Image not available
Illustrative purposes only
6GK5598-1AA00-3AA0
Power Supply, 1 Phase, 40 A, 264 VAC, 300 W, IP20, 12.5 A, 24 VDC, 44 mm x 446 mm x 140 mm
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Controller Accessories
- SVHC: To Be Advised
- Product Range: -
- Current Rating: 40A
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 1197.12 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6GK5598-1AA00-3AA0** **Data sheet** **product type designation** **Power Supply PS598-1** SCALANCE PS598-1 Power-Supply 300 W input: 85-264 V AC IEC plug; Output: DC 24 V connecting terminals or for direct connection to SCALANCE X-500. **==> picture [397 x 475] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |product brand name|SCALANCE| |re|type of current supply|300 W, input: 85-264 V, output:DC 24| |Technical Product Detail Page|https://i.siemens.com/1P6GK5598-1AA00-3AA0| |electrical data / input| |voltage curve / at input|AC single phase| |supply voltage / 1 / rated value|230 V| |● supply voltage / 1 / rated value|85 ... 264 V| |● type of voltage / 1 / of the supply voltage|AC| |design of input / wide range input|Yes| |overvoltage category|Category II (20 A rated branch circuit)| |buffering time / for rated value of the output current / in the|16 ms| |event of power failure / minimum| |line frequency|47 ... 63 Hz| |input current / at rated input voltage 230 V / rated value|1.8 A| |current limitation / of inrush current / at 25 °C / maximum|40 A| |ee| |fuse protection type / at input|replaceable| |electrical data / output| |voltage curve / at output|Controlled, isolated DC voltage| |output voltage| |● 1 / at DC / rated value|24 V| |display version / for normal operation|Green LED for 24 V ok and fault LED| |behavior of the output voltage / when switching on|Overshoot of Ua < 5 %| |startup delay time / maximum|1.5 s| |voltage increase time / of the output voltage / maximum|15 ms| |output current| |● rated value|12.5 A| |● rated range|0 ... 12.5 A| |supplied active power / typical|300 W| |product feature / parallel switching of channels|Yes| |number of parallel-switched equipment resources / for|2| |increasing the power| |re|efficiency in percent|87 %| |power loss [W]|39 W| |electrical data / closed-loop control| |relative overall tolerance / of the voltage|2 %| |residual ripple / maximum|0.36 V| |voltage peak / maximum|240 V| |relative control precision / of the output voltage| **----- End of picture text -----**<br> 6GK55981AA003AA0 Page 1/3 Subject to change without notice © Copyright Siemens 5/27/2026 |● on slow fluctuation of input voltage|0.2 %| |---|---| |● on slow fluctuation of ohm loading|0.4 %| |● load stepof resistive load 50/100/50 % / typical|3.25 %| |● with rapid fluctuation of the input voltage by +/- 15% /<br>typical|0.8 %| |settingtime|| |● load step50 to 100% / typical|2 ms| |● load step 100 to 50% / typical|2 ms| |**electrical data / protection and monitoring**|| |design of the overvoltageprotection / at output|< 37 V| |response value current limitation / typical|1.15 A| |propertyof the output / short-circuitproof|Yes| |design of short-circuit protection|Electronic shutdown, automatic restart| |**electrical data / safety**|| |galvanic isolation / between input and output|Yes| |galvanic isolation|Safetyextra-low output voltage Uout acc. to EN 60950-1 and EN 50178| |operatingresourceprotection class|Class I| |leakage current|| |● maximum|3 mA| |● typical|0.858 mA| |**interfaces**|| |type of electrical connection|| |● at input|IECplug| |● at output|for plugginginto basic device or screw terminal in accordance with specification| |**design, dimensions and weights**|| |width|446 mm| |height|44 mm| |depth|140 mm| |net weight|1.7 kg| |product feature / of the enclosure / housingcan be lined up|No| |fasteningmethod|Plugged into the basic unit or rack mounted| |● 19-inch installation|Yes| |● wall mounting|No| |● DIN-rail mounting|No| |● S7-300 rail mounting|No| |**ambient conditions**|| |ambient temperature|| |● duringoperation|60 °C| |● duringstorage|-25 ... +70 °C| |● duringtransport|-25 ... +70 °C| |● note|Operation with integral fan, non-replaceable| |environmental category/ accordingto IEC 60721|Climate class 3K3, without condensation| |protection class IP|IP20| |**standards, specifications, approvals**|| |standard|| |● for safety/ from CSA and UL|UL 60950-1, CSA C22.2 No. 60950-1| |● for emitted interference|EN 55022(Class B)| |● for interference immunity|EN 61000-6-2| |certificate of suitability|EN 55022, EN 61000-6-4| |● CE marking|Yes| |● C-Tick|Yes| |● E1 approval|No| |● E1 approval|No| |● railwayapplication in accordance with EN 50155|No| |● railwayapplication in accordance with EN 50124-1|No| |● IEC 61850-3|No| |MTBF|17.47 a| |**standards, specifications, approvals / Environmental Product Declaration**|| |Environmental Product Declaration|Yes| 6GK55981AA003AA0 Page 2/3 Subject to change without notice © Copyright Siemens 5/27/2026 global warming potential [CO2 eq] ● total 595.14999 kg ● during manufacturing 62.11 kg ● during operation 532.63999 kg ● after end of life 0.4 kg ~~a~~ **further information / internet links** internet link ● to website: Selection guide for cables and connectors https://support.industry.siemens.com/cs/ww/en/view/109766358 ● to web page: selection aid TIA Selection Tool https://www.siemens.com/tstcloud ● to website: Industrial communication https://www.siemens.com/simatic-net ● to web page: SiePortal https://sieportal.siemens.com/ ● to website: Image database https://www.automation.siemens.com/bilddb ● to website: CAx-Download-Manager https://www.siemens.com/cax ● to website: Industry Online Support https://support.industry.siemens.com ~~|~~ **security information** security information Siemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement - and continuously maintain - a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7) **Approvals / Certificates** **General Product Approval** Declaration of Conformity ~~c~~ A China RoHS **General Product ApEMV proval** & **last modified:** **Environment** 5/9/2026 6GK55981AA003AA0 Page 3/3 Subject to change without notice © Copyright Siemens 5/27/2026
Updated at April 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →