Image not available
Illustrative purposes only
6ES7455-0VS00-0AE0
Controller Module, 16 Channel, 16 Analog Output, 440 mA, 24 VDC, 210 mm x 50 mm x 290 mm
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Controller Accessories
- SVHC: To Be Advised
- Product Range: SIMATIC S7-400 Series
- Current Rating: 440mA
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 3124.17 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6ES7455-0VS00-0AE0** **Data sheet** SIMATIC S7-400, control module FM 455 C, 16 channels, continuous, 8/16 AI + 16 DI+ 16 AO |SIMATIC S7-400, control module FM 455 C, 16 channels, continuous, 8/16 AI + 16<br>DI+ 16 AO<br>**Supply voltage**<br>Load voltage L+<br>● Rated value(DC)<br>24 V<br>●permissible range, lower limit(DC)<br>20.4 V<br>● permissible range, upper limit(DC)<br>28.8 V<br>**Input current**<br>from load voltage L+(without load), max.<br>440 mA; typ. 370 mA<br>**Power loss**<br>Power loss, typ.<br>12 W<br>Power loss, max.<br>17.3 W<br>**Digital inputs**<br>Number of digital inputs<br>16<br>Input characteristic curve in accordance with IEC 61131, type 2<br>Yes<br>Input voltage<br>● Rated value(DC)<br>24 V<br>● for signal "0"<br>-3 to +5V<br>● for signal "1"<br>13 to 30V<br>Input current<br>● for signal "1", typ.<br>7 mA<br>Cable length<br>● shielded, max.<br>1 000 m<br>● unshielded, max.<br>600 m<br>**Analog inputs**<br>Number of analog inputs<br>16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire<br>connection<br>permissible input voltage for voltage input (destruction limit),<br>max.<br>20 V<br>permissible input current for current input (destruction limit),<br>max.<br>40 mA<br>Input ranges<br>● Voltage<br>Yes<br>● Current<br>Yes<br>● Thermocouple<br>Yes<br>● Resistance thermometer<br>Yes<br>Input ranges(rated values), voltages<br>● 0 to +10 V<br>Yes<br>— Input resistance(0 to 10 V)<br>100 kΩ<br>● -1.75 V to +11.75 V<br>Yes<br>— Input resistance (-1.75 V to +11.75 V)<br>100 kΩ<br>Figure similar|SIMATIC S7-400, control module FM 455 C, 16 channels, continuous, 8/16 AI + 16<br>DI+ 16 AO|| |---|---|---| ||Yes|| ||100 kΩ|| ||Yes|| ||100 kΩ|| 6ES74550VS000AE0 Page 1/4 Subject to change without notice © Copyright Siemens 5/17/2026 |● -80 mV to +80 mV|Yes| |---|---| |— Input resistance(-80 mV to +80 mV)|10 MΩ| |Input ranges(rated values), currents|| |● 0 to 20 mA|Yes| |— Input resistance(0 to 20 mA)|50 Ω| |● 0 to 23.5 mA|Yes| |— Input resistance(0 to 23.5 mA)|50 Ω| |● -3.5 mA to +23.5 mA|Yes| |— Input resistance(-3.5 mA to +23.5 mA)|50 Ω| |● 4 mA to 20 mA|Yes| |— Input resistance(4 mA to 20 mA)|50 Ω| |Input ranges(rated values), thermocouples|| |● Type B|Yes| |— Input resistance(Type B)|10 MΩ| |● Type J|Yes| |— Input resistance(type J)|10 MΩ| |● Type K|Yes| |— Input resistance(Type K)|10 MΩ| |● Type R|Yes| |— Input resistance(Type R)|10 MΩ| |● Type S|Yes| |— Input resistance(Type S)|10 MΩ| |Input ranges(rated values), resistance thermometer|| |● Pt 100|Yes| |— Input resistance(Pt 100)|10 MΩ| |Thermocouple(TC)|| |Temperature compensation|| |— internal temperature compensation|Yes; Parameterizable| |— external temperature compensation with Pt100|Yes; Parameterizable| |Characteristic linearization|| |●parameterizable|Yes| |— for thermocouples|Type B, J, K, R, S| |— for resistance thermometer|Pt100(standard)| |Cable length|| |● shielded, max.|200 m; 50 m at 80 mV and thermocouples| |**Analog outputs**|| |Number of analogoutputs|16| |Voltage output, short-circuitprotection|Yes| |Voltage output, short-circuit current, max.|25 mA| |Current output, no-load voltage, max.|18 V| |Output ranges, voltage|| |● 0 to 10 V|Yes| |● -10 V to +10 V|Yes| |Output ranges, current|| |● 0 to 20 mA|Yes| |● -20 mA to +20 mA|Yes| |● 4 mA to 20 mA|Yes| |Connection of actuators|| |● for voltage output two-wire connection|Yes| |● for current output two-wire connection|Yes| |Load impedance(in rated range of output)|| |● with voltage outputs, min.|1 kΩ| |● with voltage outputs, capacitive load, max.|1µF| |● with current outputs, max.|500 Ω| |● with current outputs, inductive load, max.|1 mH| |Cable length|| |● shielded, max.|200 m; 50 m at 80 mV and thermocouples| |**Analog value generation for the inputs**|| |Integration and conversion time/resolution per channel|| 6ES74550VS000AE0 Page 2/4 Subject to change without notice © Copyright Siemens 5/17/2026 |● Resolution with overrange(bit includingsign), max.|14 bit; 12 bit or 14 bit,parameterizable|14 bit; 12 bit or 14 bit,parameterizable|14 bit; 12 bit or 14 bit,parameterizable| |---|---|---|---| |● Conversion time (per channel)|16.67 ms; for 12 bit: 16 2/3 ms for 60 Hz, 20 ms for 50 Hz; for 14 bit: 100 ms for<br>50 Hz and 60 Hz||| |**Analog value generation for the outputs**|||| |Settlingtime|||| |● for resistive load|0.1 ms||| |● for capacitive load|3.3 ms||| |● for inductive load|0.5 ms||| |**Encoder**|||| |Connection of signal encoders|||| |● for voltage measurement|Yes||| |● for current measurement as 4-wire transducer|Yes||| |Connectable encoders|||| |● 2-wire sensor|Yes||| |— permissible quiescent current(2-wire sensor), max.|1.5 mA||| |**Errors/accuracies**|||| |Operational error limit in overall temperature range|||| |● Voltage, relative to input range,(+/-)|±0.6 to ±1%||| |● Current, relative to input range,(+/-)|±0.6 to ±1%||| |● Resistance thermometer, relative to input range,(+/-)|±0.6 to ±1%||| |● Voltage, relative to output range,(+/-)|0.5 %||| |● Current, relative to output range,(+/-)|0.6 %||| |Basic error limit(operational limit at 25 °C)|||| |● Voltage, relative to input range,(+/-)|±0.4 to ±0.6 %||| |● Current, relative to input range,(+/-)|±0.4 to ±0.6 %||| |● Resistance thermometer, relative to input range,(+/-)|±0.4 to ±0.6 %||| |● Voltage, relative to output range,(+/-)|0.4 %||| |● Current, relative to output range,(+/-)|0.5 %||| |**Interrupts/diagnostics/status information**|||| |Substitute values connectable|Yes; Parameterizable||| |**Integrated Functions**|||| |Control technology|||| |● Number of closed-loop controllers|16; With thermocouples or 2-wire connection; 8 with Pt 100 or 4-wire<br>connection||| |**Potential separation**|||| |Potential separation controller|||| |● between the channels|No||| |● between the channels and backplane bus|Yes; Optocoupler||| |**Isolation**|||| |Isolation tested with|500 V DC||| |**Connection method**|||| |required front connector|2x 48-pin||| |**Dimensions**|||| |Width|50 mm||| |Height|290 mm||| |Depth|210 mm||| |**Weights**|||| |Weight, approx.|1 400g||| |**Classifications**|||| |||**Version**|**Classification**| ||eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass|14<br>12<br>9.1<br>9<br>8<br>7.1<br>6|27-24-22-05<br>27-24-22-05<br>27-24-22-05<br>27-24-22-05<br>27-24-22-05<br>27-24-22-05<br>27-24-22-05| 6ES74550VS000AE0 Page 3/4 Subject to change without notice © Copyright Siemens 5/17/2026 **==> picture [510 x 570] intentionally omitted <==** **----- Start of picture text -----**<br> ETIM 10 EC001422<br>ETIM 9 EC001422<br>ETIM 8 EC001422<br>ETIM 7 EC001422<br>IDEA 4 3567<br>UNSPSC 15 32-15-17-05<br>ee Approvals / Certificates<br>General Product Approval<br>1 EG-Konf, Miscellaneous Ca nt rr Metrological Approval |<br>For use in hazard-<br>General Product Approval EMV ous locations<br>& — China RoHS Miscellaneous = +& &<br>RCM RCM RCM IECEx<br>For use in hazardous locations<br>FM Type Examination Cer-<br>tificate<br>€) 7 — =— - &<br>Maritime application<br>-<br>NK / Nippon Kaiji Ky<br>okai<br>®©F&<br>Maritime application<br>-<br>CCS (China Classifica<br>— tion Society)<br>®<br>last modified: 6/7/2025 G<br>**----- End of picture text -----**<br> 6ES74550VS000AE0 Page 4/4 Subject to change without notice © Copyright Siemens 5/17/2026
Updated at April 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →