750167
General Purpose Relay, PNOZ s7.1 Series, Interface, 3PST-NO, 24 VDC, 6 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: PILZ
- Product type: Other Relay Accessories
- Contact Configuration:3PST-NO; Coil Voltage:24VDC; Contact Current:6A; Product Range:-; Relay Mounting:DIN Rail; Coil Type:-; Contact Voltage VAC:240VAC; Relay Terminals:Screw; Contact
- SVHC: No SVHC (27-Jun-2024)
- Coil Voltage: 24VDC
- Product Range: -
- Relay Mounting: DIN Rail
- Coil Resistance: 30ohm
- Contact Current: 6A
- Relay Terminals: Screw
- Contact Material: Silver Copper Nickel
- Contact Voltage VAC: 240VAC
- Contact Voltage VDC: 24VDC
- Contact Configuration: 3PST-NO
| Delivery and price | |
|---|---|
| Units per pack | 5 |
| Price | 144.34 € |
| Current stock | 10+ |
| Lead time | 30 days |
Contact expansions ## **Up to PL e of EN ISO 13849-1** PNOZ s7.1 ][Bildunterschrift KontakterweiterungenContact expansion module for increasing the number of available contacts ## **Approvals** **==> picture [46 x 106] intentionally omitted <==** **----- Start of picture text -----**<br> PNOZ s7.1<br><br><br><br>**----- End of picture text -----**<br> ## **Unit features** - Gertemerkmale Positive-guided relay outputs: – 3 safety contacts (N/O), instantaneous - Safe separation of safety contacts 13-14, 23-24, 33-34 from all other circuits - Supply voltage for expansion modules - LED for: - Supply voltage at B1 and B2 - Input status, channel 1 - Input status, channel 2 - Switch status of the safety contacts - Error - Plug-in connection terminals (either spring-loaded terminals or screw terminals) ## **Unit description** Bestimmung/Gerätebeschreibung Kontakterweiterungen Schalt_PNOZThe unit meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1. The contact expansion module is used to increase the number of instantaneous safety contacts available on a base unit. Base units are all safety relays with feedback loop monitoring. The category that can be achieved in accordance with EN 954-1 and EN ISO 13849-1 depends on the category of the base unit. The contact expansion module may not exceed this. ## **Safety features** Sicherheitseigenschaften Kontakterweiterungen allg_PNOZThe unit meets the following safety requirements: - The contact expansion module expands an existing circuit. As the output relays are monitored via the base unit's feedback loop, the safety functions on the existing circuit are transferred to the contact expansion module. - The safety function remains effective in the case of a component failure. - Earth fault in the feedback loop: Detected, depending on the base unit that is used. - Earth fault in the input circuit: The output relays de-energise and the safety contacts open. ## **Block diagram** **==> picture [3 x 3] intentionally omitted <==** **----- Start of picture text -----**<br> B l o c kshatbild<br>**----- End of picture text -----**<br> - Safe separation in accordance with EN 60947-1, 6 kV Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de 1001988-EN-05-2012-11 Contact expansions **==> picture [72 x 42] intentionally omitted <==** ## **Up to PL e of EN ISO 13849-1** PNOZ s7.1 without PNOZsigma base unit: ## **Function description** - Single-channel operation: one input - ][Funktionsbeschreibung_Erweiterungsgerte_Kaskadenmodul with PNOZsigma base unit: circuit affects the output relays Dual-channel operation via with PNOZsigma s7.2 expander units: - Dual-channel operation via PNOZsigma connector - Dual-channel operation and supply voltage via PNOZsigma connector ## **Timing diagram** **==> picture [483 x 116] intentionally omitted <==** **----- Start of picture text -----**<br> rm wx-f Zeit d aonku PNOsK _ ][g<br>�����<br>�����<br>�����������<br>��������<br>�� �� �� ��<br>**----- End of picture text -----**<br> ## **Key** - Power: Supply voltage - Input: Input circuits - Output safe: Safety contacts 13-14, 23-24, 33-34 - t1: Switch-on delay - t2: Delay-on de-energisation - Feedback: Feedback loop 51-52 ## **Wiring** ][Verdrahtung_Si_unverzPlease note: - Information given in the “Technical details” must be followed. - Outputs 13-14, 23-24, 33-34 are safety contacts. - To prevent contact welding, a fuse should be connected before the output contacts (see technical details). - Calculation of the max. cable runs lmax in the input circuit: - ������ - ����� - ������� Rlmax = max. overall cable resistance (see technical details) Rl /km = cable resistance/km - Use copper wire that can withstand 60/75 °C. - Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de 1001988-EN-05-2012-11 Contact expansions ## **Up to PL e of EN ISO 13849-1** PNOZ s7.1 ## **Preparing for operation** - Supply voltage **==> picture [334 x 166] intentionally omitted <==** **----- Start of picture text -----**<br> Supply voltage AC DC<br>Base unit:<br>Safety relay PNOZsigma<br>Base unit:<br>Safety relay PNOZ X<br>Supply voltage for expansion modules<br>PNOZsigma<br>**----- End of picture text -----**<br> - Input circuit |Input circuit|Single-channel|Dual-channel| |---|---|---| |Base unit:<br>Safety relay PNOZsigma||----------,<br>po---------<br>i<br>ef<br>23 IPNOZsigma<br>PNOZsigma<br>i<br>!<br>baseunit<br>=g jexpansion modula<br>a| |Base unit:<br>Safety relay PNOZ X|24V DCo~~n~~<br>| ~~CO~~<br>I<br>I<br>~~a om~~ ‘Ai PNOZsigmai<br>I<br>expansion<br>|!<br>~~I [* A2 module~~<br>~~H~~<br>OV|| |Base unit:<br>Safety relay PNOZelog Driven via semicon-<br>ductor outputs (24 VDC)|--------,<br>-o----<br>~~o——9~~ A1 PNOZsigma!<br>o1¢<br>expansion<br>H<br>module<br>i<br>OV<br>I<br>|<br>A2<br>|<br>---o---!<br>Liiip4-----<br>~~rees ~~Gy|| Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de 1001988-EN-05-2012-11 Contact expansions ## **Up to PL e of EN ISO 13849-1** PNOZ s7.1 - Reset circuit/feedback loop Reset circuit/feedback loop Base unit: Safety relay PNOZ X Base unit: Safety relay PNOZelog The inputs that evaluate the feedback loop --------4! pono onnn--8 tionwill depend on the base unit and applicafeedback I | | --------, poccono - Connection to PNOZsigma base unit Base unit: Safety relay PNOZsigma The feedback loop is connected and evaluated via the connector. > ][Betriebsbereitschaft_herstellen_Info_Erweiterungsgert_Kaskadenmodul_DB **INFORMATION** If a base unit and a contact expansion module from the PNOZsigma range are linked via the connector, no additional wiring is necessary. Do not connect A1 und Y1/Y2 to the expansion module! Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de 1001988-EN-05-2012-11 Contact expansions **==> picture [72 x 42] intentionally omitted <==** ## **Up to PL e of EN ISO 13849-1** PNOZ s7.1 ## **Terminal configuration** - K **nlem** bu **g** ����� - **Installation** Connect the base unit and the con- **Control cabinet installation** tact expansion module using the The safety relay should be installed - Montage PNOZsigma_7_1 **Install contact expansion module** connector supplied, before mountin a control cabinet with a protec- **without base unit:** ing the units to the DIN rail. tion type of at least IP54. Ensure that the plug terminator is **Connect contact expansion module** Use the notch on the rear of the unit inserted at the side of the unit. **PNOZ s7.1 to PNOZsigma contact** to attach it to a DIN rail (35 mm). - **Connect base unit and contact exexpansion modules** When installed vertically: Secure **pansion module PNOZ s7.1:** Connect the contact expansion the unit by using a fixing element Remove the plug terminator at the modules using the connector sup(e.g. retaining brakket or end angle). side of the base unit and at the left plied. Push the unit upwards or downwards of the contact expansion module before lifting it from the DIN rail. **==> picture [483 x 167] intentionally omitted <==** **----- Start of picture text -----**<br> Expansion options Please note the max. power consumption of the contact expansion modules (see Technical data<br>PNOZ s7.1).<br> : Base unit<br> : Contact expansion module<br>PNOZ s7.1<br> : Contact expansion module<br>PNOZ s7.2<br> : Contact expansion module<br>PNOZ s7.2 with terminator �����������������<br>� � � �<br>������������������� ������������������������������ ������������������������������ ������������������������������ ������������������������������<br>**----- End of picture text -----**<br> Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de 1001988-EN-05-2012-11 Contact expansions ## **Up to PL e of EN ISO 13849-1** PNOZ s7.1 : Base unit : Contact expansion module PNOZ s7.1 : Contact expansion module PNOZ s7.2 : Contact expansion module PNOZ s7, s8, s9, s10, s11 as terminator : Contact expansion module PNOZ s7.1 with terminator : Contact expansion module PNOZ s7.2 : Contact expansion module PNOZ s7.2 with terminator : Contact expansion module PNOZ s7.1 with terminator : Contact expansion module PNOZ s7.2 : Contact expansion module PNOZ s7, s8, s9, s10, s11 as terminator : Base unit : Contact expansion module PNOZ s7.1 : Contact expansion module PNOZ s7.2 : Contact expansion module PNOZ s7.1 : Contact expansion module PNOZ s7.2 : Contact expansion module PNOZ s7.2 with terminator Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de 1001988-EN-05-2012-11 Contact expansions ## **Up to PL e of EN ISO 13849-1** PNOZ s7.1 ## **Dimensions** **==> picture [118 x 9] intentionally omitted <==** **----- Start of picture text -----**<br> Abmessungen*with spring-loaded terminals<br>**----- End of picture text -----**<br> Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de 1001988-EN-05-2012-11 Contact expansions ## **Up to PL e of EN ISO 13849-1** PNOZ s7.1 ## **NOTICE** ][Wichtig_PDBThis data sheet is only intended for use during configuration. Please refer to the operating manual for installation and operation. ## **Service life graph** Lebensdauerkurve_Relais_Text vor KurveThe service life graphs indicate the Lkv **e** bnsda **ur** number of cycles from which failures fo}Oo due to wear must be expected. The oO wear is mainly caused by the electrical xog 10000 -SSa SS RS load; the mechanical load is negligible. > Lebensdauerkurve_Relais_Text nach Kurve_SIF Bsp **Example** - Inductive load: 0,2 A - Utilisation category: AC15 - Contact service life: 2,000,000 cycles Provided the application requires fewer than 2,000,000 cycles, the PFH value (see technical details) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts. With capacitive loads, any power surges that occur must be noted. With contactors, use freewheel diodes for spark suppression. ## **Technical details** |**Electrical data**|| |---|---| |Supply voltage|| |Supplyvoltage UB DC|**24 V**| |Voltage tolerance|**-20 %/+20 %**| |Power consumption at UB DC|**2.0 W**| |Max. output of all expansion modules|**20 W**| |Residual ripple DC|**20 %**| |Voltage and current at|| |Input circuit DC:**24.0 V**|**70.0 mA**| |Number of output contacts|| |Safetycontacts(S)instantaneous:|**3**| Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de 1001988-EN-05-2012-11 Contact expansions **==> picture [72 x 42] intentionally omitted <==** ## **Up to PL e of EN ISO 13849-1** PNOZ s7.1 ## **Electrical data** |Utilisation category in accordance with**EN 60947-4-1**|| |---|---| |Safety contacts: AC1 at**240 V**|Imin:**0.01 A**, Imax:**6.0 A**| ||Pmax:**1500 VA**| |Safety contacts: DC1 at**24 V**|Imin:**0.01 A**, Imax:**6.0 A**| ||Pmax:**150 W**| |Utilisation category in accordance with**EN 60947-5-1**|| |Safety contacts: AC15 at**230 V**|Imax:**5.0 A**| |Safetycontacts: DC13 at**24 V** (6 cycles/min)|Imax:**5.0 A**| |Contact material|**AgCuNi + 0.2µm Au**| |External contact fuse protection (IK= 1 kA) to**EN 60947-5-1**|| |Blow-out fuse, quick|| |Safety contacts:|**10 A**| |Blow-out fuse, slow|| |Safety contacts:|**6 A**| |Circuit breaker 24 VAC/DC, characteristic B/C|| |Safetycontacts:|**6 A**| |Max. overall cable resistance Rlmax|| |input circuits, reset circuits|| |single-channel at UB DC|**30 Ohm**| |**Safety-related characteristic data**|| |PL in accordance with**EN ISO 13849-1: 2006**|**PL e** (**Cat. 4**)| |Categoryin accordance with**EN 954-1**|**Cat. 4**| |SIL CL in accordance with**EN IEC 62061**|**SIL CL 3**| |PFH in accordance with**EN IEC 62061**|**2.31E-09**| |SIL in accordance with**IEC 61511**|**SIL 3**| |PFD in accordance with**IEC 61511**|**2.03E-06**| |TM [year]in accordance with**EN ISO 13849-1: 2006**|**20**| |**Times**|| |Switch-on delay|| |with automatic reset after power on typ.|**30 ms**| |with automatic reset afterpower on max.|**50 ms**| |Delay-on de-energisation|| |with E-STOP typ.|**18 ms**| |with E-STOP max.|**30 ms**| |with power failure typ.|**18 ms**| |withpower failure max.|**30 ms**| |Supplyinterruption before de-energisation|**5 ms**| |**Environmental data**|| |EMC|**EN 60947-5-1**, **EN 61000-6-2**, **EN 61000-6-4**| |Vibration to**EN 60068-2-6**|| |Frequency|**10.0 - 55.0 Hz**| |Amplitude|**0.35 mm**| |Climatic suitability|**EN 60068-2-78**| |Airgap creepage in accordance with**EN 60947-1**|| |Pollution degree|**2**| |Overvoltage category|**III**| |Rated insulation voltage|**250 V**| |Rated impulse withstand voltage|**6.00 kV**| |Ambient temperature|**-10 - 55 °C**| |Storage temperature|**-40 - 85 °C**| |Protection type|| |Mounting (e.g. cabinet)|**IP54**| |Housing|**IP40**| |Terminals|**IP20**| Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de 1001988-EN-05-2012-11 Contact expansions **==> picture [72 x 42] intentionally omitted <==** ## **Up to PL e of EN ISO 13849-1** PNOZ s7.1 ## **Mechanical data** Housing material Housing Front **PC PC** Cross section of external conductors with screw terminals 1 core flexible 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve without crimp connectors or with TWIN crimp connectors Torque setting with screw terminals **0.25 - 2.50 mm² , 24 - 12 AWG** No. 750167 **0.25 - 1.00 mm² , 24 - 16 AWG** No. 750167 **0.20 - 1.50 mm² , 24 - 16 AWG** No. 750167 **0.50 Nm** No. 750167 **0.20 - 2.50 mm² , 24 - 12 AWG** No. 751167 Cross section of external conductors with spring-loaded terminals: Flexible with/without crimp connectors Spring-loaded terminals: Terminal points per connection **2** No. 751167 Stripping length **9 mm** No. 751167 Dimensions Height **100.0 mm** No. 751167 **98.0 mm** No. 750167 Width **17.5 mm** Depth **120.0 mm** Technische DatenWei_Satz No.ght **170 g** No. stands for order number. Si-Kennzahlen_Zusatz_Relais_Lebensdauer_PDBIt is essential to consider the relay's service life graphs. The relay outputs' safety-related characteristic data is only valid if the values in the service life graphs are met. The PFH value depends on the switching frequency and the load on the relay output. If the service life graphs are not accessible, the stated PFH value can be used irrespective of the switching frequency and the load, as the PFH value already considers the relay's B10d value as well as the failure rates of the other components. All the units used within a safety function must be considered when calculating the safety characteristic data. ## Si_Kennzahlen_Erläuterung_2 **INFORMATION** A safety function's SIL/PL values are **not** identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. The standards current on **2007-10** apply. ## **Conventional thermal current while loading several contacts** |Number of contacts|Ithper contact at UB DC| |---|---| |1|**6.00 A**| |2|**5.50 A**| |3|**4.50 A**| ## **Order reference** |**Type**||**Features**|||**Terminals**|**Order no.**| |---|---|---|---|---|---|---| |PNOZ s7.1|C||24|VDC|With spring-loaded terminals|751 167| |PNOZ s7.1|||24|VDC|With screw terminals|750 167| Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de 1001988-EN-05-2012-11
Updated at June 7, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →