Image not available
Illustrative purposes only
6ES7307-1EA01-0AA0
Isolated DIN Rail Mount DC/DC Converter, 2:1, 18 W, 1 Output, 24 VDC, 5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Isolated DIN Rail Mount DC / DC Converters
- Depth: 120mm
- Width: 60mm
- Height: 125mm
- Input Ratio: 2:1
- Product Range: SIMATIC S7-300 Series
- No. of Outputs: 1 Output
- Output Power Max: 18W
- Isolation Voltage: -
- Output Regulation: Regulated
- Input Voltage DC Max: -
- Input Voltage DC Min: -
- Input Voltage DC Nom: -
- Output Current - Output 1: 5A
- Output Current - Output 2: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Power Supply Applications: -
- DC / DC Converter Output Type: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 197.49 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6ES7307-1EA01-0AA0** **Data sheet** SIMATIC PS307/1AC/24VDC/5A SIMATIC S7-300 Regulated power supply PS307 input: 120/230 V AC, output: 24 V/5 A DC |= =<br>(<br>4<br>rl|SIMATIC PS307/1AC/24VDC/5A<br>SIMATIC S7-300 Regulated power supply PS307 input: 120/230 V AC, output: 24<br>V/5 A DC| |---|---| |**General information**|| |Technical Product Detail Page|https://i.siemens.com/1P6ES7307-1EA01-0AA0| |**input**|| |type of thepower supplynetwork|1-phase AC| |supplyvoltage at AC|Automatic range selection| |supplyvoltage|120 V/230 V| |input voltage 1 at AC|85 ... 132 V| |input voltage 2 at AC|170 ... 264 V| |wide range input|No| |overvoltage overload capability|2.3 × Vin rated, 1.3 ms| |buffering time for rated value of the output current in the event of<br>power failure minimum|20 ms| |operatingcondition of the mains buffering|at Vin = 93/187 V| |line frequency|50/60 Hz| |line frequency|47 ... 63 Hz| |input current|| |● at rated input voltage 120 V|2.3 A| |● at rated input voltage 230 V|1.2 A| |current limitation of inrush current at 25 °C maximum|20 A| |duration of inrush current limitingat 25 °C|| |● maximum|3 ms| |I2t value maximum|1.2 A²·s| |fuseprotection type|T 3,15 A/250 V(not accessible)| |fuse protection type in the feeder|Recommended miniature circuit breaker: from 6 A characteristic C| |**output**|| |voltage curve at output|Controlled, isolated DC voltage| |output voltage at DC rated value|24 V| |output voltage|| |● at output 1 at DC rated value|24 V| |output voltage adjustable|No; -| |relative overall tolerance of the voltage|3 %| |relative controlprecision of the output voltage|| |● on slow fluctuation of input voltage|0.1 %| |● on slow fluctuation of ohm loading|0.5 %| |residual ripple|| |● maximum|50 mV| |● typical|10 mV| |voltagepeak|| |● maximum|150 mV| 6ES73071EA010AA0 Page 1/5 Subject to change without notice © Copyright Siemens 5/17/2026 |● typical|20 mV| |---|---| |displayversion for normal operation|Green LED for 24 V OK| |behavior of the output voltage when switchingon|No overshoot of Vout(soft start)| |response delaymaximum|2 s| |voltage increase time of the output voltage|| |● typical|10 ms| |output current|| |● rated value|5 A| |● rated range|0 ... 5 A| |supplied activepower typical|120 W| |short-term overload current|| |● on short-circuitingduringthe start-uptypical|20 A| |● at short-circuit duringoperation typical|20 A| |duration of overloadingcapabilityfor excess current|| |● on short-circuitingduringthe start-up|100 ms| |● at short-circuit duringoperation|100 ms| |bridgingof equipment|Yes| |**efficiency**|| |efficiencyinpercent|87 %| |power loss[W]|| |● at rated output voltage for rated value of the output<br>current typical|18 W| |**closed-loop control**|| |relative control precision of the output voltage with rapid<br>fluctuation of the input voltage by+/- 15% typical|0.1 %| |relative control precision of the output voltage load step of<br>resistive load 50/100/50 % typical|1 %| |settingtime|| |● load step50 to 100% typical|0.3 ms| |● load step 100 to 50% typical|0.3 ms| |**protection and monitoring**|| |design of the overvoltageprotection|Additional control loop, shutdown at < 28.8 V, automatic restart| |propertyof the output short-circuitproof|Yes| |design of short-circuitprotection|Electronic shutdown, automatic restart| |response value current limitation|5.5 ... 6.5 A| |enduringshort circuit current RMS value|| |● maximum|7 A| |**safety**|| |galvanic isolation between input and output|Yes| |galvanic isolation|Output voltage: SELV, ES1(IEC 62368-1), DVC As(IEC 61204-7)| |operatingresourceprotection class|Class I| |leakage current|| |● maximum|3.5 mA| |● typical|0.5 mA| |protection class IP|IP20| |**EMC**|| |standard|| |● for emitted interference|EN 55022 Class B| |● for mains harmonics limitation|EN 61000-3-2| |● for interference immunity|EN 61000-6-2| |**standards, specifications, approvals**|| |certificate of suitability|| |● CE marking|Yes| |● UL approval|Yes; cULus-Listed(UL 508, CSA C22.2 No. 142), File E143289| |● UKCA marking|Yes| |● EAC approval|Yes| |● NEC Class 2|No| |type of certification|| |● BIS|Yes; R-41183539| 6ES73071EA010AA0 Page 2/5 Subject to change without notice © Copyright Siemens 5/17/2026 |● CB-certificate|Yes| |---|---| |MTBF at 40 °C|2 480 589 h| |**standards, specifications, approvals hazardous environments**|| |certificate of suitability|| |● IECEx|Yes; IECEx Ex nA nC IIC T3 Gc| |● ATEX|Yes; ATEX(EX)II 3G Ex nA nC IIC T3 Gc| |● ULhazloc approval|Yes| |● UKEX|Yes| |● CCC for hazardous zone accordingto GB standard|Yes| |● FM registration|Yes; Class I, Div. 2, Group ABCD, T4| |**standards, specifications, approvals marine classification**|| |shipbuildingapproval|Yes| |Marine classification association|| |● American Bureau of ShippingEurope Ltd.(ABS)|No| |● French marine classification society (BV)|No| |● Det Norske Veritas(DNV)|Yes| |● Lloyds Register of Shipping (LRS)|Yes| |**standards, specifications, approvals Environmental Product Declaration**|| |Environmental Product Declaration|Yes| |global warming potential[CO2 eq]|| |● total|504.1 kg| |● duringmanufacturing|11.3 kg| |● duringoperation|492.3 kg| |● after end of life|0.41 kg| |**ambient conditions**|| |ambient temperature|| |● duringoperation|0 ... 60 °C; with natural convection| |● duringtransport|-40 ... +85 °C| |● duringstorage|-40 ... +85 °C| |environmental categoryaccordingto IEC 60721|Climate class 3K3, 5 ... 95% no condensation| |**connection method**|| |type of electrical connection|screw terminal| |● at input|L, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm² single-core/finelystranded| |● at output|L+, M: 3 screw terminals each for 0.5 ... 2.5 mm²| |● for auxiliarycontacts|-| |**mechanical data**|| |width × height × depth of the enclosure|60 × 125 × 120 mm| |installation width × mountingheight|60 mm × 205 mm| |required spacing|| |● top|40 mm| |● bottom|40 mm| |● left|0 mm| |● right|0 mm| |fasteningmethod|Can be mounted onto S7 rail| |● DIN-rail mounting|No| |● S7 rail mounting|Yes| |● wall mounting|No| |housingcan be lined up|Yes| |net weight|0.6 kg| |**accessories**|| |mechanical accessories|Mountingadapter for standard mountingrail(6EP1971-1BA00)| |**further information internet links**|| |internet link|| |● to website: IndustryMall|https://mall.industry.siemens.com| |● to webpage: selection aid TIA Selection Tool|https://www.siemens.com/tstcloud| |● to website: CAx-Download-Manager|https://siemens.com/cax| |● to website: IndustryOnline Support|https://support.industry.siemens.com| |**additional information**|| 6ES73071EA010AA0 Page 3/5 Subject to change without notice © Copyright Siemens 5/17/2026 **==> picture [510 x 214] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |other information|Specifications at rated input voltage and ambient temperature +25 °C (unless| |otherwise specified)| |rr|security information| |security information|Siemens provides products and solutions with industrial cybersecurity functions| |that support the secure operation of plants, systems, machines and networks.| |In order to protect plants, systems, machines and networks against cyber| |threats, it is necessary to implement - and continuously maintain - a holistic,| |state-of-the-art industrial cybersecurity concept. Siemens’ products and| |solutions constitute one element of such a concept. Customers are responsible| |for preventing unauthorized access to their plants, systems, machines and| |networks. Such systems, machines and components should only be connected| |to an enterprise network or the internet if and to the extent such a connection is| |necessary and only when appropriate security measures (e.g. firewalls and/or| |network segmentation) are in place. For additional information on industrial| |cybersecurity measures that may be implemented, please visit| |www.siemens.com/cybersecurity-industry. Siemens’ products and solutions| |undergo continuous development to make them more secure. Siemens strongly| |recommends that product updates are applied as soon as they are available| |and that the latest product versions are used. Use of product versions that are| |no longer supported, and failure to apply the latest updates may increase| |customer’s exposure to cyber threats. To stay informed about product updates,| |subscribe to the Siemens Industrial Cybersecurity RSS Feed under| |https://www.siemens.com/cert. (V4.7)| **----- End of picture text -----**<br> **Classifications** **==> picture [511 x 344] intentionally omitted <==** **----- Start of picture text -----**<br> ||||||| |---|---|---|---|---|---| |Version|Classification| |eClass|14|27-04-07-01| |eClass|12|27-04-07-01| |eClass|9.1|27-04-07-01| |eClass|9|27-04-07-01| |eClass|8|27-04-90-02| |eClass|7.1|27-04-90-02| |eClass|6|27-04-90-02| |ETIM|10|EC002540| |ETIM|9|EC002540| |ETIM|8|EC002540| |ETIM|7|EC002540| |IDEA|4|4130| |UNSPSC|15|39-12-10-04| |Approvals Certificates| |en|Environmental Product Declaration| |● global warming potential [CO2 eq] / during manufacturing|11.3 kg| |● global warming potential [CO2 eq] / during operation|492.3 kg| |● global warming potential [CO2 eq] / after end of life|0.41 kg| |● global warming potential [CO2 eq] / total|504.1 kg| |Environment|General Product Approval| |Manufacturer Declara-|Declaration of Con-|China RoHS| |tion|formity| |EPD|cB|ce|7|_|i| **----- End of picture text -----**<br> **General Product Approval** **For use in hazardEMV ous locations** ~~—~~ BIS CRS **For use in hazardous locations** 6ES73071EA010AA0 Page 4/5 Subject to change without notice © Copyright Siemens 5/17/2026 **==> picture [494 x 269] intentionally omitted <==** **----- Start of picture text -----**<br> Miscellaneous — ® ~~ FM CCC-Ex @<br>IECEx ATEX UL<br>For use in hazard-<br>ous locations Maritime application<br>-<br>NK / Nippon Kaiji Ky<br>okai<br>IECEx ABS Oni LAS<br>Maritime application<br>-<br>CCS (China Classifica<br>tion Society)<br>; ¢—<br>PRS FINA<br>last modified: 5/5/2026 G<br>**----- End of picture text -----**<br> 6ES73071EA010AA0 Page 5/5 Subject to change without notice © Copyright Siemens 5/17/2026
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →