- Manufacturer: FINDER
- Product type:
- Contact Configuration:SPST-NO; Load Current:30A; Operating Voltage Max:280VAC; Relay Mounting:DIN Rail; Relay Terminals:Screw; Switching Mode:Zero Crossing; Operating Voltage Min:40VAC;
- SVHC: No SVHC (04-Feb-2026)
- Load Current: 30A
- Product Range: 77 Series
- Relay Mounting: DIN Rail
- Switching Mode: Zero Crossing
- Relay Terminals: Screw
- Control Voltage Max: 480VAC
- Control Voltage Min: 48VAC
- Contact Configuration: SPST-NO
- Operating Voltage Max: 280VAC
- Operating Voltage Min: 40VAC
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 61.22 € |
| Current stock | 10+ |
| Lead time | 30 days |
Solid State Relays 5 - 15 - 30 - 50 A
**77 SЕRIES**
Drying kilns
Heating and cooling Lighting control in corridors (for hotels, offices and hospitals) Bottling plant
Labelling machines Packaging machines
FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products.
**77 SERIES**
**D**
## **5 A modular SSR, 1 NO AC output**
## **77.01.x.xxx.8050**
## **77.01.x.xxx.8051**
- 17.5 mm housing
- 60 to 240 V AC output (with back to back SCR) • 5 kV (1.2/50 µs) insulation between Input and Output
- Zero-crossing and random switch-on versions available
- High switching speed
- High endurance
- Silent switching
- Spark and bounce-free switching
- Low control power
- 3-phase general purpose • 35 mm rail (EN 60715) mount
77.01 Screw terminal
## **Zero-crossing switch-on Suggested applications:**
- Lamp inrush current reduction (CFL - Compact Fluorescent energy-saving Lamps and similar)
- Heater control
## **Random switch-on**
## **Suggested applications:**
- Finer control requiring short operate time (specially motor control)
- AC Input phase different from AC Output phase
- Solenoid, contactor driver
- See L77-3 diagram page 13 ** See L77-1 and L77-2 diagrams page 12
Simplified Simplified For outline drawing see page 16 circuit diagram circuit diagram **Output specification** Output configuration 1 NO (SPST-NO) 1 NO (SPST-NO) Rated current IN/Max. peak current* (10 ms) A ~~a~~ 5/300* 5/300* Rated voltage V AC (50/60 Hz) ~~a~~ 230 230 Switching voltage range V AC (50/60 Hz) ~~a~~ 48…265 48…265 Repetitive peak off-state voltage Vpk ~~a~~ 800 800 Rated load AC7a (cos ϕ = 0.8) A ~~a~~ 5 5 Rated load AC15 A ~~a~~ 5 3 Single phase motor rating (230 V AC) kW ~~a~~ — 0.1 Nominal lamp rating: 230 V incandescent/halogen W 1000 800 fluorescent tubes with electronic ballast W 1000 800 fluorescent tubes with electromechanical ballast W 1000 800 CFL W ~~a~~ 800 400 230 V LED W ~~a~~ 800 400 LV halogen or LED with electronic ballast W 800 400 LV halogen or LED with electromechanical ballast W 1000 800 Minimum switching current @ 230 V mA ~~a~~ 100 100 Typical “OFF-state” leakage current @ 230 V mA ~~a~~ 0.5 3.5 Max “ON-state” voltage drop @ 25 °C and 5 A/100 mA V 0.85/1.5 0.85/1.5 Power loss @ 5 A W 4 4 **Input specification** Nominal voltage (UN) V AC (50/60 Hz) 24 230 24 230 V DC ~~a~~ 12…24 — 12…24 — Rated power VA (50 Hz)/W ~~a~~ 0.6/0.5 3.6/0.3 0.6/0.5 3.6/0.3 Operating range V AC (50/60 Hz) ~~a~~ 16…32 90…265 16…32 90…265 V DC ~~a~~ 9.8…32 — 9.8…32 — Must drop-out voltage V AC (50/60 Hz)/DC 2.4 24 2.4 24 **Technical data** Electrical life cycles 10 · 10[6] 10 · 10[6] Operate/release time ms ~~a~~ 20/12 9/8 Insulation between input and output (1.2/50 µs) kV 5 5 Ambient temperature °C ~~a~~ –20…+70** –20…+70** Protection category ~~a~~ IP 20 IP 20 **Approvals** (according to type) C€ EAL -O-
**3**
**77 SERIES**
**D**
## **7 - 15 A modular SSR, 1 NO DC output**
**==> picture [291 x 125] intentionally omitted <==**
**----- Start of picture text -----**<br>
77.01.9.024.9024 77.01.9.024.9125<br>Cé CG<br>x) x<br>24 V DC output switching 110…125 V DC output<br>15 A rated<br>**----- End of picture text -----**<br>
- 17.5 mm housing
- 2 versions, for 24 and 125 V DC mosfet output
- 4 kV (1.2/50 µs) insulation between Input and Output
- Short circuit protection
- High switching speed
- High endurance
- Silent switching
- Spark and bounce-free switching
**110…125 V DC output switching 7 A rated Applications in Energy, Automation and Machines:**
- Low control power
- Suitable for railway applications
- 35 mm rail (EN 60715) mount
## **Applications in Energy, Automation and Machines:**
## 77.01
- Control of electric, pneumatic and hydraulic electromagnetic valves
## Screw terminal
- Control of electric, pneumatic and hydraulic electromagnetic valves
- Direct control of loads such as motors and electromagnets
|**7 - 15 A modular SSR, 1 NO DC output**<br>• 17.5 mm housing17.5 mm housing<br>• 2 versions, for 24 and 125 V DC mosfet output2 versions, for 24 and 125 V DC mosfet output<br>• 4 kV (1.2/50 µs) insulation between Input and4 kV (1.2/50 µs) insulation between Input and<br>Output<br>• Short circuit protectionShort circuit protection<br>• High switching speedHigh switching speed<br>• High enduranceHigh endurance<br>• Silent switchingSilent switching<br>• Spark and bounce-free switchingSpark and bounce-free switching<br>• Low control powerLow control power<br>• Suitable for railway applicationsSuitable for railway applications<br>• 35 mm rail (EN 60715) mount35 mm rail (EN 60715) mount<br>77.01<br>Screw terminal<br>* See L77-12 and L77-13 diagrams page 12<br>For outline drawing see page 16<br>**Output specification**<br>Output configuration|**77.01.9.024.9024**<br>**24 V DC output switching**<br>**15 A rated**<br>**Applications in Energy,**<br>**Automation and Machines:**<br>• Control of electric, pneumaticControl of electric, pneumatic<br>and hydraulic electromagnetic<br>valves<br>• Direct control of loads such asDirect control of loads such as<br>motors and electromagnets<br>Simplified<br>circuit diagram<br>1 NO (SPST-NO)<br>Cé<br>x)|**77.01.9.024.9125**<br>**110…125 V DC output**<br>**switching**<br>**7 A rated**<br>**Applications in Energy,**<br>**Automation and Machines:**<br>• Control of electric, pneumaticControl of electric, pneumatic<br>and hydraulic electromagnetic<br>valves<br>•Direct control of loads such as<br>motors and electromagnets<br>Simplified<br>circuit diagram<br>1 NO (SPST-NO)<br>CG<br>x|
|---|---|---|
|Rated current IN/Max.peak current (10 ms)<br>A<br>~~DR~~|15/160<br>~~DR~~<br>~~DR~~|7/60<br>~~DR~~<br>|
|Rated voltage<br>V DC<br>~~DRa~~|24<br>~~DR~~<br>~~DRa~~|125<br>~~DR~~<br>|
|Switchingvoltage range<br>V DC<br>~~DRa~~|16…32<br>~~DRa~~|43…140<br>|
|Rated load DC13<br>A<br>~~a~~|5<br>~~aDR~~|2.5<br>~~DR~~|
|DC motor rating<br>kW<br>|0.2<br>~~DR~~<br>~~DR~~|—<br>~~DR~~<br>~~DR~~|
|Minimum switchingcurrent<br>mA<br>~~DR~~|100<br>~~DR~~<br>~~Re~~<br>~~DR~~|50<br>~~DR~~<br>~~Re~~|
|Typical “OFF-state” leakage current<br>mA<br>~~DR~~|3<br>~~DR~~|6|
|Max “ON-state” voltage drop<br>@ 25 °C and IN<br>V<br>~~DR~~|0.06<br>~~DR~~|0.2|
|Power loss @ IN<br>W<br>**Input specification**<br>Nominal voltage (UN)<br>V DC<br>~~a~~|1<br>6…24<br>~~a~~|1.5<br>6…24<br>|
|Ratedpower<br>W<br>~~a~~|0.5<br>~~a~~|0.5<br>|
|Operatingrange<br>V DC<br>~~a~~|4…36<br>~~aLR~~|4…36<br>~~LR~~|
|Must drop-out voltage<br>V DC<br>**Technical data**<br>Electrical life<br>cycles<br>|3<br>10 · 106<br>~~LR~~|3<br>10 · 106<br>~~LR~~|
|Operate/release time<br>ms|0.05/2<br>~~a~~|0.05/2<br>~~a~~|
|Insulation between input<br>and output(1.2/50µs)<br>kV|4|4|
|Ambient temperature<br>°C|–20…+70*<br>~~DR~~|–20…+70*<br>~~DR~~|
|Protection category<br>**Approvals**(according to type)|IP 20<br>IP 20<br>~~DR~~<br>~~a~~<br>C€<br>FALGs||
**4**
**77 SERIES**
**D**
## **15 A modular SSR, 1 NO output**
## **77.11.x.xxx.8250**
## **77.11.x.xxx.8251**
- 22.5 mm housing, heat-sink + plastic cover
- 24 to 277 V AC output (with triac)
- 6 kV (1.2/50 µs) insulation between Input and Output
- Zero-crossing and random switch-on versions available
- High switching speed
- High endurance
- Silent switching
- Spark and bounce-free switching
- Low control power
- 3-phase general purpose
- “Relay-style” terminal arrangement (input and output terminals on opposite sides)
- 35 mm rail (EN 60715) mount
77.11
Screw terminal
**==> picture [86 x 19] intentionally omitted <==**
**----- Start of picture text -----**<br>
Zero-crossing switch-on<br>Suggested applications:<br>**----- End of picture text -----**<br>
- Lamp inrush current reduction (CFL - Compact Fluorescent energy-saving Lamps and similar)
- Heater control
- Solenoid, contactor driver
## **Random switch-on**
**Suggested applications:**
- Fine controls involving shorter time (specially motor control)
* See L77-7 diagram page 13
- ** See L77-6 diagrams page 12
Simplified Simplified circuit diagram circuit diagram
|**15 A modular SSR, 1 NO output**<br>• 22.5 mm housing, heat-sink + plastic cover22.5 mm housing, heat-sink + plastic cover<br>• 24 to 277 V AC output (with triac)24 to 277 V AC output (with triac)<br>• 6 kV (1.2/50 µs) insulation between Input and6 kV (1.2/50 µs) insulation between Input and<br>Output<br>• Zero-crossing and random switch-on versionsZero-crossing and random switch-on versions<br>available<br>• High switching speedHigh switching speed<br>• High enduranceHigh endurance<br>• Silent switchingSilent switching<br>• Spark and bounce-free switchingSpark and bounce-free switching<br>• Low control powerLow control power<br>• 3-phase general purpose3-phase general purpose<br>• “Relay-style” terminal arrangement“Relay-style” terminal arrangement<br>(input and output terminals on opposite sides)<br>• 35 mm rail (EN 60715) mount35 mm rail (EN 60715) mount<br>77.11<br>Screw terminal<br>* See L77-7 diagram page 13<br>** See L77-6 diagrams page 12<br>For outline drawing see page 16<br>**Output specification**<br>Output configuration|**77.11.x.xxx.8250**<br>**Zero-crossing switch-on**<br>**Suggested applications:**<br>• Lamp inrush current reductionLamp inrush current reduction<br>(CFL - Compact Fluorescent<br>energy-saving Lamps and<br>similar)<br>• Heater controlHeater control<br>• Solenoid, contactor driverSolenoid, contactor driver<br>Simplified<br>circuit diagram<br>1 NO (SPST-NO)<br>ee<br>‘ermse<br>os<br>=<br>)<br>one<br>ce<br>C<br>=<br>Al<br>A2<br>rene<br>;<br>;<br>b><br>i<br>if<br>NY]!<br>ig--.-----4!<br>Load<br>L<br>14<br>13|**77.11.x.xxx.8250**<br>**Zero-crossing switch-on**<br>**Suggested applications:**<br>• Lamp inrush current reductionLamp inrush current reduction<br>(CFL - Compact Fluorescent<br>energy-saving Lamps and<br>similar)<br>• Heater controlHeater control<br>• Solenoid, contactor driverSolenoid, contactor driver<br>Simplified<br>circuit diagram<br>1 NO (SPST-NO)<br>ee<br>‘ermse<br>os<br>=<br>)<br>one<br>ce<br>C<br>=<br>Al<br>A2<br>rene<br>;<br>;<br>b><br>i<br>if<br>NY]!<br>ig--.-----4!<br>Load<br>L<br>14<br>13|**77.11.x.xxx.8251**<br>**Random switch-on**<br>**Suggested applications:**<br>• Fine controls involving shorterFine controls involving shorter<br>time (specially motor control)<br>Simplified<br>circuit diagram<br>1 NO (SPST-NO)<br>ee<br>‘oman<br>bd<br>A<br>I<br>oon<br>cc<br>=<br>At<br>A2<br>ree<br>i<br>{RE<br>|<br>SS<br>i<br>i|<br>N<br>|i<br>ig--.-----§!<br>Load<br>L<br>14<br>13|**77.11.x.xxx.8251**<br>**Random switch-on**<br>**Suggested applications:**<br>• Fine controls involving shorterFine controls involving shorter<br>time (specially motor control)<br>Simplified<br>circuit diagram<br>1 NO (SPST-NO)<br>ee<br>‘oman<br>bd<br>A<br>I<br>oon<br>cc<br>=<br>At<br>A2<br>ree<br>i<br>{RE<br>|<br>SS<br>i<br>i|<br>N<br>|i<br>ig--.-----§!<br>Load<br>L<br>14<br>13|
|---|---|---|---|---|
|Rated current IN/Max.peak current* (10 ms)<br>A|15/400*||15/400*||
|Rated voltage<br>V AC (50/60 Hz)|230||230||
|Switchingvoltage range<br>V AC (50/60 Hz)|19…305||19…305||
|Repetitivepeak off-state voltage<br>Vpk|800||800||
|Rated load AC7a (cosϕ= 0.8, @ 25 °C)<br>A|20||20||
|Rated load AC15<br>A|15||15||
|Singlephase motor rating(230 V AC)<br>kW|—||0.75||
|Nominal lamp rating:<br>230 V incandescent/halogen W<br>fluorescent tubes with<br>electronic ballast W<br>fluorescent tubes with<br>electromechanical ballast W<br>CFL W<br>230 V LED W<br>LV halogen or LED with<br>electronic ballast W<br>LV halogen or LED with<br>electromechanical ballast W|4000||2500||
||4000||2500||
||2000||1000||
||3000||1500||
||3000||1500||
||3000||1500||
||3000||1500||
|Minimum switchingcurrent @ 250 V<br>mA|100||100||
|Typical “OFF-state” leakage current @ 250 V<br>mA|1||1||
|Max “ON-state” voltage drop<br>@ 25 °C and 15 A<br>V|1.55||1.55||
|Power loss @ 15 A<br>W<br>**Input specification**<br>Nominal voltage (UN)<br>V AC (50/60 Hz)<br>V DC|14<br>—<br>230||14<br>—<br>230||
||24|—|24|—|
|Ratedpower<br>VA (50 Hz)/W|0.4|7.5/0.9|0.4|7.5/0.9|
|Operating range<br>V AC (50/60 Hz)<br>V DC|—|40…305|—|40…305|
||4…32|—|4…32|—|
|Must drop-out voltage<br>V AC (50/60 Hz)/DC<br>**Technical data**<br>Electrical life<br>cycles|—/2<br>6/—<br>10 · 106||—/2<br>6/—<br>10 · 106||
|Operate/release time<br>ms|< 10/< 10|< 10/< 30|< 1/< 10|< 2/< 25|
|Insulation between input<br>and output(1.2/50µs)<br>kV|6||6||
|Ambient temperature<br>°C|–20…+80**||–20…+80**||
|Protection category<br>**Approvals**(according to type)|IP 20<br>IP 20<br>C€<br>FAL@«||||
**5**
**77 SERIES**
**D**
## **30 A modular SSR, 1 NO output**
- 22.5 mm housing, heat-sink + plastic cover
- 60 to 440 V AC output (with back to back SCR)
- 6 kV (1.2/50 µs) insulation between Input and Output
- Zero-crossing and random switch-on versions available
- High switching speed
- High endurance
- Silent switching
- Spark and bounce-free switching
- Low control power
- 3-phase general purpose
- “Relay-style” terminal arrangement (input and output terminals on opposite sides)
- 35 mm rail (EN 60715) mount
## 77.31 Screw terminal
- See L77-5 diagram page 13
- ** See L77-4 diagrams page 12
For outline drawing see page 16
**77.31.x.xxx.8050 77.31.x.xxx.8051** owe ee coed tare = = lens Gea ee ee c ae **Zero-crossing switch-on** Al A2 **Random switch-on** Al A2 **Suggested applications:** ane **Suggested applications:** ane • Lamp inrush current i • Finer control requiring short ; reduction (CFL - Compact ;( i **i** operate time ;; Fluorescent energy-saving i (specially motor control) i wo! i wo! Lamps and similar) i 1 Rh i • Heater control • Solenoid, contactor driver | L Load L Load 13 14 13 14 Simplified Simplified circuit diagram circuit diagram
## **Output specification**
|Output configuration|1 NO (SPST-NO)|1 NO (SPST-NO)|||1 NO (SPST-NO)|1 NO (SPST-NO)|
|---|---|---|---|---|---|---|
|Rated current IN/Max.peak current* (10 ms)<br>A|30/520*||||30/520*||
|Rated voltage<br>V AC (50/60 Hz)|400||||400||
|Switchingvoltage range<br>V AC (50/60 Hz)|48…480||||48…480||
|Repetitivepeak off-state voltage<br>Vpk|1100||||1100||
|Rated load AC7a (cosϕ= 0.8)<br>A|30||||30||
|Rated load AC15<br>A|20||||20||
|Singlephase motor rating(230 V AC)<br>kW|—||||1.5||
|Nominal lamp rating:<br>230 V incandescent/halogen W|6000||||4500||
|fluorescent tubes with<br>electronic ballast W|6000||||4000||
|fluorescent tubes with<br>electromechanical ballast W|3000||||1800||
|CFL W|4000||||2500||
|230 V LED W|4000||||2500||
|LV halogen or LED with<br>electronic ballast W|4000||||2500||
|LV halogen or LED with<br>electromechanical ballast W|4000||||2500||
|Minimum switchingcurrent @ 400 V<br>mA|300||||300||
|Typical “OFF-state” leakage current @ 400 V<br>mA|1||||1||
|Max “ON-state” voltage drop<br>@ 25 °C and 30 A<br>V|0.85||||0.85||
|Power loss @ 30 A<br>W<br>**Input specification**|16||||16||
|Nominal voltage (UN)<br>V AC (50/60 Hz)|—|230|||—|230|
|V DC|24|—|||24|—|
|Ratedpower @ UMAX<br>VA (50 Hz)/W|0.4|7.5/0.9|||0.4|7.5/0.9|
|Operating range<br>V AC (50/60 Hz)|—|40…280|||—|40…280|
|V DC|4…32|—|||4…32|—|
|Must drop-out voltage<br>V AC (50/60 Hz)/DC|—/2|6/—|||—/2|6/—|
|**Technical data**|||||||
|Electrical life<br>cycles|10 · 106||||10 · 106||
|Operate/release time<br>ms<br>Insulation between input<br>and output(1.2/50µs)<br>kV<br>Ambient temperature<br>°C<br>Protection category<br>**Approvals**(according to type)|< 10/< 10<br>< 10/< 30<br>6<br>–20…+80**<br>IP 20||< 10/< 30<br>C€|FAL|< 1/< 10<br>< 2/< 25<br>6<br>–20…+80**<br>IP 20<br>FAL-@=||
**==> picture [6 x 74] intentionally omitted <==**
**----- Start of picture text -----**<br>
VII-2018, www.findernet.com<br>**----- End of picture text -----**<br>
**6**
**77 SERIES**
## **30 A modular SSR, 1 NO output**
## **77.31.x.xxx.8070**
## **77.31.x.xxx.8071**
- 22.5 mm housing, heat-sink + plastic cover
- 60 to 440 V AC output (with back to back SCR)
- 6 kV (1.2/50 µs) insulation between Input and Output
- Zero-crossing and random switch-on versions available
- High switching speed
- High endurance
- Silent switching
- Spark and bounce-free switching
- Low control power
- 3-phase general purpose
- “Contactor-style” terminal arrangement (input and output terminals on adjacent sides)
- 35 mm rail (EN 60715) mount
## 77.31 Screw terminal
## **Zero-crossing switch-on**
## **Random switch-on**
## **Suggested applications:**
**Suggested applications:**
- Lamp inrush current reduction ~~!~~ ! ~~i~~ i • Fine controls involving shorter ! i (CFL - Compact Fluorescent !!ii time (specially motor control) i ; energy-saving Lamps and similar) iY ooh | | ~~iv~~ e tah |!
- Heater control
- Solenoid, contactor driver
**D**
- See L77-5 diagram page 13
- ** See L77-4 diagrams page 12
For outline drawing see page 16
Simplified Simplified circuit diagram circuit diagram
## **Output specification**
||Output configuration|1 NO (SPST-NO)|1 NO (SPST-NO)|||1 NO (SPST-NO)|1 NO (SPST-NO)|
|---|---|---|---|---|---|---|---|
||Rated current IN/Max.peak current* (10 ms)<br>A|30/520*||||30/520*||
||Rated voltage<br>V AC (50/60 Hz)|400||||400||
||Switchingvoltage range<br>V AC (50/60 Hz)|48…480||||48…480||
||Repetitivepeak off-state voltage<br>Vpk|1100||||1100||
||Rated load AC7a (cosϕ= 0.8)<br>A|30||||30||
||Rated load AC15<br>A|20||||20||
||Singlephase motor rating(230 V AC)<br>kW|—||||1.5||
||Nominal lamp rating:<br>230 V incandescent/halogen W|6000||||4500||
||fluorescent tubes with<br>electronic ballast W|6000||||4000||
||fluorescent tubes with<br>electromechanical ballast W|3000||||1800||
||CFL W|4000||||2500||
||230 V LED W|4000||||2500||
||LV halogen or LED with<br>electronic ballast W|4000||||2500||
||LV halogen or LED with<br>electromechanical ballast W|4000||||2500||
||Minimum switchingcurrent @ 400 V<br>mA|300||||300||
||Typical “OFF-state” leakage current @ 400 V<br>mA|1||||1||
||Max “ON-state” voltage drop<br>@ 25 °C and 30 A<br>V|0.85||||0.85||
||Power loss @ 30 A<br>W<br>**Input specification**|16||||16||
||Nominal voltage (UN)<br>V AC (50/60 Hz)|—|230|||—|230|
||V DC|24|—|||24|—|
|Ratedpower<br>VA (50 Hz)/W||0.4|7.5/0.9|||0.4|7.5/0.9|
|Operating range<br>V AC (50/60 Hz)||—|40…280|||—|40…280|
||V DC|4…32|—|||4…32|—|
||Must drop-out voltage<br>V AC (50/60 Hz)/DC|—/2|6/—|||—/2|6/—|
||**Technical data**|||||||
||Electrical life<br>cycles|10 · 106||||10 · 106||
||Operate/release time<br>ms<br>Insulation between input<br>and output(1.2/50µs)<br>kV<br>Ambient temperature<br>°C<br>Protection category<br>**Approvals**(according to type)|< 10/< 10<br>< 10/< 30<br>6<br>–20…+80**<br>IP 20||< 10/< 30<br>C€|FAL|< 1/< 10<br>< 2/< 25<br>6<br>–20…+80**<br>IP 20<br>FAL@s||
**7**
**77 SERIES**
**D**
## **25, 40 And 50 A panel SSR, “hockey puck” style**
## **77.25.x.xxx.8250**
## **77.45.x.xxx.8250**
## **77.55.x.xxx.8250**
- “hockey puck” housing with cover
- 24 to 240 V AC output
- Zero-crossing version
- High switching speed
- High endurance
- Silent switching
- Spark and bounce-free switching
- Low control power
- 3-phase general purpose
- “Relay-style” terminal arrangement (input and output terminals on opposite sides)
## **Zero-crossing switch-on**
- Output: 25 A/230 V AC
- Suggested applications: heater control
**Zero-crossing switch-on**
- Output: 40 A/230 V AC
- Suggested applications: heater control
## **Zero-crossing switch-on**
- Output: 50 A/230 V AC
- Suggested applications: heater control
- Mounting on heatsink with screws
77.x5
Screw terminal (plate clamp)
- See L77-11 diagrams page 13
** See L77-8, L77-9 and L77-10 diagrams page 13
Simplified circuit diagram
Simplified circuit diagram
Simplified circuit diagram
|For outline drawing see page 16|Simplified circuit diagram|Simplified circuit diagram|Simplified circuit diagram|Simplified circuit diagram|Simplified circuit diagram|Simplified circuit diagram|Simplified circuit diagram|
|---|---|---|---|---|---|---|---|
|**Output specification**<br>Output configuration|1 NO(SPST-NO)||1 NO|1 NO(SPST-NO)||1 NO(SPST-NO)||
|Rated current IN/Max.peak current*(10 ms)<br>A|25/300*|||40/500*||50/520*||
|Rated voltage<br>V AC(50/60 Hz)|230|||230||230||
|Switchingvoltage range<br>V AC(50/60 Hz)|21.6…280|||21.6…280||21.6…280||
|Repetitivepeak off-state voltage<br>Vpk|600|||600||600||
|Nominal lamp rating:<br>230 V incandescent/halogen W|2000|||4000||6000||
|fluorescent tubes with<br>electronic ballast W|2000|||4000||6000||
|fluorescent tubes with<br>electromechanical ballast W|1000|||2000||3000||
|CFL W|800|||3000||4000||
|230 V LED W|800|||3000||4000||
|LV halogen or LED with<br>electronic ballast W|800|||3000||4000||
|LV halogen or LED with<br>electromechanical ballast W|1000|||3000||4000||
|Minimum switchingcurrent @ 250 V<br>mA|120|||250||250||
|Typical “OFF-state” leakage current @ 250 V<br>mA|10|||10||10||
|Max “ON-state” voltage<br>drop@ 25 °C and IN<br>V|1.6|||1.6||1.6||
|Power loss @ IN<br>W<br>**Input specification**|40|||64||80||
|Nominal voltage (UN)<br>V AC(50/60 Hz)|—|230|—||230|—|230|
|V DC|24|—|24||—|24|—|
|Ratedpower @ UMAX<br>VA(50 Hz)/W|—/0.6|2.4/—|—/0.6||2.4/—|—/0.6|2.4/—|
|Operating range<br>V AC(50/60 Hz)|—|90…280|—||90…280|—|90…280|
|V DC|3…32|—|3…32||—|3…32|—|
|Must drop-out voltage<br>V AC (50/60 Hz)/DC|—/1|10/—|—/1||10/—|—/1|10/—|
|**Technical data**||||||||
|Electrical life<br>cycles|10 · 10|10 · 106||10 · 10|10 · 106|10 · 10|10 · 106|
|Operate/release time<br>ms<br>Insulation between input<br>and output(1.2/50µs)<br>kV<br>Ambient temperature<br>°C<br>Protection category<br>**Approvals**(according to type)|10/10<br>40/80<br>5.6<br>–30…+80**<br>IP 20||10/10<br>40/80<br>5.6<br>–30…+80**<br>IP 20<br>®<br>C€<br>FALAds|||10/10<br>40/80<br>5.6<br>–30…+80**<br>IP 20||
**8**
**77 SERIES**
**D**
**25, 40 And 50 A panel SSR, “hockey puck” style**
## **77.25.x.xxx.8650**
## **77.45.x.xxx.8650**
## **77.55.x.xxx.8650**
- “hockey puck” housing with cover
- 48 to 600 V AC output
- Zero-crossing version
- High switching speed
- High endurance
- Silent switching • Spark and bounce-free switching
- Low control power
- 3-phase general purpose
- “Relay-style” terminal arrangement (input and output terminals on opposite sides)
## **Zero-crossing switch-on**
- Output: 25 A/600 V AC
- Suggested applications: heater control
**Zero-crossing switch-on**
- Output: 40 A/600 V AC
- Suggested applications: heater control
## **Zero-crossing switch-on**
- Output: 50 A/600 V AC
- Suggested applications: heater control
- Mounting on heatsink with screws
77.x5
Screw terminal (plate clamp)
- See L77-11 diagrams page 13
|**25, 40 And 50 A panel SSR,**<br>**“hockey puck” style**<br>• “hockey puck” housing with cover“hockey puck” housing with cover<br>• 48 to 600 V AC output48 to 600 V AC output<br>• Zero-crossing versionZero-crossing version<br>• High switching speedHigh switching speed<br>• High enduranceHigh endurance<br>• Silent switchingSilent switching<br>• Spark and bounce-free switchingSpark and bounce-free switching<br>• Low control powerLow control power<br>• 3-phase general purpose3-phase general purpose<br>• “Relay-style” terminal arrangement“Relay-style” terminal arrangement<br>(input and output terminals on opposite sides)<br>• Mounting on heatsink with screwsMounting on heatsink with screws<br>77.x5<br>Screw terminal (plate clamp)<br>* See L77-11 diagrams page 13<br>** See L77-8, L77-9 and L77-10 diagrams page 13<br>For outline drawing see page 16<br>**Output specification**<br>Output configuration|**77.25.x.xxx.8650**<br>**Zero-crossing switch-on**<br>• Output: 25 A/600 V ACOutput: 25 A/600 V AC<br>• Suggested applications:Suggested applications:<br>heater control<br>eGe<br>]<br>@tinder<br>eenr °° seen<br>€<br>e|**77.25.x.xxx.8650**<br>**Zero-crossing switch-on**<br>• Output: 25 A/600 V ACOutput: 25 A/600 V AC<br>• Suggested applications:Suggested applications:<br>heater control<br>eGe<br>]<br>@tinder<br>eenr °° seen<br>€<br>e|**77.45.x.xxx.8650**<br>**Zero-crossing switch-on**<br>• Output: 40 A/600 V ACOutput: 40 A/600 V AC<br>• Suggested applications:Suggested applications:<br>heater control<br>eGe<br>]<br>@tinder<br>ear °° seee<br>€<br>€|**77.45.x.xxx.8650**<br>**Zero-crossing switch-on**<br>• Output: 40 A/600 V ACOutput: 40 A/600 V AC<br>• Suggested applications:Suggested applications:<br>heater control<br>eGe<br>]<br>@tinder<br>ear °° seee<br>€<br>€|**77.55.x.xxx.8650**<br>**Zero-crossing switch-on**<br>• Output: 50 A/600 V ACOutput: 50 A/600 V AC<br>• Suggested applications:Suggested applications:<br>heater control<br>eGe<br>]<br>@tinder<br>guar °° sees<br>€<br>e|**77.55.x.xxx.8650**<br>**Zero-crossing switch-on**<br>• Output: 50 A/600 V ACOutput: 50 A/600 V AC<br>• Suggested applications:Suggested applications:<br>heater control<br>eGe<br>]<br>@tinder<br>guar °° sees<br>€<br>e|
|---|---|---|---|---|---|---|
||1 NO(SPST-NO)<br>os<br>a||1 NO(SPST-NO)<br>as<br>ae||1 NO(SPST-NO)<br>as<br>a||
|Rated current IN/Max.peak current*(10 ms)<br>A|25/300*||40/500*||50/520*||
|Rated voltage<br>V AC(50/60 Hz)|600||600||600||
|Switchingvoltage range<br>V AC(50/60 Hz)|43.2…660||43.2…660||43.2…660||
|Repetitivepeak off-state voltage<br>Vpk|1200||1200||1200||
|Nominal lamp rating:<br>230 V incandescent/halogen W<br>fluorescent tubes with<br>electronic ballast W<br>fluorescent tubes with<br>electromechanical ballast W<br>CFL W<br>230 V LED W<br>LV halogen or LED with<br>electronic ballast W<br>LV halogen or LED with<br>electromechanical ballast W|2000||4000||6000||
||2000||4000||6000||
||1000||2000||3000||
||800||3000||4000||
||800||3000||4000||
||800||3000||4000||
||1000||3000||4000||
|Minimum switchingcurrent @ 250 V<br>mA|120||250||250||
|Typical “OFF-state” leakage current @ 250 V<br>mA|10||10||10||
|Max “ON-state” voltage drop<br>@ 25 °C and IN<br>V|1.6||1.6||1.6||
|Power loss @ IN<br>W<br>**Input specification**<br>Nominal voltage (UN)<br>V AC(50/60 Hz)<br>V DC|40<br>—<br>230||64<br>—<br>230||80<br>—<br>230||
||24|—|24|—|24|—|
|Ratedpower @ UMAX<br>VA(50 Hz)/W|—/0.6|2.4/—|—/0.6|2.4/—|—/0.6|2.4/—|
|Operating range<br>V AC(50/60 Hz)<br>V DC|—|90…280|—|90…280|—|90…280|
||4…32|—|4…32|—|4…32|—|
|Must drop-out voltage<br>V AC (50/60 Hz)/DC<br>**Technical data**<br>Electrical life<br>cycles|—/1<br>10/—<br>10 · 106||—/1<br>10/—<br>10 · 106||—/1<br>10/—<br>10 · 106||
|Operate/release time<br>ms|10/10|40/80|10/10|40/80|10/10|40/80|
|Insulation between input<br>and output(1.2/50µs)<br>kV|5.6||5.6||5.6||
|Ambient temperature<br>°C|–30…+80**||–30…+80**||–30…+80**||
|Protection category|IP 20||IP 20||IP 20||
|**Approvals**(according to type)|C€<br>FAL|||®<br>FAL cAdus|||
**9**
**77 SERIES**
## **Ordering information**
Example: 77 series modular SSR, 1 output 30 A AC, input voltage 230 V AC, relay style terminals arrangement, zero-crossing switch-on.
**D**
**A B C D 8 0 5 0**
## **7 7 . 3 1 . 8 . 2 3 0 . 8 0**
## **Series**
## **D: Switch-on mode**
## **Type/rated current**
0 = Zero-crossing
- 1 = Random
- 0 = 5/7/15 A output (77.01)
- 1 = 15 A output (77.11)
## **C: Terminals arrangement**
- 2 = 25 A output (77.25)
- 5 = “Relay style” (input and output on opposite sides)
- 3 = 30 A output (77.31)
- 4 = 40 A output (77.45)
- 7 = “Contactor style” (input and output on adjacent sides)
- 5 = 50 A output (77.55)
## **No. of poles/mounting**
## **AB: Output circuit**
1 = 1 pole, modular housing (plastic or heat sink/plastic), DIN rail mounting
(rated voltage)
80 = 230 V AC (77.01), 400 V AC (77.31) 82 = 230 V AC (77.11, 77.x5) 86 = 600 V AC (77.x5) 9024 = 24 V DC 9125 = 110…125 V DC
- 5 = 1 pole, heat-sink or directly panel mounting
(“hockey puck”)
## **Input version**
0 = DC/AC (50/60 Hz)
- 8 = AC (50/60 Hz)
- 9 = DC
## **Supply voltage**
See “input specification”
## **Codes/Module width**
77.01.8.230.8050/17.5 mm 5 A 77.11.8.230.8250/22.5 mm 15 A 77.31.8.230.8050/22.5 mm 30 A 77.01.0.024.8050/17.5 mm 5 A 77.11.9.024.8250/22.5 mm 15 A 77.31.9.024.8050/22.5 mm 30 A 77.01.8.230.8051/17.5 mm 5 A 77.11.8.230.8251/22.5 mm 15 A 77.31.8.230.8051/22.5 mm 30 A 77.01.0.024.8051/17.5 mm 5 A 77.11.9.024.8251/22.5 mm 15 A 77.31.9.024.8051/22.5 mm 30 A 77.01.9.024.9125/17.5 mm 7 A 77.31.8.230.8070/22.5 mm 30 A 77.01.9.024.9024/17.5 mm 15 A 77.31.9.024.8070/22.5 mm 30 A 77.31.8.230.8071/22.5 mm 30 A 77.31.9.024.8071/22.5 mm 30 A
77.25.8.230.8250/hockey puck 25 A 77.25.9.024.8250/hockey puck 25 A 77.25.8.230.8650/hockey puck 25 A 77.25.9.024.8650/hockey puck 25 A 77.45.8.230.8250/hockey puck 40 A 77.45.9.024.8250/hockey puck 40 A 77.45.8.230.8650/hockey puck 40 A 77.45.9.024.8650/hockey puck 40 A 77.55.8.230.8250/hockey puck 50 A 77.55.9.024.8250/hockey puck 50 A 77.55.8.230.8650/hockey puck 50 A 77.55.9.024.8650/hockey puck 50 A
## **Technical data**
**==> picture [511 x 354] intentionally omitted <==**
**----- Start of picture text -----**<br>
77.01.8xxx 77.01.9xxx 77.11 77.31 72.25/45/55<br>Dielectric Impulse Dielectric Impulse Dielectric Impulse Dielectric Impulse Dielectric Impulse<br>strength (1.2/50 µs) strength (1.2/50 µs) strength (1.2/50 µs) strength (1.2/50 µs) strength (1.2/50 µs)<br>Between input and output 2500 V AC 5 kV 3000 V AC 4 kV 3000 V AC 6 kV 3000 V AC 6 kV 4000 V AC 5.6 kV<br>Between input and ground (heat-sink) — — — — 3000 V AC 6 kV 3000 V AC 6 kV 4000 V AC 5.6 kV<br>Between output and ground (heat-sink) — — — — 2500 V AC 4 kV 4000 V AC 6 kV 4000 V AC 5.6 kV<br>EMC specifications Reference 77.01.x.xxx 77.01.9.xxx 77.11 77.31 77.25/45/55<br>standard<br>24 V AC/DC 230 V AC 24 V DC 24 V DC 230 V AC 24 V DC 230 V AC 24 V DC - 230 V AC<br>Electrostatic discharge contact discharge EN 61000-4-2 4 kV 4 kV 4 kV 4 kV 4 kV<br>air discharge EN 61000-4-2 8 kV 8 kV 8 kV 8 kV 8 kV<br>Radiated electromagnetic field (80…1000 MHz) EN 61000-4-3 30 V/m — 20 V/m 30 V/m —<br>Fast transients on supply terminals<br>(burst 5/50 ns, 5 and 100 kHz) EN 61000-4-4 1 kV 4 kV 2 kV 1 kV 3 kV 1 kV 3 kV 2 kV<br>Voltage pulses on supply common mode EN 61000-4-5 2 kV 4 kV 1 kV 3 kV 3 kV 3 kV 3 kV 2 kV<br>terminals (surge 1.2/50 µs) differential mode EN 61000-4-5 1 kV 4 kV 0.5 kV 0.5 kV 1.5 kV 0.5 kV 1.5 kV 1 kV<br>Radio-frequency common<br>mode voltage (0.15…230 MHz) on supply terminals EN 61000-4-6 — 10 V 10 V 10 V —<br>Terminals 77.01.x.xxx 77.01.9.xxx 77.11 77.31 77.25/45/55<br>Input Output<br>Screw torque Nm 0.8 0.8 0.8 0.8 0.5 1.2<br>Max. wire size solid stranded solid stranded solid stranded solid stranded solid and stranded<br>cable cable cable cable cable cable cable cable cable<br>mm [2] 1 x 6 / 1 x 4 / 1 x 6 / 1 x 4 / 1 x 6 / 1 x 6 / 1 x 6 / 1 x 6 / 1 (with 4 (with<br>2 x 4 2 x 2.5 2 x 4 2 x 2.5 2 x 4 2 x 4 2 x 4 2 x 4 ferrule) ferrule)<br>10 (with<br>fork tip)<br>AWG 1 x 10 / 1 x 12 / 1 x 10 / 1 x 12 / 1 x 10 / 1 x 10 / 1 x 10 / 1 x 10 / 18 (with 12 (with<br>2 x 12 2 x 14 2 x 12 2 x 14 2 x 12 2 x 12 2 x 12 2 x 12 ferrule) ferrule)<br>8 (with<br>fork tip)<br>Wire strip length mm 9 9 9 9 10 10<br>Other data<br>Power lost to the environment without output current W 0.5 0.5 0.9 0.9 0.6<br>with rated current W 4.0 4.0 14 16 40/64/80<br>**----- End of picture text -----**<br>
**10**
**77 SERIES**
## **Input specification**
**77.01**
**==> picture [297 x 494] intentionally omitted <==**
**----- Start of picture text -----**<br>
Nominal Input Operating range Must Input<br>voltage code AC DC drop-out current<br>voltage<br>UN Umin Umax Umin Umax (AC/DC) IN at UN<br>V V V V V V mA<br>24 0 .024 16 32 9.8 32 2.4 25<br>24 9 .024 — — 4 32 3.0 18<br>230 8 .230 90 265 — — 24 15<br>77.11<br>Nominal Input Operating range Must Input<br>voltage code AC DC drop-out current<br>voltage<br>UN Umin Umax Umin Umax (AC/DC) IN at UN<br>V V V V V V mA<br>24 9 .024 — — 4 32 2 11<br>230 8 .230 40 305 — — 6 25<br>77.31<br>Nominal Input Operating range Must Input<br>voltage code AC DC drop-out current<br>voltage<br>UN Umin Umax Umin Umax (AC/DC) IN at UN<br>V V V V V V mA<br>24 9 .024 — — 4 32 2 11<br>230 8 .230 40 280 — — 6 25<br>77.x5.x.xxx.8250<br>Nominal Input Operating range Must Input<br>voltage code AC DC drop-out current<br>voltage<br>UN Umin Umax Umin Umax (AC/DC) IN at UN<br>V V V V V V mA<br>24 9 .024 — — 3 32 1 22<br>230 8 .230 90 280 — — 10 20<br>77.x5.x.xxx.8650<br>Nominal Input Operating range Must Input<br>voltage code AC DC drop-out current<br>voltage<br>UN Umin Umax Umin Umax (AC/DC) IN at UN<br>V V V V V V mA<br>24 9 .024 — — 4 32 1 25<br>230 8 .230 90 280 — — 10 10<br>**----- End of picture text -----**<br>
## **Led indication**
|**Led indication**||
|---|---|
|LED|Supply voltage|
||OFF|
||ON|
|||
|LED<br>(77.01.9.024.9xxx only)|Short circuit*|
||NO|
||YES|
* To restore normal operation it is necessary to disconnect the power, resolve the short circuit and **D** then restore power.
**11**
**77 SERIES**
## **Output specification**
**L77-1 Output RMS current v ambient temperature 77.01.0.024.805x @ 32 V DC**
**==> picture [187 x 93] intentionally omitted <==**
**----- Start of picture text -----**<br>
5 A<br>**----- End of picture text -----**<br>
**L77-2 Output RMS current v ambient temperature 77.01.8.230.805x @ 265 V AC**
**==> picture [187 x 93] intentionally omitted <==**
**----- Start of picture text -----**<br>
5 A<br>**----- End of picture text -----**<br>
**I** - Modular SSR installed as a group (without gap)
**II** - Modular SSR installed as a group (9 mm gap between each SSR)
**D III** - Modular SSR installed individually in free air (without a significant influence from nearby components)
**L77-12 Output DC current v ambient temperature 77.01.9.024.9024 @ 32 V DC**
**L77-13 Output DC current v ambient temperature 77.01.9.024.9125 @ 32 V DC**
**==> picture [187 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
15 A<br>**----- End of picture text -----**<br>
**==> picture [195 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
8<br>7 A<br>6<br>4<br>2<br>**----- End of picture text -----**<br>
**I** - Modular SSR installed as a group (without gap)
**II** - Modular SSR installed individually in free air , or with a gap ≥ 9 mm, which implies a not significant influence from nearby components
## **L77-6 Output RMS current v ambient temperature 77.11.x.xxx.82xx**
**==> picture [187 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
15 A<br>**----- End of picture text -----**<br>
**L77-4 Output RMS current v ambient temperature 77.31.x.xxx.80xx**
**==> picture [187 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
30 A<br>**----- End of picture text -----**<br>
**I** - Modular SSR installed as a group (without gap)
**II** - Modular SSR installed individually in free air , or with a gap ≥ 20 mm, which implies a not significant influence from nearby components
**I** - Modular SSR installed as a group (without gap)
**II** - Modular SSR installed as a group (20 mm gap between each SSR) **III** - Modular SSR installed individually in free air , or with a gap ≥ 40 mm, which implies a not significant influence from nearby components)
**12**
**77 SERIES**
**D**
## **Output specification**
**L77-10 Output RMS current v ambient temperature 77.25.x.xxx.8x50**
**==> picture [8 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
60<br>40<br>**----- End of picture text -----**<br>
**==> picture [183 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
25 A<br>**----- End of picture text -----**<br>
**1 -** Installation on 077.25 heat-sink (2 K/W)
**2 -** Installation individually in free-air
**L77-9 Output RMS current v ambient temperature 77.45.x.xxx.8x50**
**==> picture [193 x 101] intentionally omitted <==**
**----- Start of picture text -----**<br>
60<br>40 A<br>40<br>**----- End of picture text -----**<br>
**1 -** Installation on 077.55 heat-sink (0.9 K/W)
- **2 -** Installation individually in free-air
## **L77-8 Output RMS current v ambient temperature**
## **77.55.x.xxx.8x50**
**==> picture [8 x 34] intentionally omitted <==**
**----- Start of picture text -----**<br>
60<br>40<br>**----- End of picture text -----**<br>
**==> picture [183 x 98] intentionally omitted <==**
**----- Start of picture text -----**<br>
50 A<br>**----- End of picture text -----**<br>
**1 -** Installation on 077.55 heat-sink (0.9 K/W)
**2 -** Installation individually in free-air
**==> picture [158 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
L77-3 Inrush peak current (AC) v inrush time<br>**----- End of picture text -----**<br>
**L77-7 Inrush peak current (AC) v inrush time**
**77.01.x.xxx.80xx**
**77.11.x.xxx.82xx**
**==> picture [206 x 149] intentionally omitted <==**
**==> picture [209 x 160] intentionally omitted <==**
**==> picture [158 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
L77-5 Inrush peak current (AC) v inrush time<br>**----- End of picture text -----**<br>
**==> picture [163 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
L77-11 Inrush peak current (AC) v inrush time<br>**----- End of picture text -----**<br>
**77.31.x.xxx.80xx**
**77x5.x.xxx.8x50**
**==> picture [209 x 149] intentionally omitted <==**
**==> picture [209 x 149] intentionally omitted <==**
- **1 - Cold” conditions** (ambient temperature = 23 °C, no output current during the last 15 minutes)
- **2 - “Hot” conditions** (ambient temperature = 50 °C, rated output current)
**13**
**77 SERIES**
## **Output specification**
**D**
|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|**Max recommended switching frequency**(Cycles/Hour, with 50% Duty-cycle)|
|---|---|---|---|---|---|---|---|
|Load|**77.01.8xxx**|**77.01.9xxx**|**77.11**|**77.31**|**77.25**|**77.45**|**77.55**|
|5 A 230 V(AC1)|5000|—|—|—|—|—|—|
|5 A 24 V DC L/R = 20 ms|—|3600||||||
|1 A(AC15)|10000|—|—|—|—|—|—|
|0.5 A(AC15)|20000|—|—|—|—|—|—|
|15 A 305 V cosϕ= 0.8|—|—|1800|—|—|—|—|
|15 A 305 V cosϕ= 0.5|—|—|1200|—|—|—|—|
|30 A 480 V cosϕ= 0.8|—|—|—|1800|—|—|—|
|30 A 480 V cosϕ= 0.5|—|—|—|1200|—|—|—|
|25 A 230 V cosϕ= 0.7|—|—|—|—|1800|—|—|
|40 A 230 V cosϕ= 0.7|—|—|—|—|—|1800|—|
|50 A 230 V cosϕ= 0.7|—|—|—|—|—|—|1800|
|||||||||
|**Other data**||||||||
||**77.01.8xxx**|**77.01.9xxx**|**77.11**|**77.31**|**77.25**|**77.45**|**77.55**|
|**Critical rising voltage**dv/dt<br>without input control<br>(gate open)<br>@ Tj= 125 °C|> 1000 V/µs|> 1000 V/µs|> 500 V/µs<br>> 10 V/µs<br>(with di/dt =<br>20 A/ms)|> 1000 V/µs|300 V/µs<br>(..8250)<br>500 V/µs<br>(..8650)|500 V/µs<br>(..8250)<br>1000 V/µs<br>(..8650)|1000 V/µs<br>(..8250)<br>1000 V/µs<br>(..8650)|
|**Critical rising current**di/dt<br>@Tj= 125 °C|> 50 A/µs|> 50 A/µs|> 50 A/µs|> 150 A/µs|—|—|—|
|**I2t for fusing**<br>@tp= 10 ms|450 A2s|450 A2s|1000 A2s*|1350 A2s**|450 A2s|1250 A2s|1350 A2s|
Suggested fuse (depending on application) for short-circuit protection (Ultra-Fast acting types for semiconductors):
* 20 A, 660 V AC, 10 x 38 mm, 200 kA, 360 A[2] s.
** 30 A, 660 V AC, 10 x 38 mm, 200 kA, 1000 A[2] s.
**14**
**77 SERIES**
**D**
## **Wiring diagrams**
**==> picture [512 x 584] intentionally omitted <==**
**----- Start of picture text -----**<br>
Single-phase connection Single-phase connection DC Single-phase connection (77.11) Single-phase connection<br>(77.01.....802x) (77.01.....9x2x) (77.31....805x)<br>LOAD<br>Single-phase connection<br>Single-phase connection (77.x5) Example of three-phase connection (with 3 x 77.01)<br>(77.31....807x)<br>Note: this connection can be used with all 77 series types.<br>**----- End of picture text -----**<br>
**15**
**77 SERIES**
## **Outline drawings**
Type 77.01 Screw terminal
Types 77.11/31 Screw terminal
**==> picture [11 x 11] intentionally omitted <==**
**----- Start of picture text -----**<br>
D<br>**----- End of picture text -----**<br>
**==> picture [44 x 17] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type 77.01 DC<br>Screw terminal<br>**----- End of picture text -----**<br>
**==> picture [84 x 18] intentionally omitted <==**
**----- Start of picture text -----**<br>
Type 77.x5<br>Screw terminal (plate clamp)<br>**----- End of picture text -----**<br>
## **Accessories**
**==> picture [22 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
022.09<br>**----- End of picture text -----**<br>
**==> picture [22 x 5] intentionally omitted <==**
**----- Start of picture text -----**<br>
020.01<br>**----- End of picture text -----**<br>
**==> picture [353 x 228] intentionally omitted <==**
**----- Start of picture text -----**<br>
Adaptor for panel mounting , plastic, 17.5 mm wide for 77.01 only 020.01<br>17 7 5 .<br>©<br>g/e ACIPG<br>ilnone 9<br>[| 2<br>Separator for rail mounting , plastic, 9 mm wide 022.09<br>g 8<br>8<br>iz i<br>33.8 33.8<br>49.3 49 . 3<br>Sheet of marker tags (CEMBRE Thermal transfer printers) for all relays (48 tags), 6 x 12 mm 060.48<br>**----- End of picture text -----**<br>
**==> picture [22 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
060.48<br>**----- End of picture text -----**<br>
**16**
**77 SERIES**
## **Accessories**
**==> picture [316 x 9] intentionally omitted <==**
**----- Start of picture text -----**<br>
Heat-sink , anodized aluminium, 2 K/W, 65 x 100 mm, for 77.25 only 077.25<br>**----- End of picture text -----**<br>
- Both the SSR and 35 mm rail clip mount to the heat-sink using M4 screws (supplied with heat-sink)
- Before assembling to the heat-sink, it is necessary to apply a thin and even layer of thermal conductive paste (not supplied) to the lower metal surface of the SSR
**==> picture [22 x 6] intentionally omitted <==**
**----- Start of picture text -----**<br>
077.25<br>**----- End of picture text -----**<br>
**D**
**==> picture [59 x 7] intentionally omitted <==**
**----- Start of picture text -----**<br>
077.25 with 77.25<br>**----- End of picture text -----**<br>
**Heat-sink** , anodized aluminium, 0.9 K/W, 111 x 100 mm, for 77.45 and 77.55 077.55
- Both the SSR and 35 mm rail clip mount to the heat-sink using M4 screws (supplied with heat-sink)
- Before assembling to the heat-sink, it is necessary to apply a thin and even layer of thermal conductive paste (not supplied) to the lower metal surface of the SSR
## **077.55**
077.55 with 77.45/55
Please see general technical information
**17**
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →