Image not available
Illustrative purposes only
81.01.0.230.0000
Analogue Timer, 81 Series, Multifunction, 0.1 s, 10 h, 6 Ranges, 1 Changeover Relay
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: FINDER
- Product type: Analogue Timers - DIN Rail
- Product Range:81 Series; Timer Functions:Multifunction; Time Min:0.1s; Time Max:10h; No. of Timing Ranges:6Ranges; Timer Output:1 Changeover Relay; Supply Voltage Max:230V; Current Ratin
- SVHC: No SVHC (04-Feb-2026)
- Time Max: 10h
- Time Min: 0.1s
- Timer Output: 1 Changeover Relay
- Product Range: 81 Series
- Timer Functions: Multifunction
- Current Rating Nom: 16A
- Supply Voltage Max: 230V
- No. of Timing Ranges: 6Ranges
- Connection / Termination: Screw Terminals
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 65.9 € |
| Current stock | 50+ |
| Lead time | 30 days |
**81 SERIES** **H** ## **Multi-function and multi-voltage timer** - **Multi-function and multi-voltage timer 81.01** • One module 17.5 mm wide housing - Seven functions (4 with supply start and 3 with control signal) - Additional Reset function - Six time ranges from 0.1 s to 10 h - 35 mm rail (EN 60715) mounting 81.01 Screw terminal - Multi-voltage (DC non polarized) - Multi-function - 35 mm rail (EN 60715) mounting **AI:** On-delay **DI:** Interval **SW:** Symmetrical flasher (starting pulse on) **SP:** Symmetrical flasher (starting pulse off) **BE:** Off-delay with control signal **DE:** Interval with con ~~t~~ rol signal on **EEb:** Interval with control signal off ||||A~~l~~. ~~a~~re<br>U/m~~m~~<br>N/~~-(~~+)|e<br>‘~~**)** ~~4 ~~M~~a<br>U/+4<br>N/-~~(~~+)| |---|---|---|---|---| ||||Wiring diagram|Wiring diagram<br>Wiring diagram| ||||(supply START)|(control signal)| ||**Contact specification**<br>Contact configuration|||1 CO (SPDT)| ||Rated current/Maximum peak current<br>A|||16/30| ||Rated voltage/<br>Maximum switchingvoltage|V AC||250/400| ||Rated load AC1|VA||4000| ||Rated load AC15 (230 V AC)|VA||750| ||Single phase motor rating (230 V AC)<br>kW|||0.55| ||Breaking capacity DC1: 30/110/220 V<br>A|||16/0.3/0.12| ||Minimum switching load|mW (V/mA)||500 (10/5)| ||Standard contact material<br>**Supply specification**<br>Nominal voltage (UN)|V AC (50/60 Hz)||AgCdO<br>12…230| |||V DC|12…230 (non polarized)|| ||Rated power AC/DC|VA (50 Hz)/W||< 2/< 2| ||Operating range|V AC||10.8…250| ||**Technical data**|V DC||10.8…250| ||Specified time range||(0.1…1)s, (1…10)s, (10…60)s, (1…10)min, (10…60)min, (1…10)h|| ||Repeatability|%||± 1| ||Recovery time|ms||≤ 50| ||Minimum control impulse|ms||50| |XI-2016, www.findernet.com|Setting accuracy-full range<br>Electrical life at rated load in AC1<br>Ambient temperature range<br>Protection category<br>**Approvals**(according to type)|%<br>cycles<br>°C||± 5<br>100 · 103<br>–10…+50<br>IP 20<br>Ce tl &| **1** **81 SERIES** ## **Ordering information** Example: 81 series, modular timer multi-voltage, 1 CO (SPDT) - 16 A, supply rated at (12…230)V AC/DC. **8 1 . 0 . 1 . 0 . 2 3 0 . 0 0 0 0 Series Type** 0 = Multi-function (AI, DI, SW, SP, BE, DE, EEb) **Supply voltage** 230 = (12 … 230)V AC/DC **Supply version** 0 = AC (50/60 Hz)/DC **No. of poles** 1 = 1 CO (SPDT) ## **Technical data** **==> picture [540 x 270] intentionally omitted <==** **----- Start of picture text -----**<br> EMC specifications<br>Type of test Reference standard<br>Electrostatic discharge contact discharge EN 61000-4-2 4 kV<br>air discharge EN 61000-4-2 8 kV<br>Radio-frequency electromagnetic field (80 ÷ 1000 MHz) EN 61000-4-3 10 V/m<br>Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals EN 61000-4-4 4 kV<br>Surges (1.2/50 μs) on Supply terminals common mode EN 61000-4-5 4 kV<br>differential mode EN 61000-4-5 4 kV<br>Radio-frequency common mode (0.15 ÷ 80 MHz) on Supply terminals EN 61000-4-6 10 V<br>Radiated and conducted emission EN 55022 class A<br>Other data<br>Current absorption on signal control (B1) < 1 mA (S-X) < 1 mA (R-X)<br>H Voltage potential on the input terminal R - X and S -X Not galvanic separation from the supply voltage on A1 - A2<br>Power lost to the environment without contact current W 1.3<br>with rated current W 3.2<br>Screw torque Nm 0.8<br>Max. wire size solid cable stranded cable<br> mm [2] 1 x 6 / 2 x 4 1 x 4 / 2 x 2.5<br>AWG 1 x 10 / 2 x 12 1 x 12 / 2 x 14<br>**----- End of picture text -----**<br> **==> picture [508 x 88] intentionally omitted <==** **----- Start of picture text -----**<br> Time range (0.1…1)s (1…10)s (10…60)s (1…10)min (10…60)min (1…10)h<br>setting 1 1 1 1 1 1<br>2 2 2 2 2 2<br>3 3 3 3 3 3<br>4 4 4 4 4 4<br>5 5 5 5 5 5<br>6 6 6 6 6 6<br>**----- End of picture text -----**<br> NOTE: time range and function must be set before energising the timer. **2** **81 SERIES** ## **Functions** |**ons**|||||||| |---|---|---|---|---|---|---|---| |pply voltage<br>nal switch<br>~~set~~|LED<br>(green)||LED<br>(red)|Supply<br>voltage<br>OFF|NO output<br>contact<br>O|Contacts|| |||||||Open<br>15 - 18|Closed<br>15 - 16| |tput contact||||ON|pen<br>Open|<br>15 - 18|<br>15 - 16| ||||||||| ||||||||| |||||ON|Closed|15 - 16|15 - 18| ||||||||| ||||||||| Supply Start = Start via contact in supply line (A1). Control signal = Start via contact into control terminal (X-S). ## **Wiring diagram** - Supply START ** Connection of the Reset (R-X) is optional - Control signal **==> picture [195 x 162] intentionally omitted <==** **==> picture [272 x 109] intentionally omitted <==** - Terminals R, S & X must not be directly connected to the timer supply voltage, but they should be considered to be at supply voltage potential for the purposes of insulation. **==> picture [195 x 41] intentionally omitted <==** ## **(AI) On-delay.** Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. ## **(DI) Interval.** Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. ## **(SW) Symmetrical flasher (starting pulse on).** Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ratio is 1:1 (time on = time off). ## **(SP) Symmetrical flasher (starting pulse off).** Apply power to timer. First transfer of contact occurs after preset time has elapsed. The timer now cycles between OFF and ON as long as power is applied. The ratio is 1:1 (time on = time off). ## **(BE) Off-delay with control signal.** Power is permenently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. ## **(DE) Interval with control signal on.** Power is permenently applied to the timer. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. ## **(EEb) Interval with control signal off.** Power is permenently applied to the timer. On opening of the Signal Switch (S) the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. **H** - ** Connection of the Reset (R-X) is optional ## **RESET function (R)** For each and every Example: function and time Supply START; ON delay function range, the timer is **Closing the external reset switch immediately resets the** immediately reset **timer. Opening the reset switch re-initiates the timing** when the reset switch **function.** is closed. Example: Control signal; ON pulse function. **Closing the external reset switch terminates the interval time and resets the timer. To re-start, it is necessary to open the reset switch, before closing the control signal contact.** **3** **81 SERIES** **H** |**Accessories**||| |---|---|---| ||**Identification tag,**for type 81.01, plastic, 1 tag, 17 x 25.5 mm|019.01| |**019.01**||| |**Sheet of marker tags (CEMBRE'S Thermal transfer printers)**for type 81.01, plastic,<br>48 tags, 6 x 12 mm<br>er<br>e<br>e<br>eF<br>a<br>Se 8<br>.<br>bt<br>t<br>&<br>&<br>i<br>t<br>=<br>i.<br>&<br>t<br>t<br>t<br>t-<br>2<br>&<br>&<br>t<br>i.<br>:<br>&<br>t<br>**t**<br>b**t**<br>t<br>=&||060.48| |&<br>t<br>=<br>&||| |&<br>t<br>=<br>=||| |&<br>b<br>&<br>&||| |ety<br>ty ty||| |**060.48**||| **4**
Updated at June 3, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →