Safety Relay, 240 VAC, DPST-NO, DIN Rail, 6 A, Screw
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: PILZ
- Product type: Safety Relays
- Coil Voltage:240VAC; Contact Configuration:DPST-NO; Product Range:PNOZ X7 Series; Relay Mounting:DIN Rail; Contact Current:6A; Relay Terminals:Screw; Contact Voltage AC Nom:240V; Conta
- SVHC: No SVHC (04-Feb-2026)
- IP Rating: IP20, IP40, IP54
- Coil Voltage: 240VAC
- Product Range: -
- Relay Mounting: DIN Rail
- Contact Current: 6A
- Relay Terminals: Screw
- Contact Material: Silver Tin Oxide
- Contact Configuration: DPST-NO
- Contact Voltage AC Nom: 240V
- Contact Voltage DC Nom: 24V
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 157.17 € |
| Current stock | 10+ |
| Lead time | 30 days |
Emergency Stop Relays, Safety Gate Monitors ## **Category 2, EN 954-1** PNOZ X7 24 V DC/AC, PNOZ X7 AC **==> picture [129 x 8] intentionally omitted <==** **----- Start of picture text -----**<br> Farnell Codes ; 4439314-9326-9338<br>**----- End of picture text -----**<br> Emergency Stop Relay in accordance with VDE 0113 part 1, 11/98, EN 60204-1, 12/97 and IEC 204-1, 11/98 ## **Features** ● Single-channel operation ## **Approvals** **PNOZ X7** ● ● ● **Technical Data PNOZ X7 24 V DC/AC PNOZ X7 AC Electrical Data** Supply Voltage 24 V DC/AC 42, 48, 110, 115, 120, 230, 240 V AC Tolerance 85 ... 110 % 85 ... 110 % Power Consumption Approx. 2 W/2 VA Approx. 3 VA ~~OO~~ Voltage and Current at reset circuit/ feedback control loop 24 V DC, 50 mA 24 VDC, 50 mA Switching Capability in accordance with EN 60947-4-1, 10/91 AC1: 240 V/6 A/1500 VA 240 V/3 A/700 VA DC1: 24 V/6 A/150 W 24 V/3 A/70 W in accordance with EN 60947-5-1, 10/91 AC15: 230 V/5 A 230 V/3 A DC13: 24 V/6 A 24 V/3 A Output Contacts 2 (N/O) safety contacts Contact Fusing to EN 60947-5-1, 10/91 6 A quick or 4 A slow **Times** Response Delay Aver. 50 ms Aver. 250 ms Max. 400 ms Max. 700 ms Release Delay Max. 85 ms Max. 120 ms Recovery Time Max. 400 ms Max. 400 ms Max. Supply Interrupt before Approx. 10 ms Approx. 10 ms De-energisation **Mechanical Data** Max. cross section of 2 x 2.5 mm[2] single-core or external conductors multi-core with crimp connectors Dimensions (H x W x D) 87 x 22.5 x 122 mm ~~OO~~ Weight 190 g 240 g ## **Description** - 22.5 mm S-95 housing, DIN-Rail Mounting - Relay outputs, positive guided: – 2 (N/O) safety contacts - Connections: – e-stop button - reset button - LED indicators for status and supply voltage - Increase in the number of contacts available by connecting external contactors/relays ## **Operating Modes** - Single-channel operation - Automatic reset - Manual reset NSG-D-2-046-10/02 Emergency Stop Relays, Safety Gate Monitors ## **Category 2, EN 954-1** PNOZ X7 24 V DC/AC, PNOZ X7 AC ## **Internal Wiring Diagram** – PNOZ X7 24 V DC/AC **==> picture [415 x 121] intentionally omitted <==** **----- Start of picture text -----**<br> Y1 Y2 13 23<br>i a rna<br>A1 |y K1 in View ||<br>| |<br>| + Switch-on logic, Channel 1 |<br>| Cycle test,Control logic Channel 2 |<br>| [|]<br>| |<br>| K2 -|-\ |<br>A2 |<br>|<br>14 24<br>**----- End of picture text -----**<br> – PNOZ X7 AC **==> picture [481 x 356] intentionally omitted <==** **----- Start of picture text -----**<br> A1 A2 Y1 Y2 13 23<br>n ana n eee|<br>K1 —-y-7|<br>|<br>Switch-on logic, Channel 1 |<br>~ Cycle test, |<br>G = Control logic Channel 2 ||<br>K2 -\-\ |<br>1 |<br>= Y W _|<br>14 24<br>External Wiring ● Increase in contacts<br>If required the number of output<br>● Example 1 contacts on the PNOZ X7 can be<br>Single-channel E-Stop wiring with increased using external relays /<br>manual reset contactors.<br>UB<br>(L+) Y1 1L1<br>S1 K3 K4<br>S3<br>Y1 Y2 13<br>; ' | |<br>1----@---@-' A1 Y2 | |i<br>Lo. eee. _—.—.—.]<br>14<br>–<br>Key<br>K3 K4<br>S1: E-Stop button<br>S3: Reset button 1L2<br>**----- End of picture text -----**<br> NSG-D-2-046-10/02 Emergency Stop Relays, Safety Gate Monitors ## **Category 2, EN 954-1** PNOZ X7 24 V DC/AC, PNOZ X7 AC ## **General Technical Data** ## **Unless stated otherwise in the technical details for the specific unit** ## **Electrical Data** Frequency Range AC 50 ... 60 Hz Residual Ripple DC 160 % Contact Material AgSnO2 Continuous Duty 100 % **Environmental Data** EMC EN 50081-1, 01/92, EN 50082-2, 03/95 Vibration in accordance with Frequency: 10 ... 55 Hz, EN 60068-2-6, 04/95 Amplitude: 0.35 mm Climatic Suitability DIN IEC 60068-2-3, 12/86 Airgap Creepage DIN VDE 0110 part 1, 04/97 Ambient Temperature -10 ... +55 °C Storage Temperature -40 ... +85 °C **Mechanical Data** Torque Setting on Connection Terminals 0.6 Nm (screws) Mounting Position Any Housing Material Thermoplast Noryl SE 100 Protection Mounting: IP 54 Housing: IP 40 Terminal Range: IP 20 The units were tested in accordance with the relevant standards current at the time of development. ## **Order References** |**Type**|**UB**|**Order No.**|Farnell Code|Farnell Code|Farnell Code| |---|---|---|---|---|---| |PNOZ X7|24 V ACDC|774 059||4439314|| |PNOZ X7|42 V AC|774 058|||| |PNOZ X7|48 V AC|774 049|||| |PNOZ X7|110 V AC|774 053|||4439326| |PNOZ X7|115 V AC|774 054|||| |PNOZ X7|120 V AC|774 055|||| |PNOZ X7|230 V AC|774 056|||4439338| |PNOZ X7|240 V AC|774 057|||| NSG-D-2-046-10/02
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →