750102
Safety Relay, 24 VDC, 3PST-NO, DIN Rail, 6 A, Screw
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: PILZ
- Product type: Safety Relays
- Coil Voltage:24VDC; Contact Configuration:3PST-NO; Product Range:PNOZ s2 Series; Relay Mounting:DIN Rail; Contact Current:6A; Relay Terminals:Screw; Contact Voltage AC Nom:240V; Contac
- SVHC: No SVHC (04-Feb-2026)
- IP Rating: IP20, IP40, IP54
- Coil Voltage: 24VDC
- Product Range: -
- Relay Mounting: DIN Rail
- Contact Current: 6A
- Relay Terminals: Screw
- Contact Material: Silver Copper Nickel
- Contact Configuration: 3PST-NO
- Contact Voltage AC Nom: 240V
- Contact Voltage DC Nom: 24V
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 176.16 € |
| Current stock | 10+ |
| Lead time | 30 days |
E-STOP relays, safety gate monitors
## **Up to PL e of EN ISO 13849-1** PNOZ s2
## **Unit features**
- Gertemerkmale Positive-guided relay outputs:
- 3 safety contacts (N/O), instantaneous
- 1 auxiliary contact (N/C), instantaneous
- Safe separation of safety contacts from all other circuits
- 1 semiconductor output
## **Unit description**
Bestimmung/Gerätebeschreibung NOT-AUS, Schutz_PNOZThe safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with
- E-STOP pushbuttons
- Safety gates
## **Safety features**
- Connection options for:
- E-STOP pushbutton
- Safety gate limit switch
][BildunterschriftSafety relay for monitoring E-STOP pushbuttons and safety gates.
- Reset button
- A connector can be used to connect 1 PNOZsigma contact expander module
## **Approvals**
- Operating modes can be set via rotary switch
**==> picture [231 x 111] intentionally omitted <==**
**----- Start of picture text -----**<br>
PNOZ s2 LED indicator for:<br> Supply voltage<br> Input status, channel 1<br><br> Input status, channel 2<br> Switch status, safety contacts<br> Reset circuit<br><br> Error<br> Plug-in connection terminals (either<br>spring-loaded terminal or screw<br><br>terminal)<br>**----- End of picture text -----**<br>
][Sicherheitseigenschaften Schaltgerät_allgemeiner TeilThe relay meets the following safety requirements:
- The circuit is redundant with built-in self-monitoring.
- The safety function remains effective in the case of a component failure.
- The correct opening and closing of the safety function relays is tested automatically in each on-off cycle.
- Sicherheitseigenschaften Zusatz - Sicherung DC_PNOZ The unit has an electronic fuse.
- Gertemerkmale See order reference for unit types
## **Block diagram**
**==> picture [3 x 3] intentionally omitted <==**
**----- Start of picture text -----**<br>
B l o c kshatbild<br>**----- End of picture text -----**<br>
- Safe separation in accordance with EN 60947-1, 6 kV
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
1001968-EN-03-2011-11
E-STOP relays, safety gate monitors
**==> picture [72 x 42] intentionally omitted <==**
## **Up to PL e of EN ISO 13849-1** PNOZ s2
- ][Funktionen_berStart_fall_Flanke Monitored reset with falling edge: Unit is active once
## **Function description**
- ][Funktionen_einkanalig Single-channel operation: no redundancy in the input circuit, earth faults in the reset and input circuit are detected.
- the input circuit is closed and then the reset circuit is closed and opened again.
- the reset circuit is closed and then opened again once the input circuit is closed.
- ][Funktionen_autoStart Automatic start: Unit is active once the input circuit has been closed.
- ][Funktionen_manuStart Manual reset: Unit is active once ][Funktionen_berStart_steig_Flanke Monitored reset with rising edge: the input circuit is closed and then Unit is active once the input circuit the reset circuit is closed. is closed and once the reset circuit
is closed after the waiting period has elapsed (see technical details).
- ][Funktionen_Kontaktvervielfachung_PNOZsigma Increase in the number of available instantaneous safety contacts by connecting contact expander modules or external contactors/relays; A connector can be used to connect 1 PNOZsigma contact expander module.
## **Timing diagram**
**==> picture [483 x 113] intentionally omitted <==**
**----- Start of picture text -----**<br>
rmnZeit d abu PNOsIUo12xS _ ][g<br>� � � �<br>� � � � � �<br>�����������<br>�����������<br>�����������<br>�����������<br>��������<br>�� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� ��<br>**----- End of picture text -----**<br>
## **Key**
- Power: Supply voltage
- Reset/Start: Reset circuit S34
- Input: Input circuits A1-A2
- Output safe: Safety contacts 13-14, 23-24, 33-34
- Output aux: Auxiliary contacts 4142
- Out semi: Semiconductor outputY32
- : Automatic reset
- : Manual reset
- : Monitored reset with rising edge
- : Monitored reset with falling edge
- a: Input circuit closes before reset circuit
- b: Reset circuit closes before input circuit
- t1: Switch-on delay
- t2: Delay-on de-energisation
- t3: Waiting period
- t4: Waiting period reset circuit was closed
## **Wiring**
][Verdrahtung_Si_unverz_1Hi_unverzPlease note:
- Information given in the “Technical details” must be followed.
- Outputs 13-14, 23-24, 33-34 are safety contacts, output 41-42 is an auxiliary contact (e.g. for display).
- Use copper wire that can withstand 60/75 °C.
- Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads.
- To prevent contact welding, a fuse should be connected before the output contacts (see technical details).
- Calculation of the max. cable runs lmax in the input circuit:
- �����
- ������
������� Rlmax = max. overall cable resistance (see technical details) Rl /km = cable resistance/km
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
1001968-EN-03-2011-11
E-STOP relays, safety gate monitors
## **Up to PL e of EN ISO 13849-1** PNOZ s2
## **Preparing for operation**
- Supply voltage
**==> picture [334 x 8] intentionally omitted <==**
**----- Start of picture text -----**<br>
Supply voltage AC DC<br>**----- End of picture text -----**<br>
- Input circuit
**==> picture [370 x 104] intentionally omitted <==**
**----- Start of picture text -----**<br>
Input circuit Single-channel Dual-channel<br>E-STOP p----------= $1<br>without detection of shorts across con- A1 L+<br>tacts<br>| I<br>| I<br>| I<br>|<br>Safety gate Ge)<br>without detection of shorts across con-<br>tacts L— 7.<br>**----- End of picture text -----**<br>
- Reset circuit/feedback loop
**==> picture [382 x 92] intentionally omitted <==**
**----- Start of picture text -----**<br>
Reset circuit/feedback loop Reset circuit Feedback circuit<br>Automatic reset ry<br>cr<br>Al '<br>1I eoccccro-s| !I<br>1 ! ; 13<br>I | 44<br>Io LL<br>Manual/monitored reset<br>**----- End of picture text -----**<br>
- Semiconductor output
*Connect together the 0V connections on all the external power supplies
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
1001968-EN-03-2011-11
E-STOP relays, safety gate monitors
## **Up to PL e of EN ISO 13849-1** PNOZ s2
## Key
- S1 E-STOP pushbutton
- S3 Reset button
- Gate open
Gate closed
## ][Betriebsbereitschaft_herstellen_Info_Grundgert_DB **INFORMATION**
If a base unit and a contact expansion module from the PNOZsigma range are linked via the connector, no additional wiring is necessary.
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
1001968-EN-03-2011-11
E-STOP relays, safety gate monitors
**==> picture [72 x 42] intentionally omitted <==**
## **Up to PL e of EN ISO 13849-1** PNOZ s2
## **Terminal configuration**
**==> picture [316 x 212] intentionally omitted <==**
**----- Start of picture text -----**<br>
K nlem bu g<br>**----- End of picture text -----**<br>
## **Installation**
## **Dimensions**
> ][Montage_PNOZsigma **Install base unit without contact ex-** Abmessungen*with spring-loaded terminals
## ][Montage_PNOZsigma **Install base unit without contact expander module:**
**==> picture [131 x 151] intentionally omitted <==**
**----- Start of picture text -----**<br>
����������<br>����<br>������������� �������<br>������������<br>**----- End of picture text -----**<br>
- Ensure that the plug terminator is inserted at the side of the unit.
## **Connect base unit and PNOZsigma contact expander module:**
- Remove the plug terminator at the side of the base unit and at the contact expander module.
- Connect the base unit and the contact expander module to the supplied connector before mounting the units to the DIN rail.
## **Installation in control cabinet**
- The safety relay should be installed in a control cabinet with a protection type of at least IP54.
- Use the notch on the rear of the unit to attach it to a DIN rail (35 mm).
- When installed vertically: Secure the unit by using a fixing element (e.g. retaining brakket or end angle).
- Push the unit upwards or downwards before lifting it from the DIN rail.
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
1001968-EN-03-2011-11
## E-STOP relays, safety gate monitors
## **Up to PL e of EN ISO 13849-1** PNOZ s2
## **Notice**
][Wichtig_PDBThis data sheet is only intended for use during configuration. Please refer to the operating manual for installation and operation.
## **Service life graph**
Lebensdauerkurve_Relais_Text vor KurveThe service life graphs indicate the Lkv **e** bnsda **ur** number of cycles from which failures fo}Oo due to wear must be expected. The oO wear is mainly caused by the electrical xog 10000 -SSa SS RS load; the mechanical load is negligible.
> Lebensdauerkurve_Relais_Text nach Kurve_SIF Bsp **Example**
- Inductive load: 0,2 A
- Utilisation category: AC15
- Contact service life: 2,000,000 cycles
Provided the application requires fewer than 2,000,000 cycles, the PFH value (see technical details) can be used in the calculation.
To increase the service life, sufficient spark suppression must be provided on all output contacts. With capacitive loads, any power surges that occur must be noted. With contactors, use freewheel diodes for spark suppression.
|**Technical details**||
|---|---|
|||
|**Electrical data**||
|Supply voltage||
|Supplyvoltage UB DC|**24 V**|
|Voltage tolerance|**-15 %/+10 %**|
|Power consumption at UB DC|**2.0 W**|
|Residual ripple DC|**20 %**|
|Voltage and current at||
|Input circuit DC:**24.0 V**|**75.0 mA**|
|Reset circuit DC:**24.0 V**|**7.0 mA**|
|Feedback loopDC:**24.0 V**|**7.0 mA**|
|Number of output contacts||
|Safety contacts (S) instantaneous:|**3**|
|Auxiliarycontacts(N/C):|**1**|
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
1001968-EN-03-2011-11
E-STOP relays, safety gate monitors
**==> picture [72 x 42] intentionally omitted <==**
## **Up to PL e of EN ISO 13849-1** PNOZ s2
## **Electrical data**
Utilisation category in accordance with **EN 60947-4-1** Safety contacts: AC1 at **240 V**
|Utilisation category in accordance with**EN 60947-4-1**<br>||
|---|---|
|Safety contacts: AC1 at**240 V**|Imin:**0.01 A**, Imax:**6.0 A**|
||Pmax:**1500 VA**|
|Safety contacts: DC1 at**24 V**|Imin:**0.01 A**, Imax:**6.0 A**|
||Pmax:**150 W**|
|Auxiliary contacts: AC1 at**240 V**|Imin:**0.01 A**, Imax:**6.0 A**|
||Pmax:**1500 VA**|
|Auxiliary contacts: DC1 at**24 V**|Imin:**0.01 A**, Imax:**6.0 A**|
||Pmax:**150 W**|
|Utilisation category in accordance with**EN 60947-5-1**||
|Safety contacts: AC15 at**230 V**|Imax:**5.0 A**|
|Safety contacts: DC13 at**24 V**(6 cycles/min)|Imax:**5.0 A**|
|Auxiliary contacts: AC15 at**230 V**|Imax:**5.0 A**|
|Auxiliarycontacts: DC13 at**24 V** (6 cycles/min)|Imax:**5.0 A**|
|Contact material|**AgCuNi + 0.2µm Au**|
|External contact fuse protection (IK= 1 kA) to**EN 60947-5-1**||
|Blow-out fuse, quick||
|Safety contacts:|**10 A**|
|Auxiliary contacts:|**10 A**|
|Blow-out fuse, slow||
|Safety contacts:|**6 A**|
|Auxiliary contacts:|**6 A**|
|Circuit breaker 24 VAC/DC, characteristic B/C||
|Safety contacts:|**6 A**|
|Auxiliarycontacts:|**6 A**|
|Semiconductor outputs(short circuitproof)|**24.0 V**DC,**20 mA**|
|Max. overall cable resistance Rlmax||
|input circuits, reset circuits||
|single-channel at UB DC|**30 Ohm**|
|**Safety-related characteristic data**||
|PL in accordance with**EN ISO 13849-1: 2006**|**PL e** (**Cat. 4**)|
|Categoryin accordance with**EN 954-1**|**Cat. 4**|
|SIL CL in accordance with**EN IEC 62061**|**SIL CL 3**|
|PFH in accordance with**EN IEC 62061**|**2.50E-09**|
|SIL in accordance with**IEC 61511**|**SIL 3**|
|PFD in accordance with**IEC 61511**|**2.13E-05**|
|TM [year]in accordance with**EN ISO 13849-1: 2006**|**20**|
|**Times**||
|Switch-on delay||
|with automatic reset typ.|**75 ms**|
|with automatic reset max.|**250 ms**|
|with automatic reset after power on typ.|**75 ms**|
|with automatic reset after power on max.|**250 ms**|
|with manual reset typ.|**75 ms**|
|with manual reset max.|**250 ms**|
|on monitored reset with rising edge typ.|**75 ms**|
|on monitored reset with rising edge max.|**250 ms**|
|on monitored reset with falling edge typ.|**55 ms**|
|on monitored reset with fallingedge max.|**70 ms**|
|Delay-on de-energisation||
|with E-STOP typ.|**50 ms**|
|with E-STOP max.|**70 ms**|
|with power failure typ.|**50 ms**|
|withpower failure max.|**70 ms**|
|Recovery time at max. switching frequency 1/s||
|after E-STOP|**100 ms**|
|afterpower failure|**100 ms**|
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
1001968-EN-03-2011-11
E-STOP relays, safety gate monitors
**==> picture [72 x 42] intentionally omitted <==**
## **Up to PL e of EN ISO 13849-1** PNOZ s2
## **Times**
Waiting period with a monitored reset with rising edge **100 ms** with falling edge **110 ms** Min. start pulse duration with a monitored reset with rising edge **100 ms** with falling edge **100 ms** Supply interruption before de-energisation **10 ms Environmental data** EMC **EN 60947-5-1** , **EN 61000-6-2** , **EN 61000-6-4** Vibration to **EN 60068-2-6** Frequency **10 - 55 Hz** Amplitude **0.35 mm** Climatic suitability **EN 60068-2-78** Airgap creepage in accordance with **EN 60947-1** Pollution degree **2** Overvoltage category **III** Rated insulation voltage **250 V** Rated impulse withstand voltage **6.00 kV** Ambient temperature **-10 - 55 °C** Storage temperature **-40 - 85 °C** Protection type Mounting (e.g. cabinet) **IP54** Housing **IP40** Terminals **IP20 Mechanical data** Housing material Housing **PC** Front **PC** Cross section of external conductors with screw terminals 1 core flexible **0.25 - 2.50 mm² , 24 - 12 AWG** No. 750102 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve **0.25 - 1.00 mm² , 24 - 16 AWG** No. 750102 without crimp connectors or with TWIN crimp connectors **0.20 - 1.50 mm² , 24 - 16 AWG** No. 750102 Torque setting with screw terminals **0.50 Nm** No. 750102 Cross section of external conductors with spring-loaded termi- **0.20 - 2.50 mm² , 24 - 12 AWG** No. 751102 nals: Flexible with/without crimp connectors Spring-loaded terminals: Terminal points per connection **2** No. 751102 Stripping length **9 mm** No. 751102 Dimensions Height **102.0 mm** No. 751102
**102.0 mm** No. 751102 **96.0 mm** No. 750102 **17.5 mm 120.0 mm 170 g**
Width Depth Weight
Technische Daten_Satz No.
## No. stands for order number.
Si-Kennzahlen_Zusatz_Relais_Lebensdauer_PDBIt is essential to consider the relay's service life graphs. The relay outputs' safety-related characteristic data is only valid if the values in the service life graphs are met.
The PFH value depends on the switching frequency and the load on the relay output. If the service life graphs are not accessible, the stated PFH value can be
used irrespective of the switching frequency and the load, as the PFH value already considers the relay's B10d value as well as the failure rates of the other components.
All the units used within a safety function must be considered when calculating the safety characteristic data.
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
1001968-EN-03-2011-11
E-STOP relays, safety gate monitors
**==> picture [72 x 42] intentionally omitted <==**
## **Up to PL e of EN ISO 13849-1** PNOZ s2
## **INFORMATION**
A safety function's SIL/PL values are **not** identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values.
The standards current on **2006-04** apply.
## **Conventional thermal current while loading several contacts**
Number of contacts Ith per contact at UB DC 1 **6.00 A** 2 **6.00 A** 3 **5.00 A**
**Order reference Type Features Terminals Order no.** PNOZ s2 24 VDC With screw terminal 750 102 PNOZ s2 C 24 VDC With spring-loaded terminal 751 102
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
1001968-EN-03-2011-11
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →