Image not available
Illustrative purposes only
6ES7155-5AA01-0AB0
Interface Module, 12 I/O, 35 mm x 129 mm x 147 mm
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Controller Accessories
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 379.32 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6ES7155-5AA01-0AB0** **Data sheet** SIMATIC ET 200MP. PROFINET IO-DEVICE INTERFACEMODULE IM 155-5 PN ST FOR ET 200MP ELEKTRONIKMODULES; UP TO 12 IO-MODULES WITHOUT ADDITIONAL PS; UP TO 30 IO- MODULES WITH ADDITIONONAL PS SHARED DEVICE; MRP; IRT >=0.25MS; ISOCHRONICITY FW-UPDATE; I&M0...3; FSU WITH 500MS |Figure similar|SIMATIC ET 200MP. PROFINET IO-DEVICE INTERFACEMODULE IM 155-5 PN<br>ST FOR ET 200MP ELEKTRONIKMODULES; UP TO 12 IO-MODULES WITHOUT<br>ADDITIONAL PS; UP TO 30 IO- MODULES WITH ADDITIONONAL PS SHARED<br>DEVICE; MRP; IRT >=0.25MS; ISOCHRONICITY FW-UPDATE; I&M0...3; FSU<br>WITH 500MS| |---|---| |**General information**|| |Product type designation|IM 155-5 PN ST| |HW functional status|from FS01| |Firmware version|V4.1.0| |● FW updatepossible|Yes| |Vendor identification(VendorID)|0x002A| |Device identifier(DeviceID)|0X0312| |Product function|| |● I&M data|Yes; I&M0 to I&M3| |● Module swappingduringoperation(hot swapping)|No| |● Isochronous mode|Yes| |● IRT|Yes| |● Tool changer|No| |● Local coupling, IO data|No| |Engineeringwith|| |● STEP 7 TIA Portal configurable/integrated from version|V15| |● STEP 7 configurable/integrated from version|use GSD file| |● PROFINET from GSD version/GSD revision|GSDML V2.3| |**Configuration control**|| |via dataset|Yes| |**Supply voltage**|| |Rated value(DC)|24 V| |permissible range, lower limit(DC)|19.2 V| |permissible range, upper limit(DC)|28.8 V| |Reversepolarity protection|Yes| |Short-circuitprotection|Yes| |Mains buffering|| |● Mains/voltage failure stored energytime|10 ms| |**Input current**|| |Current consumption(rated value)|0.2 A; at 24 V DC and without load| |Current consumption, max.|1.2 A| |Inrush current, max.|9 A| |I²t|0.09 A²·s| |**Power**|| |Infeedpower to the backplane bus|14 W| |Power consumption from the backplane bus|2.3 W; in case of operation with separate system power supplyto the left of IM| |**Power loss**|| |Power loss, typ.|4.5 W| 6ES71555AA010AB0 Page 1/4 Subject to change without notice © Copyright Siemens 5/21/2026 ||**Address area**|**Address area**|| |---|---|---|---| ||Address spaceper module||| ||● Address spaceper module, max.|256 byte; For input and output data respectively|| ||Address spaceper station||| ||● Address space per station, max.|512 byte; For input and output data respectively|| ||**Hardware configuration**||| ||Integratedpower supply|Yes; 14 W|| ||Systempower supplycan beplugged in to left of IM|Yes|| ||Number ofpermissiblepower segments|3; incl. interface module|| ||Rack||| ||● Modulesper rack, max.|30; I/O modules|| ||Submodules||| ||● Number of submodules per station, max.|256; 9 per I/O module|| ||**Interfaces**||| ||Transmissionprocedure|100BASE-TX|| ||Number of PROFINET interfaces|1; 2 ports(switch)|| ||**1. Interface**||| ||Interface types||| ||● RJ 45(Ethernet)|Yes|| ||● Number ofports|2|| ||● integrated switch|Yes|| ||● BusAdapter(PROFINET)|No|| ||Protocols||| ||● PROFINET IO Device|Yes|| ||● Open IE communication|Yes|| ||● Media redundancy|Yes; PROFINET MRP client|| ||PROFINET IO Device||| ||Services||| ||— IRT|Yes; 250µs to 4 ms in 125µs frame|| ||— Dynamic Frame Packing (DFP)|No|| ||— PROFIenergy|No|| ||— Prioritized startup|Yes|| ||— Shared device|Yes|| ||— Number of IO Controllers with shared device, max.|2|| ||**Interface types**||| ||RJ 45(Ethernet)||| ||● Transmissionprocedure|PROFINET with 100 Mbit/s full duplex(100BASE-TX)|| ||● 100 Mbps|Yes|| ||● Autonegotiation|Yes|| ||● Autocrossing|Yes|| ||**Protocols**||| ||Supportsprotocol for PROFINET IO|Yes|| ||PROFIsafe|Yes|| ||PROFIBUS|No|| ||EtherNet/IP|No|| ||Modbus TCP|No|| ||Redundancymode||| ||● PROFINET system redundancy (S2)|No|| ||— on S7-1500R/H|No|| ||— on S7-400H|No|| ||● PROFINET system redundancy (R1)|No|| ||● H-Sync forwarding|No|| ||Media redundancy||| ||— MRP|Yes|| ||— MRPD|No|| ||Open IE communication||| ||● TCP/IP|Yes|| ||● SNMP|Yes|| ||● LLDP|Yes|| 6ES71555AA010AB0 Page 2/4 Subject to change without notice © Copyright Siemens 5/21/2026 |**Isochronous mode**|||| |---|---|---|---| |Equidistance|Yes||| |shortest clockpulse|250µs||| |max. cycle|4 ms||| |Bus cycle time(TDP), min.|250µs||| |Jitter, max.|1 µs||| |**Interrupts/diagnostics/status information**|||| |Status indicator|Yes||| |Alarms|Yes||| |Diagnostics function|Yes||| |Diagnostics indication LED|||| |● RUN LED|Yes;green LED||| |● ERROR LED|Yes; red LED||| |● MAINT LED|Yes; Yellow LED||| |● Connection displayLINK TX/RX|Yes; 2xgreen-yellow LEDs||| |**Potential separation**|||| |between backplane bus and electronics|No||| |between PROFINET and all other circuits|Yes; 1500 V AC(type test)||| |between supplyand all other circuits|No||| |**Permissible potential difference**|||| |between different circuits|Safetyextra low voltage SELV||| |**Isolation**|||| |Isolation tested with|707 V DC(type test)||| |**Standards, approvals, certificates**|||| |Siemens Eco Profile(SEP)|Siemens EcoTech||| |Network loadingclass|3||| |Ecological footprint|||| |● environmentalproduct declaration|Yes||| |Global warming potential|||| |—global warming potential,(total) [CO2 eq]|64.1 kg||| |— global warming potential, (during production) [CO2<br>eq]|11.1 kg||| |— global warming potential, (during operation) [CO2<br>eq]|53.6 kg||| |— global warming potential, (after end of life cycle)<br>[CO2 eq]|-0.669 kg||| |**Security**|||| |PROFINET SecurityClass|0||| |**Ambient conditions**|||| |Ambient temperature duringoperation|||| |● horizontal installation, min.|-25 °C; From FS03||| |● horizontal installation, max.|60 °C||| |● vertical installation, min.|-25 °C; From FS03||| |● vertical installation, max.|40 °C||| |Altitude duringoperation relatingto sea level|||| |● Installation altitude above sea level, max.|5 000 m; Restrictions for installation altitudes > 2 000 m, see manual||| |Absolute humidity|||| |● dew point, min.|-60 °C; suitable for dryroom applications||| |**Connection method**|||| |ET-Connection|||| |● via BU/BA Send|No||| |**Dimensions**|||| |Width|35 mm||| |Height|147 mm||| |Depth|129 mm||| |**Classifications**|||| |||**Version**|**Classification**| ||eClass|14|27-24-26-08| 6ES71555AA010AB0 Page 3/4 Subject to change without notice © Copyright Siemens 5/21/2026 ||||eClass|||12|27-24-26-08| |---|---|---|---|---|---|---|---| ||||eClass|||9.1|27-24-26-08| ||||eClass|||9|27-24-26-08| ||||eClass|||8|27-24-26-08| ||||eClass|||7.1|27-24-26-08| ||||eClass|||6|27-24-26-08| ||||ETIM|||10|EC001604| ||||ETIM|||9|EC001604| ||||ETIM|||8|EC001604| ||||ETIM|||7|EC001604| ||||IDEA|||4|3564| ||||UNSPSC|||15|32-15-17-05| |**Approvals / Certificates**<br>~~ee~~|||||||| |**General Product Approval**|||||||| ||®|©|||EAL||| |**General Product Approval**|||**Test Certificates**||**other**||| |Confirmation<br>~~——~~|cé|UK <br>GA|Special Test Certific-<br>ate<br> ~~—S~~||Confirmation<br>~~Of~~||as| |**Environment**|||||||| |Environmental Con-|Environmental Con-||||||| |firmations|firmations||||||| |**last modified:**||5/20/2026|||||| 6ES71555AA010AB0 Page 4/4 Subject to change without notice © Copyright Siemens 5/21/2026
Updated at April 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →