Image not available
Illustrative purposes only
751101
Safety Relay, 24 VDC, DPST-NO, DIN Rail, 3 A, Spring Clamp
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: PILZ
- Product type: Safety Relays
- Coil Voltage:24VDC; Contact Configuration:DPST-NO; Product Range:PNOZ s1 Series; Relay Mounting:DIN Rail; Contact Current:3A; Relay Terminals:Spring Clamp; Contact Voltage AC Nom:240V;
- SVHC: No SVHC (04-Feb-2026)
- IP Rating: IP20, IP40, IP54
- Coil Voltage: 24VDC
- Product Range: -
- Relay Mounting: DIN Rail
- Contact Current: 3A
- Relay Terminals: Spring Clamp
- Contact Material: Silver Tin Oxide
- Contact Configuration: DPST-NO
- Contact Voltage AC Nom: 240V
- Contact Voltage DC Nom: 24V
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 144.96 € |
| Current stock | 10+ |
| Lead time | 30 days |
E-STOP relays, safety gate monitors
## **Up to PL c of EN ISO 13849-1** PNOZ s1
## **Unit features**
E-STOP pushbuttons Safety gates
merkmaleRelay outputs:
][BildunterschriftSafety relay for monitoring E-STOP pushbuttons and safety gates.
## **Approvals**
- 2 safety contacts (N/O), instantaneous
- 1 semiconductor output Connection options for:
- E-STOP pushbutton
- Safety gate limit switch
- Reset button
A connector can be used to connect 1 PNOZsigma contact expander module LED indicator for:
- Supply voltage
- Input status, channel 1
## **Safety features**
][Sicherheitseigenschaften Schaltgerät_allgemeiner TeilThe relay meets the following safety requirements:
The circuit is redundant with built-in self-monitoring.
The safety function remains effective in the case of a component failure.
The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. rheitseigenschaften Zusatz - Sicherung DC_PNOZThe unit has an electronic fuse.
- Input status, channel 2
- Switch status, safety contacts
**PNOZ s1**
- Reset circuit
- Error
Plug-in connection terminals (either spring-loaded terminal or screw terminal)
## **Unit description**
Bestimmung/Gertebeschreibung NOT-AUS, Schutz_PNOZThe safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with
## **Block diagram**
B **l** o **c** kshatbild
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-392-2010-10
E-STOP relays, safety gate monitors
**==> picture [72 x 42] intentionally omitted <==**
## **Up to PL c of EN ISO 13849-1** PNOZ s1
- Automatic start: Unit is active once the input circuit has been closed.
## **Function description**
- ][Funktionen_einkanalig � Single-channel operation: no re][Funktionen_manuStart � Manual reset: Unit is active once dundancy in the input circuit, earth the input circuit is closed and then faults in the reset and input circuit the reset circuit is closed. are detected. ][Funktionen_Kontaktvervielfachung_PNOZsigma � Increase in the number of available
- ][Funktionen_Kontaktvervielfachung_PNOZsigma � Increase in the number of available instantaneous safety contacts by
connecting contact expander modules or external contactors/relays; A connector can be used to connect 1 PNOZsigma contact expander module.
## **Timing diagram**
**==> picture [483 x 144] intentionally omitted <==**
**----- Start of picture text -----**<br>
meit d a ons _u ][Zgr<br>� �<br>� �<br>�����<br>�����������<br>�����<br>�����������<br>����<br>�� �� �� �� �� �� �� ��<br>��<br>**----- End of picture text -----**<br>
## **Key**
- Power: Supply voltage
- Reset/Start: Reset circuit S34
- Input: Input circuits A1-A2
- Output safe: Safety contacts 13-14, 23-24
- Semi: Semiconductor outputY32
- � : Automatic reset
- � : Manual reset
- a: Input circuit closes before reset circuit
- b: Reset circuit closes before input circuit
- t1: Switch-on delay
- t2: Delay-on de-energisation
- t3: Recovery time
## **Wiring**
][Verdrahtung_Si_unverzPlease note:
- Information given in the “Technical details” must be followed.
- Outputs 13-14, 23-24 are safety contacts.
- To prevent contact welding, a fuse should be connected before the output contacts (see technical details).
- Calculation of the max. cable runs lmax in the input circuit:
- ������
- �����
- �������
- Rlmax = max. overall cable resistance (see technical details) Rl /km = cable resistance/km
- Use copper wire that can withstand 60/75 °C.
- Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads.
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-392-2010-10
E-STOP relays, safety gate monitors
## **Up to PL c of EN ISO 13849-1** PNOZ s1
## **Preparing for operation**
## Supply voltage
**==> picture [334 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Supply voltage AC DC<br>**----- End of picture text -----**<br>
## Input circuit
**==> picture [382 x 286] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input circuit Single-channel Dual-channel<br>E-STOP<br>without detection of shorts across con- rota; aa aaAl SI L+<br>I<br>tacts<br>;; I<br>; I<br>Ha<br>loo I<br>Safety gate Mh<br>without detection of shorts across con-<br>tacts pots t ttn = irst<br>HI A1 O—~1-— L+<br>i]<br>i]<br>loos<br>Reset circuit<br>Reset circuit Reset circuit Feedback circuit<br>Automatic reset<br>i A ;<br>-<br>! 13<br>! ; 14<br>Manual reset<br>**----- End of picture text -----**<br>
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-392-2010-10
E-STOP relays, safety gate monitors
## **Up to PL c of EN ISO 13849-1** PNOZ s1
## Semiconductor output
*Connect together the 0V connections on all the external power supplies
## Key
- S1 E-STOP pushbutton
- S3 Reset button Switch operated Gate open Gate closed
## ][Betriebsbereitschaft_herstellen_Info_Grundgert_DB **INFORMATION**
If a base unit and a contact expansion module from the PNOZsigma range are linked via the connector, no additional wiring is necessary.
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-392-2010-10
E-STOP relays, safety gate monitors
**==> picture [72 x 42] intentionally omitted <==**
## **Up to PL c of EN ISO 13849-1** PNOZ s1
## **Terminal configuration**
**==> picture [316 x 211] intentionally omitted <==**
**----- Start of picture text -----**<br>
K nlem bu g<br>**----- End of picture text -----**<br>
## **Installation**
## **Dimensions**
## ][Montage_PNOZsigma **Install base unit without contact expander module:**
- Ensure that the plug terminator is inserted at the side of the unit.
## **Connect base unit and PNOZsigma contact expander module:**
- Remove the plug terminator at the side of the base unit and at the contact expander module.
- Connect the base unit and the contact expander module to the supplied connector before mounting the units to the DIN rail.
## **Installation in control cabinet**
- The safety relay should be installed in a control cabinet with a protection type of at least IP54.
**==> picture [316 x 163] intentionally omitted <==**
**----- Start of picture text -----**<br>
n Abm es ug<br>�������������<br>����������<br>�������������<br>������������<br>**----- End of picture text -----**<br>
- Use the notch on the rear of the unit to attach it to a DIN rail (35 mm).
- When installed vertically: Secure the unit by using a fixing element (e.g. retaining brakket or end angle).
- Push the unit upwards or downwards before lifting it from the DIN rail.
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-392-2010-10
E-STOP relays, safety gate monitors
**==> picture [72 x 42] intentionally omitted <==**
## **Up to PL c of EN ISO 13849-1** PNOZ s1
## **NOTICE**
][WICHTIG_PDB_altThis data sheet is only intended for use during configuration. For installation and operation, please refer to the operating instructions supplied with the unit.
## **Technical details**
## **Electrical data**
**==> picture [242 x 34] intentionally omitted <==**
|Supply voltage||
|---|---|
|Supplyvoltage UB DC|**24 V**|
|Voltage tolerance|**-15 %/+10 %**|
|Power consumption at UB DC|**2.0 W**|
|Residual ripple DC|**20 %**|
|Voltage and current at||
|Input circuit DC:**24.0 V**|**60.0 mA**|
|Reset circuit DC:**24.0 V**|**20.0 mA**|
|Feedback loopDC:**24.0 V**|**20.0 mA**|
|Number of output contacts||
|Safetycontacts(S)instantaneous:|**2**|
|Utilisation category in accordance with**EN 60947-4-1**||
|Safety contacts: AC1 at**240 V**|Imin:**0.02 A**, Imax:**3.0 A**|
||Pmax:**720 VA**|
|Safety contacts: DC1 at**24 V**|Imin:**0.02 A**, Imax:**3.0 A**|
||Pmax:**72 W**|
|Utilisation category in accordance with**EN 60947-5-1**||
|Safety contacts: AC15 at**230 V**|Imax:**1.5 A**|
|Safetycontacts: DC13 at**24 V** (6 cycles/min)|Imax:**1.5 A**|
|Contact material|**AgSnO2**|
|External contact fuse protection (IK= 1 kA) to**EN 60947-5-1**||
|Blow-out fuse, quick||
|Safety contacts:|**4 A**|
|Blow-out fuse, slow||
|Safety contacts:|**2 A**|
|Circuit breaker 24 VAC/DC, characteristic B/C||
|Safetycontacts:|**2 A**|
|Semiconductor outputs(short circuitproof)|**24.0 V**DC,**20 mA**|
|Max. overall cable resistance Rlmax||
|input circuits, reset circuits||
|single-channel at UB DC|**30 Ohm**|
|**Safety-related characteristic data**||
|PL in accordance with**EN ISO 13849-1**|**PL c** (**Cat. 3**)|
|Categoryin accordance with**EN 954-1**|**Cat. 3**|
|SIL CL in accordance with**EN IEC 62061**|**SIL CL 2**|
|PFH in accordance with**EN IEC 62061**|**2.00E-07**|
|SIL in accordance with**IEC 61511**|**SIL 2**|
|PFD in accordance with**IEC 61511**|**5.95E-03**|
|tMinyears|**20**|
|**Times**||
|Switch-on delay||
|with automatic reset typ.|**100 ms**|
|with automatic reset max.|**150 ms**|
|with automatic reset after power on typ.|**100 ms**|
|with automatic reset after power on max.|**150 ms**|
|with manual reset typ.|**50 ms**|
|with manual reset max.|**60 ms**|
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-392-2010-10
E-STOP relays, safety gate monitors
**==> picture [72 x 42] intentionally omitted <==**
## **Up to PL c of EN ISO 13849-1** PNOZ s1
|**Times**||
|---|---|
|Delay-on de-energisation||
|with E-STOP typ.|**30 ms**|
|with E-STOP max.|**40 ms**|
|with power failure typ.|**30 ms**|
|withpower failure max.|**40 ms**|
|Recovery time at max. switching frequency 1/s||
|after E-STOP|**100 ms**|
|afterpower failure|**100 ms**|
|Supplyinterruption before de-energisation|**10 ms**|
|**Environmental data**||
|EMC|**EN 60947-5-1**, **EN 61000-6-2**, **EN 61000-6-4**|
|Vibration to**EN 60068-2-6**||
|Frequency|**10 - 55 Hz**|
|Amplitude|**0.35 mm**|
|Climatic suitability|**EN 60068-2-78**|
|Airgap creepage in accordance with**EN 60947-1**||
|Pollution degree|**2**|
|Overvoltage category|**III**|
|Rated insulation voltage|**250 V**|
|Rated impulse withstand voltage|**4.00 kV**|
|Ambient temperature|**-10 - 55 °C**|
|Storage temperature|**-40 - 85 °C**|
|Protection type||
|Mounting (e.g. cabinet)|**IP54**|
|Housing|**IP40**|
|Terminals|**IP20**|
|**Mechanical data**||
|Housing material||
|Housing|**PC**|
|Front|**PC**|
|Cross section of external conductors with screw terminals||
|1 core flexible|**0.25 - 2.50 mm² , 24 - 12 AWG**No. 750101|
|2 core, same cross section, flexible:||
|with crimp connectors, without insulating sleeve|**0.25 - 1.00 mm² , 24 - 16 AWG**No. 750101|
|without crimpconnectors or with TWIN crimpconnectors|**0.20 - 1.50 mm², 24 - 16 AWG**No. 750101|
|Torque settingwith screw terminals|**0.50 Nm**No. 750101|
|Cross section of external conductors with spring-loaded termi-|**0.20 - 2.50 mm² , 24 - 12 AWG**No. 751101|
|nals: Flexible with/without crimpconnectors||
|Spring-loaded terminals: Terminal points per connection|**2**No. 751101|
|Strippinglength|**9 mm**No. 751101|
|Dimensions||
|Height|**100.0 mm**No. 751101|
||**98.0 mm**No. 750101|
|Width|**12.5 mm**|
|Depth|**120.0 mm**|
|Weight|**105g**|
Technische Daten_Satz No.
## No. stands for order number.
All the units used within a safety function must be considered when calculating the safety characteristic data.
The standards current on **2006-04** apply.
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-392-2010-10
E-STOP relays, safety gate monitors
**==> picture [72 x 42] intentionally omitted <==**
## **Up to PL c of EN ISO 13849-1** PNOZ s1
## **Conventional thermal current**
|Ith (A)at UB DC|||||
|---|---|---|---|---|
|1 contact|**3.00 A**||||
|2 contacts|**3.00 A**||||
|||Bestelldaten|||
|**Order reference**|||||
||||||
|**Type**|**Features**||**Terminals**|**Order no.**|
|PNOZ s1||24 VDC|With screw terminal|750 101|
|PNOZ s1 C||24 VDC|With spring-loaded terminal|751 101|
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-392-2010-10
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →