6ES7455-1VS00-0AE0
Controller Module, 16 Channel, 32 Digital Output, 400 mA, 24 VDC, 210 mm x 50 mm x 290 mm
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type:
- SVHC: To Be Advised
- Product Range: SIMATIC S7-400 Series
- Current Rating: 400mA
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 2796.18 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6ES7455-1VS00-0AE0** **Data sheet** SIMATIC S7-400, control module FM 455 S, 16 channels, step and pulse, 8/16 AI + 16 DI+ 32 DO ||SIMATIC S7-400, control module FM 455 S, 16 channels, step and pulse, 8/16 AI<br>+ 16 DI+ 32 DO| |---|---| |**Supply voltage**<br>~~EEEEE—E—E—E—EeEeE~~|| |Load voltage L+<br>~~EEEEE—E—E—E—EeEeE~~|| |● Rated value(DC)|24 V| |●permissible range, lower limit(DC)|20.4 V| |● permissible range, upper limit(DC)|28.8 V| |**Input current**<br>~~|~~|| |from load voltage L+(without load), max.<br>~~|~~|400 mA; typ. 330 mA<br>~~|~~| |**Power loss**<br>~~|~~|| |Power loss, typ.<br>~~|~~|10.7 W<br>~~|~~| |Power loss, max.|16.2 W| |**Digital inputs**<br>~~|~~|| |Number of digital inputs<br>~~|~~|16<br>~~|~~| |Input characteristic curve in accordance with IEC 61131, type 2<br>~~ee~~|Yes<br>~~ee~~| |Input voltage<br>~~ee~~|| |● Rated value(DC)|24 V| |● for signal "0"|-3 to +5V| |● for signal "1"<br>~~|~~|13 to 30V<br>~~|~~| |Input current<br>~~|~~|| |● for signal "1", typ.<br>~~a~~|7 mA<br>~~a~~| |Cable length<br>~~a~~|| |● shielded, max.|1 000 m| |● unshielded, max.|600 m| |**Digital outputs**<br>~~|~~|| |Number of digital outputs<br>~~|~~|32<br>~~|~~| |Short-circuitprotection<br>~~Oe~~|Yes; Electronic<br>~~Oe~~| |Limitation of inductive shutdown voltage to<br>~~Oe~~|L+(-1.5 V)<br>~~Oe~~| |Controllinga digital input<br>~~Oe~~|Yes<br>~~Oe~~| |Switchingcapacityof the outputs|| |● on lampload, max.<br>~~I~~|5 W<br>~~I~~<br>~~__~~| |Load resistance range<br>~~I~~<br>~~__~~|| |● lower limit|240 Ω<br>~~__~~| |● upper limit<br>~~|~~|4 kΩ<br>~~|~~| |Output voltage<br>~~|~~|| |● for signal "1", min.<br>~~a~~|L+(-2.5 V)<br>~~a~~| |Output current<br>~~a~~|| |● for signal "1" rated value|0.1 A| |● for signal "1"permissible range for 0 to 60 °C, min.|5 mA| |● for signal "1"permissible range for 0 to 60 °C, max.|150 mA| |● for signal "0" residual current, max.|0.5 mA| 6ES74551VS000AE0 Page 1/4 Subject to change without notice © Copyright Siemens 6/1/2026 ||Parallel switchingof two outputs|Parallel switchingof two outputs|| |---|---|---|---| ||● for logic links|Yes|| ||Switchingfrequency||| ||● with resistive load, max.|100 Hz|| ||● with inductive load, max.|0.5 Hz|| ||● on lampload, max.|100 Hz|| ||Cable length||| ||● shielded, max.|1 000 m|| ||● unshielded, max.|600 m|| ||**Analog inputs**||| ||Number of analog inputs|16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire<br>connection|| ||permissible input voltage for voltage input (destruction limit),<br>max.|20 V|| ||permissible input current for current input (destruction limit),<br>max.|40 mA|| ||Input ranges||| ||● Voltage|Yes|| ||● Current|Yes|| ||● Thermocouple|Yes|| ||● Resistance thermometer|Yes|| ||Input ranges(rated values), voltages||| ||● 0 to +10 V|Yes|| ||— Input resistance(0 to 10 V)|100 kΩ|| ||● -1.75 V to +11.75 V|Yes|| ||— Input resistance(-1.75 V to +11.75 V)|100 kΩ|| ||● -80 mV to +80 mV|Yes|| ||— Input resistance(-80 mV to +80 mV)|10 MΩ|| ||Input ranges(rated values), currents||| ||● 0 to 20 mA|Yes|| ||— Input resistance(0 to 20 mA)|50 Ω|| ||● 0 to 23.5 mA|Yes|| ||— Input resistance(0 to 23.5 mA)|50 Ω|| ||● -3.5 mA to +23.5 mA|Yes|| ||— Input resistance(-3.5 mA to +23.5 mA)|50 Ω|| ||● 4 mA to 20 mA|Yes|| ||— Input resistance(4 mA to 20 mA)|50 Ω|| ||Input ranges(rated values), thermocouples||| ||● type B|Yes|| ||— Input resistance(Type B)|10 MΩ|| ||● Type J|Yes|| ||— Input resistance(type J)|10 MΩ|| ||● Type K|Yes|| ||— Input resistance(Type K)|10 MΩ|| ||● Type R|Yes|| ||— Input resistance(Type R)|10 MΩ|| ||● Type S|Yes|| ||— Input resistance(Type S)|10 MΩ|| ||Input ranges(rated values), resistance thermometer||| ||● Pt 100|Yes|| ||— Input resistance(Pt 100)|10 MΩ|| ||Thermocouple(TC)||| ||Temperature compensation||| ||— internal temperature compensation|Yes; Parameterizable|| ||— external temperature compensation with Pt100|Yes; Parameterizable|| ||Characteristic linearization||| ||● Parameterizable|Yes|| ||— for thermocouples|Type B, J, K, R, S|| ||— for resistance thermometer|Pt100(standard)|| ||Cable length||| 6ES74551VS000AE0 Page 2/4 Subject to change without notice © Copyright Siemens 6/1/2026 ||● shielded, max.|200 m; 50 m at 80 mV and thermocouples|200 m; 50 m at 80 mV and thermocouples|200 m; 50 m at 80 mV and thermocouples|| |---|---|---|---|---|---| ||**Analog value generation for the inputs**||||| ||Integration and conversion time/resolutionper channel||||| ||● Resolution with overrange(bit includingsign), max.|14 bit; 12 bit or 14 bit,parameterizable|||| ||● Conversion time (per channel)|16.67 ms; for 12 bit: 16 2/3 ms for 60 Hz, 20 ms for 50 Hz; for 14 bit: 100 ms for<br>50 Hz and 60 Hz|||| ||**Encoder**||||| ||Connection of signal encoders||||| ||● for voltage measurement|Yes|||| ||● for current measurement as 4-wire transducer|Yes|||| ||Connectable encoders||||| ||● 2-wire sensor|Yes|||| ||— permissible quiescent current(2-wire sensor), max.|1.5 mA|||| ||**Errors/accuracies**||||| ||Operational error limit in overall temperature range||||| ||● Voltage, relative to input range,(+/-)|±0.6 to ±1%|||| ||● Current, relative to input range,(+/-)|±0.6 to ±1%|||| ||● Resistance thermometer, relative to input range,(+/-)|±0.6 to ±1%|||| ||Basic error limit(operational limit at 25 °C)||||| ||● Voltage, relative to input range,(+/-)|±0.4 to ±0.6 %|||| ||● Current, relative to input range,(+/-)|±0.4 to ±0.6 %|||| ||● Resistance thermometer, relative to input range,(+/-)|±0.4 to ±0.6 %|||| ||**Interrupts/diagnostics/status information**||||| ||Substitute values connectable|Yes; Parameterizable|||| ||**Integrated Functions**||||| ||Control technology||||| ||● Number of closed-loop controllers|16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire<br>connection|||| ||**Potential separation**||||| ||Potential separation controller||||| ||● between the channels|No|||| ||● between the channels and backplane bus|Yes; Optocoupler|||| ||**Isolation**||||| ||Isolation tested with|500 V DC|||| ||**Connection method**||||| ||required front connector|2x 48-pin|||| ||**Dimensions**||||| ||Width|50 mm|||| ||Height|290 mm|||| ||Depth|210 mm|||| ||**Weights**||||| ||Weight, approx.|1 400g|||| ||**Classifications**||||| ||||**Version**|**Classification**|| |||eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>ETIM<br>ETIM<br>ETIM<br>ETIM<br>IDEA<br>UNSPSC|14<br>12<br>9.1<br>9<br>8<br>7.1<br>6<br>10<br>9<br>8<br>7<br>4<br>15|27-24-22-05<br>27-24-22-05<br>27-24-22-05<br>27-24-22-05<br>27-24-22-05<br>27-24-22-05<br>27-24-22-05<br>EC001422<br>EC001422<br>EC001422<br>EC001422<br>3567<br>32-15-17-05|| 6ES74551VS000AE0 Page 3/4 Subject to change without notice © Copyright Siemens 6/1/2026 **==> picture [510 x 436] intentionally omitted <==** **----- Start of picture text -----**<br> ee Approvals / Certificates<br>General Product Approval<br>ce Miscellaneous ® & Metrological Approval k<br>For use in hazard-<br>General Product Approval EMV ous locations<br>&& China RoHS Miscellaneous<br>For use in hazardous locations<br>FM Type Examination Cer-<br>tificate<br>@=~<br>©<br>Maritime application<br>-<br>NK / Nippon Kaiji Ky<br>okai<br>® a ——<br>@<br>Maritime application<br>-<br>CCS (China Classifica<br>tion Society)<br>Pe<br>**----- End of picture text -----**<br> **last modified:** **==> picture [30 x 6] intentionally omitted <==** **----- Start of picture text -----**<br> 6/7/2025<br>**----- End of picture text -----**<br> 6ES74551VS000AE0 Page 4/4 Subject to change without notice © Copyright Siemens 6/1/2026
Updated at March 31, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →