Image not available
Illustrative purposes only
6HS16B
Thermal Magnetic Circuit Breaker, Loadstar B Curve, 16 A, 1 Pole, 230 VAC, DIN Rail
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: CRABTREE
- Product type: Thermal Magnetic Circuit Breakers
- No. of Poles: 1 Pole
- Product Range: Loadstar B Curve
- Current Rating: 16A
- Voltage Rating VAC: 230VAC
- Circuit Breaker Mounting: DIN Rail
| Delivery and price | |
|---|---|
| Units per pack | 3 |
| Price | 6.96 € |
| Current stock | 10+ |
| Lead time | 7 days |
## **DATA SHEET FOR 1 & 3 POLE 10kA LOADSTAR MCBs B, C AND D CURVES** |**Technical specifications**|||| |---|---|---|---| |**Standards Approved** acc. to|||BS EN 60898 IEC/EN 60947-2| |**Operational voltage**|min.|V AC/DC|24| |Acc. to EN 60898 and EN 60947-2|max.|V DC/pole|*60| ||max.|V AC|440| |Acc. to UL1077 and CSA C22.2|||| |No.235|max.|V AC|480| |||V DC/pole|60| |**Rated switching capacity**|||| |• Icn acc. to IEC/EN 60898-1||kA AC|10| |• Icn acc. to IEC/EN 60898-2||kA DC|| |• Icu acc. to IEC/EN 60947-2||kA AC|15| |•Acc. to UL 1077 and CSA C22.2||kA AC|5| |**Insulation coordination**|||| |• Rated insulation voltage||V AC|250/440| |• Degree of pollution for|||| |overvoltage category|||3/lll| |**Touch protection**|||Yes| |to EN 50274-1|||| |**Handle endposition**,sealable|||Yes| |**Degree of protection**|||IP20, with connected conductors| |acc. to EN 60529|||| |**CFC and silicone-free**|||Yes| |**Mounting**|||| |• Snap-on fixing system|||Yes| |• Standard mounting rail and screw|||| |connection|||| |**Terminals**|||| |• Tunnel terminals at both ends|||| |• Combined terminals at both ends|||Yes| |• Terminal connection solid,|||| |stranded or finely stranded, with|||| |ferrule|||0.75 ... 25| |• Terminal tighteningtorque||Nm|2.5 ... 3| |**Conductor cross-sections**|||| |• Solid and stranded, top and|||| |bottom terminal||mm²|0.75 ... 35| |• Finely stranded, with end sleeve,|||| |topand bottom terminal||mm²|0.75 ... 25| |**Mains connection**|||Any| |**Mounting position**|||Any| |**Service life**|||| |on average,with rated load|||20000 operations (6 to 32A); 10,000 operations (40 to 63A)| ||||-25 ... +45, occasionally +55, max. 95 % humidity, storage| |**Ambient temperature**||°C|temperature: -40 ... +75| |**Resistance to climate**|||6 cycles| |Acc. to IEC 60068-2-30|||| |**Resistance to vibrations**|||| |Acc. to IEC 60068-2-6||m/s²|60 at 10 Hz ... 150 Hz| * The operational voltage 60 V DC/pole takes into account a battery charging voltage with peak value of 72 V. ## **DATA SHEET FOR 1 & 3 POLE 10kA LOADSTAR MCBs B, C AND D CURVES** For universal use in socket outlet and lighting circuits Particularly advantageous in lamp and motor circuits with higher starting currents For electrical circuits with strong pulse generating equipment, such as transformers |**Earth fault loop impedances (Zs ohms)**<br>**to give compliance with BS7671**<br>**regulations 411.3.2.2 and 411.3.2.3 at**<br>**230V**|**Earth fault loop impedances (Zs ohms)**<br>**to give compliance with BS7671**<br>**regulations 411.3.2.2 and 411.3.2.3 at**<br>**230V**|**Earth fault loop impedances (Zs ohms)**<br>**to give compliance with BS7671**<br>**regulations 411.3.2.2 and 411.3.2.3 at**<br>**230V**|**Earth fault loop impedances (Zs ohms)**<br>**to give compliance with BS7671**<br>**regulations 411.3.2.2 and 411.3.2.3 at**<br>**230V**| |---|---|---|---| |-|Maximum earth-fault loop<br>impedance(Ohms)||| |Device<br>Rating<br>~~rs~~|MCB type<br>B<br>~~es~~|MCB type<br>C<br>~~ee~~|MCB type<br>D| |6<br>~~rs~~<br>~~ee~~|7.666<br>~~es~~<br>~~es~~|3.832<br>~~ee~~<br>~~es~~|1.917| |10<br>~~rs~~<br>~~ee~~<br>~~re~~|4.599<br>~~es~~<br>~~es~~<br>~~ee~~|2.299<br>~~ee~~<br>~~es~~<br>~~ee~~|1.150<br>~~ee~~<br>~~ee~~| |16<br>~~ee~~<br>~~re~~<br>~~rs~~|2.874<br>~~es~~<br>~~ee~~<br>~~ee~~|1.437<br>~~es~~<br>~~ee~~<br>~~ee~~|0.719<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~| |20<br>~~re~~<br>~~rs~~<br>~~ee~~|2.299<br>~~ee~~<br>~~ee~~|1.149<br>~~ee~~<br>~~ee~~|0.575<br>~~ee~~<br>~~ee~~<br>~~ee~~<br>~~ee~~| |25<br>~~rs~~<br>~~ee~~<br>~~re~~|1.839<br>~~ee~~|0.919<br>~~ee~~|0.460<br>~~ee~~<br>~~ee~~| |32<br>~~ee~~<br>~~re~~|1.437|0.718|0.359| |40<br>~~re~~<br>~~rs~~|1.149<br>~~ee~~|0.574<br>~~ee~~|0.288<br>~~ee~~| |50<br>~~rs~~<br>~~a~~<br>~~rs~~|0.919<br>~~ee~~<br>~~a~~|0.459<br>~~ee~~|0.230<br>~~ee~~| |63<br>~~a ~~<br>~~rs~~|0.729<br> ~~a~~|0.364|0.183| **DATA SHEET FOR 1 & 3 POLE 10kA LOADSTAR MCBs B, C AND D CURVES** ## **ORDERING INFORMATION** |**List No.**||| |---|---|---| |**Type B**|**Type C**|**Type D**| |6HS06B|6HS06C|6HS06D| |6HS10B|6HS10C|6HS10D| |6HS16B|6HS16C|6HS16D| |6HS20B|6HS20C|6HS20D| |6HS32B|6HS32C|6HS32D| |6HS40B|6HS40C|6HS40D| |6HS50B|6HS50C|6HS50D| |**List No.**||| |---|---|---| |**Type B**|**Type C**|**Type D**| |6HT06B|6HT06C|6HT06D| |6HT10B|6HT10C|6HT10D| |6HT16B|6HT16C|6HT16D| |6HT20B|6HT20C|6HT20D| |6HT32B|6HT32C|6HT32D| |6HT40B|6HT40C|6HT40D| |6HT50B|6HT50C|6HT50D| ## **DIMENSIONAL DRAWINGS**
Updated at February 9, 2023
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →