Image not available
Illustrative purposes only
6ES7155-5AA00-0AC0
Interface Module, 12 I/O, 35 mm x 129 mm x 147 mm
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Controller Accessories
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 430.95 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6ES7155-5AA00-0AC0** **Data sheet** *** spare part *** SIMATIC ET 200MP. PROFINET IO device interface module IM 155-5 PN HF, for ET 200MP electronic modules; up to 12 IO modules without PS; up to 30 IO modules with additional PS; integrated 2-port switch; RJ45 shared device; MRP; IRT >=0.25 ms; isochronous mode firmware update; I&M0...3; prioritized startup, S2 redundancy; shared device with 4 controllers suitable for operation with the active backplane bus (FW V4.4 or higher) |*** spare part *** SIMATIC ET 200MP. PROFINET IO device interface module IM<br>155-5 PN HF, for ET 200MP electronic modules; up to 12 IO modules without PS;<br>up to 30 IO modules with additional PS; integrated 2-port switch; RJ45 shared<br>device; MRP; IRT >=0.25 ms; isochronous mode firmware update; I&M0...3;<br>prioritized startup, S2 redundancy; shared device with 4 controllers suitable for<br>operation with the active backplane bus (FW V4.4 or higher)<br>**General information**<br>Product type designation<br>IM 155-5 PN HF<br>HW functional status<br>From FS03<br>Firmware version<br>V4.4<br>● FW updatepossible<br>Yes<br>Vendor identification(VendorID)<br>002AH<br>Device identifier(DeviceID)<br>0X0312<br>Product function<br>● I&M data<br>Yes; I&M0 to I&M3<br>● Module swappingduringoperation(hot swapping)<br>Yes; In combination with active backplane bus<br>● Isochronous mode<br>Yes<br>● IRT<br>Yes<br>● Tool changer<br>No<br>● Local coupling, IO data<br>No<br>Engineeringwith<br>● STEP 7 TIA Portal configurable/integrated from version<br>V16<br>● STEP 7 configurable/integrated from version<br>use GSD file<br>● PROFINET from GSD version/GSD revision<br>GSDML V2.3<br>**Configuration control**<br>via dataset<br>Yes<br>**Supply voltage**<br>Rated value(DC)<br>24 V<br>permissible range, lower limit(DC)<br>19.2 V<br>permissible range, upper limit(DC)<br>28.8 V<br>Reversepolarity protection<br>Yes<br>Short-circuitprotection<br>Yes<br>Mains buffering<br>● Mains/voltage failure stored energytime<br>5 ms<br>**Input current**<br>Current consumption(rated value)<br>0.2 A; at 24 V DC and without load<br>Current consumption, max.<br>1.2 A<br>Inrush current, max.<br>9 A<br>I²t<br>0.09 A²·s<br>**Power**<br>Infeedpower to the backplane bus<br>14 W<br>Power consumption from the backplane bus<br>2.3 W; in case of operation with separate system power supplyto the left of IM<br>**Power loss**<br>Power loss, typ.<br>4.5 W<br>**Address area**<br>~~a~~<br>~~a~~<br>~~a~~<br>~~ee~~<br>~~EE~~<br>~~eO@“~~<br>~~ee~~<br>~~a~~<br>~~eea~~<br>~~a~~<br>~~ee~~|*** spare part *** SIMATIC ET 200MP. PROFINET IO device interface module IM<br>155-5 PN HF, for ET 200MP electronic modules; up to 12 IO modules without PS;<br>up to 30 IO modules with additional PS; integrated 2-port switch; RJ45 shared<br>device; MRP; IRT >=0.25 ms; isochronous mode firmware update; I&M0...3;<br>prioritized startup, S2 redundancy; shared device with 4 controllers suitable for<br>operation with the active backplane bus (FW V4.4 or higher)|~~ee~~| |---|---|---| |Address spaceper module|Address spaceper module| |---|---| |● Address spaceper module, max.|256 byte; For input and output data respectively| |Address spaceper station|| |● Address space per station, max.|512 byte; For input and output data respectively| |**Hardware configuration**|| |Integratedpower supply|Yes; 14 W| |Systempower supplycan beplugged in to left of IM|Yes; onlywith design with U-connectors| |Number ofpermissiblepower segments|3; incl. interface module| |Rack|| |● Modulesper rack, max.|30; I/O modules| |Submodules|| |● Number of submodules per station, max.|256; 9 per I/O module| |**Interfaces**|| |Transmissionprocedure|100BASE-TX| |Number of PROFINET interfaces|1; 2 ports(switch)| |**1. Interface**|| |Interface types|| |● RJ 45(Ethernet)|Yes| |● Number ofports|2| |● integrated switch|Yes| |● BusAdapter(PROFINET)|No| |Protocols|| |● PROFINET IO Device|Yes| |● Open IE communication|Yes| |● Media redundancy|Yes; PROFINET MRP client / HRP client| |PROFINET IO Device|| |Services|| |— IRT|Yes; 250µs to 4 ms in 125µs frame| |— Dynamic Frame Packing (DFP)|No| |— PROFIenergy|No| |— Prioritized startup|Yes| |— Shared device|Yes| |— Number of IO Controllers with shared device, max.|4| |**Interface types**|| |RJ 45(Ethernet)|| |● Transmissionprocedure|PROFINET with 100 Mbit/s full duplex(100BASE-TX)| |● 100 Mbps|Yes| |● Autonegotiation|Yes| |● Autocrossing|Yes| |**Protocols**|| |Supportsprotocol for PROFINET IO|Yes| |PROFIsafe|Yes| |PROFIBUS|No| |EtherNet/IP|No| |Modbus TCP|No| |Redundancymode|| |● PROFINET system redundancy (S2)|Yes; NAP S2| |— on S7-1500R/H|Yes| |— on S7-400H|Yes; use GSD file| |● PROFINET system redundancy (R1)|No| |● H-Sync forwarding|Yes| |Media redundancy|| |— MRP|Yes| |— MRPD|Yes| |Open IE communication|| |● TCP/IP|Yes| |● SNMP|Yes| |● LLDP|Yes| 6ES71555AA000AC0 Page 2/4 Subject to change without notice © Copyright Siemens 5/21/2026 |**Isochronous mode**|||| |---|---|---|---| |Equidistance|Yes||| |shortest clockpulse|250µs||| |max. cycle|4 ms||| |Bus cycle time(TDP), min.|250µs||| |Jitter, max.|1 µs||| |**Interrupts/diagnostics/status information**|||| |Status indicator|Yes||| |Alarms|Yes||| |Diagnostics function|Yes||| |Diagnostics indication LED|||| |● RUN LED|Yes;green LED||| |● ERROR LED|Yes; red LED||| |● MAINT LED|Yes; Yellow LED||| |● Connection displayLINK TX/RX|Yes; 2xgreen-yellow LEDs||| |**Potential separation**|||| |between backplane bus and electronics|No||| |between PROFINET and all other circuits|Yes; 1500 V AC(type test)||| |between supplyand all other circuits|No||| |**Permissible potential difference**|||| |between different circuits|Safetyextra low voltage SELV||| |**Isolation**|||| |Isolation tested with|707 V DC(type test)||| |**Standards, approvals, certificates**|||| |Network loadingclass|3||| |**Security**|||| |PROFINET SecurityClass|0||| |**Ambient conditions**|||| |Ambient temperature duringoperation|||| |● horizontal installation, min.|-25 °C; from FS04||| |● horizontal installation, max.|60 °C||| |● vertical installation, min.|-25 °C; from FS04||| |● vertical installation, max.|40 °C||| |Altitude duringoperation relatingto sea level|||| |● Installation altitude above sea level, max.|5 000 m; Restrictions for installation altitudes > 2 000 m, see manual||| |Absolute humidity|||| |● dew point, min.|-60 °C; suitable for dryroom applications||| |**Connection method**|||| |ET-Connection|||| |● via BU/BA Send|No||| |**Dimensions**|||| |Width|35 mm||| |Height|147 mm||| |Depth|129 mm||| |**Weights**|||| |Weight, approx.|350g||| |**Classifications**|||| |||**Version**|**Classification**| ||eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>ETIM|14<br>12<br>9.1<br>9<br>8<br>7.1<br>6<br>10|27-24-26-08<br>27-24-26-08<br>27-24-26-08<br>27-24-26-08<br>27-24-26-08<br>27-24-26-08<br>27-24-26-08<br>EC001604| 6ES71555AA000AC0 Page 3/4 Subject to change without notice © Copyright Siemens 5/21/2026 ETIM 9 EC001604 ETIM 8 EC001604 ETIM 7 EC001604 IDEA 4 3564 UNSPSC 15 32-15-17-05 ~~ee~~ **Approvals / Certificates General Product Approval EMV** EAL ~~—~~ Confirmation c egK @ **other Environment** Confirmation Environmental ConEnvironmental Con- ~~— Oo~~ firmations firmations " QC PASS EPD **last modified:** 5/20/2026 6ES71555AA000AC0 Page 4/4 Subject to change without notice © Copyright Siemens 5/21/2026
Updated at April 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →