8060.0304
Fuse, Industrial / Power, EKO Series, 900 A, 1.25 kV, 1 kV, 82mm x 74mm x 74mm
- Manufacturer: SCHURTER
- Product type: Industrial & Electrical Power Fuses
- SVHC: No SVHC (05-Nov-2025)
- Fuse Current: 900A
- Product Range: EKO Series
- Fuse Size Metric: 82mm x 74mm x 74mm
- Fuse Size Imperial: 3.23" x 2.91" x 2.91"
- Voltage Rating VAC: 1.25kV
- Voltage Rating VDC: 1kV
- Blow Characteristic: -
| Delivery and price | |
|---|---|
| Units per pack | 50 |
| Price | 65.84 € |
| Current stock | 10+ |
| Lead time | 30 days |
**Fuses** EKO https://www.schurter.com /PG01_2 HV Fuse, up to 1250 VAC / 1000 VDC, up to 1100 A DIN-Rail - Indicator & Microswitch Flush End - Indicator US Style Bolted Tag Bolt-on ## 500 VDC · 1000 VDC · HV Fuse See below: **Approvals and Compliances** ## **Description** - A comprehensive range of square-body fuses, engineered for industrial protection ## **Unique Selling Proposition** - Compact size - High safety and reliability - Mechanical vibration and shock resistance - Chemical load and temperature shocks resistance ## **Applications** - Charging Infrastructure - Manual Service Disconnector - Energy Storage System/ BESS: Pack, Rack, PCS, Section, Module, PDU - Power conversion devices (UPS, inverter, rectifiers, drives) - Industrial equipment (heaters, welding, metal etc. equipment) **Weblinks** pdf data sheet, html datasheet, General Product Information, DistributorStock-Check, Detailed request for product ## **Technical Data** |**Technical Data**|||| |---|---|---|---| |Rated Voltage|500 VDC, 1000 VDC|Resistance to Vibration|IEC 60068-2-64| ||(1250 VAC available for selected series)|Salt mist|IEC 60068-2-11| |Rated current|50-1100 A|Damp heat, steady state|IEC 60068-2-3| |Breaking Capacity|50 kA DC|Thermal Shock|IEC 60068-2-14| ||(100 kA AC for selected series)|Mechanical Shock|IEC 60068-2-27| |Characteristic|HV Fuse||| |Mounting|Flush End, DIN-Rail, US style bolted,||| ||Bolt-on||| |Admissible Ambient Temp.|-40°C to 125°C||| |Material: Terminals|Copper alloy, tin-plated||| |Material: Tube|Ceramic||| |Storage Conditions|-40°C to 70°C, max. 70% r.h.||| |Product Marking|, Type, Rated current, Rated Voltage,<br>Ei||| ||Breaking Capacity, Approvals||| ## **Approvals and Compliances** Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. ## **Approvals** The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: EKO **Approval Logo** **Certificates** UL Approvals CCC Approvals **Certification Body** UL CCC **Description** UR File Number: pending CCC Certificate Number: pending Circuit Protection **1** **Fuses** EKO https://www.schurter.com /PG01_2 ## **Product standards** Product standards that are referenced **Organization Design Standard** Designed according to IEC 60269-4 ) Designed according to UL 248-13 Designed according to GB/T13539.4 ## **Description** Low-voltage fuses - Part 4: Supplementary requirements for fuse-links for the protection of semiconductor devices Low voltage fuses - Part 13: Semiconductor fuses Low-volage fuses - Part 4: Supplementary requirements for fuse-links for the protection of semiconductor devices ## **Compliances** The product complies with following Guide Lines **Identification Details Initiator** CE declaration of conformity SCHURTER AG RoHS SCHURTER AG ~~©~~ China RoHS SCHURTER AG REACH SCHURTER AG ## **Description** The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. Directive RoHS 2011/65/EU, Amendment (EU) 2015/863 The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. **Dimension [mm]** EKO11 FLA (-LS) ## EKO11 DIA (-LS) **==> picture [369 x 103] intentionally omitted <==** **----- Start of picture text -----**<br> D C R<br>M8↧9.5 =i pte B 43±1<br>78±2 43±1 138±2<br>105.5±1.5<br>80±1.5 80±2<br>10.5±0.5<br>Sn<br>1)<br>ø17±0.5 81±2.5<br>59±2 81±2.5 43±1 59±2<br>43±1<br>6±0.5<br>20±1 10.5±0.5<br>**----- End of picture text -----**<br> EKO12 FLA (-LS) EKO12 UBA (-LS) **==> picture [124 x 91] intentionally omitted <==** **----- Start of picture text -----**<br> ) GB )<br>M8↧9<br>i}) e© © l<br>80±2 51±1<br>81±1.5<br>ae<br>ø20±0.5<br>89±2.5<br>67±2<br>51±1<br>**----- End of picture text -----**<br> **==> picture [154 x 100] intentionally omitted <==** **----- Start of picture text -----**<br> . y)<br>fi " @ 51±1<br>133±2<br>106±1.5<br>81±2<br>[AL<br>| Ea ee) 17±0.5<br>89±2.5<br>67±2<br>51±1<br>6±0.5<br>11±0.5<br>25±1<br>**----- End of picture text -----**<br> Circuit Protection **2** **Fuses** https://www.schurter.com /PG01_2 EKO EKO13 FLA (-LS) **==> picture [129 x 110] intentionally omitted <==** **----- Start of picture text -----**<br> M10↧9<br>80±2 58±1<br>81±1.5<br>ø24±0.5<br>96±2.5<br>74±2<br>58±1<br>**----- End of picture text -----**<br> EKO14 FLA (-LS) **==> picture [141 x 126] intentionally omitted <==** **----- Start of picture text -----**<br> M12↧10<br>80±2 74±2<br>82±1.5<br>112±2.5<br>ø30±0.5 74±2 90±2.5<br>**----- End of picture text -----**<br> EKO13 DIA (-LS) **==> picture [169 x 124] intentionally omitted <==** **----- Start of picture text -----**<br> 58±1<br>137±2<br>107±1.5<br>81±2<br>11±0.5<br>96±2.5<br>74±2<br>58±1<br>6±0.5<br>32±1 11±0.5<br>**----- End of picture text -----**<br> EKO14 DIA (-LS) **==> picture [156 x 126] intentionally omitted <==** **----- Start of picture text -----**<br> 74±2<br>139±2<br>107±1.5<br>81±2<br>11±0.5<br>6±0.5 112±2.5<br>74±2 90±2.5<br>32±1 11±0.5<br>**----- End of picture text -----**<br> EKO81 BOA **==> picture [127 x 98] intentionally omitted <==** **----- Start of picture text -----**<br> 58±1 36±1<br>14±0.5<br>75±1.5<br>96±2<br>2±0.3<br>23.5±1<br>32±1<br>8.8±0.5<br>**----- End of picture text -----**<br> ## **Assembly Instructions** **==> picture [213 x 135] intentionally omitted <==** **----- Start of picture text -----**<br> Mounting:<br>-FL(*)<br>Flush End<br>Mounting:<br>-DI(*)<br>DIN-Rail<br>Mounting:<br>-UB(*)<br>US Style Bolted Tag<br>Accessory:<br>-LN<br>Indicator<br>Accessory:<br>-LS<br>Indicator with microswitch<br>**----- End of picture text -----**<br> Remark: (*) stand for terminal size variable, e.g. FLA, DIA, etc. Circuit Protection **3** **Fuses** EKO https://www.schurter.com /PG01_2 ## **Derating Curves** **==> picture [226 x 139] intentionally omitted <==** **----- Start of picture text -----**<br> 1.10<br>1.00<br>0.90<br>0.80<br>0.70<br>0.60<br>0.50<br>10 20 30 40 50 60 70 80 90 100 110 120 130<br>Ambient Temperature [°C]<br>Percentage of Rating [%]<br>**----- End of picture text -----**<br> ## **Pre-Arcing Time** **==> picture [144 x 37] intentionally omitted <==** **----- Start of picture text -----**<br> Rated Current In 5.0 x In min. 8.0 x In min.<br>50 A - 1100 A 1 s 0.02 s<br>**----- End of picture text -----**<br> ## **Time-Current-Curves** EKO11 160-400 A EKO12 125-630 A **==> picture [420 x 230] intentionally omitted <==** **----- Start of picture text -----**<br> 10000 10000<br>1000 1000<br>100 100 125A<br>160A<br>250A<br>160A 315A<br>10 10<br>200A 350A<br>400A<br>250A<br>500A<br>1 315A 1 630A<br>350A<br>400A<br>0.1 0.1<br>0.01 0.01<br>0.001 0.001<br>10 100 1000 10000 100 1000 10000<br>Current in Amperes Current in Amperes<br>Time in Seconds Time in Seconds<br>**----- End of picture text -----**<br> Circuit Protection **4** **Fuses** https://www.schurter.com /PG01_2 EKO ## EKO13 250-800 A **==> picture [178 x 196] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000<br>100<br>10 250A<br>500A<br>630A<br>800A<br>1<br>0.1<br>0.01<br>0.001<br>100 1000 10000<br>Time in Seconds<br>**----- End of picture text -----**<br> Current in Amperes ## EKO14 315-1100 A **==> picture [130 x 219] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000<br>100<br>315A<br>630A<br>800A<br>10 900A<br>1100A<br>1<br>0.1<br>0.01<br>0.001<br>100 1000 10000<br>**----- End of picture text -----**<br> **==> picture [7 x 50] intentionally omitted <==** **----- Start of picture text -----**<br> Time in Seconds<br>**----- End of picture text -----**<br> Current in Amperes ## EKO81 50-400 A, 500 VDC **==> picture [192 x 220] intentionally omitted <==** **----- Start of picture text -----**<br> 10000<br>1000<br>50A<br>100 250A<br>350A<br>400A<br>10<br>1<br>0.1<br>0.01<br>0.001<br>10 100 1000 10000<br>Time in Seconds<br>**----- End of picture text -----**<br> Current in Amperes ## **Variants** **==> picture [526 x 93] intentionally omitted <==** **----- Start of picture text -----**<br> Product Rated Rated Rated Moun- Length Width Height Indica- Micro Brea- Pre-arcing Melting I²t Power Packa- Order<br>Series Current Voltage Voltage ting [mm] [mm] [mm] tor Switch king I²t typ. typ. [kA²s] Dissipa- ging Number<br>[A] [VDC] [VAC] Capa- [kA²s] tion 1.0 [PCS]<br>city In typ.<br>[W]<br>EKO11 160 1000 1250 FLA 80 43 43 2) 18.3 50.4 44 l l 60 8060.0025<br>EKO11 200 1000 1250 FLA 80 43 43 2) 28.5 78.8 54 l l 60 8060.0026<br>EKO11 250 1000 1250 FLA 80 43 43 2) 44.6 123.1 64 l l 60 8060.0027<br>**----- End of picture text -----**<br> Circuit Protection **5** **Fuses** https://www.schurter.com /PG01_2 ## EKO **==> picture [526 x 725] intentionally omitted <==** **----- Start of picture text -----**<br> Product Rated Rated Rated Moun- Length Width Height Indica- Micro Brea- Pre-arcing Melting I²t Power Packa- Order<br>Series Current Voltage Voltage ting [mm] [mm] [mm] tor Switch king I²t typ. typ. [kA²s] Dissipa- ging Number<br>[A] [VDC] [VAC] Capa- [kA²s] tion 1.0 [PCS]<br>city In typ.<br>[W]<br>EKO11 315 1000 1250 FLA 80 43 43 2) 70.8 195.4 80 l l 60 8060.0028<br>EKO11 350 1000 1250 FLA 80 43 43 2) 87.4 241.2 88 l l 60 8060.0029<br>EKO11 400 1000 1250 FLA 80 43 43 2) 114.1 315.1 97 l l 60 8060.0030<br>EKO11 160 1000 1250 FLA 80 43 43 l 2) 18.3 50.4 44 l l 60 8060.0036<br>EKO11 200 1000 1250 FLA 80 43 43 l 2) 28.5 78.8 54 l l 60 8060.0037<br>EKO11 250 1000 1250 FLA 80 43 43 l 2) 44.6 123.1 64 l l 60 8060.0038<br>EKO11 315 1000 1250 FLA 80 43 43 l 2) 70.8 195.4 80 l l 60 8060.0039<br>EKO11 350 1000 1250 FLA 80 43 43 l 2) 87.4 241.2 88 l l 60 8060.0040<br>EKO11 400 1000 1250 FLA 80 43 43 l 2) 114.1 315.1 97 l l 60 8060.0041<br>EKO11 160 1000 1250 FLA 80 43 43 l l 2) 18.3 50.4 44 l l 60 3-158-362<br>EKO11 200 1000 1250 FLA 80 43 43 l l 2) 28.5 78.8 54 l l 60 3-158-363<br>EKO11 250 1000 1250 FLA 80 43 43 l l 2) 44.6 123.1 64 l l 60 3-158-364<br>EKO11 315 1000 1250 FLA 80 43 43 l l 2) 70.8 195.4 80 l l 60 3-158-365<br>EKO11 350 1000 1250 FLA 80 43 43 l l 2) 87.4 241.2 88 l l 60 3-158-366<br>EKO11 400 1000 1250 FLA 80 43 43 l l 2) 114.1 315.1 97 l l 60 3-158-367<br>EKO11 160 1000 1250 DIA 80 43 43 2) 18.3 50.4 44 l l 60 8060.0065<br>EKO11 200 1000 1250 DIA 80 43 43 2) 28.5 78.8 54 l l 60 8060.0066<br>EKO11 250 1000 1250 DIA 80 43 43 2) 44.6 123.1 64 l l 60 8060.0067<br>EKO11 315 1000 1250 DIA 80 43 43 2) 70.8 195.4 80 l l 60 8060.0068<br>EKO11 350 1000 1250 DIA 80 43 43 2) 87.4 241.2 88 l l 60 8060.0069<br>EKO11 400 1000 1250 DIA 80 43 43 2) 114.1 315.1 97 l l 60 8060.0070<br>EKO11 160 1000 1250 DIA 80 43 43 l 2) 18.3 50.4 44 l l 60 8060.0076<br>EKO11 200 1000 1250 DIA 80 43 43 l 2) 28.5 78.8 54 l l 60 8060.0077<br>EKO11 250 1000 1250 DIA 80 43 43 l 2) 44.6 123.1 64 l l 60 8060.0078<br>EKO11 315 1000 1250 DIA 80 43 43 l 2) 70.8 195.4 80 l l 60 8060.0079<br>EKO11 350 1000 1250 DIA 80 43 43 l 2) 87.4 241.2 88 l l 60 8060.0080<br>EKO11 400 1000 1250 DIA 80 43 43 l 2) 114.1 315.1 97 l l 60 8060.0081<br>EKO11 160 1000 1250 DIA 80 43 43 l l 2) 18.3 50.4 44 l l 60 3-158-368<br>EKO11 200 1000 1250 DIA 80 43 43 l l 2) 28.5 78.8 54 l l 60 3-158-369<br>EKO11 250 1000 1250 DIA 80 43 43 l l 2) 44.6 123.1 64 l l 60 3-158-387<br>EKO11 315 1000 1250 DIA 80 43 43 l l 2) 70.8 195.4 80 l l 60 3-158-388<br>EKO11 350 1000 1250 DIA 80 43 43 l l 2) 87.4 241.2 88 l l 60 3-158-466<br>EKO11 400 1000 1250 DIA 80 43 43 l l 2) 114.1 315.1 97 l l 60 3-158-389<br>EKO12 125 1000 500 FLA 81 51 51 1) 12 37.4 32 l l 60 8060.0140<br>EKO12 160 1000 500 FLA 81 51 51 1) 19.7 61.3 40 l l 60 8060.0141<br>EKO12 250 1000 500 FLA 81 51 51 1) 48.1 149.6 56 l l 60 8060.0143<br>EKO12 315 1000 500 FLA 81 51 51 1) 76.4 237.5 67 l l 60 8060.0144<br>EKO12 350 1000 500 FLA 81 51 51 1) 94.3 293.2 73 l l 60 8060.0145<br>EKO12 400 1000 500 FLA 81 51 51 1) 123.2 383 83 l l 60 8060.0146<br>EKO12 500 1000 500 FLA 81 51 51 1) 192.4 598.4 102 l l 60 8060.0148<br>EKO12 630 1000 500 FLA 81 51 51 1) 305.5 950 129 l l 60 8060.0149<br>EKO12 125 1000 500 FLA 81 51 51 l 1) 12 37.4 32 l l 60 8060.0150<br>EKO12 160 1000 500 FLA 81 51 51 l 1) 19.7 61.3 40 l l 60 8060.0151<br>EKO12 250 1000 500 FLA 81 51 51 l 1) 48.1 149.6 56 l l 60 8060.0153<br>EKO12 315 1000 500 FLA 81 51 51 l 1) 76.4 237.5 67 l l 60 8060.0154<br>**----- End of picture text -----**<br> Circuit Protection **6** **Fuses** https://www.schurter.com /PG01_2 EKO **==> picture [526 x 725] intentionally omitted <==** **----- Start of picture text -----**<br> Product Rated Rated Rated Moun- Length Width Height Indica- Micro Brea- Pre-arcing Melting I²t Power Packa- Order<br>Series Current Voltage Voltage ting [mm] [mm] [mm] tor Switch king I²t typ. typ. [kA²s] Dissipa- ging Number<br>[A] [VDC] [VAC] Capa- [kA²s] tion 1.0 [PCS]<br>city In typ.<br>[W]<br>EKO12 350 1000 500 FLA 81 51 51 l 1) 94.3 293.2 73 l l 60 8060.0155<br>EKO12 400 1000 500 FLA 81 51 51 l 1) 123.2 383 83 l l 60 8060.0156<br>EKO12 500 1000 500 FLA 81 51 51 l 1) 192.4 598.4 102 l l 60 8060.0158<br>EKO12 630 1000 500 FLA 81 51 51 l 1) 305.5 950 129 l l 60 8060.0159<br>EKO12 125 1000 500 FLA 81 51 51 l l 1) 12 37.4 32 l l 60 3-158-390<br>EKO12 160 1000 500 FLA 81 51 51 l l 1) 19.7 61.3 40 l l 60 3-158-397<br>EKO12 250 1000 500 FLA 81 51 51 l l 1) 48.1 149.6 56 l l 60 3-158-391<br>EKO12 315 1000 500 FLA 81 51 51 l l 1) 76.4 237.5 67 l l 60 3-158-392<br>EKO12 350 1000 500 FLA 81 51 51 l l 1) 94.3 293.2 73 l l 60 3-158-393<br>EKO12 400 1000 500 FLA 81 51 51 l l 1) 123.2 383 83 l l 60 3-158-394<br>EKO12 500 1000 500 FLA 81 51 51 l l 1) 192.4 598.4 102 l l 60 3-158-395<br>EKO12 630 1000 500 FLA 81 51 51 l l 1) 305.5 950 129 l l 60 3-158-396<br>EKO12 125 1000 500 UBA 81 51 51 1) 12 37.4 32 l l 60 8060.0170<br>EKO12 160 1000 500 UBA 81 51 51 1) 19.7 61.3 40 l l 60 8060.0171<br>EKO12 250 1000 500 UBA 81 51 51 1) 48.1 149.6 56 l l 60 8060.0173<br>EKO12 315 1000 500 UBA 81 51 51 1) 76.4 237.5 67 l l 60 8060.0174<br>EKO12 350 1000 500 UBA 81 51 51 1) 94.3 293.2 73 l l 60 8060.0175<br>EKO12 400 1000 500 UBA 81 51 51 1) 123.2 383 83 l l 60 8060.0176<br>EKO12 500 1000 500 UBA 81 51 51 1) 192.4 598.4 102 l l 60 8060.0178<br>EKO12 630 1000 500 UBA 81 51 51 1) 305.5 950 129 l l 60 8060.0179<br>EKO12 125 1000 500 UBA 81 51 51 l 1) 12 37.4 32 l l 60 8060.0180<br>EKO12 160 1000 500 UBA 81 51 51 l 1) 19.7 61.3 40 l l 60 8060.0181<br>EKO12 250 1000 500 UBA 81 51 51 l 1) 48.1 149.6 56 l l 60 8060.0183<br>EKO12 315 1000 500 UBA 81 51 51 l 1) 76.4 237.5 67 l l 60 8060.0184<br>EKO12 350 1000 500 UBA 81 51 51 l 1) 94.3 293.2 73 l l 60 8060.0185<br>EKO12 400 1000 500 UBA 81 51 51 l 1) 123.2 383 83 l l 60 8060.0186<br>EKO12 500 1000 500 UBA 81 51 51 l 1) 192.4 598.4 102 l l 60 8060.0188<br>EKO12 630 1000 500 UBA 81 51 51 l 1) 305.5 950 129 l l 60 8060.0189<br>EKO12 125 1000 500 UBA 81 51 51 l l 1) 12 37.4 32 l l 60 3-158-398<br>EKO12 160 1000 500 UBA 81 51 51 l l 1) 19.7 61.3 40 l l 60 3-159-088<br>EKO12 250 1000 500 UBA 81 51 51 l l 1) 48.1 149.6 56 l l 60 3-158-465<br>EKO12 315 1000 500 UBA 81 51 51 l l 1) 76.4 237.5 67 l l 60 3-158-401<br>EKO12 350 1000 500 UBA 81 51 51 l l 1) 94.3 293.2 73 l l 60 3-158-402<br>EKO12 400 1000 500 UBA 81 51 51 l l 1) 123.2 383 83 l l 60 3-158-403<br>EKO12 500 1000 500 UBA 81 51 51 l l 1) 192.4 598.4 102 l l 60 3-158-404<br>EKO12 630 1000 500 UBA 81 51 51 l l 1) 305.5 950 129 l l 60 3-158-405<br>EKO13 250 1000 1250 FLA 81 58 58 2) 29.8 93.1 58 l 24 8060.0210<br>EKO13 500 1000 1250 FLA 81 58 58 2) 119.1 372.3 100 l 24 8060.0215<br>EKO13 630 1000 1250 FLA 81 58 58 2) 189.1 591 127 l 24 8060.0216<br>EKO13 800 1000 1250 FLA 81 58 58 2) 305 953 205 l 24 8060.0218<br>EKO13 250 1000 1250 FLA 81 58 58 l 2) 29.8 93.1 58 l 24 8060.0219<br>EKO13 500 1000 1250 FLA 81 58 58 l 2) 119.1 372.3 100 l 24 8060.0224<br>EKO13 630 1000 1250 FLA 81 58 58 l 2) 189.1 591 127 l 24 8060.0225<br>EKO13 800 1000 1250 FLA 81 58 58 l 2) 305 953 205 l 24 8060.0227<br>EKO13 250 1000 1250 FLA 81 58 58 l l 2) 29.8 93.1 58 l 24 3-158-406<br>**----- End of picture text -----**<br> Circuit Protection **7** **Fuses** https://www.schurter.com /PG01_2 EKO **==> picture [526 x 725] intentionally omitted <==** **----- Start of picture text -----**<br> Product Rated Rated Rated Moun- Length Width Height Indica- Micro Brea- Pre-arcing Melting I²t Power Packa- Order<br>Series Current Voltage Voltage ting [mm] [mm] [mm] tor Switch king I²t typ. typ. [kA²s] Dissipa- ging Number<br>[A] [VDC] [VAC] Capa- [kA²s] tion 1.0 [PCS]<br>city In typ.<br>[W]<br>EKO13 500 1000 1250 FLA 81 58 58 l l 2) 119.1 372.3 100 l 24 3-158-407<br>EKO13 630 1000 1250 FLA 81 58 58 l l 2) 189.1 591 127 l 24 3-158-408<br>EKO13 800 1000 1250 FLA 81 58 58 l l 2) 305 953 205 l 24 3-158-409<br>EKO13 250 1000 1250 DIA 81 58 58 2) 29.8 93.1 58 l 24 8060.0240<br>EKO13 500 1000 1250 DIA 81 58 58 2) 119.1 372.3 100 l 24 8060.0245<br>EKO13 630 1000 1250 DIA 81 58 58 2) 189.1 591 127 l 24 8060.0246<br>EKO13 800 1000 1250 DIA 81 58 58 2) 305 953 205 l 24 8060.0248<br>EKO13 250 1000 1250 DIA 81 58 58 l 2) 29.8 93.1 58 l 24 8060.0249<br>EKO13 500 1000 1250 DIA 81 58 58 l 2) 119.1 372.3 100 l 24 8060.0254<br>EKO13 630 1000 1250 DIA 81 58 58 l 2) 189.1 591 127 l 24 8060.0255<br>EKO13 800 1000 1250 DIA 81 58 58 l 2) 305 953 205 l 24 8060.0257<br>EKO13 250 1000 1250 DIA 81 58 58 l l 2) 29.8 93.1 58 l 24 3-158-410<br>EKO13 500 1000 1250 DIA 81 58 58 l l 2) 119.1 372.3 100 l 24 3-158-411<br>EKO13 630 1000 1250 DIA 81 58 58 l l 2) 189.1 591 127 l 24 3-158-412<br>EKO13 800 1000 1250 DIA 81 58 58 l l 2) 305 953 205 l 24 3-158-413<br>EKO14 315 1000 1250 FLA 82 74 74 2) 130.4 250.1 87 l 24 8060.0290<br>EKO14 630 1000 1250 FLA 82 74 74 2) 521.5 1000.5 162 l 24 8060.0299<br>EKO14 800 1000 1250 FLA 82 74 74 2) 841 1613.2 198 l 24 8060.0302<br>EKO14 900 1000 1250 FLA 82 74 74 2) 1064.4 2041.7 223 l 24 8060.0304<br>EKO14 1100 1000 1250 FLA 82 74 74 2) 1590 3050 266 l 24 8060.0307<br>EKO14 315 1000 1250 FLA 82 74 74 l 2) 130.4 250.1 87 l 24 8060.0308<br>EKO14 630 1000 1250 FLA 82 74 74 l 2) 521.5 1000.5 162 l 24 8060.0317<br>EKO14 800 1000 1250 FLA 82 74 74 l 2) 841 1613.2 198 l 24 8060.0320<br>EKO14 900 1000 1250 FLA 82 74 74 l 2) 1064.4 2041.7 223 l 24 8060.0322<br>EKO14 1100 1000 1250 FLA 82 74 74 l 2) 1590 3050 266 l 24 8060.0325<br>EKO14 315 1000 1250 FLA 82 74 74 l l 2) 130.4 250.1 87 l 24 3-158-415<br>EKO14 630 1000 1250 FLA 82 74 74 l l 2) 521.5 1000.5 162 l 24 3-158-416<br>EKO14 800 1000 1250 FLA 82 74 74 l l 2) 841 1613.2 198 l 24 3-158-417<br>EKO14 900 1000 1250 FLA 82 74 74 l l 2) 1064.4 2041.7 223 l 24 3-158-418<br>EKO14 1100 1000 1250 FLA 82 74 74 l l 2) 1590 3050 266 l 24 3-158-419<br>EKO14 315 1000 1250 DIA 82 74 74 2) 130.4 250.1 87 l 12 8060.0398<br>EKO14 630 1000 1250 DIA 82 74 74 2) 521.5 1000.5 162 l 12 8060.0407<br>EKO14 800 1000 1250 DIA 82 74 74 2) 841 1613.2 198 l 12 8060.0410<br>EKO14 900 1000 1250 DIA 82 74 74 2) 1064.4 2041.7 223 l 12 8060.0412<br>EKO14 1100 1000 1250 DIA 82 74 74 2) 1590 3050 266 l 12 8060.0415<br>EKO14 315 1000 1250 DIA 82 74 74 l 2) 130.4 250.1 87 l 12 8060.0416<br>EKO14 630 1000 1250 DIA 82 74 74 l 2) 521.5 1000.5 162 l 12 8060.0425<br>EKO14 800 1000 1250 DIA 82 74 74 l 2) 841 1613.2 198 l 12 8060.0428<br>EKO14 900 1000 1250 DIA 82 74 74 l 2) 1064.4 2041.7 223 l 12 8060.0430<br>EKO14 1100 1000 1250 DIA 82 74 74 l 2) 1590 3050 266 l 12 8060.0433<br>EKO14 315 1000 1250 DIA 82 74 74 l l 2) 130.4 250.1 87 l 12 3-158-420<br>EKO14 630 1000 1250 DIA 82 74 74 l l 2) 521.5 1000.5 162 l 12 3-158-422<br>EKO14 800 1000 1250 DIA 82 74 74 l l 2) 841 1613.2 198 l 12 3-158-423<br>EKO14 900 1000 1250 DIA 82 74 74 l l 2) 1064.4 2041.7 223 l 12 3-158-424<br>EKO14 1100 1000 1250 DIA 82 74 74 l l 2) 1590 3050 266 l 12 3-158-425<br>**----- End of picture text -----**<br> Circuit Protection **8** **Fuses** https://www.schurter.com /PG01_2 EKO **==> picture [526 x 107] intentionally omitted <==** **----- Start of picture text -----**<br> Product Rated Rated Rated Moun- Length Width Height Indica- Micro Brea- Pre-arcing Melting I²t Power Packa- Order<br>Series Current Voltage Voltage ting [mm] [mm] [mm] tor Switch king I²t typ. typ. [kA²s] Dissipa- ging Number<br>[A] [VDC] [VAC] Capa- [kA²s] tion 1.0 [PCS]<br>city In typ.<br>[W]<br>EKO81 50 500 - BOA 58 36 23.5 1) 2.7 7.3 9 l 180 3-158-849<br>EKO81 250 500 - BOA 58 36 23.5 1) 67.9 182.2 44 l 180 3-158-850<br>EKO81 350 500 - BOA 58 36 23.5 1) 133 357.2 63 l 180 3-158-851<br>EKO81 400 500 - BOA 58 36 23.5 1) 173.7 466.5 77 l 180 3-158-852<br>**----- End of picture text -----**<br> Availability for all products can be searched real-time: https://www.schurter.com/en/info-center/support-tools/stock-check-distributors Breaking Capacity 1) 50kA@10ms 2) AC100kA/DC50kA@10ms The specifications, descriptions and illustrations indicated in this document are based on current ~~information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.~~ Circuit Protection **9**
Updated at April 29, 2026
SCHURTER is a globally recognized innovator and manufacturer of high-quality electronic components, specializing in products that ensure a safe and clean supply of power. With a strong reputation in the electronics and PCB assembly industries, the company delivers reliable solutions engineered to protect critical circuits, streamline device operation, and optimize electrical performance across diverse applications. The core of our SCHURTER portfolio revolves around comprehensive circuit protection. We carry an extensive selection of standard and resettable fuses, accompanied by robust fuse holders, to safeguard sensitive electronics against overcurrent conditions. Furthermore, our offering features high-performance thermal circuit breakers and associated accessories, providing dependable protection and rapid reset capabilities for demanding industrial and commercial environments. Beyond fundamental circuit protection, SCHURTER excels in electromagnetic compatibility (EMC) and RFI suppression technologies. Our range includes precision-engineered power line filters and common mode chokes designed to mitigate electromagnetic interference and ensure signal integrity. Accompanied by specialized components such as AC/DC LED power supplies, SCHURTER provides the meticulous engineering and durability necessary for modern, high-reliability electronic design.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →