77.G1.8.230.8250
Solid State Relay, Hockey Puck Style, SPST-NO, 100 A, 280 VAC, Panel Mount, Screw, Zero Crossing
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: FINDER
- Product type:
- SVHC: No SVHC (04-Feb-2026)
- Load Current: 100A
- Product Range: 77 Series
- Relay Mounting: Panel Mount
- Switching Mode: Zero Crossing
- Relay Terminals: Screw
- Control Voltage Max: 280VAC
- Control Voltage Min: 90VAC
- Contact Configuration: SPST-NO
- Operating Voltage Max: 280VAC
- Operating Voltage Min: 24VAC
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 52.76 € |
| Current stock | 10+ |
| Lead time | 30 days |
77 SЕRIES
## Solid State Relays from 5 to 125 A
Industrial motors
Industrial furnaces and ovens
Lighting control in corridors (for hotels, offices and hospitals) Bottling plant
Labelling machines
Packaging machines
Finder reserves the right to make changes to its products and their technical specifications at any time and without prior notice, as part of its policy of continuous improvement. The information contained in this document is provided for indicative purposes only and does not constitute a contractual obligation; errors and omissions excepted. In the event of any discrepancy between the printed and online versions, the latter, available at findernet.com, shall prevail.
77 SERIES
## **5 A modular SSR, 1 NO AC output**
## **77.01.x.xxx.8050**
## **77.01.x.xxx.8051**
- 17.5 mm housing
- 60 to 240 V AC output (with back to back SCR) • 5 kV (1.2/50 µs) insulation between Input and Output
- Zero-crossing and random switch-on versions available
- High switching speed
- High endurance
- Silent switching
- Spark and bounce-free switching
## **Random switch-on**
## **Zero-crossing switch-on Suggested applications:**
- Low control power
## **Suggested applications:**
- 3-phase general purpose • 35 mm rail (EN 60715) mount
- ~~i~~
- • Lamp inrush current reduction ~~i~~ • Finer control requiring short (CFL - Compact Fluorescent ! operate time (specially motor i H energy-saving Lamps and i ! control) i ! eo i eo
- similar) • AC Input phase different from AC Input phase different from
77.01 Box clamp
- AC Input phase different from AC Input phase different from AC Output phase
- Heater control
- Solenoid, contactor driver
- See L77-8 diagram page 20 ** See L77-1 and L77-2 diagrams page 19
Simplified circuit diagram
Simplified circuit diagram
|**5 A modular SSR, 1 NO AC output**<br>• 17.5 mm housing17.5 mm housing<br>• 60 to 240 V AC output (with back to back SCR)60 to 240 V AC output (with back to back SCR)<br>• 5 kV (1.2/50 µs) insulation between Input and5 kV (1.2/50 µs) insulation between Input and<br>Output<br>• Zero-crossing and random switch-on versionsZero-crossing and random switch-on versions<br>available<br>• High switching speedHigh switching speed<br>• High enduranceHigh endurance<br>• Silent switchingSilent switching<br>• Spark and bounce-free switchingSpark and bounce-free switching<br>• Low control powerLow control power<br>• 3-phase general purpose3-phase general purpose<br>• 35 mm rail (EN 60715) mount35 mm rail (EN 60715) mount<br>77.01<br>Box clamp<br>* See L77-8 diagram page 20<br>** See L77-1 and L77-2 diagrams page 19<br>For outline drawing see page 27<br>**Output specification**<br>Output configuration|**77.01.x.xxx.8050**<br>**Zero-crossing switch-on**<br>**Suggested applications:**<br>• Lamp inrush current reductionLamp inrush current reduction<br>(CFL - Compact Fluorescent<br>energy-saving Lamps and<br>similar)<br>• Heater controlHeater control<br>• Solenoid, contactor driverSolenoid, contactor driver<br>Simplified<br>circuit diagram<br>1 NO (SPST-NO)<br>e¢<br>(Deter<br>aaa<br>ee<br>Al<br>A2<br>poe<br>~~i~~<br>~~!~~<br>~~i~~<br>l<br>i<br>i<br>!<br>i<br>!<br>eo<br>i<br>Load<br>L<br>14<br>13|**77.01.x.xxx.8050**<br>**Zero-crossing switch-on**<br>**Suggested applications:**<br>• Lamp inrush current reductionLamp inrush current reduction<br>(CFL - Compact Fluorescent<br>energy-saving Lamps and<br>similar)<br>• Heater controlHeater control<br>• Solenoid, contactor driverSolenoid, contactor driver<br>Simplified<br>circuit diagram<br>1 NO (SPST-NO)<br>e¢<br>(Deter<br>aaa<br>ee<br>Al<br>A2<br>poe<br>~~i~~<br>~~!~~<br>~~i~~<br>l<br>i<br>i<br>!<br>i<br>!<br>eo<br>i<br>Load<br>L<br>14<br>13|**77.01.x.xxx.8051**<br>**Random switch-on**<br>**Suggested applications:**<br>• Finer control requiring shortFiner control requiring short<br>operate time (specially motor<br>control)<br>• AC Input phase different from AC Input phase different fromAC Input phase different from<br>AC Output phase<br>Simplified<br>circuit diagram<br>1 NO (SPST-NO)<br>e¢<br>@nnder<br>poee<br>ee<br>Al<br>A2<br>ane<br>~~i~~<br>~~!~~<br>~~i~~<br>~~:~~<br>~~i~~<br>i<br>l<br>i<br>H<br>i<br>!<br>i<br>eo<br>1<br>Rh<br>i<br>i<br>Load<br>L<br>14<br>13|**77.01.x.xxx.8051**<br>**Random switch-on**<br>**Suggested applications:**<br>• Finer control requiring shortFiner control requiring short<br>operate time (specially motor<br>control)<br>• AC Input phase different from AC Input phase different fromAC Input phase different from<br>AC Output phase<br>Simplified<br>circuit diagram<br>1 NO (SPST-NO)<br>e¢<br>@nnder<br>poee<br>ee<br>Al<br>A2<br>ane<br>~~i~~<br>~~!~~<br>~~i~~<br>~~:~~<br>~~i~~<br>i<br>l<br>i<br>H<br>i<br>!<br>i<br>eo<br>1<br>Rh<br>i<br>i<br>Load<br>L<br>14<br>13|
|---|---|---|---|---|
|Rated current IN/Max.peak current* (10 ms)<br>A|5/300*||5/300*||
|Rated voltage<br>V AC (50/60 Hz)|230||230||
|Switchingvoltage range<br>V AC (50/60 Hz)|48…265||48…265||
|Repetitivepeak off-state voltage<br>Vpk|800||800||
|Rated load AC7a (cosφ= 0.8)<br>A|5||5||
|Rated load AC15<br>A|5||3||
|Singlephase motor rating(230 V AC)<br>kW|—||0.1||
|Nominal lamp rating:<br>230 V incandescent/halogen W<br>fluorescent tubes with<br>electronic ballast W<br>fluorescent tubes with<br>electromagnetic ballast W<br>CFL W<br>230 V LED W<br>LV halogen or LED with<br>electronic ballast W<br>LV halogen or LED with<br>electromagnetic ballast W|1000||800||
||1000||800||
||1000||800||
||800||400||
||800||400||
||800||400||
||1000||800||
|Minimum switchingcurrent @ 230 V<br>mA|100||100||
|Typical “OFF-state” leakage current @ 230 V<br>mA|0.5||3.5||
|Max “ON-state” voltage drop<br>@ 25 °C and 5 A/100 mA<br>V|0.85/1.5||0.85/1.5||
|Power loss @ 5 A<br>W<br>**Input specification**<br>Nominal voltage (UN)<br>V AC (50/60 Hz)<br>V DC|4<br>—<br>230||4<br>—<br>230||
||6…24|—|6…24|—|
|Ratedpower<br>VA (50 Hz)/W|—/0.4|3.6/0.3|—/0.4|3.6/0.3|
|Operating range<br>V AC (50/60 Hz)<br>V DC|—|90…265|—|90…265|
||4…32|—|4…32|—|
|Must drop-out voltage<br>V AC (50/60 Hz)/DC<br>**Technical data**<br>Electrical life<br>cycles|3<br>24<br>10 · 106||3<br>24<br>10 · 106||
|Operate/release time<br>ms|20/12||9/8||
|Insulation between input<br>and output(1.2/50µs)<br>kV|5||5||
|Ambient temperature<br>°C|–20…+70**||–20…+70**||
|Protection category<br>**Approvals**(according to type)|IP 20<br>IP 20<br>UK<br>C€&6We<br>EAL||||
D
**3**
77 SERIES
## **7 - 15 A modular SSR, 1 NO DC output**
**77.01.9.024.9024 77.01.9.024.9125**
- 17.5 mm housing
- 2 versions, for 24 and 125 V DC mosfet output
- 4 kV (1.2/50 µs) insulation between Input and Output
- Short circuit protection
- High switching speed
- High endurance
- Silent switching
- Spark and bounce-free switching
D
**24 V DC output switching 110…125 V DC output 15 A rated switching 7 A rated Applications in Energy, Automation and Machines: Applications in Energy,** • Control of electric, pneumatic **Automation and Machines:**
- Low control power
- Suitable for railway applications
- 35 mm rail (EN 60715) mount
## 77.01
|**7 - 15 A modular SSR, 1 NO DC output**<br>• 17.5 mm housing17.5 mm housing<br>• 2 versions, for 24 and 125 V DC mosfet output2 versions, for 24 and 125 V DC mosfet output<br>• 4 kV (1.2/50 µs) insulation between Input and4 kV (1.2/50 µs) insulation between Input and<br>Output<br>• Short circuit protectionShort circuit protection<br>• High switching speedHigh switching speed<br>• High enduranceHigh endurance<br>• Silent switchingSilent switching<br>• Spark and bounce-free switchingSpark and bounce-free switching<br>• Low control powerLow control power<br>• Suitable for railway applicationsSuitable for railway applications<br>• 35 mm rail (EN 60715) mount35 mm rail (EN 60715) mount<br>77.01<br>Box clamp<br>* See L77-3 and L77-4 diagrams page 19<br>For outline drawing see page 27<br>**Output specification**<br>Output configuration|**77.01.9.024.9024**<br>**24 V DC output switching**<br>**15 A rated**<br>**Applications in Energy,**<br>**Automation and Machines:**<br>• Control of electric, pneumaticControl of electric, pneumatic<br>and hydraulic electromagnetic<br>valves<br>•Direct control of loads such as<br>motors and electromagnets<br>Simplified<br>circuit diagram<br>1 NO (SPST-NO)<br>ee<br>xy|**77.01.9.024.9125**<br>**110…125 V DC output**<br>**switching**<br>**7 A rated**<br>**Applications in Energy,**<br>**Automation and Machines:**<br>•Control of electric, pneumatic<br>and hydraulic electromagnetic<br>valves<br>•Direct control of loads such as<br>motors and electromagnets<br>Simplified<br>circuit diagram<br>1 NO (SPST-NO)<br>ee<br>xy|
|---|---|---|
|Rated current IN/Max.peak current (10 ms)<br>A|15/160<br>~~a~~|7/60<br>~~a~~|
|Rated voltage<br>V DC|24<br>~~a~~<br>~~a~~|125<br>~~a~~<br>~~a~~|
|Switchingvoltage range<br>V DC|16…32<br>~~a~~<br>~~a~~|43…140<br>~~a~~<br>~~a~~|
|Rated load DC13<br>A|5<br>~~a~~|2.5<br>~~a~~|
|DC motor rating<br>kW|0.2<br>~~a~~<br>~~a~~|—<br>~~a~~<br>~~a~~|
|Minimum switchingcurrent<br>mA|100<br>~~a~~<br>~~a~~|50<br>~~a~~<br>~~a~~|
|Typical “OFF-state” leakage current<br>mA|3<br>~~a~~|6<br>~~a~~|
|Max “ON-state” voltage drop<br>@ 25 °C and IN<br>V|0.06<br>~~a~~|0.2<br>~~a~~|
|Power loss @ IN<br>W<br>**Input specification**<br>Nominal voltage (UN)<br>V DC|1<br>6…24|1.5<br>6…24|
|Ratedpower<br>W|0.4<br>~~a~~|0.4<br>~~a~~|
|Operatingrange<br>V DC|4…32<br>~~a~~|4…32<br>~~a~~|
|Must drop-out voltage<br>V DC<br>**Technical data**<br>Electrical life<br>cycles|3<br>10 · 106<br>~~a~~<br>~~CY~~|3<br>10 · 106<br>~~a~~<br>~~CY~~<br>~~OS~~|
|Operate/release time<br>ms|0.05/2<br>~~CY~~|0.05/2<br>~~CY~~<br>~~OS~~|
|Insulation between input<br>and output(1.2/50µs)<br>kV|4<br>~~CY~~|4<br>~~CY~~<br>~~OS~~|
|Ambient temperature<br>°C|–20…+70*<br>~~a~~|–20…+70*<br>~~a~~|
|Protection category<br>**Approvals**(according to type)|IP 20<br>IP 20<br>~~a~~<br>~~a~~<br>C€eS@sFA||
**4**
77 SERIES
D
## **15 A modular SSR, 1 NO output**
## **77.11.x.xxx.8250**
## **77.11.x.xxx.8251**
- 22.5 mm housing, heat-sink + plastic cover
- 24 to 277 V AC output (with TRIAC)
- 6 kV (1.2/50 µs) insulation between Input and Output
- Zero-crossing and random switch-on versions available
- High switching speed
- High endurance
- Silent switching
- Spark and bounce-free switching
- Low control power
- 3-phase general purpose
- “Relay-style” terminal arrangement (input and output terminals on opposite sides)
- 35 mm rail (EN 60715) mount
- 77.11 Box clamp
## **Zero-crossing switch-on Suggested applications:**
## **Random switch-on**
## **Suggested applications:**
- Lamp inrush current reduction • Fine controls involving shorter (CFL - Compact Fluorescent i! time (specially motor control) energy-saving Lamps and i! i ! i wo i we!
- similar)
- Heater control
- Solenoid, contactor driver
* See L77-9 diagram page 20
- ** See L77-5 diagrams page 19
For outline drawing see page 27
Simplified Simplified circuit diagram circuit diagram
## **Output specification**
||Output configuration|1 NO (SPST-NO)|1 NO (SPST-NO)|||1 NO (SPST-NO)|1 NO (SPST-NO)|
|---|---|---|---|---|---|---|---|
||Rated current IN/Max.peak current* (10 ms)<br>A|15/400*||||15/400*||
||Rated voltage<br>V AC (50/60 Hz)|230||||230||
||Switchingvoltage range<br>V AC (50/60 Hz)|19…305||||19…305||
||Repetitivepeak off-state voltage<br>Vpk|800||||800||
||Rated load AC7a (cosφ= 0.8, @ 25 °C)<br>A|20||||20||
||Rated load AC15<br>A|15||||15||
||Singlephase motor rating(230 V AC)<br>kW|—||||0.75||
||Nominal lamp rating:<br>230 V incandescent/halogen W|4000||||2500||
||fluorescent tubes with<br>electronic ballast W|4000||||2500||
||fluorescent tubes with<br>electromagnetic ballast W|2000||||1000||
||CFL W|3000||||1500||
||230 V LED W|3000||||1500||
||LV halogen or LED with<br>electronic ballast W|3000||||1500||
||LV halogen or LED with<br>electromagnetic ballast W|3000||||1500||
||Minimum switchingcurrent @ 250 V<br>mA|100||||100||
||Typical “OFF-state” leakage current @ 250 V<br>mA|1||||1||
||Max “ON-state” voltage drop<br>@ 25 °C and 15 A<br>V|1.55||||1.55||
||Power loss @ 15 A<br>W<br>**Input specification**|14||||14||
||Nominal voltage (UN)<br>V AC (50/60 Hz)|—|230|||—|230|
||V DC|24|—|||24|—|
||Ratedpower<br>VA (50 Hz)/W|0.4|7.5/0.9|||0.4|7.5/0.9|
||Operating range<br>V AC (50/60 Hz)|—|40…280|||—|40…280|
||V DC|4…32|—|||4…32|—|
||Must drop-out voltage<br>V AC (50/60 Hz)/DC|—/2|6/—|||—/2|6/—|
||**Technical data**|||||||
||Electrical life<br>cycles|10 · 106||||10 · 106||
|V-2026, www.findernet.com|Operate/release time<br>ms<br>Insulation between input<br>and output(1.2/50µs)<br>kV<br>Ambient temperature<br>°C<br>Protection category<br>**Approvals**(according to type)|< 10/< 10<br>< 10/< 30<br>6<br>–20…+80**<br>IP 20||UK<br>cA|cQvVis|< 1/< 10<br>< 2/< 25<br>6<br>–20…+80**<br>IP 20||
**5**
77 SERIES
## **25 A modular SSR, 1 NO output**
## **77.21.x.xxx.8250**
**==> picture [77 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
77.21.x.xxx.8251<br>**----- End of picture text -----**<br>
- 22.5 mm housing, heat-sink + plastic cover
- 24 to 277 V AC output (with TRIAC)
- 6 kV (1.2/50 µs) insulation between Input and Output
- Zero-crossing and random switch-on versions available
- High switching speed
- High endurance
- Silent switching
- Spark and bounce-free switching
- Low control power
- 3-phase general purpose
- “Relay-style” terminal arrangement (input and output terminals on opposite sides)
- 35 mm rail (EN 60715) mount
77.21 Box clamp
## **Zero-crossing switch-on**
**Random switch-on**
## **Suggested applications:**
> **Suggested applications:** ~~i~~ **Suggested applications:** ~~i~~ i i
> Lamp inrush current reduction ~~i~~ • Finer control requiring short (CFL - Compact Fluorescent ii operate time i i energy-saving Lamps and ii ei (specially motor control) ii ai similar) , i , I
- Lamp inrush current reduction
- Heater control
- Solenoid, contactor driver
D
* See L77-10 diagram page 20
** See L77-6 diagrams page 19
For outline drawing see page 27
Simplified Simplified circuit diagram circuit diagram
## **Output specification**
Output configuration
|Output configurationput configurationut configurationgurationuration|1 NO (SPST-NO)|1 NO (SPST-NO)|1 NO (SPST-NO)|1 NO (SPST-NO)|
|---|---|---|---|---|
|Rated current (@40 °C) IN/<br>Max.peak current*(10 ms)<br>A|25/400*||25/400*||
|Rated voltage<br>V AC (50/60 Hz)|230||230||
|Switchingvoltage range<br>V AC (50/60 Hz)|19…305||19…305||
|Repetitivepeak off-state voltage<br>Vpk|800||800||
|Rated load AC7a (cosφ= 0.8, @ 25 °C)<br>A|25||25||
|Rated load AC15<br>A|25||25||
|Singlephase motor rating(230 V AC)<br>kW|—||1||
|Nominal lamp rating:<br>230 V incandescent/halogen W|4000||2500||
|fluorescent tubes with<br>electronic ballast W|4000||2500||
|fluorescent tubes with<br>electromagnetic ballast W|2000||1000||
|CFL W|3000||1500||
|230 V LED W|3000||1500||
|LV halogen or LED with<br>electronic ballast W|3000||1500||
|LV halogen or LED with<br>electromagnetic ballast W|3000||1500||
|Minimum switchingcurrent @ 250 V<br>mA|100||100||
|Typical “OFF-state” leakage current @ 250 V<br>mA|1||1||
|Max “ON-state” voltage drop<br>@ 25 °C and 25 A<br>V|1.55||1.55||
|Power loss @ 25 A<br>W<br>**Input specification**|14||14||
|Nominal voltage (UN)<br>V AC (50/60 Hz)|—|230|—|230|
|V DC|24|—|24|—|
|Ratedpower @ UMAX<br>VA (50 Hz)/W|0.4|7.5/0.9|0.4|7.5/0.9|
|Operating range<br>V AC (50/60 Hz)|—|40…280|—|40…280|
|V DC|4…32|—|4…32|—|
|Must drop-out voltage<br>V AC (50/60 Hz)/DC|—/2|6/—|—/2|6/—|
|**Technical data**|||||
|Electrical life<br>cycles|10 · 106||10 · 106||
|Operate/release time<br>ms<br>Insulation between input<br>and output(1.2/50µs)<br>kV<br>Ambient temperature<br>°C<br>Protection category<br>**Approvals**(according to type)|< 10/< 10<br>< 10/< 30<br>6<br>–20…+80**<br>IP 20<br>Cé||< 1/< 10<br>< 2/< 25<br>6<br>–20…+80**<br>IP 20<br>UK<br>cA||
**6**
77 SERIES
## **30 A modular SSR, 1 NO output**
## **77.31.x.xxx.8050**
## **77.31.x.xxx.8051**
- 22.5 mm housing, heat-sink + plastic cover
- 60 to 440 V AC output (with back to back SCR)
- 6 kV (1.2/50 µs) insulation between Input and Output
- Zero-crossing and random switch-on versions available
- High switching speed
- High endurance
- Silent switching
- Spark and bounce-free switching
- Low control power
- 3-phase general purpose
- “Relay-style” terminal arrangement (input and output terminals on opposite sides)
- 35 mm rail (EN 60715) mount
77.31 Box clamp
## **Zero-crossing switch-on Suggested applications:**
- Lamp inrush current reduction (CFL - Compact Fluorescent energy-saving Lamps and similar)
- Heater control
## **Random switch-on**
## **Suggested applications:**
- Finer control requiring short operate time (specially motor control)
- Solenoid, contactor driver
D
* See L77-11 diagram page 20
** See L77-7 diagrams page 19
For outline drawing see page 27
Simplified Simplified circuit diagram circuit diagram
**Output specification**
||Output configuration|1 NO (SPST-NO)|1 NO (SPST-NO)|||1 NO (SPST-NO)|1 NO (SPST-NO)|
|---|---|---|---|---|---|---|---|
||Rated current IN/Max.peak current* (10 ms)<br>A|30/520*||||30/520*||
||Rated voltage<br>V AC (50/60 Hz)|400||||400||
||Switchingvoltage range<br>V AC (50/60 Hz)|48…480||||48…480||
||Repetitivepeak off-state voltage<br>Vpk|1100||||1100||
||Rated load AC7a (cosφ= 0.8)<br>A|30||||30||
||Rated load AC15<br>A|20||||20||
||Singlephase motor rating(230 V AC)<br>kW|—||||1.5||
||Nominal lamp rating:<br>230 V incandescent/halogen W|6000||||4500||
||fluorescent tubes with<br>electronic ballast W|6000||||4000||
||fluorescent tubes with<br>electromagnetic ballast W|3000||||1800||
||CFL W|4000||||2500||
||230 V LED W|4000||||2500||
||LV halogen or LED with<br>electronic ballast W|4000||||2500||
||LV halogen or LED with<br>electromagnetic ballast W|4000||||2500||
||Minimum switchingcurrent @ 400 V<br>mA|300||||300||
||Typical “OFF-state” leakage current @ 400 V<br>mA|1||||1||
||Max “ON-state” voltage drop<br>@ 25 °C and 30 A<br>V|0.85||||0.85||
||Power loss @ 30 A<br>W<br>**Input specification**|16||||16||
||Nominal voltage (UN)<br>V AC (50/60 Hz)|24|230|||—|230|
||V DC|24|—|||24|—|
||Ratedpower @ UMAX<br>VA (50 Hz)/W|0.24/0.4|7.5/0.9|||0.4|7.5/0.9|
||Operating range<br>V AC (50/60 Hz)|—|40…280|||—|40…280|
||V DC|4…32|—|||4…32|—|
||Must drop-out voltage<br>V AC (50/60 Hz)/DC|6/2|6/—|||—/2|6/—|
||**Technical data**|||||||
||Electrical life<br>cycles|10 · 106||||10 · 106||
|V-2026, www.findernet.com|Operate/release time<br>ms<br>Insulation between input<br>and output(1.2/50µs)<br>kV<br>Ambient temperature<br>°C<br>Protection category<br>**Approvals**(according to type)|< 10/< 10<br>< 10/< 30<br>6<br>–20…+80**<br>IP 20<br>~~oe~~<br>CE||~~UK~~<br> cS|We|< 1/< 10<br>< 2/< 25<br>6<br>–20…+80**<br>IP 20<br>FAL||
**7**
77 SERIES
## **30 A modular SSR, 1 NO output**
## **77.31.x.xxx.8070**
**==> picture [77 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
77.31.x.xxx.8071<br>**----- End of picture text -----**<br>
- 22.5 mm housing, heat-sink + plastic cover
- 60 to 440 V AC output (with back to back SCR)
- 6 kV (1.2/50 µs) insulation between Input and Output
- Zero-crossing and random switch-on versions available
- High switching speed
- High endurance
- Silent switching
- Spark and bounce-free switching
- Low control power
- 3-phase general purpose
- “Contactor-style” terminal arrangement (input and output terminals on adjacent sides)
- 35 mm rail (EN 60715) mount
77.31 Box clamp
## **Zero-crossing switch-on**
## **Suggested applications:**
- Lamp inrush current reduction
- (CFL - Compact Fluorescent energy-saving Lamps and similar)
- Heater control
## **Random switch-on Suggested applications:**
- Fine controls involving shorter
- i time (specially motor control) ;
- Solenoid, contactor driver
D
- See L77-11 diagram page 20
- ** See L77-7 diagrams page 19
For outline drawing see page 27
Simplified Simplified circuit diagram circuit diagram
## **Output specification**
|Output configuration|1 NO (SPST-NO)|1 NO (SPST-NO)|||1 NO (SPST-NO)|1 NO (SPST-NO)|
|---|---|---|---|---|---|---|
|Rated current IN/Max.peak current* (10 ms)<br>A|30/520*||||30/520*||
|Rated voltage<br>V AC (50/60 Hz)|400||||400||
|Switchingvoltage range<br>V AC (50/60 Hz)|48…480||||48…480||
|Repetitivepeak off-state voltage<br>Vpk|1100||||1100||
|Rated load AC7a (cosφ= 0.8)<br>A|30||||30||
|Rated load AC15<br>A|20||||20||
|Singlephase motor rating(230 V AC)<br>kW|—||||1.5||
|Nominal lamp rating:<br>230 V incandescent/halogen W|6000||||4500||
|fluorescent tubes with<br>electronic ballast W|6000||||4000||
|fluorescent tubes with<br>electromagnetic ballast W|3000||||1800||
|CFL W|4000||||2500||
|230 V LED W|4000||||2500||
|LV halogen or LED with<br>electronic ballast W|4000||||2500||
|LV halogen or LED with<br>electromagnetic ballast W|4000||||2500||
|Minimum switchingcurrent @ 400 V<br>mA|300||||300||
|Typical “OFF-state” leakage current @ 400 V<br>mA|1||||1||
|Max “ON-state” voltage drop<br>@ 25 °C and 30 A<br>V|0.85||||0.85||
|Power loss @ 30 A<br>W<br>**Input specification**|16||||16||
|Nominal voltage (UN)<br>V AC (50/60 Hz)|—|230|||—|230|
|V DC|24|—|||24|—|
|Ratedpower<br>VA (50 Hz)/W|0.4|7.5/0.9|||0.4|7.5/0.9|
|Operating range<br>V AC (50/60 Hz)|—|40…280|||—|40…280|
|V DC|4…32|—|||4…32|—|
|Must drop-out voltage<br>V AC (50/60 Hz)/DC|—/2|6/—|||—/2|6/—|
|**Technical data**|||||||
|Electrical life<br>cycles|10 · 106||||10 · 106||
|Operate/release time<br>ms<br>Insulation between input<br>and output(1.2/50µs)<br>kV<br>Ambient temperature<br>°C<br>Protection category<br>**Approvals**(according to type)|< 10/< 10<br>< 10/< 30<br>6<br>–20…+80**<br>IP 20<br>CE||UK<br>&§|@«|< 1/< 10<br>< 2/< 25<br>6<br>–20…+80**<br>IP 20<br>FAL||
**8**
77 SERIES
D
**25, 40 and 60 A panel Zero-crossing SSR, “hockey puck” style**
**77.A1.x.xxx.8x50 77.B1.x.xxx.8x50**
## **77.D1.x.xxx.8x50**
**Type 77.A1.x.xxx.8x50:** 25 A **Type 77.B1.x.xxx.8x50:** 40 A
**Type 77.D1.x.xxx.8x50:** 60 A
- **8250:** 24 to 280 VAC switching load voltage
- **8650:** 24 to 660 VAC switching load voltage
- “hockey puck” housing with folding screw cover
- High endurance and switching speed
- Silent switching
- Spark and bounce-free switching
- Low control power
- “Relay-style”: input and output terminals on opposite sides
**Zero-crossing switch-on**
- Output: 25 A
- Suggested applications: heater control, lamps, solenoid, contactor driver
**Zero-crossing switch-on**
## **Zero-crossing switch-on**
- Output: 40 A
- Output: 60 A
- Suggested applications: • Suggested applications: heater control, lamps, heater control, lamps, solenoid, contactor driver solenoid, contactor driver
- Mounting on control cabinet sheet metal or on heatsink
77.A1/B1/D1
Screw terminal (plate clamp)*
* See recommendation for wiring page 17
- ** See L77-13, L77-14 and L77-15 diagrams page 21
||**See L77-13, L77-14 and L77-15 diagrams page 21|iowan|iowan|6es|es-|es-|es-|1-6es-|1-6es-|
|---|---|---|---|---|---|---|---|---|---|
||Four outline drawing see page 27|Simplified circuit diagram||Simplified circuit diagram|Simplified circuit diagram|||Simplified circuit diagram||
||**Output specification**|**77…8250**|**77…8650**|**77…8250**|||**77…8650**|**77…8250**|**77…8650**|
||Output configuration|1 NO|||1 NO|||1 NO||
||Rated current IN/Max.peak current (10 ms)<br>A|25/300||40/500||||60/700||
||Rated voltage<br>V AC (50/60 Hz)|240|600|240|||600|240|600|
||Switchingvoltage range<br>V AC (50/60 Hz)|24…280|24…660|24…280|||24…660|24…280|24…660|
||Operatingfrequencyrange<br>Hz|47…400|47…400|47…400|||47…400|47…400|47…400|
||Repetitivepeak off-state voltage<br>Vpk|600|1600|600|||1600|600|1600|
||Rated load AC53<br>A|50|||8|||12||
||Nominal lamp rating:<br>230 V incandescent/halogen W|2000|||4000|||7200||
||fluorescent tubes with electronic ballast W|2000|||4000|||7200||
||fluorescent tubes with electromagnetic ballast W|1000|||2000|||3600||
||CFL W|800|||3000|||4800||
||230 V LED W|800|||3000|||4800||
||LV halogen or LED with electronic ballast W|800|||3000|||4800||
||LV halogen or LED with electromagnetic ballast W|1000|||3000|||4800||
||Minimum switchingcurrent @ 250 V<br>mA|100|||100|||100||
||Typical “OFF-state” leakage current<br>@ rated voltage<br>mA|0.1|||0.1|||0.1||
||Max “ON-state” voltage<br>drop @25 °C and IN<br>V|1.5|||1.5|||1.5||
||Power loss @ IN<br>W<br>**Input specification**|30|||48|||72||
||Nominal voltage (UN)<br>V AC (50/60 Hz)|—|230|—|||230|—|230|
||V DC|24|—|24|||—|24|—|
||Ratedpower @ UMAX<br>VA (50 Hz)/W|—/0.55|5.3/—|—/0.55|||5.3/—|—/0.55|5.3/—|
||Operating range<br>V AC (50/60 Hz)|—|90…280|—|||90…280|—|90…280|
||V DC|3…32|—|3…32|||—|3…32|—|
||Must drop-out voltage<br>V AC (50/60 Hz)/DC|—/1|15/—|—/1|||15/—|—/1|15/—|
||**Technical data**|||||||||
||Electrical life<br>cycles|—|||—|||—||
|V-2026, www.findernet.com|Operate/release time<br>ms<br>Insulation between input<br>and output(1.2/50µs)<br>kV<br>Ambient temperature<br>°C<br>Protection category<br>**Approvals**(according to type)|10/10<br>40/20<br>—<br>–30…+80**<br>IP 20||10/10<br>40/20<br>—<br>–30…+80**<br>IP 20<br>C€ YS EAL AN||||10/10<br>40/20<br>—<br>–30…+80**<br>IP 20||
**9**
77 SERIES
## **80, 100 and 125 A panel Zero-crossing SSR, “hockey puck” style**
## **77.F1.x.xxx.8x50**
## **77.G1.x.xxx.8x50**
## **77.H1.x.xxx.8x50**
**Type 77.F1.x.xxx.8x50:** 80 A **Type 77.G1.x.xxx.8x50:** 100 A **Type 77.H1.x.xxx.8x50:** 125 A
- **8250:** 24 to 280 VAC switching load voltage
- **8650:** 24 to 660 VAC switching load voltage
- “hockey puck” housing with folding screw cover
- High endurance and switching speed
- Silent switching
- Spark and bounce-free switching
- Low control power
## **Zero-crossing switch-on**
## **Zero-crossing switch-on**
- Output: 80 A
- Output: 100 A
- Suggested applications: • Suggested applications: heater control, lamps, heater control, lamps, solenoid, contactor driver solenoid, contactor driver
## **Zero-crossing switch-on**
- Output: 125 A
- Suggested applications: heater control, lamps, solenoid, contactor driver
- “Relay-style”: input and output terminals on opposite sides
- Mounting on control cabinet sheet metal or on heatsink
- D
77.F1/G1/H1
Screw terminal (plate clamp)*
* See recommendation for wiring page 17
** See L77-16, L77-17 and L77-18 diagrams page 21
For outline drawing see page 27
Simplified circuit diagram
Simplified circuit diagram
Simplified circuit diagram
||||||||
|---|---|---|---|
|**Output specification**|**77…8250**<br>**77…8650**<br>||**77…8250**<br>**77…8650**<br>||**77…8250**<br>**77…8650**<br>||
|Output configuration|1 NO<br>||1 NO<br>||1 NO<br>||
|Rated current IN/Max.peak current (10 ms)<br>A<br>80/800<br>100/1500<br>125/2250<br>Rated voltage<br>V AC (50/60 Hz)<br>240<br>600<br>240<br>600<br>240<br>600<br>Switchingvoltage range<br>V AC (50/60 Hz)<br>24…280<br>24…660<br>24…280<br>24…660<br>24…280<br>24…660<br>Operatingfrequencyrange<br>Hz<br>47…400<br>47…400<br>47…400<br>47…400<br>47…400<br>47…400<br>Repetitivepeak off-state voltage<br>Vpk<br>600<br>1600<br>600<br>1600<br>600<br>1600<br>Rated load AC53<br>A<br>16<br>20<br>25<br>~~es~~<br>~~es es~~<br>~~es es~~<br>~~sD~~<br>~~es~~<br>~~es~~||||
|Minimum switchingcurrent @ 250 V|current @ 250 V<br>mA<br>100<br>~~a~~|100|100|
|Typical “OFF-state” leakage current<br>@ rated voltage<br>mA<br>0.1||0.1|0.1|
|Max “ON-state” voltage<br>drop@ 25 °C and IN|V<br>1.5|1.5|1.5|
|Power loss @ IN<br>**Input specification**|W<br>96|120|150|
|Nominal voltage (UN)<br>Ratedpower @ UMAX<br>Operating range|V AC (50/60 Hz)<br>—<br>230<br>V DC<br>24<br>—<br>VA (50 Hz)/W<br>—/0.55<br>5.3/—<br>V AC (50/60 Hz)<br>—<br>90…280<br>V DC<br>3…32<br>—<br>~~es~~<br>~~es es~~<br>~~po~~|—<br>230<br>24<br>—<br>—/0.55<br>5.3/—<br>—<br>90…280<br>3…32<br>—|—<br>230<br>24<br>—<br>—/0.55<br>5.3/—<br>—<br>90…280<br>3…32<br>—|
|Must drop-out voltage|V AC (50/60 Hz)/DC<br>—/1<br>15/—|—/1<br>15/—|—/1<br>15/—|
|**Technical data**||||
|Electrical life|cycles<br>—|—|—|
|Operate/release time<br>ms<br>10/10<br>40/20<br>Insulation between input<br>and output(1.2/50µs)<br>kV<br>—<br>Ambient temperature<br>°C<br>–30…+80**<br>Protection category<br>—<br>**Approvals**(according to type)||10/10<br>40/20<br>—<br>–30….+80**<br>—<br>C€cSEALCAMs|10/10<br>40/20<br>—<br>–30…+80**<br>—|
**10**
77 SERIES
D
## **25, 50 and 75 A dual phase Random SSR, “hockey puck” style with 2 independent channels**
**77.A2.9.024.8671 77.C2.9.024.8671**
## **77.E2.9.024.8671**
**Type 77.A2.9.024.8671:** 25 A - 600 V AC
**Type 77.C2.9.024.8671:** 50 A - 600 V AC
**Type 77.E2.9.024.8671:** 75 A - 600 V AC
- 2 independent output channel driven by independent low power DC input
- “hockey puck” housing with folding screw cover
- High endurance and switching speed
- Silent switching
## **Random switch-on**
## **Random switch-on**
## **Random switch-on**
- Output: 25 A/600 V AC
- Output: 50 A/600 V AC
- Output: 75 A/600 V AC
- Suggested applications: • Suggested applications: • Suggested applications: heater or motor control heater or motor control heater or motor control
- Spark and bounce-free switching
- “contactor-style”: input and output terminals on adjacent sides
- Mounting on control cabinet sheet metal or on heatsink
## 77.A2/C2/E2
Screw terminal (plate clamp)*
* See recommendation for wiring page 17
** See L77-19, L77-20 and L77-21 diagrams page 22
||For outline drawing see page 27|Simplified circuit diagram|
|---|---|---|
||**Output specification**<br>Output configuration|2 NO<br>2 NO<br>2 NO|
||Rated current IN/Max.peak current (10 ms)<br>A|25/300<br>50/500<br>75/750<br>~~a~~|
||Rated voltage<br>V AC (50/60 Hz)<br>Switchingvoltage range<br>V AC (50/60 Hz)<br>Operatingfrequencyrange<br>Hz|600<br>600<br>600<br>24…660<br>24…660<br>24…660<br>47…400<br>47…400<br>47…400<br>~~OO~~<br>~~a~~<br>~~a~~|
||Repetitivepeak off-state voltage<br>Vpk|1200<br>1200<br>1200<br>~~a~~|
||Rated load AC53<br>A|5<br>10<br>15<br>~~OO~~|
||Minimum switchingcurrent @ 600 V<br>mA|—<br>—<br>—<br>~~Oe~~|
||Typical “OFF-state” leakage current<br>@ rated voltage<br>mA|5<br>5<br>5|
||Max “ON-state” voltage<br>drop@ 25 °C and IN<br>V|1.5<br>1.5<br>1.5|
||Power loss @ IN<br>W<br>**Input specification**<br>Nominal voltage (UN)<br>V DC|60<br>120<br>180<br>24<br>24<br>24|
||Ratedpower @ UMAX<br>W|0.3<br>0.3<br>0.3<br>~~a~~|
||Operatingrange<br>V DC|4…32<br>4…32<br>4…32<br>~~OO~~|
||Must drop-out voltage<br>V AC (50/60 Hz)/DC<br>**Technical data**|1<br>1<br>1|
||Electrical life<br>cycles|—<br>—<br>—|
|V-2026, www.findernet.com|Operate/release time<br>ms<br>Insulation between input<br>and output(1.2/50µs)<br>kV<br>Ambient temperature<br>°C<br>Protection category<br>**Approvals**(according to type)|1/10<br>1/10<br>1/10<br>—<br>—<br>—<br>–30…+80**<br>–30…+80**<br>–30…+80**<br>—<br>—<br>—<br>~~a~~<br>~~O™~tOOOCCCdNSN~~<br>~~SY~~<br>~~a~~<br>Cé YS FAL cAdus|
**11**
77 SERIES
## **25 and 40 A three phase Random SSR,**
## **“hockey puck” style**
**Type 77.A3.x.xxx.8671:** 25 A - 600 V AC
**Type 77.B3.x.xxx.8671:** 40 A - 600 V AC
- High endurance and switching speed
- Silent switching
- Spark and bounce-free switching
- Low control power
- “contactor-style”: input and output terminals on adjacent sides
- Mounting on control cabinet sheet metal or on heatsink
**==> picture [206 x 108] intentionally omitted <==**
**----- Start of picture text -----**<br>
77.A3.x.xxx.8671 77.B3.x.xxx.8671<br>Random switch-on Random switch-on<br>**----- End of picture text -----**<br>
- Output: 25 A/600 V AC • Output: 40 A/600 V AC
- Suggested applications: • Suggested applications: heater or motor control heater or motor control
77.A3/B3
Screw terminal (plate clamp)*
D ,
* See recommendation for wiring page 17
** See L77-22 and L77-23 diagrams page 22
|For outline drawing see page 27|For outline drawing see page 27||Simplified circuit diagram|Simplified circuit diagram||
|---|---|---|---|---|---|
|**Output specification**<br>Output configuration||3 NO||3 NO||
|Rated current IN/Max.peak current (10 ms)<br>A||25/300||40/500||
|Rated voltage|V AC (50/60 Hz)|600||600||
|Switchingvoltage range|V AC (50/60 Hz)|24…660||24…660||
|Operatingfrequencyrange|Hz|47…400||47…400||
|Repetitivepeak off-state voltage<br>Vpk||1600||1600||
|Rated load AC53|A|5||8||
|Minimum switchingcurrent @ 600 V<br>mA||—||—||
|Typical “OFF-state” leakage current<br>@ rated voltage<br>mA||10||10||
|Max “ON-state” voltage<br>drop@ 25 °C and IN|V|1.6||1.6||
|Power loss @ IN<br>**Input specification**|W|90||144||
|Nominal voltage (UN)|V AC (50/60 Hz)|—|230|—|230|
||V DC|24|—|24|—|
|Ratedpower @ UMAX|VA (50 Hz)/W|—/0.55|5.3/—|—/0.55|5.3/—|
|Operating range|V AC (50/60 Hz)|—|90…280|—|90…280|
||V DC|4…32|—|4…32|—|
|Must drop-out voltage|V AC (50/60 Hz)/DC|1|15|1|15|
|**Technical data**||||||
|Electrical life|cycles|—||—||
|Operate/release time|ms|1|10/20|1|10/20|
|Insulation between input||||||
|and output(1.2/50µs)|kV|—||—||
|Ambient temperature|°C|–30…+80**||–30…+80**||
|Protection category||—||—||
|**Approvals**(according to type)|||C€YSFAL|FALSANs||
**12**
77 SERIES
D
**60 and 80 A three phase Random SSR, “hockey puck” style Type 77.D3.x.xxx.8671:** 60 A - 600 V AC **Type 77.F3.x.xxx.8671:** 80 A - 600 V AC
- High endurance and switching speed
- Silent switching
- Spark and bounce-free switching
- Low control power
- “contactor-style”: input and output terminals on adjacent sides
- Mounting on control cabinet sheet metal or on heatsink
**==> picture [205 x 140] intentionally omitted <==**
**----- Start of picture text -----**<br>
77.D3.x.xxx.8671 77.F3.x.xxx.8671<br>Random switch-on Random switch-on<br>• Output: 60 A/600 V AC • Output: 80 A/600 V AC<br>• Suggested applications: • Suggested applications:<br>heater or motor control heater control<br>**----- End of picture text -----**<br>
77.D3/F3
Screw terminal (plate clamp)*
- See recommendation for wiring page 17
** See L77-24 and L77-25 diagrams page 22
||For outline drawing see page 27|Simplified circuit diagram|
|---|---|---|
||**Output specification**<br>Output configuration|3 NO<br>3 NO|
||Rated current IN/Max.peak current (10 ms)<br>A|60/700<br>80/1280<br>~~es~~|
||Rated voltage<br>V AC (50/60 Hz)<br>Switchingvoltage range<br>V AC (50/60 Hz)<br>Operatingfrequencyrange<br>Hz<br>Repetitivepeak off-state voltage<br>Vpk|600<br>600<br>24…660<br>24…660<br>47…400<br>47…400<br>1600<br>1600<br>~~ee~~<br>~~ee~~<br>~~es~~<br>~~es~~|
||Rated load AC53<br>A|12<br>16<br>~~es~~|
||Minimum switchingcurrent @ 600 V<br>mA|—<br>—<br>~~es~~|
||Typical “OFF-state” leakage current @ 600 V<br>mA|10<br>10<br>~~ed~~|
||Max “ON-state” voltage<br>drop@ 25 °C and IN<br>V|1.6<br>1.6|
||Power loss @ IN<br>W<br>**Input specification**|216<br>288|
||Nominal voltage (UN)<br>V AC (50/60 Hz)<br>V DC<br>Ratedpower @ UMAX<br>VA (50 Hz)/W<br>Operating range<br>V AC (50/60 Hz)<br>V DC<br>Must drop-out voltage<br>V AC (50/60 Hz)/DC|—<br>230<br>—<br>230<br>24<br>—<br>24<br>—<br>—/0.55<br>5.3/—<br>—/0.55<br>5.3/—<br>—<br>90…280<br>—<br>90…280<br>4…32<br>—<br>4…32<br>—<br>1<br>15<br>1<br>15<br>~~ee ee~~<br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~<br>~~es~~<br>~~ed~~|
||**Technical data**||
||Electrical life<br>cycles|—<br>—|
|V-2026, www.findernet.com|Operate/release time<br>ms<br>Insulation between input<br>and output(1.2/50µs)<br>kV<br>Ambient temperature<br>°C<br>Protection category<br>**Approvals**(according to type)|1<br>10/20<br>1<br>10/20<br>—<br>—<br>–30…+80**<br>–30…+80**<br>—<br>—<br>~~ee ee~~<br>~~es~~<br>~~ee~~<br>Cé PK EAL Adis|
**13**
77 77 SERIES SERIES Hockey puck SSR heat sink compatibility chart es **Hockey puck SSR heat sink compatibility chart**
**==> picture [531 x 658] intentionally omitted <==**
**----- Start of picture text -----**<br>
Heat sink SSR relay Thermal pad K/W Product Description<br>077.T1<br>077.21<br>77.A1 2.1 Heat sink SSR 1 phase<br>077.T2 - Adhesive<br>077.13<br>077.T1<br>ANEW<br>=<br>77.A1<br>D 77.B1 077.T2 - Adhesive 1.3 Heat sink SSR 1 phase<br>iv<br>077.T1<br>077.08<br>NEW<br>077.T2 - Adhesive<br>- : y;<br>77.B1 - D1 - F1 - G1 - H1<br>77.A2 - C2 - E2 0.8 Heat sink SSR 1, 2, 3 phases<br>77.A3 - B3<br>077.T3<br>BI 4<br>077.T1<br>077.03.9.024<br>NEW<br>an<br>077.T2 - Adhesive<br>77.D1 - F1 - G1 - H1 Heat sink with 24 V DC - 5.5 W<br>77.A2 - C2 - E2 0.35 cooling fan<br>77.A3 - B3 - D3 - F3 Suitable for SSR 1, 2, 3 phases<br>077.T3<br>077.T1<br>077.03.8.230<br>NEW<br>a<br>077.T2 - Adhesive<br>77.D1 - F1 - G1 - H1 Heat sink with 230 V AC - 14.5 W<br>77.A2 - C2 - E2 0.35 cooling fan<br>77.A3 - B3 - D3 - F3 Suitable for SSR 1, 2, 3 phases<br>077.T3<br>**----- End of picture text -----**<br>
**14**
77 SERIES
D
**==> picture [298 x 508] intentionally omitted <==**
**----- Start of picture text -----**<br>
1 1 Type<br>77.x1<br>77.x2<br>SSE e<br>2 2 Thermal Pad<br>Se @<br>077.T1<br>077.T2<br><><br>1 1 Type<br>77.A3<br>77.B3<br>77.D3<br>77.F3<br>2 2 Thermal Pad<br>@<br>3 077.T3<br>**----- End of picture text -----**<br>
**15**
77 SERIES
## **Ordering information - Modular SSRs**
Example: 77 Series modular SSR, 1 output 30 A AC, input voltage 230 V AC, relay style terminal arrangement, zero-crossing switch-on.
D
**A B C D 7 7 . 3 1 . 8 . 2 3 0 . 8 0 5 0 Series D: Switch-on mode Type/rated current** 0 = 5/7/15 A output (77.01) 1 = 15 A output (77.11) **C: Terminal arrangement** 2 = 25 A output (77.21) 3 = 30 A output (77.31) **No. of poles/mounting** 1 = 1 pole, modular housing (plastic or heat sink/plastic), DIN rail mounting
## **D: Switch-on mode**
0 = Zero-crossing
1 = Random
## **C: Terminal arrangement**
- 5 = “Relay style” (input and output on opposite sides)
- 7 = “Contactor style” (input and output on adjacent sides)
**AB: Output circuit**
(rated voltage)
## **Input version**
80 = 230 V AC (77.01), 400 V AC (77.31) 82 = 230 V AC (77.11, 77.21) 9024 = 24 V DC 9125 = 110…125 V DC
8 = AC (50/60 Hz)
9 = DC
**Supply voltage** See “input specification”
## **Codes/Module width**
77.01.8.230.8050/17.5 mm 5 A 77.11.8.230.8250/22.5 mm 15 A 77.21.8.230.8250/22.5 mm 25 A 77.01.9.024.8050/17.5 mm 5 A 77.11.9.024.8250/22.5 mm 15 A 77.21.9.024.8250/22.5 mm 25 A 77.01.8.230.8051/17.5 mm 5 A 77.11.8.230.8251/22.5 mm 15 A 77.21.8.230.8251/22.5 mm 25 A 77.01.9.024.8051/17.5 mm 5 A 77.11.9.024.8251/22.5 mm 15 A 77.21.9.024.8251/22.5 mm 25 A 77.01.9.024.9125/17.5 mm 7 A 77.01.9.024.9024/17.5 mm 15 A
77.31.8.024.8050/22.5 mm 30 A 77.31.8.230.8050/22.5 mm 30 A 77.31.9.024.8050/22.5 mm 30 A 77.31.8.230.8051/22.5 mm 30 A 77.31.9.024.8051/22.5 mm 30 A 77.31.8.230.8070/22.5 mm 30 A 77.31.9.024.8070/22.5 mm 30 A 77.31.8.230.8071/22.5 mm 30 A 77.31.9.024.8071/22.5 mm 30 A
## **Ordering information - "Hockey puck" style SSRs**
Example: 77 Series modular SSR, 1 output 25 A AC, input voltage 230 V AC, relay style terminal arrangement, zero-crossing switch-on.
**A B C D 7 7 . A 1 . 8 . 2 3 0 . 8 2 5 0**
## **Series**
## **Type/rated current**
A = 25 A output B = 40 A output
C = 50 A output D = 60 A output E = 75 A output F = 80 A output G = 100 A output H = 125 A output
## **No. of poles/mounting**
- 1 = 1 phase, heat-sink or directly panel mounting (“hockey puck”)
## **D: Switch-on mode**
0 = Zero-crossing
1 = Random
## **C: Terminal arrangement**
- 5 = “Relay style” (input and output on opposite sides)
- 7 = “Contactor style” (input and output on adjacent sides)
**AB: Output circuit**
(rated voltage)
82 = 230 V AC
86 = 600 V AC
2 = 2 phases
3 = 3 phases
**Input version**
8 = AC (50/60 Hz) 9 = DC
**Supply voltage**
See “input specification”
## **Codes/Module width**
**1 phase 25 - 40 - 60 - 80 - 100 - 125 A 2 phases 25 - 50 - 75 A** 77.x1.8.230.8250/"hockey puck" 77.x2.9.024.8671/"hockey puck" 77.x1.9.024.8250/"hockey puck" 77.x1.8.230.8650/"hockey puck" 77.x1.9.024.8650/"hockey puck"
**3 phases 25 - 40 - 60 - 80 A** 77.x3.8.230.8671/"hockey puck" 77.x3.9.024.8671/"hockey puck"
**16**
77 SERIES
## **Technical data**
**==> picture [540 x 468] intentionally omitted <==**
**----- Start of picture text -----**<br>
Insulation 77.01.8xxx 77.01.9xxx 77.11 77.21 77.31<br>Dielectric Impulse Dielectric Impulse Dielectric Impulse Dielectric Impulse Dielectric Impulse<br>strength (1.2/50 µs) strength (1.2/50 µs) strength (1.2/50 µs) strength (1.2/50 µs) strength (1.2/50 µs)<br>Between input and output 2500 V AC 5 kV 3000 V AC 4 kV 3000 V AC 6 kV 3000 V AC 6 kV 3000 V AC 6 kV<br>Between input and ground (heat-sink) — — — — 3000 V AC 6 kV 3000 V AC 6 kV 3000 V AC 6 kV<br>Between output and ground (heat-sink) — — — — 2500 V AC 4 kV 2500 V AC 4 kV 4000 V AC 6 kV<br>EMC specifications Reference 77.01.8.230 77.01.9.024 77.11 77.21 77.31<br>standard<br>230 V AC 24 V DC 24 V DC 230 V AC 24 V DC 230 V AC 24 V AC/DC 230 V AC<br>Electrostatic discharge contact discharge EN 61000-4-2 4 kV 4 kV 4 kV 4 kV 4 kV<br>air discharge EN 61000-4-2 8 kV 8 kV 8 kV 8 kV 8 kV<br>Radiated electromagnetic field (80…1000 MHz) EN 61000-4-3 30 V/m 20 V/m 20 V/m 20 V/m 30 V/m<br>Fast transients on supply terminals<br>(burst 5/50 ns, 5 and 100 kHz) EN 61000-4-4 1 kV 1 kV 1 kV 3 kV 1 kV 3 kV 1 kV 3 kV<br>Voltage pulses on supply common mode EN 61000-4-5 — — 3 kV 3 kV 3 kV 3 kV 3 kV 3 kV<br>terminals (surge 1.2/50 µs) differential mode EN 61000-4-5 1 kV 0.5 kV 0.5 kV 1.5 kV 0.5 kV 1.5 kV 0.5 kV 1.5 kV D<br>Radio-frequency common<br>mode voltage (0.15…230 MHz) on supply terminals EN 61000-4-6 10 V 10 V 10 V 10 V 10 V<br>Terminals 77.01.x.xxx 77.01.9.xxx 77.11 77.21 77.31<br>Screw torque Nm 0.8 0.8 0.8 0.8 0.8<br>Max. wire size solid stranded solid stranded solid stranded solid stranded solid stranded<br>cable cable cable cable cable cable cable cable cable cable<br>mm [2] 1 x 4 / 1 x 4 / 1 x 4 / 1 x 4 / 1 x 6 / 1 x 6 / 1 x 6 / 1 x 6 / 1 x 6 / 1 x 6 /<br>2 x 2.5 2 x 2.5 2 x 2.5 2 x 2.5 2 x 4 2 x 4 2 x 4 2 x 4 2 x 4 2 x 4<br>AWG 1 x 12 / 1 x 12 / 1 x 12 / 1 x 12 / 1 x 10 / 1 x 10 / 1 x 10 / 1 x 10 / 1 x 10 / 1 x 10 /<br>2 x 14 2 x 14 2 x 14 2 x 14 2 x 12 2 x 12 2 x 12 2 x 12 2 x 12 2 x 12<br>Wire strip length mm 9 9 9 9 9<br>Other data<br>Power lost to the environment without output current W 0.5 0.5 0.9 0.9 0.9<br>with rated current W 4.0 4.0 14 15 16<br>77.x1 77.x2 77.x3<br>Dielectric strength Dielectric strength Dielectric strength<br>Between Input and output 4 kV 4 kV 4 kV<br>Between input and ground (heat-sink) 4 kV 2.5 kV 2.5 kV<br>Terminals<br>Screw torque Input side Nm 1.5 0.5 0.5<br>Output side Nm 2.2 2.2 2.2<br>On heatsink with thermal pad or paste Nm 2.2 2.2 2.2<br>**----- End of picture text -----**<br>
## **Recommendation for wiring**
**==> picture [308 x 37] intentionally omitted <==**
**----- Start of picture text -----**<br>
Cross section DIN 46234<br>Load current Wire size<br>area of wire terminal D1 (mm) D2 (mm)<br>(A) (AWG)<br>(mm [2] ) model<br>**----- End of picture text -----**<br>
**==> picture [59 x 133] intentionally omitted <==**
|**Load current**<br>**(A)**|**Cross section**<br>**area of wire**<br>**(mm2)**|**Wire size**<br>**(AWG)**|**DIN 46234**<br>**terminal**<br>**model**|**D1 (mm)**|**D2 (mm)**|
|---|---|---|---|---|---|
|15 - 20|2.5|12|4 - 6|4.3|8|
||||5 - 6|5.3|10|
|20 - 35|4|10|4 - 6|4.3|8|
||||5 - 6|5.3|10|
|25 - 32|6|10|4 - 6|4.3|8|
||||5 - 6|5.3|10|
|32 - 50|10|8|5 - 10|5.3|10|
|50 - 65|16|6|5 - 16|5.3|11|
|65 - 85|25|4|5 - 25|5.3|12|
Note: If the wire cross section area is bigger than 25 mm[2] , we suggest to use 2 smaller cross section wires and connect them back to back superimposed (in parallel).
**17**
77 SERIES
## **Input specification**
D
## **77.01**
**==> picture [298 x 643] intentionally omitted <==**
**----- Start of picture text -----**<br>
Nominal Input Operating range Must Input<br>voltage code AC DC drop-out current<br>voltage<br>UN Umin Umax Umin Umax (AC/DC) IN at UN<br>V V V V V V mA<br>24 9 .024 — — 4 32 3.0 18<br>230 8 .230 90 265 — — 24 15<br>77.11/77.21<br>Nominal Input Operating range Must Input<br>voltage code AC DC drop-out current<br>voltage<br>UN Umin Umax Umin Umax (AC/DC) IN at UN<br>V V V V V V mA<br>24 9 .024 — — 4 32 2 11<br>230 8 .230 40 305 — — 6 25<br>77.31<br>Nominal Input Operating range Must Input<br>voltage code AC DC drop-out current<br>voltage<br>UN Umin Umax Umin Umax (AC/DC) IN at UN<br>V V V V V V mA<br>24 8 .024 16 32 — — 6 10<br>24 9 .024 — — 4 32 2 11<br>230 8 .230 40 280 — — 6 25<br>77.x1.x.xxx.8x50<br>Nominal Input Operating range Must Input<br>voltage code AC DC drop-out current<br>voltage<br>UN Umin Umax Umin Umax (AC/DC) IN at UN<br>V V V V V V mA<br>24 9 .024 — — 3 32 1.25 25<br>230 8 .230 90 280 — — 1.25 35<br>77.x2.9.024.8671<br>Nominal Input Operating range Must Input<br>voltage code AC DC drop-out current<br>voltage<br>UN Umin Umax Umin Umax (AC/DC) IN at UN<br>V V V V V V mA<br>24 9 .024 — — 4 32 1.5 25<br>77.x3.x.xxx.8671<br>Nominal Input Operating range Must Input<br>voltage code AC DC drop-out current<br>voltage<br>UN Umin Umax Umin Umax (AC/DC) IN at UN<br>V V V V V V mA<br>24 9 .024 — — 4 32 1.6 35<br>230 8 .230 90 280 — — 1.6 30<br>**----- End of picture text -----**<br>
## **Led indication**
|**Led indication**||
|---|---|
|LED|Supply voltage|
||OFF|
||ON|
|||
|LED<br>(77.01.9.024.9xxx only)|Short circuit*|
||NO|
||YES|
* To restore normal operation it is necessary to disconnect the power, resolve the short circuit and then restore power.
**18**
77 SERIES
D
## **Output specification**
**L77-1 Output RMS current v ambient temperature 77.01.9.024.805x @ 32 V DC**
**==> picture [179 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
5 A<br>**----- End of picture text -----**<br>
**==> picture [181 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
L77-2 Output RMS current v ambient temperature<br>77.01.8.230.805x @ 265 V AC<br>**----- End of picture text -----**<br>
**==> picture [179 x 87] intentionally omitted <==**
**----- Start of picture text -----**<br>
5 A<br>**----- End of picture text -----**<br>
**I** - Modular SSR installed as a group (without gap)
**II** - Modular SSR installed as a group (9 mm gap between each SSR)
**III** - Modular SSR installed individually in free air (without a significant influence from nearby components)
**L77-3 Output DC current v ambient temperature 77.01.9.024.9024 @ 32 V DC**
**==> picture [179 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
15 A<br>**----- End of picture text -----**<br>
**L77-4 Output DC current v ambient temperature 77.01.9.024.9125 @ 32 V DC**
**==> picture [179 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
7 A<br>**----- End of picture text -----**<br>
**I** - Modular SSR installed as a group (without gap)
**II** - Modular SSR installed individually in free air , or with a gap ≥ 9 mm, which implies a not significant influence from nearby components
## **L77-5 Output RMS current v ambient temperature**
**77.11.x.xxx.82xx**
## **L77-6 Output RMS current v ambient temperature**
**77.21.x.xxx.825x**
**==> picture [179 x 93] intentionally omitted <==**
**----- Start of picture text -----**<br>
15 A<br>**----- End of picture text -----**<br>
**==> picture [179 x 89] intentionally omitted <==**
**----- Start of picture text -----**<br>
25 A<br>**----- End of picture text -----**<br>
- **I** - Modular SSR installed as a group (without gap)
- **II** - Modular SSR installed individually in free air , or with a gap ≥ 20 mm, which implies a not significant influence from nearby components
**I** - Modular SSR installed as a group (without gap)
- **II** - Modular SSR installed individually in free air , or with a gap ≥ 20 mm, which implies a not significant influence from nearby components
## **L77-7 Output RMS current v ambient temperature 77.31.x.xxx.80xx**
**==> picture [179 x 94] intentionally omitted <==**
**----- Start of picture text -----**<br>
30 A<br>**----- End of picture text -----**<br>
- **I** - Modular SSR installed as a group (without gap)
- **II** - Modular SSR installed as a group (20 mm gap between each SSR)
- **III** - Modular SSR installed individually in free air , or with a gap ≥ 40 mm, which implies a not significant influence from nearby components)
**19**
77 SERIES
## **Output specification**
D
**L77-8 Inrush peak current (AC) v inrush time 77.01.x.xxx.80xx**
**==> picture [201 x 145] intentionally omitted <==**
**L77-10 Inrush peak current (AC) v inrush time 77.21.x.xxx.825x**
**==> picture [202 x 154] intentionally omitted <==**
**L77-9 Inrush peak current (AC) v inrush time 77.11.x.xxx.82xx**
**==> picture [202 x 154] intentionally omitted <==**
**L77-11 Inrush peak current (AC) v inrush time 77.31.x.xxx.80xx**
**==> picture [202 x 146] intentionally omitted <==**
**1 - “Cold” conditions** (ambient temperature = 23 °C, no output current during the last 15 minutes)
**2 - “Hot” conditions** (ambient temperature = 50 °C, rated output current)
**20**
77 SERIES
D
## **Output specification**
**L77-12 Output RMS current v ambient temperature 77.A1.x.xxx.8x50**
**==> picture [185 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
25 A<br> Ambient temperature<br>**----- End of picture text -----**<br>
**==> picture [7 x 33] intentionally omitted <==**
**----- Start of picture text -----**<br>
Current (A)<br>**----- End of picture text -----**<br>
- **1 -** Installation on heat-sink 077.21 (2.1 K/W)
- **2 -** Installation on heat-sink 077.13 (1.3 K/W)
**L77-14 Output RMS current v ambient temperature 77.D1.x.xxx.8x50**
**==> picture [184 x 106] intentionally omitted <==**
**----- Start of picture text -----**<br>
60 A<br> Ambient temperature<br>**----- End of picture text -----**<br>
**==> picture [7 x 33] intentionally omitted <==**
**----- Start of picture text -----**<br>
Current (A)<br>**----- End of picture text -----**<br>
- **1 -** Installation on heat-sink 077.03.x.xxx (0.35 K/W)
- **2 -** Installation on heat-sink 077.08 (0.8 K/W)
**L77-16 Output RMS current v ambient temperature 77.G1.x.xxx.8x50**
**==> picture [182 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
100 A<br> Ambient temperature<br>**----- End of picture text -----**<br>
**==> picture [7 x 33] intentionally omitted <==**
**----- Start of picture text -----**<br>
Current (A)<br>**----- End of picture text -----**<br>
- **1 -** Installation on heat-sink 077.03.x.xxx (0.35 K/W)
- **2 -** Installation on heat-sink 077.08 (0.8 K/W)
**L77-13 Output RMS current v ambient temperature 77.B1.x.xxx.8x50**
**==> picture [206 x 107] intentionally omitted <==**
**----- Start of picture text -----**<br>
40 A<br> Ambient temperature<br>Current (A)<br>**----- End of picture text -----**<br>
**1 -** Installation on heat-sink 077.08 (0.8 K/W)
**2 -** Installation on heat-sink 077.13 (1.3 K/W)
**L77-15 Output RMS current v ambient temperature 77.F1.x.xxx.8x50**
**==> picture [252 x 392] intentionally omitted <==**
**----- Start of picture text -----**<br>
80 A<br> Ambient temperature<br>1 - Installation on heat-sink 077.03.x.xxx (0.35 K/W)<br>2 - Installation on heat-sink 077.08 (0.8 K/W)<br>L77-17 Output RMS current v ambient temperature<br>77.H1.x.xxx.8x50<br>125 A<br> Ambient temperature<br>Current (A)<br>Current (A)<br>**----- End of picture text -----**<br>
- **1 -** Installation on heat-sink 077.03.x.xxx (0.35 K/W)
- **2 -** Installation on heat-sink 077.08 (0.8 K/W)
**21**
77 SERIES
## **Output specification**
D
**L77-18 Output RMS current v ambient temperature 77.A2.9.024.8671**
**==> picture [182 x 105] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 x 25 A<br> Ambient temperature<br>**----- End of picture text -----**<br>
**==> picture [6 x 33] intentionally omitted <==**
**----- Start of picture text -----**<br>
Current (A)<br>**----- End of picture text -----**<br>
**1 -** Installation on heat-sink 077.08 (0.8 K/W)
**L77-19 Output RMS current v ambient temperature 77.C2.9.024.8671**
**==> picture [184 x 134] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 x 50 A<br> Ambient temperature<br>**----- End of picture text -----**<br>
**==> picture [7 x 33] intentionally omitted <==**
**----- Start of picture text -----**<br>
Current (A)<br>**----- End of picture text -----**<br>
- **1 -** Installation on heat-sink 077.03.x.xxx (0.35 K/W)
**==> picture [147 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 - Installation on heat-sink 077.08 (0.8 K/W)<br>**----- End of picture text -----**<br>
**L77-20 Output RMS current v ambient temperature 77.E2.9.024.8671**
**==> picture [165 x 133] intentionally omitted <==**
**----- Start of picture text -----**<br>
2 x 75 A<br> Ambient temperature<br>**----- End of picture text -----**<br>
**==> picture [7 x 33] intentionally omitted <==**
**----- Start of picture text -----**<br>
Current (A)<br>**----- End of picture text -----**<br>
**1 -** Installation on heat-sink 077.03.x.xxx (0.35 K/W)
**2 -** Installation on heat-sink 077.08 (0.8 K/W)
**L77-22 Output RMS current v ambient temperature 77.B3.x.xxx.8671**
**==> picture [205 x 192] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 x 40 A<br> Ambient temperature<br>Current (A)<br>**----- End of picture text -----**<br>
- **1 -** Installation on heat-sink 077.03.x.xxx (0.35 K/W)
- **2 -** Installation on heat-sink 077.08 (0.8 K/W)
## **L77-21 Output RMS current v ambient temperature 77.A3.x.xxx.8671**
**==> picture [253 x 394] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 x 25 A<br> Ambient temperature<br>1 - Installation on heat-sink 077.03.x.xxx (0.35 K/W)<br>2 - Installation on heat-sink 077.08 (0.8 K/W)<br>L77-23 Output RMS current v ambient temperature<br>77.D3.x.xxx.8671<br>3 x 60 A<br> Ambient temperature<br>Current (A)<br>Current (A)<br>**----- End of picture text -----**<br>
- **1 -** Installation on heat-sink 077.03.x.xxx (0.35 K/W)
- **2 -** Installation on heat-sink 077.08 (0.8 K/W)
**22**
77 SERIES
D
## **Output specification**
**L77-24 Output RMS current v ambient temperature 77.F3.x.xxx.8671**
**==> picture [252 x 183] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 x 80 A<br> Ambient temperature<br>1 - Installation on heat-sink 077.03.x.xxx (0.35 K/W)<br>Current (A)<br>**----- End of picture text -----**<br>
**L77-25 Output RMS current v ambient temperature 77.F3.x.xxx.8671**
**==> picture [253 x 183] intentionally omitted <==**
**----- Start of picture text -----**<br>
3 x 80 A<br> Ambient temperature<br>2 - Installation on heat-sink 077.08 (0.8 K/W)<br>Current (A)<br>**----- End of picture text -----**<br>
**23**
77 SERIES
## **Output specification**
D
|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|
|---|---|---|---|---|
|Load|**77.01.x.xxx.805x**|**77.01.9.024.9xxx**|**77.11/21**|**77.31**|
|5 A 230 V(AC1)|5000|—|—|—|
|5 A 24 V DC L/R = 20 ms|—|3600|—|—|
|1 A(AC15)|10 000|—|—|—|
|0.5 A(AC15)|20 000|—|—|—|
|15 A 305 V cosφ= 0.8|—|—|1800|—|
|15 A 305 V cosφ= 0.5|—|—|1200|—|
|30 A 480 V cosφ= 0.8|—|—|—|1800|
|30 A 480 V cosφ= 0.5|—|—|—|1200|
|25 A 230 V cosφ= 0.7|—|—|—|—|
|40 A 230 V cosφ= 0.7|—|—|—|—|
|50 A 230 V cosφ= 0.7|—|—|—|—|
||||||
|**Other data**|||||
||**77.01.x.xxx.805x**|**77.01.9.024.9xxx**|**77.11/21**|**77.31**|
|**Critical rising voltage**dv/dt<br>without input control<br>(gate open)<br>@Tj= 125 °C|> 1000 V/µs|> 1000 V/µs|> 500 V/µs<br>> 10 V/µs<br>(with di/dt =<br>20 A/ms)|> 1000 V/µs|
|**Critical rising current**di/dt<br>@Tj= 125 °C|> 50 A/µs|> 50 A/µs|> 50 A/µs|> 150 A/µs|
|**I2t for fusing **@tp= 10 ms|450 A2s|450 A2s|1000 A2s*|1350 A2s**|
|Suggested fuse (depending on application) for short-circuit protection (Ultra-Fast acting types for semiconductors):<br>* 20 A, 660 V AC, 10 x 38 mm, 200 kA, 360 A2s.|||||
** 30 A, 660 V AC, 10 x 38 mm, 200 kA, 1000 A[2] s.
|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|
|---|---|---|---|---|---|---|---|---|---|
|Load|**77.A1.x.xxx**|**77.B1.x.xxx**||**77.D1.x.xxx**|**77.F1.x.xxx**|**77.G1.x.xxx**|||**77.H1.x.xxx**|
|25 A 230 V cosφ= 0.7|1800|—||—|—|—|||—|
|40 A 230 V cosφ= 0.7|—|1800||—|—|—|||—|
|60 A 230 V cosφ= 0.7|—|—||1800|—|—|||—|
|80 A 230 V cosφ= 0.7|—|—||—|1800|—|||—|
|100 A 230 V cosφ= 0.7|—|—||—|—|1800|||—|
|125 A 230 V cosφ= 0.7|—|—||—|—|—|||1800|
|||||||||||
|**Other data**||||||||||
||**77.A1.x.xxx**|**77.B1.x.xxx**||**77.D1.x.xxx**|**77.F1.x.xxx**|**77.G1.x.xxx**|||**77.H1.x.xxx**|
|**Critical rising voltage**dv/dt<br>without input control<br>(gate open) @Tj= 125 °C|500 V/µs|500 V/µs||500 V/µs|500 V/µs|500 V/µs|||500 V/µs|
|**I2t for fusing **@tp= 10 ms|450 A2s|1250 A2s||2450 A2s*|3200 A2s**|11 250 A2s|||25 000 A2s|
|||||||||||
|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)||||||||||
|Load|**77.A2.x.xxx**|||**77.C2.x.xxx**|||**77.E2.x.xxx**|||
|25 A 230 V cosφ= 0.7|1800|||—|||—|||
|50 A 230 V cosφ= 0.7|—|||1800|||—|||
|75 A 230 V cosφ= 0.7|—|||—|||1800|||
|||||||||||
|**Other data**||||||||||
||**77.A2.x.xxx**|||**77.C2.x.xxx**|||**77.E2.x.xxx**|||
|**Critical rising voltage**dv/dt<br>without input control<br>(gate open) @Tj= 125 °C|500 V/µs|||500 V/µs|||500 V/µs|||
|**I2t for fusing **@tp= 10 ms|450 A2s|||2110 A2s|||2810 A2s*|||
|||||||||||
|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)||||||||||
|Load|**77.A3.x.xxx**||**77.B3.x.xxx**||**77.D3.x.xxx**|||**77.F3.x.xxx**||
|25 A 230 V cosφ= 0.7|1800||—||—|||—||
|40 A 230 V cosφ= 0.7|—||1800||—|||—||
|60 A 230 V cosφ= 0.7|—||—||1800|||—||
|80 A 230 V cosφ= 0.7|—||—||—|||1800||
|||||||||||
|**Other data**||||||||||
||**77.A3.x.xxx**||**77.B3.x.xxx**||**77.D3.x.xxx**|||**77.F3.x.xxx**||
|**Critical rising voltage**dv/dt<br>without input control<br>(gate open) @Tj= 125 °C|500 V/µs||500 V/µs||500 V/µs|||500 V/µs||
|**I2t for fusing **@tp= 10 ms|450 A2s||1250 A2s||2450 A2s*|||8190 A2s**||
**24**
77 SERIES
D
## **Wiring diagrams**
**==> picture [512 x 589] intentionally omitted <==**
**----- Start of picture text -----**<br>
Single-phase connection Single-phase connection DC Single-phase connection<br>(77.01…805x) (77.01…9x2x) (77.11/77.21)<br>LOAD<br>Single-phase connection Single-phase connection Example of three-phase connection<br>(77.31…805x) (77.31…807x) (with 3 x 77.01)<br>Note: this connection can be used with all 77 series types.<br>**----- End of picture text -----**<br>
**25**
77 SERIES
## **Wiring diagrams**
**==> picture [511 x 214] intentionally omitted <==**
**----- Start of picture text -----**<br>
Single-phase connection Dual phase connection<br>(77.x1) (77.x2)<br>**----- End of picture text -----**<br>
**==> picture [29 x 54] intentionally omitted <==**
**----- Start of picture text -----**<br>
D<br>**----- End of picture text -----**<br>
**Three phase connection (77.x3)**
**==> picture [174 x 201] intentionally omitted <==**
**26**
77 SERIES
D
## **Outline drawings**
Type 77.01 Box clamp
**==> picture [114 x 158] intentionally omitted <==**
Type 77.01 DC Box clamp
**==> picture [39 x 39] intentionally omitted <==**
**==> picture [69 x 92] intentionally omitted <==**
Type 77.x2 Screw terminal (plate clamp)
**==> picture [85 x 133] intentionally omitted <==**
Types 77.11/21/31 Box clamp
**==> picture [39 x 39] intentionally omitted <==**
**==> picture [38 x 128] intentionally omitted <==**
Type 77.x1 Screw terminal (plate clamp)
**==> picture [86 x 136] intentionally omitted <==**
Type 77.x3 Screw terminal (plate clamp)
**==> picture [180 x 198] intentionally omitted <==**
**27**
77 SERIES
## **Outline drawings**
Type 077.03.x.xxx Box clamp
**==> picture [39 x 39] intentionally omitted <==**
D
**==> picture [147 x 97] intentionally omitted <==**
**==> picture [108 x 115] intentionally omitted <==**
Type 077.08 Box clamp
**==> picture [39 x 40] intentionally omitted <==**
**==> picture [107 x 97] intentionally omitted <==**
Type 077.13 Box clamp
**==> picture [39 x 39] intentionally omitted <==**
**==> picture [106 x 103] intentionally omitted <==**
Type 077.21 Box clamp
**==> picture [40 x 39] intentionally omitted <==**
**==> picture [38 x 75] intentionally omitted <==**
**==> picture [57 x 90] intentionally omitted <==**
**28**
77 SERIES
D
## **Accessories**
**==> picture [443 x 287] intentionally omitted <==**
**----- Start of picture text -----**<br>
Adaptor for panel mounting , plastic, 17.5 mm wide for 77.01 only 020.01<br>= &<br>.<br>020.01 et<br>ni wo<br>2 v<br>Separator for rail mounting , plastic, 9 mm wide 022.09<br>aa 4.3 56.5<br>wo<br>© Ottader ¢<br>g oO<br>‘ =<br>022.09<br>azote = Sheet of marker tags (CEMBRE Thermal transfer printers) for all relays (48 tags), 6 x 12 mm 060.48<br>ePferbers<br>7 +4 +4 t4<br>tt ted otal tel<br>Shee.<br>“Hs Hs ww<br>tyey =<br>060.48<br>**----- End of picture text -----**<br>
Please see general technical information
**29**
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →