Image not available
Illustrative purposes only
7PV1518-1AJ30
Time Delay Relay, 127 VDC, 0.05 s, 100 h, 7PV Series, 1CO, DIN Rail
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Time Delay Relays - Electromechanical
- Product Range: SIRIUS Series
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 33.08 € |
| Current stock | 10+ |
| Lead time | 30 days |
**7PV1518-1AJ30** **Data sheet** Timing relay, electronic ON delay 1 change-over contact, 7 time ranges 0.05 s...100 h 110 V AC/DC, 0.7...1.15 x US Screw terminal |ExxK<br>i<br>ics<br>Figure similar|Timing relay, electronic ON delay 1 change-over contact, 7 time ranges 0.05<br>s...100 h 110 V AC/DC, 0.7...1.15 x US Screw terminal| |---|---| |**product brand name**|SIRIUS| |**product designation**|timingrelay| |**design of theproduct**|slow-operating| |**product type designation**|7PV15| |**General technical data**<br>~~eee~~|| |product component semi-conductor output<br>~~eee~~|No<br>~~eee~~| |**product extension required remote control**|No| |**product extension optional remote control**|No| |**power loss[W] maximum**|2 W| |insulation voltage for overvoltage category III according to IEC<br>60664 with degree ofpollution 3 rated value|300 V| |**test voltage for isolation test**|2.2 kV| |**degree ofpollution**|2| |**surge voltage resistance rated value**|4 000 V| |**test voltage for surge voltage test**|4 800 V| |**shock resistance according to IEC 60068-2-27**|11g/ 15 ms| |**vibration resistance according to IEC 60068-2-6**|10 ... 55 Hz: 0.35 mm| |**mechanical service life(operating cycles) typical**|10 000 000| |electrical endurance(operatingcycles)at AC-15 at 230 V typical|100 000| |**adjustable time**|0.05 s ... 100 h| |**relative setting accuracy relating to full-scale value**|5 %; +/-| |**ONperiod/maximum minimum**|35 ms| |**recovery time**|500 ms| |**reference code according to IEC 81346-2**|K| |**relative repeat accuracy**|2 %; +/-| |**influence of the surrounding temperature**|2% in complete temperature range for the set duration| |**power supply influence**|2% in complete voltage range for the set duration| |**Substance Prohibitance(day/month/year)**|05/01/2012| |**SVHC substance name**|Lead CAS-No. 7439-92-1<br>Lead monoxide (lead oxide) CAS-No. 1317-36-8<br>2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-<br>10-5<br>Melamine CAS-No. 108-78-1| |**Net Weight**|68g| |**Control circuit/ Control**<br>~~ee~~|| |**type of voltage of the control supply voltage**<br>~~ee~~|AC/DC<br>~~ee~~| |**control supply voltage at AC**|| |● at 50 Hz rated value|90 ... 127 V| |● at 60 Hz rated value|90 ... 127 V| Subject to change without notice © Copyright Siemens 7PV15181AJ30 Page 1/6 6/4/2026 ||**control supply voltage 1 at AC**||| |---|---|---|---| ||● at 50 Hz|90 ... 127 V|| ||● at 60 Hz|90 ... 127 V|| ||**control supply voltage frequency 1**|50 ... 60 Hz|| ||**control supply voltage at DC rated value**|90 ... 127 V|| ||**control supply voltage 1 at DC**|90 ... 127 V|| ||**operating range factor control supply voltage rated value at**<br>**DC**||| ||● initial value|0.85|| ||● full-scale value|1.1|| ||**operating range factor control supply voltage rated value at**<br>**AC at 50 Hz**||| ||● initial value|0.85|| ||● full-scale value|1.1|| ||**operating range factor control supply voltage rated value at**<br>**AC at 60 Hz**||| ||● initial value|0.85|| ||● full-scale value|1.1|| ||**Switching Function**||| ||**switching function**||| ||● ON-delay|Yes|| ||● ON-delay/instantaneous contact|No|| ||●passingmake contact|No|| ||●passingmake contact/instantaneous contact|No|| ||● OFF delay|No|| ||**switching function**||| ||● flashingsymmetricallywith interval start/instantaneous|No|| ||● flashingsymmetricallywith interval start|No|| ||● flashingsymmetricallywithpulse start/instantaneous|No|| ||● flashingsymmetricallywithpulse start|No|| ||● flashingasymmetricallywith interval start|No|| ||● flashingasymmetricallywithpulse start|No|| ||**switching function**||| ||● star-delta circuit with delaytime|No|| ||● star-delta circuit|No|| ||**switching function with control signal**||| ||● additive ON-delay|No|| ||●passingbreak contact|No|| ||●passingbreak contact/instantaneous|No|| ||● OFF delay|No|| ||● OFF delay/instantaneous|No|| ||●pulse delayed|No|| ||●pulse delayed/instantaneous|No|| ||●pulse-shaping|No|| ||●pulse-shaping/instantaneous|No|| ||● additive ON-delay/instantaneous|No|| ||● ON-delay/OFF-delay|No|| ||● ON-delay/OFF-delay/instantaneous|No|| ||●passingmake contact|No|| ||●passingmake contact/instantaneous contact|No|| ||**switching function of interval relay with control signal**||| ||● retrotriggerable with deactivated control<br>signal/instantaneous contact|No|| ||● retrotriggerable with switched-on control signal|No|| ||● retrotriggerable with switched-on control<br>signal/instantaneous contact|No|| ||● retriggerable with deactivated control signal|No|| ||**design of the control terminal non-floating**|Yes|| ||**Short-circuit protection**||| ||design of the fuse link for short-circuit protection of the auxiliary<br>switch required|fuse gL/gG: 4 A|| Subject to change without notice © Copyright Siemens 7PV15181AJ30 Page 2/6 6/4/2026 |**Auxiliary circuit**|**Auxiliary circuit**| |---|---| |**material of switching contacts**|AgSnO2| |**number of NC contacts**|| |● delayed switching|0| |● instantaneous contact|0| |**number of NO contacts**|| |● delayed switching|0| |● instantaneous contact|0| |**number of CO contacts**|| |● delayed switching|1| |● instantaneous contact|0| |**operational current of auxiliary contacts at AC-15**|| |● maximum|3 A| |● at 24 V|3 A| |● at 250 V|3 A| |**operational current of auxiliary contacts as NC contact at**<br>**AC-15**|| |● at 24 V|3 A| |● at 250 V|3 A| |**operational current of auxiliary contacts as NO contact at**<br>**AC-15**|| |● at 24 V|3 A| |● at 250 V|3 A| |**operational current of auxiliary contacts at DC-13**|1 ... 0.01| |**operational current of auxiliary contacts at DC-13**|| |● at 24 V|1 A| |● at 125 V|0.22 A| |● at 250 V|0.1 A| |**operating frequency with 3RT2 contactor maximum**|5 000 1/h| |**contact reliability of auxiliary contacts**|one incorrect switching operation of 100 million switching operations (17 V, 5<br>mA)| |**contact rating of auxiliary contacts according to UL**|R150 / B300| |**switching capacity current with inductive load**|0.01 ... 3 A| |**Inputs/ Outputs**|| |**product function**|| |● at the relayoutputs switchover delayed/without delay|No| |● non-volatile|No| |**Electromagnetic compatibility**|| |EMC immunityaccordingto IEC 61812-1|EN 61000-6-2| |**conducted interference**|| |● due to burst accordingto IEC 61000-4-4|2 kV network connection / 1 kV control connection| |● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV| |● due to conductor-conductor surge according to IEC<br>61000-4-5|1 kV| |**field-based interference according to IEC 61000-4-3**|10 V/m| |**electrostatic discharge according to IEC 61000-4-2**|4 kV contact discharge / 8 kV air discharge| |**Safety related data**|| |categoryaccordingto EN 954-1|none| |Electrical Safety|| |**protection class IP on the front according to IEC 60529**|IP20| |**type of insulation**|Basic insulation| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|No| |**type of electrical connection**|screw terminal| |● for auxiliaryand control circuit|screw-type terminals| |**type of connectable conductor cross-sections**|| |● solid|1x(0.2 ... 2.5 mm²)| |● finelystranded with core endprocessing|1x(0.25 ... 1.5 mm²)| |● finely stranded without core end processing|1x (0.2 ... 1.5 mm²)| Subject to change without notice © Copyright Siemens 7PV15181AJ30 Page 3/6 6/4/2026 |● for AWG cables solid|1x(24 ... 14)| |---|---| |● for AWG cables stranded|1x(24 ... 14)| |**connectable conductor cross-section**|| |● solid|0.2 ... 2.5 m²| |● finelystranded with core endprocessing|0.25 ... 1.5 m²| |● finelystranded without core endprocessing|0.2 ... 1.5 m²| |**AWG number as coded connectable conductor cross**<br>**section**|| |● solid|24 ... 14| |● stranded|24 ... 14| |**Installation/ mounting/ dimensions**<br>~~a~~|| |**mounting position**<br>~~a~~|any<br>~~a~~| |**fastening method**|snap-on fasteningon 35 mm DIN rail| |**height**|90 mm| |**width**|17.5 mm| |**depth**|66.7 mm| |**required spacing**|| |● with side-by-side mounting|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|0 mm| |— downwards|0 mm| |— at the side|0 mm| |● forgroundedparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|0 mm| |— at the side|0 mm| |— downwards|0 mm| |● for liveparts|| |— forwards|0 mm| |— backwards|0 mm| |— upwards|0 mm| |— downwards|0 mm| |— at the side|0 mm| |**Ambient conditions**<br>~~a~~|| |installation altitude at height above sea level maximum<br>~~a~~|2 000 m<br>~~a~~| |**ambient temperature**|| |● duringoperation|-25 ... +55 °C| |● duringstorage|-40 ... +70 °C| |● duringtransport<br>~~ee~~|-40 ... +70 °C<br>~~ee~~| |relative humidityduringoperation<br>~~ee~~|15 ... 85 %<br>~~ee~~| |**Approvals Certificates**|| |Environmental Product Declaration<br>● global warming potential [CO2 eq] / during manufacturing<br>1.34 kg<br>● global warming potential [CO2 eq] / during operation<br>21.2 kg<br>● global warming potential [CO2 eq] / after end of life<br>-0.156 kg<br>● global warming potential [CO2 eq] / total<br>22.4 kg<br>**Environment**<br>**General Product Approval**|| Subject to change without notice © Copyright Siemens 7PV15181AJ30 Page 4/6 6/4/2026 Confirmation Confirmation ## ~~a~~ **Further information Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=7PV1518-1AJ30 **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=7PV1518-1AJ30 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/7PV1518-1AJ30 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=7PV1518-1AJ30&lang=en **==> picture [227 x 179] intentionally omitted <==** **----- Start of picture text -----**<br> 67<br>62<br>43<br>17,5 25<br>|<br>5<br>4<br>90,5 67,5<br>**----- End of picture text -----**<br> Alle Bemassungswerte sind in Millimeter (mm) angegeben All dimensions are in millimeters (mm) Subject to change without notice © Copyright Siemens 7PV15181AJ30 Page 5/6 6/4/2026 **==> picture [393 x 357] intentionally omitted <==** **----- Start of picture text -----**<br> -K<br>last modified: 6/1/2026<br>B1 A1 15<br>2<br>6 8<br>A 1 1<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 7PV15181AJ30 Page 6/6 6/4/2026
Updated at June 6, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →