Image not available
Illustrative purposes only
731103
Time Counter, 8 Digit, 7 mm, Battery Powered, tico 731 Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: HENGSTLER
- Product type:
- SVHC: No SVHC (07-Jul-2017)
- Digit Height: 7mm
- Product Range: tico 731 Series
- Panel Cutout Width: 45mm
- Supply Voltage Max: -
- Supply Voltage Min: -
- Panel Cutout Height: 22mm
- No. of Digits / Alpha: 8
- Operating Temperature Max: 50°C
- Operating Temperature Min: -10°C
| Delivery and price | |
|---|---|
| Units per pack | 10 |
| Price | 49.34 € |
| Current stock | 10+ |
| Lead time | 30 days |
## **tico 731** ## ~~**Flexible Counter Series**~~ ## **in DIN size 24 x 48 mm** high contrast 8-digit LCD display or brilliant 6-digit LED display different supply voltages available: – independent of mains supply with lithium battery or – maintenance-free and environmentally friendly with 12-24 VDC supply also high-voltage input 12-250 VAC/VDC up to 8 different functions for each standard model: 01 Pulse counter 02 Tachometer (1/min) 03 Time counter (display in hhhh:mm:ss) 04 Time counter (display in hhhhhh,hh) 06 Bidirectional position indicator 07 Counter with differential mode ## **OVERVIEW** |~~**Standard Models**~~||~~**Type 1**~~|~~**Type 1**~~||~~**Type 2**~~|~~**Type 2**~~|~~**Type 2**~~||~~**Type 3**~~|~~**Type 4**~~|~~**Type 4**~~|~~**Type 4**~~||~~**Type 5**~~|~~**Type 5**~~|~~**Type 5**~~| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |||||||||||||||||| |~~**Hardware**~~||||||||||||||||| |~~Display~~||~~8-digit LCD~~|||~~8-digit LCD~~||||~~8-digit LCD~~|~~8-digit LCD~~||||~~6-digit LED~~||| |~~Supply voltage~~||~~Lithium battery~~|||~~12~~||~~12– 24 VDC~~||~~Lithium battery~~|~~12~~||~~12– 24 VDC~~||~~12~~||~~12– 24 VDC~~| |~~Nominal data~~||~~7years~~|||~~NV-FRAM~~||||~~7years~~|~~NV-Fram~~||||~~NV-Fram~~||| |~~n~~<br>~~oit~~<br>~~n~~<br>~~eter~~|||||~~1~~<br>~~>~~|~~sra~~<br>~~e~~<br>~~y 0~~<br>~~1~~||||~~1~~<br>~~>~~|~~sra~~<br>~~e~~<br>~~y 0~~<br>~~1~~|||~~1~~<br>~~>~~|~~sra~~<br>~~e~~<br>~~y 0~~<br>~~1~~|| |~~Active edge~~||~~x~~|||~~x~~||||~~x~~|~~x~~||||~~x~~||| |~~negative orpositive~~||||||||||||||||| |~~edge programmable~~||||||||||||||||| |~~Amplitude thresholds~~||~~< 0.7 and~~|||~~< 0.7 and~~|~~< 0.7 and~~|||~~< 3 V and~~|~~< 0.7 and~~|~~< 0.7 and~~|||~~< 0.7 and~~|~~< 0.7 and~~|| |||~~> 5 V, max. 30 V DC~~||~~max. 30 V DC~~|~~> 5 V~~|~~> 5 V, max. 30 V DC~~||~~max. 30 V DC~~|~~> 12 V~~|~~> 5 V~~|~~> 5 V, max. 30 V DC~~||~~max. 30 V DC~~|~~> 5 V~~|~~> 5 V, max. 30 V DC~~|| ||||||||||~~max. 250 V DC/AC~~|||||||| |~~Counting frequency~~||~~max. 7.5 kHz or~~|||~~max. 7.5 kHz or~~||||~~20 Hz~~|~~max. 7.5 kHz or~~||||~~max. 7.5 kHz or~~||| |~~elb~~<br>~~a~~<br>~~m~~<br>~~m~~<br>~~arg~~<br>~~orp~~||~~0~~<br>~~3~~|~~d~~<br>~~eta~~<br>~~u~~<br>~~n~~<br>~~etta z~~<br>~~H~~<br>~~0~~||~~0~~<br>~~3~~||~~d~~<br>~~eta~~<br>~~u~~<br>~~n~~<br>~~etta z~~<br>~~H~~<br>~~0~~|||~~0~~<br>~~3~~||~~d~~<br>~~eta~~<br>~~u~~<br>~~n~~<br>~~etta z~~<br>~~H~~<br>~~0~~||~~0~~<br>~~3~~||~~0~~<br>~~Hz attenuated~~| |~~Control inputs~~||~~Reset and Keylock~~|||~~Reset~~||||~~Reset and Keylock~~|~~Reset and~~||||~~Reset and~~||| |||||||||||~~application input~~|||~~application input~~|~~application input~~||| |~~Keylock~~||~~external input~~|||~~programmable~~||||~~external input~~|~~programmable~~||||~~programmable~~||| |~~Mounting depth~~||~~32 mm~~|~~32 mm~~||~~32 mm~~||~~32 mm~~||~~60 mm~~|~~60 mm~~||~~60 mm~~||~~60 mm~~||~~60 mm~~| |||||||||||||||||| |~~**Software**~~||||||||||||||||| |~~**Impulse counter**~~||~~x~~|||~~x~~||||~~x~~|~~x~~||||~~x~~||| |~~ni~~<br>~~m~~<br>~~/1 rete~~<br>~~m~~<br>~~o~~<br>~~h~~<br>~~c~~<br>~~a~~<br>~~T~~||~~x~~|||~~x~~|||||~~x~~||||~~x~~||| |~~Time counter h : 1/100 h~~|~~Time counter h : 1/100 h~~|~~x~~|||~~x~~||||~~x~~|~~x~~||||~~x~~||| |~~Time counter h : min : s~~|~~Time counter h : min : s~~|~~x~~|||~~x~~||||~~x~~|~~x~~||||~~x~~||| |~~C~~<br>~~L~~<br>~~P rof y~~<br>~~alp~~<br>~~sid la~~<br>~~cire~~<br>~~m~~<br>~~u~~<br>~~N~~|||||~~x~~|||||~~x~~||||~~x~~||| |~~ro~~<br>~~ta~~<br>~~cid~~<br>~~ni n~~<br>~~oitis~~<br>~~o~~<br>~~P~~||||||||||~~x~~||||~~x~~||| |~~bi directional~~||||||||||||||||| |~~**Counter with**~~||||||||||||||||| |~~**differential mode**~~||||||||||||||~~x~~||| |~~Maintenance counter~~||||||||||||||||| |~~(on request)~~||||||||||||||~~x~~||| Components _E N C O D E R S_ _**C O U N T E R S** C O N T R O L L E R S I N D I C A T O R S R E L A Y S P R I N T E R S C U T T E R S_ ## ~~**Technical data**~~ ## ~~**tico 731**~~ **TYPE 1** - :a LCD display RESET: reset input with contact a Lithium battery (negative, 30 Hz) COUNT: programmable count input KEYLOCK: locking of the reset key for voltage signal or contact, short case frequency 7.5 kHz or 30 Hz **TECHNICAL DATA** **DIMENSIONS CONNECTION DIAGRAM** **ORDER NUMBER** |~~Operating temperature~~|~~Operating temperature~~|||~~-10 ... 50°C~~| |---|---|---|---|---| |~~Strorage temperature~~<br>~~Electrical connection~~<br>~~Mounting~~<br>~~Front panel cutout~~||||~~-20 ... +60°C~~<br>~~screw terminals, cable length < 30 m~~<br>~~with clamping frame~~<br>~~45 + 0.6 x 22 + 0.3 mm~~| |~~Protection class (IEC 144)~~|||~~Protection class (IEC 144)~~|~~front side IP 54, terminals IP 20~~| |~~Dynamic strength~~||||~~10 m/s2 (10 ... 150 Hz) according to IEC 68-T2-6~~| |~~Shock stability~~||||~~100 m/s2 (18 ms) according to IEC 68-T2-27~~| |~~General rating~~||||~~according to EN 61010-1, EN 50178, protective system II~~| |~~Pulse shape~~||||~~any square wave (1:1 for max. frequency)~~| |~~Input resistance~~||||~~< 50 kOhm (static)~~| |~~Min. pulse length~~||||~~17 ms (30 Hz), 70 µs (7.5 kHz)~~| |~~Display~~||||~~8-digit LCD, 7 mm~~| |~~Supply voltage Ub~~||||~~internal lithium battery~~| |~~Nominal data retention~~||||~~lithium battery: 7 years~~| |||||| |~~Inputs:~~||||| |~~Amplitude thresholds~~||||~~voltage input up to 7.5 kHz:~~| |||||~~< 0.7 V and > 5 V, max 30 V DC~~| |~~Active edge~~||||~~negative or positive edge programmable~~| |~~Counting frequency~~||||~~programmable: 7.5 kHz or 30 Hz (attenuated for contacts)~~| |||||| |~~Control inputs:~~||||| |~~Reset~~||||~~- manual reset via keyboard(can be locked)~~| |||||~~- external reset with static behaviour, active edge negative~~| |||||~~attenuated 30 Hz~~| |~~Reset lock~~||||~~via Keylock input, bridged to 0 V~~| |~~Counting frequency~~||||~~max. 7.5 kHz~~| |||||| ||48|||7| |**tico 731**||||**Terminal assignment:**| |||||Clamping frame<br>21 \| |Dimensions in mm||||Connecting terminal| |Model tico 731||||| |||||***** Option: with plug-in<br>*****| |0 731||||1<br>0<br>1<br>S<br>screw terminals| |||||**Software function**| |||||01 impulse counter| |||||**02** tachometer (1/min)| |||||**03** time counter (hhhh:mm:ss)| |||||**04** time counter (hhhhhh.hh)| Components _E N C O D E R S_ _**C O U N T E R S** C O N T R O L L E R S I N D I C A T O R S R E L A Y S P R I N T E R S C U T T E R S_ ## **tico 731** ## ~~**Technical data**~~ **TYPE 2** - LCD display a RESET: reset input with contact DC supply voltage 12 – 24 V DC (negative, 30 Hz) COUNT: programmable count input short case for voltage signal or contact, frequency 7.5 kHz or 30 Hz **TECHNICAL DATA** **DIMENSIONS CONNECTION DIAGRAM** **ORDER NUMBER** ||~~Operating temperature~~|~~Operating temperature~~|~~Operating temperature~~|~~Operating temperature~~||~~-10 ... 50°C~~|| |---|---|---|---|---|---|---|---| ||~~Strorage temperature~~|||||~~-20 ... +60°C~~|| ||~~Electrical connection~~||~~Electrical connection~~|||~~screw terminals~~|| ||~~Mmounting~~|||||~~with clamping frame~~|| ||~~Front panel cutout~~|||||~~45 + 0.6 x 22 + 0.3 mm~~|| ||~~Protection class (IEC 144)~~||||~~Protection class (IEC 144)~~|~~front side IP 54, terminals IP 20~~|~~front side IP 54, terminals IP 20~~| ||~~Dynamic strength~~|||||~~10 m/s2 (10 ... 150 Hz) according to IEC 68-T2-6~~|| ||~~Shock stability~~|||||~~100 m/s2 (18 ms) according to IEC 68-T2-27~~|| ||~~General rating~~|||||~~according to EN 61010-1, EN 50178, protective system II~~|| ||~~Pulse shape~~|||||~~any square wave (1:1 for max. frequency)~~|| ||~~Input resistance~~|||||~~< 50 kOhm (static)~~|| ||~~Min. pulse length~~|||||~~17 ms (30 Hz), 70 µs (7.5 kHz)~~|| ||~~Display~~|||||~~8-digit LCD, 7 mm~~|| ||~~Supply voltage Ub ~~|||||~~12 ... 24 V DC*~~|| ||~~Current consumption DC~~||~~Current consumption DC~~|||~~12 ... 24 V DC < 5 mA~~|| ||~~Nominal data retention~~|||||~~nonvolatile memory > 10 years~~|| |*Not to be connected to a DC|Not to be connected to a DC-Network. For further information see manual.||||||Network. For further information see manual.| ||~~Inputs:~~||||||| ||~~Amplitude thresholds~~|||||~~voltage input up to 7.5 kHz:~~|| |||||||~~< 0.7 V and > 5 V, max. 30 V DC~~|| ||~~Active edge~~|||||~~negative or positive edge programmable~~|| ||~~Counting frequency~~|||||~~programmable: 7.5 kHz or 30 Hz (attenuated for contacts)~~|~~programmable: 7.5 kHz or 30 Hz (attenuated for contacts)~~| ||||||||| ||~~Control inputs:~~||||||| ||~~Reset~~|||||~~- manual reset via keyboard(can be locked)~~|| |||||||~~- external reset with static behaviour, active edge negative~~|| |||||||~~attenuated 30 Hz~~|| ||~~Reset lock~~|||||~~programmable via front key~~|| ||~~Counting frequency~~|||||~~max. 7.5 kHz, transmission rate for numerical display: 100 Hz~~|| ||||||||| ||48|||||40|| ||**tico 731**||||||**Terminal assignment:**| ||Dimensions in mm|||||Clamping frame<br>Connecting terminal<br>ei1|| ||Model tico 731||||||| ||0 731<br>2<br>0<br>1<br>**Software function**<br>S<br>***** Option: with plug-in<br>screw terminals<br>*****<br>CH||||||| |||||||01 impulse counter|| |||||||02 tachometer (1/min)|| |||||||03 time counter (hhhh:mm:ss)|| |||||||04 time counter (hhhhhh.hh)|| Components _E N C O D E R S_ _**C O U N T E R S** C O N T R O L L E R S I N D I C A T O R S R E L A Y S P R I N T E R S C U T T E R S_ ## ~~**Technical data tico 731**~~ ## **TYPE 3** **TECHNICAL DATA** **DIMENSIONS CONNECTION DIAGRAM** - LCD display - RESET: reset input for voltage pulses 12-250 V AC/DC (20 Hz) - Lithium battery pulses 12-250 V AC/DC (20 Hz) COUNT: count input for voltage | KEYLOCK: locking of the reset key pulses 12-250 V AC/DC (20 Hz) long case |~~Operating temperature~~|~~Operating temperature~~|~~-10 ... 50°C~~||| |---|---|---|---|---| |~~Storage temperature~~<br>~~Electrical connection~~<br>~~Mounting~~<br>~~Front panel cutout~~||~~-20 ... +60°C~~<br>~~screw terminals, cable length < 30 m~~<br>~~with clamping frame~~<br>~~45 + 0.6 x 22 + 0.3 mm~~||| |~~Protection class (IEC 144)~~<br>~~front side IP 54, terminals IP 20~~||||| |~~Dynamic strength~~||~~10 m/s2 (10 ... 150 Hz) according to IEC 68-T2-6~~||| |~~Shock stability~~||~~100 m/s2 (18 ms) according to IEC 68-T2-27~~||| |~~General rating~~||~~according to EN 61010-1, EN 50178, protective system II~~||| |~~Pulse shape~~||~~any square wave (1:1 for max. frequency)~~||| |~~Input resistance~~||~~< 50 kOhm (static)~~||| |~~Min. pulse length~~||~~25 ms (20 Hz)~~||| |~~Display~~||~~8-digit LCD, 7 mm~~||| |~~Supply voltage Ub~~||~~internal lithium battery~~||| |~~Current consumption DC~~||~~lithium battery: 7 years~~||| |||||| |~~Inputs:~~||||| |~~Amplitude thresholds~~||~~high voltage input 20 Hz:~~||| |||~~< 3 V and > 12 V, max. 250 V DC/AC~~||| |~~Active edge~~||~~voltage input positive edge~~||| |~~Counting frequency~~||~~20 Hz~~||| |||||| |~~Control inputs:~~||||| |~~Reset~~||~~- manual reset via keyboard(can be locked)~~||| |||~~- external reset with static behaviour,~~||| |||~~positive circuit~~||| |~~Reset lock~~||~~by means of bridge on the keylock input~~||| |||||| ||48|68||| |||**Terminal assignment:**|**Terminal assignment:**|| |||**tico 731**<br> pBasABH0!|yi <br>oe|3 <br>"=|de<br>9g| |||Clamping frame||| |||Connecting terminal||| |Dimensions in mm||||| **ORDER NUMBER** **==> picture [217 x 68] intentionally omitted <==** **----- Start of picture text -----**<br> Model tico 731<br>0 731 3 0 1<br>[LL<br>Software function<br>01 impulse counter<br>03 time counter (hhhh:mm:ss)<br>04 time counter (hhhhhh.hh)<br>**----- End of picture text -----**<br> Components _E N C O D E R S_ _**C O U N T E R S** C O N T R O L L E R S I N D I C A T O R S R E L A Y S P R I N T E R S C U T T E R S_ ## **tico 731** ## ~~**Technical data**~~ **TYPE 4** **TECHNICAL DATA** > LCD display | INPUT 2: control input for tempor12-24 V DC supply voltage ary locking of count input (gate) or COUNT: programmable count input second count input with position for voltage signal or contact, indicator frequency 7.5 kHz or 30 Hz a RESET: reset input OUT: transistor output for preset signal | long case ||~~Operating temperature~~|~~-10 ... 50°C~~| |---|---|---| ||~~Strorage temperature~~|~~-20 ... +60°C~~| ||~~Electrical connection~~|~~screw terminals, cable length < 30 m~~| ||~~Mounting~~|~~with clamping frame~~| ||~~Front panel cutout~~|~~45 + 0.6 x 22 + 0.3 mm~~| ||~~Protection class (IEC 144)~~|~~front side IP 54, terminals IP 20~~| ||~~Dynamic strength~~|~~10 m/s2 (10 ... 150 Hz) according to IEC 68-T2-6~~| ||~~Shock stability~~|~~100 m/s2 (18 ms) according to IEC 68-T2-27~~| ||~~General rating~~|~~according to EN 61010-1, EN 50178, protective system II~~| ||~~Pulse shape~~|~~any square wave (1:1 for max. frequency)~~| ||~~Input resistance~~|~~< 50 kOhm (static)~~| ||~~Min. pulse length~~|~~17 ms (30 Hz), 70 µs (7.5 kHz)~~| ||~~Display~~|~~8-digit LCD, 7 mm~~| ||~~Supply voltage Ub ~~|~~12 … 24 V DC*~~| ||~~Current consumption DC~~|~~12 … 24 V DC < 50 mA~~| ||~~Nominal data retention~~|~~nonvolatile memory > 10 years~~| |*Not to be connected to a DC|Not to be connected to a DC-Network. For further information see manual.|Network. For further information see manual.| ||~~Count input:~~|| ||~~Amplitude thresholds~~|~~voltage input up to 7.5 kHz:~~| |||~~< 0.7 V and > 5 V, max. 30 V DC~~| ||~~Active edge~~|~~negative or positive edge programmable~~| ||~~Counting frequency~~|~~programmable: 7.5 kHz or 30 Hz (attenuated for contacts)~~| |||~~with position indicator 2 kHz: active edge positive~~| ||~~Control inputs:~~|| ||~~Reset~~|~~– manual reset via keyboard(can be locked)~~| |||~~– external reset with static behaviour, 30 Hz attenuated~~| |||~~same edge as with count input~~| ||~~Input 2:~~|~~gate or second count channel; same edge as with count input~~| ||~~Reset lock~~|~~programmable via front key~~| ||~~Transistor output signal~~|~~PNP output~~| ||~~Voltage/switching current voltage supply minus 2 V; max. 10 mA~~|~~Voltage/switching current voltage supply minus 2 V; max. 10 mA~~| ||~~Counting frequency max. 7.5 kHz, transmission rate for numerical display: 1 kHz~~|~~Counting frequency max. 7.5 kHz, transmission rate for numerical display: 1 kHz~~| **INFORMATION**[This is a class A device. This device may cause radio interferences in] residentialenviroments. In this case, the user may be asked to take care of reasonable action. **DIMENSIONS CONNECTION DIAGRAM** **ORDER NUMBER** **==> picture [293 x 155] intentionally omitted <==** **----- Start of picture text -----**<br> Terminal assignment:<br>tico 731<br>GeeGHGEE 7<br>SP on uke ie<br>Clamping frame<br>Dimensions in mm<br>Connecting terminal<br>Model tico 731<br>Software function<br>0 731 4 0 1 01 impulse counter<br>[LIJ L— 02 tachometer (1/min)<br>03 time counter (hhhh:mm:ss)<br>04 time counter (hhhhhh.hh)<br>06 bidirectional position indicator<br>12-24 VDC 0 V Count Reset Input 2 Tr. out<br>**----- End of picture text -----**<br> Components _E N C O D E R S_ _**C O U N T E R S** C O N T R O L L E R S I N D I C A T O R S R E L A Y S P R I N T E R S C U T T E R S_ ## ~~**Technical data tico 731**~~ ## **TYPE 5** **TECHNICAL DATA** **DIMENSIONS CONNECTION DIAGRAM** **ORDER NUMBER** INPUT 2: control input for temporary locking of count input (gate) or second count input with position indicator RESET: reset input OUT: transistor output for preset signal long case LED display 12-24 V DC supply voltage COUNT: programmable count input for voltage signal or contact, frequency 7.5 kHz or 30 Hz |||~~Operating temperature~~|~~Operating temperature~~|~~Operating temperature~~|~~-10 ... 50°C~~||||||| |---|---|---|---|---|---|---|---|---|---|---|---| |||~~Strorage temperature~~|||~~-20 ... +60°C~~||||||| |||~~Electrical connection~~<br>~~Mounting~~<br>~~Front panel cutout~~|||~~screw terminals~~<br>~~with clamping frame~~<br>~~45 + 0.6 x 22 + 0.3 mm~~||||||| |||~~Protection class (IEC 144) front side IP 54, terminals IP 20~~|||~~Protection class (IEC 144) front side IP 54, terminals IP 20~~|~~Protection class (IEC 144) front side IP 54, terminals IP 20~~|||||| |||~~Dynamic strength~~|||~~10 m/s2 (10 ... 150 Hz) according to IEC 68-T2-6~~||||||| |||~~Shock stability~~|||~~100 m/s2 (18 ms) according to IEC 68-T2-27~~||||||| |||~~General rating~~|||~~according to EN 61010-1, EN 50178, protective system II~~||||||| |||~~Pulse shape~~|||~~any square wave (1:1 for max. frequency)~~||||||| |||~~Input resistance~~|||~~< 50 kOhm (static)~~||||||| |||~~Min. pulse length~~|||~~17 ms (30 Hz), 70 µs (7,5 kHz)~~||||||| |||~~Display~~|||~~6-digit LCD, 7 mm~~||||||| |||~~Supply voltage Ub ~~|||~~12 … 24 V DC*~~||||||| |||~~Current consumption DC~~|~~Current consumption DC~~||~~12 … 24 V DC < 50 mA~~||||||| |||~~Nominal data retention~~|||~~nonvolatile memory > 10 years~~||||||| ||||||||||||| |||~~Count input:~~|||||||||| |||~~Amplitude thresholds~~|||~~voltage input up to 7.5 kHz:~~||||||| ||||||~~< 0.7 V and > 5 V, max. 30 V DC~~||||||| |||~~Active edge~~|||~~negative or positive edge programmable~~||||||| |||~~Counting frequency~~|||~~programmable: 7.5 kHz or 30 Hz(attenuated for contacts)~~||||||| ||||||~~with position indicator 2 kHz~~||||||| |* Not to be connected to a DC-Network. For further information see manual.||* Not to be connected to a DC-Network. For further information see manual.|||* Not to be connected to a DC-Network. For further information see manual.|* Not to be connected to a DC-Network. For further information see manual.|||||| |||~~Control inputs:~~|||||||||| |||~~Reset~~|||~~– manual reset via keyboard~~|~~board(can be locked)~~|||||| ||||||~~– external reset with static behaviour, same ed~~||~~same edge as count in~~||~~e as count input~~||| |||~~Input 2:~~|||~~gate or second count channel~~||||||| |||~~Reset lock~~|||~~programmable via front key~~||||||| |||~~Transistor output signal~~|||~~PNP output~~||||||| |||~~Voltage/switching current ~~|||~~supply minus 2 V; max. 10 mA~~||||||| |||~~Counting frequency~~|||~~max. 7.5 kHz, transmission rate for numerical display: 1 kHz~~|||~~max. 7.5 kHz, transmission rate for numerical display: 1 kHz~~||~~max. 7.5 kHz, transmission rate for numerical display: 1 kHz~~|~~max. 7.5 kHz, transmission rate for numerical display: 1 kHz~~| ||||||||||||| ||||||;|**Terminal assignment:**|||||| |||**tico 731**||||12-24 VDC|0 V|Count|Reset|Input 2|Tr. out| ||||||Clamping frame||||||| |||Dimensions in mm||||Connecting terminal|||||| |||Model tico 731|||||||||| |||0 731<br>5<br>0<br>1<br>0 731<br>5<br>0<br>7<br>**Software function**<br>01 impulse counter<br>02 tachometer (1/min)<br>03 time counter (hhhh:mm:ss)<br>04 time counter (hhhhhh.hh)<br>06 bidirectional position indicator<br>07 counter with differential mode (1 kHz)<br>~~aan~~|||||||07 counter with differential mode (1 kHz)||| Components _E N C O D E R S_ _**C O U N T E R S** C O N T R O L L E R S I N D I C A T O R S R E L A Y S P R I N T E R S C U T T E R S_ ## **tico 731** ## **SPECIAL FUNCTIONS** ## ~~**Special functions**~~ To best match your application, you can order special functions such as prescaler value, decimal point and preset value, which are permanently set by us before delivery. With the variable prescaler value you can adapt to already existing transfer ratios of your application. Small resolutions can be shown with the decimal point, e. g. for the position indicator or the tachometer. A special feature is the possibility of displaying an information text in the display, e. g. for the surveillance of maintenance cycles. In this case the desired information is shown in the display after reaching the fixed preset value. You can display any text that can be created with the 7-segment alphabet, e. g. STOP, HELP, FILTER etc. **ORDER NUMBERS SPECIAL VERSIONS** **ORDER NUMBERS SPECIAL VERSIONS** |~~**Special functions**~~|~~**Impulse**~~|~~**Tacho- **~~|~~**Time**~~|~~**Numerical**~~|~~**Position**~~|~~**Differential**~~| |---|---|---|---|---|---|---| |~~**r**~~<br>~~**o**~~<br>~~**f**~~|~~**r**~~<br>~~**e**~~<br>~~**t**~~<br>~~**n**~~<br>~~**u**~~<br>~~**o**~~<br>~~**c**~~|~~**r**~~<br>~~**e**~~<br>~~**t**~~<br>~~**e**~~<br>~~**m**~~|~~**r**~~<br>~~**e**~~<br>~~**t**~~<br>~~**n**~~<br>~~**u**~~<br>~~**o**~~<br>~~**c**~~|~~**y**~~<br>~~**alp**~~<br>~~**sid**~~|~~**r**~~<br>~~**o**~~<br>~~**t**~~<br>~~**a**~~<br>~~**cid**~~<br>~~**ni**~~|~~**r**~~<br>~~**e**~~<br>~~**t**~~<br>~~**n**~~<br>~~**u**~~<br>~~**o**~~<br>~~**c**~~| |||||||| |~~e~~<br>~~ula~~<br>~~v rela~~<br>~~cs~~<br>~~erP~~|~~x~~|~~x~~|||~~x~~|~~x~~| |~~0.000015 to 65535,99998~~||||||| |~~t~~<br>~~nio~~<br>~~p la~~<br>~~m~~<br>~~ic~~<br>~~e~~<br>~~D~~|~~x~~|~~x~~|||~~x~~|~~x~~| |~~0 to 3positions~~||||||| |~~behind the comma~~||||||| |~~Preset value~~|~~x~~||~~x~~|||| |~~0 to 99 999 999~~||||||| |~~Information text~~|~~x~~||~~x~~|||| |~~(on reaching the~~||||||| |~~preset value)~~||||||| |~~LCD = 8 characters~~||||||| |~~LED = 6 characters~~||||||| ## **Choose version and basic function:** Model tico 731 *** *** Option: with plug-in **0 731 7 S** screw terminals only for standard model 1, 2 **Standard version: Function:** 1) not available for 1 Standard model 1 **1 Impulse counter** standard type 3 2) not available for 2 Standard model 2 2 Tachometer (1/min)[1)] standard types 1, 2, 3 3 Standard model 3 3 Time counter (hhhh:mm:ss) 3) only available for 4 Standard model 4 4 Time counter (hhhhhh.hh) standard type 5 5 Standard model 5 6 Position indicator (2-channel)[2)] **7 Counter with differential mode[3)]** ## **Please state the desired special version on your order:** ||**P: (Value);**|Prescaler value:|0.000015 to 65535,999984)| |---|---|---|---| ||||| ||**D: (Value);**|Decimal point:|0 to 3 positions after the dot4)| ||**V: (Value);**|Preset value:|0 to 99 999 9995)| ||||| ||**T: (Text);**|The information<br>preset value can|text displayed on reaching the<br>be built up as required from the| |||7-segment alphabet|| ||||4) not available for time counters| ||||5) not available for tachometers| ||||and position indicator| Components _E N C O D E R S_ _**C O U N T E R S** C O N T R O L L E R S I N D I C A T O R S R E L A Y S P R I N T E R S C U T T E R S_
Updated at April 28, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →