Image not available
Illustrative purposes only
745691-02
RTD Sensor, 2 m, Probe, -50 °C, 204 °C, 100 ohm, Platinum
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: NI / EMERSON
- Product type: RTD Temperature Sensors
- SVHC: To Be Advised
- RTD Type: Probe
- Resistance: 100ohm
- Probe Length: -
- RTD Accuracy: -
- Product Range: -
- Probe Diameter: -
- Probe Material: -
- Cable Termination: Wire Leaded
- Resistance @ 0°C: 100ohm
- Wire Configuration: 3-Wire
- RTD Element Material: Platinum
- Cable Length - Metric: 2m
- Cable Length - Imperial: 6.6ft
- Sensing Temperature Min: -50°C
- Measured Temperature Max: 204°C
- Measured Temperature Min: -50°C
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 65.25 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **Thermocouple and RTD Sensors** ## **Thermocouples** - J, K, T, and E types ## **Accessories** - Thermocouple plugs (J, K, T, E) ## **RTDs** - Platinum 100 Ω at 0 °C - Conform to DIN 43760-1980 (alpha = 0.00385) - Spring-loaded fittings (probes only) - Tubing cutters (probes only) - 3-wire ## **Configuration Options** - Field-cuttable probes - Ready-made sensors - Thermocouple wire - Thermocouple extension wire ## **Overview** NI offers thermocouples and RTDs for your measurement and automation systems. These sensors are available in versatile configurations – field-cuttable probes and ready-made sensors. NI also offers spools of thermocouple wire and extension wire. ## **Thermocouples** Thermocouples are the most popular temperature measurement transducers available. Because of their low cost and wide temperature acceptance range, you can use thermocouples for a wide variety of applications in all industries. All NI thermocouples and extension wires are available in J, K, T, and E types and follow ANSI color coding specifications. ## **INFO CODES** ## **Thermocouple Miniconnector Plugs** For more information, or to order products online visit _**ni.com/info**_ and enter: For applications requiring fast, easy connection and disconnection of thermocouples, we suggest thermocouple miniconnectors. These plugs work with any standard thermocouple miniconnector jack, including those available with the TC-2095, SCXI-1112, ~~tempsensors~~ ## _**BUY ONLINE!**_ SC-2311, SC-2345, and CA-1000 Series connector panelettes. Thermocouple miniconnector plugs come in quantities of 10, and are available for J, K, T, and E types. ## **RTDs** ## **Field-Cuttable Thermocouples** NI field-cuttable thermocouples suit a wide variety of temperature applications. With field-cuttable thermocouples, you can cut the metal sheathed probe to the desired length – from 8.9 to 61 cm (3.5 to 24 in.) RTDs are popular for high-accuracy temperature measurement applications. NI offers 3-wire, 100 Ω platinum RTDs that conform to the DIN 43760-1980 (European) standard curve (a = 0.00385). These RTDs are available as field-cuttable metal sheathed probes and ready-made element configurations. ## **Ready-Made Thermocouples** For cost-sensitive applications, NI offers ready-made thermocouples – individual packets of thermocouple wire with the measuring junction provided at one end. Ready-made thermocouples are ideal for starter or educational applications. ## **Field-Cuttable RTDs** NI field-cuttable RTDs are ideal for a wide variety of temperature applications. With field-cuttable RTDs, you can cut the metal sheathed probe to the desired length – from 8.9 to 61 cm (3.5 to 24 in.). ## **Ready-Made RTDs** ## **Thermocouple and Extension Wire** For large-scale or custom temperature measurement applications, NI offers spools of thermocouple and extension wire. You are responsible for making the thermocouple junction. Ready-made RTDs offer solutions for cost-sensitive temperature measurement applications. Each RTD element is sealed in an Alumina tube, with three Teflon-coated leads, and can measure up to 204 °C (400 °F). **350** National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com ## **Thermocouple and RTD Sensors** **==> picture [478 x 434] intentionally omitted <==** **----- Start of picture text -----**<br> Ordering Information T-type<br>Field-Cuttable Thermocouples 30 m ............................................................745687-T030<br>J-type 300 m ..........................................................745687-T300<br>Grounded........................................................745685-J01 E-type<br>Ungrounded....................................................745685-J02 30 m ............................................................745687-E030<br>K-type 300 m ..........................................................745687-E300<br>Grounded........................................................745685-K01 Thermocouple Extension Wire<br>Ungrounded....................................................745685-K02 Jx-type<br>T-type 30 m ............................................................745689-J030<br>Grounded........................................................745685-T01 300 m ..........................................................745689-J300<br>Ungrounded....................................................745685-T02 Kx-type<br>E-type 30 m ............................................................745689-K030<br>Grounded........................................................745685-E01 300 m ..........................................................745689-K300<br>Ungrounded....................................................745685-E02 Tx-type<br>Ready-Made Thermocouples 30 m ............................................................745689-T030<br>J-type 300 m ..........................................................745689-T300<br>1 m ..............................................................745690-J001 Ex-type<br>2 m ..............................................................745690-J002 30 m ............................................................745689-E030<br>K-type 300 m ..........................................................745689-E300<br>1 m ..............................................................745690-K001 Accessories<br>2 m ..............................................................745690-K002 Thermocouple Miniconnector Plugs (Quantity 10)<br>T-type J type..............................................................745688-J10<br>1 m ..............................................................745690-T001 K type ............................................................745688-K10<br>2 m ..............................................................745690-T002 T type ............................................................745688-T10<br>E-type E type ............................................................745688-E10<br>1 m ..............................................................745690-E001 Uncompensated ................................................745688-U10<br>2 m ..............................................................745690-E002 Spring-loaded fitting..............................................745688-32<br>Thermocouple Wire Tubing cutter ........................................................745688-37<br>J-type RTDs<br>30 m ............................................................745687-J030 Field-Cuttable RTD<br>300 m ..........................................................745687-J300 100 Ω, Pt, 3-wire ..............................................745686-01<br>K-type Ready-Made RTDs<br>30 m ............................................................745687-K030 1 m ..................................................................745691-01<br>300 m ..........................................................745687-K300 2 m ..................................................................745691-02<br>**----- End of picture text -----**<br> **==> picture [36 x 79] intentionally omitted <==** ## **Specifications** |**Thermocouple Characteristics**<br>**Extension Wire**<br>Temperature range..................................... -20 to 221 °F (-6.7 to 105 °C)<br>**RTD Characteristics**<br>Type ........................................................... Platinum<br>Resistance ................................................. 100Ωat 0 °C<br>Probe range ............................................... -58 to 900 °F (-50 to 482 °C)<br>Ready-made range..................................... -58 to 400 °F (-50 to 204 °C)<br>Calibration .................................................. DIN 43760-1980 (European) Standard<br>Curve (a = 0.00385)<br>Accuracy .................................................... ±(0.3+0.005 |t|) °C (where t is the<br>absolute valueof the temperature<br>being measured in °C)<br>Confguration.............................................. 3-wire<br>Probe and Ready-Made Thermocouple Calibrations|**Calibration**|**Conductor**|**Conductor**|**Temp. Range**|**Limits of Error1**<br>**(whichever is greater)**| |---|---|---|---|---|---| |||**Positive**|**Negative**||| ||J-type|Iron<br>(White)|Constantan<br>(Red)|32 to 900 °F<br>(0 to 482°C)|±2.2 °C (4.0 °F)<br>or ±0.75%| ||K-type|Chromel<br>(Yellow)|Alumael<br>(Red)|32 to 900 °F<br>(0 to 482°C)|±2.2 °C (4.0 °F)<br>or ±0.75%| ||T-type<br>(probe only)|Copper<br>(Blue)|Constantan<br>(Red)|-328 to 32 °F<br>(-200 to 0 °C)<br>32 to 500 °F<br>(0 to 260°C)|±2.2 °C (4.0 °F)<br>or ±0.75%<br>±1.0 °C (2.0 °F)<br>or ±0.75%| ||T-type (ready-<br>made only)|Copper<br>(Blue)|Constantan<br>(Red)|32 to 500 °F<br>(0 to 260°C)|±1.0 °C (2.0 °F)<br>or ±0.75%| ||E-type|Chromel<br>(Purple)|Constantan<br>(Red)|32 to 900 °F<br>(0 to 482 °C)|±1.7 °C (2.0 °F)<br>or ±0.75%| Probe and Ready-Made Thermocouple Calibrations 1Where error is given in percent, the percentage applies to the temperature being measured, not the range. National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni.com • ni.com **351**
Updated at June 5, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →