **|** 10/2020 ## **Curves** ## **Surge Current Information** **==> picture [248 x 632] intentionally omitted <==** **----- Start of picture text -----**<br> GN - 10 A<br>150<br>125<br>100<br>75<br>50<br>25<br>0<br>0,01 0,1 1 10<br>T (s)<br>No Repetitive Surge Current<br>Repetitive Surge Current<br>GN - 50 A<br>800<br>700<br>600<br>500<br>400<br>300<br>200<br>100<br>0<br>0,01 0,1 1 10<br>T (s)<br>No Repetitive Surge Current<br>Repetitive Surge Current<br>GN - 100 A<br>1200<br>1100<br>1000<br>900<br>800<br>700<br>600<br>500<br>400<br>300<br>200<br>100<br>0<br>0,01 0,1 1 10<br>T (s)<br>No Repetitive Surge Current<br>Repetitive Surge Current<br>GN - 25 A Instantaneous<br>350<br>300<br>250<br>200<br>150<br>100<br>50<br>0<br>0,01 0,1 1 10<br>T (s)<br>No Repetitive Surge Current<br>Repetitive Surge Current<br>Itsm (Apeak)<br>Itsm (Apeak)<br>Itsm (Apeak)<br>Itsm (Apeak)<br>**----- End of picture text -----**<br> **==> picture [248 x 632] intentionally omitted <==** **----- Start of picture text -----**<br> GN - 25 A<br>300<br>250<br>200<br>150<br>100<br>50<br>0<br>0,01 0,1 1 10<br>T (s)<br>No Repetitive Surge Current<br>Repetitive Surge Current<br>GN - 75 A<br>1200<br>1100<br>1000<br>900<br>800<br>700<br>600<br>500<br>400<br>300<br>200<br>100<br>0<br>0,01 0,1 1 10<br>T (s)<br>No Repetitive Surge Current<br>Repetitive Surge Current<br>GN - 125 A<br>2200<br>2000<br>1800<br>1600<br>1400<br>1200<br>1000<br>800<br>600<br>400<br>200<br>0<br>0,01 0,1 1 10<br>T (s)<br>No Repetitive Surge Current<br>Repetitive Surge Current<br>GN - 50 A Instantaneous<br>800<br>700<br>600<br>500<br>400<br>300<br>200<br>100<br>0<br>0,01 0,1 1 10<br>T (s)<br>No Repetitive Surge Current<br>Repetitive Surge Current<br>Itsm (Apeak)<br>Itsm (Apeak)<br>Itsm (Apeak)<br>Itsm (Apeak)<br>**----- End of picture text -----**<br> **|** WWW.CROUZET.COM **| 7** **|** GN Series **|** 10/2020 **==> picture [85 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> GN - 75 A Instantaneous<br>**----- End of picture text -----**<br> **==> picture [495 x 676] intentionally omitted <==** **----- Start of picture text -----**<br> 1200<br>1100<br>1000<br>900<br>800<br>700<br>600<br>500<br>400<br>300<br>200<br>100<br>0<br>0,01 0,1 1 10<br>T (s)<br>No Repetitive Surge Current<br>Repetitive Surge Current<br>Curves<br>Thermal Derating Curves<br>GN - 10 A GN - 25 A GN - 50 A<br>14 30 55<br>50<br>12<br>25 45<br>10 40<br>20<br>35<br>8<br>30<br>15<br>6 25<br>20<br>10<br>4 15<br>2 5 10<br>5<br>0 0 10 20 30 40 50 60 70 80 0 0 10 20 30 40 50 60 70 80 0 0 10 20 30 40 50 60 70 80<br>Ambient Temperature (°C) Ambient Temperature (°C) Ambient Temperature (°C)<br>5 3 2,2 3 2,2 2 1,75 1,5 1,1 1 2 1,5 1 0,7 0,9 1,75 2,2<br>C°/W C°/W C°/W<br>GN - 75 A GN - 100 A GN - 125 A<br>80 110 135<br>757065 1051009590 130125120115110<br>60 8580 105100<br>555045 75706560 9590858075<br>40 55 70<br>3530 504540 65605550<br>25 35 45<br>201510 30252015 4035302520<br>5 105 1510<br>0 0 10 20 30 40 50 60 70 80 0 0 10 20 30 40 50 60 70 80 50 0 10 20 30 40 50 60 70 80<br>Ambient Temperature (°C) Ambient Temperature (°C) Ambient Temperature (°C)<br>1,75 1,5 1,2 0,9 0,7 0,5 1,5 1,2 1,1 1 0,9 0,7 0,5 0,3 1,2 1,1 1 0,9 0,7 0,5 0,3<br>C°/W C°/W C°/W<br>GN - 25 A Instantaneous GN - 50 A Instantaneous GN - 75 A Instantaneous<br>30 55 80<br>75<br>50 70<br>25 45 65<br>40 60<br>55<br>20 35 50<br>30 45<br>15 40<br>25 35<br>20 30<br>10 25<br>15 20<br>10 15<br>5 10<br>5 5<br>0 0 10 20 30 40 50 60 70 80 0 0 10 20 30 40 50 60 70 80 0 0 10 20 30 40 50 60 70 80<br>Ambient Temperature (°C) Ambient Temperature (°C) Ambient Temperature (°C)<br>3 2,2 2 1,75 1,5 0,9 2 1,5 1 0,7 0,9 1,75 2,2 1,75 1,5 1,2 0,9 0,7 0,5<br>C°/W C°/W C°/W<br>Itsm (Apeak)<br>Current (Arms) Current (Arms) Current (Arms)<br>Current (Arms) Current (Arms) Current (Arms)<br>Current (Arms) Current (Arms) Current (Arms)<br>**----- End of picture text -----**<br> ## **Warning:** The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form of contractual commitment. Crouzet and its subsidiaries reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our products and it is the responsibility of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion, use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products.
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →