Image not available
Illustrative purposes only
750101
Safety Relay, 24 VDC, DPST-NO, DIN Rail, 3 A, Screw
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: PILZ
- Product type: Safety Relays
- Coil Voltage:24VDC; Contact Configuration:DPST-NO; Product Range:PNOZ s1 Series; Relay Mounting:DIN Rail; Contact Current:3A; Relay Terminals:Screw; Contact Voltage AC Nom:240V; Contac
- SVHC: No SVHC (04-Feb-2026)
- IP Rating: IP20, IP40, IP54
- Coil Voltage: 24VDC
- Product Range: -
- Relay Mounting: DIN Rail
- Contact Current: 3A
- Relay Terminals: Screw
- Contact Material: Silver Tin Oxide
- Contact Configuration: DPST-NO
- Contact Voltage AC Nom: 240V
- Contact Voltage DC Nom: 24V
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 146.41 € |
| Current stock | 10+ |
| Lead time | 30 days |
PNOZsigma - Base units G Register Login Sensors **Control and Communication** Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable safety and control systems Industrial communication Motion Control Operating and Monitoring Software G Back to overview ## **PNOZsigma - Base units** Safe monitoring of E-STOP, safety gate, light grid and two-hand control ## **PNOZ s1 24VDC 2 n/o Order numbers: 750101** - G Type: **PNOZ s1** - G Application options: **Safety gate monitor , Instantaneous E-STOP monitoring , Limit switch** - G Category in accordance with: **EN 954-1 , EN ISO 13849-1** - G SIL value: **--** - G Standards: **EN 60204-1 , EN 62061 , VDE 0113-1 , EN 954-1** - G Approvals: **BG , CCC , GOST Russia , UL/cUL** - G Operating modes: **Automatic start , Single-channel , Manual start** - G Selectable times: **--** - G Number of instantaneous safety contacts: **2** - G Number of delayed safety contacts: **--** - G Number of auxiliary contacts: **--** - G Number of delayed auxiliary contacts: **--** - G Number of semiconductor outputs: **1** - G Stop category: **0** - G Supply voltage [V]: **24** - G Supply voltage range: **--** - G Supply voltage type: **DC** - G Max. current at DC1: **3,0 A** - G Power consumption AC: **--** - G Power consumption DC: **--** - G Height dimension: **98,0 mm** - G Width dimension: **12,5 mm** - G Depth dimension: **120,0 mm** - G Height dimension (inches): **3.86"** - G Width dimension (inches): **0.49"** - G Depth dimension (inches): **4.72"** - G Gross weight: **150 g** - G Net weight: **105 g** - G Ambient temperature in °C: **-10 - 55 °C** - G Terminal type: **Screw terminal** G Terminal style: **Plug-in** - G Order number: **750101** http://www.pilz.co.uk/products/control_communication/safety_relay/f/pnozsigma/s/00514/index.jsp?itemId=750101 (1 of 2)24/02/2009 16:13:56 E-STOP relays, safety gate monitors ## **Up to PL c of EN ISO 13849-1** PNOZ s1 ## **Unit features** Relay outputs: - 2 safety contacts (N/O), instanta- and VDE 0113-1 and may be used in applications with E-STOP pushbuttons Safety gates neous Safety relay for monitoring E-STOP pushbuttons and safety gates. ## **Approvals** - 1 semiconductor output Connection options for: - E-STOP pushbutton - Safety gate limit switch - Reset button A connector can be used to connect 1 PNOZsigma contact expander module LED indicator for: - Supply voltage - Input status, channel 1 - Input status, channel 2 ## **Safety features** The relay meets the following safety requirements: > > The circuit is redundant with built-in self-monitoring. The safety function remains effective in the case of a component failure. The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. - ~~a~~ – Switch status, safety contacts » The unit has an electronic fuse. **==> picture [39 x 7] intentionally omitted <==** **----- Start of picture text -----**<br> PNOZ s1<br>**----- End of picture text -----**<br> - Reset circuit - Error - » Plug-in connection terminals (either spring-loaded terminal or screw terminal) ## **Unit description** The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 ## **Block diagram** Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de NSG-D-2-392-2008-11 E-STOP relays, safety gate monitors **==> picture [72 x 42] intentionally omitted <==** ## **Up to PL c of EN ISO 13849-1** PNOZ s1 ## **Function description** - Single-channel operation: no redundancy in the input circuit, earth faults in the reset and input circuit are detected. - Automatic start: Unit is active once the input circuit has been closed. - Manual reset: Unit is active once the input circuit is closed and then the reset circuit is closed. - Increase in the number of available instantaneous safety contacts by - connecting contact expander modules or external contactors/relays; A connector can be used to connect 1 PNOZsigma contact expander module. ## **Timing diagram** **==> picture [304 x 132] intentionally omitted <==** **----- Start of picture text -----**<br> � �<br>� �<br>�����<br>�����������<br>�����<br>�����������<br>����<br>�� �� �� �� �� �� �� ��<br>��<br>**----- End of picture text -----**<br> ## **Key** - Power: Supply voltage - Reset/Start: Reset circuit S34 - Input: Input circuits A1-A2 - Output safe: Safety contacts 13-14, 23-24 - Semi: Semiconductor outputY32 - � : Automatic reset - � : Manual reset - a: Input circuit closes before reset circuit - b: Reset circuit closes before input circuit - t1: Switch-on delay - t2: Delay-on de-energisation - t3: Recovery time ## **Wiring** Please note: - Information given in the “Technical details” must be followed. - Outputs 13-14, 23-24 are safety contacts. - To prevent contact welding, a fuse should be connected before the output contacts (see technical details). - Calculation of the max. cable runs lmax in the input circuit: - ������ - ����� - ������� Rlmax = max. overall cable resistance (see technical details) Rl /km = cable resistance/km - Use copper wire that can withstand 60/75 °C. - Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de NSG-D-2-392-2008-11 E-STOP relays, safety gate monitors ## **Up to PL c of EN ISO 13849-1** PNOZ s1 ## **Preparing for operation** ## Supply voltage **==> picture [370 x 218] intentionally omitted <==** **----- Start of picture text -----**<br> Supply voltage AC DC<br>I<br>|<br>Input circuit<br>Input circuit Single-channel Dual-channel<br>E-STOP rota aaaa SI<br>without detection of shorts across con- Al L+<br>I<br>tacts<br>;; I<br>; II<br>Iowa<br>Safety gate Mh<br>without detection of shorts across con-<br>tacts = i<br>**----- End of picture text -----**<br> ## Reset circuit **==> picture [376 x 257] intentionally omitted <==** **----- Start of picture text -----**<br> Reset circuit Reset circuit Feedback loop<br>Automatic reset<br>i COA<br>a.<br>! !<br>Manual reset<br>Ho 7]<br>! At I =<br>I i<br>Semiconductor output<br>proccccccccn<br>| Y3 20——— PLC Input<br>I<br>I-28<br>*Connect together the 0V connections on all the external power supplies<br>**----- End of picture text -----**<br> Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de NSG-D-2-392-2008-11 E-STOP relays, safety gate monitors ## **Up to PL c of EN ISO 13849-1** PNOZ s1 ## Key - S1 E-STOP pushbutton S3 Reset button Switch operated - Gate open - Gate closed ## **INFORMATION** If a base unit and a contact expansion module from the PNOZsigma range are linked via the connector, no additional wiring is necessary. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de NSG-D-2-392-2008-11 E-STOP relays, safety gate monitors **==> picture [72 x 42] intentionally omitted <==** ## **Up to PL c of EN ISO 13849-1** PNOZ s1 ## **Terminal configuration** ## **Installation** ## **Install base unit without contact expander module:** - Ensure that the plug terminator is inserted at the side of the unit. ## **Connect base unit and PNOZsigma contact expander module:** - Remove the plug terminator at the side of the base unit and at the contact expander module. - Connect the base unit and the contact expander module to the supplied connector before mounting the units to the DIN rail. ## **Installation in control cabinet** - The safety relay should be installed in a control cabinet with a protection type of at least IP54. ## **Dimensions** **==> picture [160 x 151] intentionally omitted <==** **----- Start of picture text -----**<br> �������������<br>����������<br>�������������<br>������������<br>**----- End of picture text -----**<br> - Use the notch on the rear of the unit to attach it to a DIN rail. - Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle). - Push the unit upwards or downwards before lifting it from the DIN rail. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de NSG-D-2-392-2008-11 E-STOP relays, safety gate monitors **==> picture [72 x 42] intentionally omitted <==** ## **Up to PL c of EN ISO 13849-1** PNOZ s1 ## **NOTICE** This data sheet is only intended for use erating instructions supplied with the during configuration. For installation unit. and operation, please refer to the op- |**Technical details**|| |---|---| ||| |**Electrical data**|| |Supply voltage|| |Supplyvoltage UB DC|**24 V**| |Voltage tolerance|**-15 %/+10 %**| |Power consumption at UB DC|**2.0 W**| |Residual ripple DC|**20 %**| |Voltage and current at|| |Input circuit DC:**24.0 V**|**60.0 mA**| |Reset circuit DC:**24.0 V**|**20.0 mA**| |Feedback loopDC:**24.0 V**|**20.0 mA**| |Number of output contacts|| |Safetycontacts(S)instantaneous:|**2**| |Utilisation category in accordance with**EN 60947-4-1**|| |Safety contacts: AC1 at**240 V**|Imin:**0.02 A**, Imax:**3.0 A**| ||Pmax:**720 VA**| |Safety contacts: DC1 at**24 V**|Imin:**0.02 A**, Imax:**3.0 A**| ||Pmax:**72 W**| |Utilisation category in accordance with**EN 60947-5-1**|| |Safety contacts: AC15 at**230 V**|Imax:**1.5 A**| |Safetycontacts: DC13 at**24 V** (6 cycles/min)|Imax:**1.5 A**| |Contact material|**AgSnO2**| |External contact fuse protection (IK= 1 kA) to**EN 60947-5-1**|| |Blow-out fuse, quick|| |Safety contacts:|**4 A**| |Blow-out fuse, slow|| |Safety contacts:|**2 A**| |Circuit breaker 24 VAC/DC, characteristic B/C|| |Safetycontacts:|**2 A**| |Semiconductor outputs(short circuitproof)|**24.0 V**DC,**20 mA**| |Max. overall cable resistance Rlmax|| |input circuits, reset circuits|| |single-channel at UB DC|**30 Ohm**| |**Safety-related characteristic data**|| |**Performance level (PL)**in accordance with**EN ISO 13849-1**|| |Safetycontacts,instantaneous|**c**| |**Category**of output contacts in accordance with**EN 954-1**,|| |**EN ISO 13849-1**|| |Safetycontacts(S)instantaneous:|**2**| |**SIL claim limit (SIL CL)**in accordance with**EN IEC 62061**|| |Safetycontacts,instantaneous|**2**| |Probability of dangerous failure per hour**(PFH**D**)**in accordance|| |with**EN IEC 62061**|| |Safetycontacts,instantaneous|**2.00E-07 1/h**| |Mission time/Proof test interval inyears|**20**| Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de NSG-D-2-392-2008-11 E-STOP relays, safety gate monitors **==> picture [72 x 42] intentionally omitted <==** ## **Up to PL c of EN ISO 13849-1** PNOZ s1 |**Times**|| |---|---| |Switch-on delay|| |with automatic reset typ.|**100 ms**| |with automatic reset max.|**150 ms**| |with automatic reset after power on typ.|**100 ms**| |with automatic reset after power on max.|**150 ms**| |with manual reset typ.|**50 ms**| |with manual reset max.|**60 ms**| |Delay-on de-energisation|| |with E-STOP typ.|**30 ms**| |with E-STOP max.|**40 ms**| |with power failure typ.|**30 ms**| |withpower failure max.|**40 ms**| |Recovery time at max. switching frequency 1/s|| |after E-STOP|**100 ms**| |afterpower failure|**100 ms**| |Supplyinterruption before de-energisation|**10 ms**| |**Environmental data**|| |EMC|**EN 60947-5-1**, **EN 61000-6-2**, **EN 61000-6-4**| |Vibration to**EN 60068-2-6**|| |Frequency|**10 - 55 Hz**| |Amplitude|**0.35 mm**| |Climatic suitability|**EN 60068-2-78**| |Airgap creepage in accordance with**EN 60947-1**|| |Pollution degree|**2**| |Rated insulation voltage|**250 V**| |Rated impulse withstand voltage|**4.0 kV**| |Ambient temperature|**-10 - 55 °C**| |Storage temperature|**-40 - 85 °C**| |Protection type|| |Mounting (e.g. cabinet)|**IP54**| |Housing|**IP40**| |Terminals|**IP20**| |**Mechanical data**|| |Housing material|| |Housing|**PC**| |Front|**PC**| |Cross section of external conductors with screw terminals|| |1 core flexible|**0.25 - 2.50 mm² , 24 - 12 AWG**Order no.: 750101| |2 core, same cross section, flexible:|| |with crimp connectors, without insulating sleeve|**0.25 - 1.00 mm² , 24 - 16 AWG**Order no.: 750101| |without crimpconnectors or with TWIN crimpconnectors|**0.20 - 1.50 mm², 24 - 16 AWG**Order no.: 750101| |Torque settingwith screw terminals|**0.50 Nm**Order no.: 750101| |Cross section of external conductors with spring-loaded termi-|**0.20 - 2.50 mm² , 24 - 12 AWG**Order no.: 751101| |nals: Flexible with/without crimpconnectors|| |Spring-loaded terminals: Terminal points per connection|**2**Order no.: 751101| |Strippinglength|**9 mm**Order no.: 751101| |Dimensions|| |Height|**100.0 mm**Order no.: 751101| ||**98.0 mm**Order no.: 750101| |Width|**12.5 mm**| |Depth|**120.0 mm**| |Weight|**105g**| The standards current on **2006-04** apply. Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de NSG-D-2-392-2008-11 ## E-STOP relays, safety gate monitors **==> picture [72 x 42] intentionally omitted <==** ## **Up to PL c of EN ISO 13849-1** PNOZ s1 ## **Conventional thermal current** |Ith (A)at UB DC|| |---|---| |1 contact|**3.00 A**| |2 contacts|**3.00 A**| ## **Order reference** |**Type**||**Features**|||**Terminals**|**Order no.**| |---|---|---|---|---|---|---| |PNOZ s1|||24|VDC|With screw terminal|750 101| |PNOZ s1|C||24|VDC|With spring-loaded terminal|751 101| Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de NSG-D-2-392-2008-11
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →