Image not available
Illustrative purposes only
6ES7138-7EC00-0AA0
Isolated DIN Rail Mount DC/DC Converter, 2:1, 21.3 W, 1 Output
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Isolated DIN Rail Mount DC / DC Converters
- SVHC: To Be Advised
- Depth: 136.5mm
- Width: 60mm
- Height: 190mm
- Input Ratio: 2:1
- Product Range: SIMATIC DP Series
- No. of Outputs: 1 Output
- Output Power Max: 21.3W
- Isolation Voltage: -
- Output Regulation: -
- Input Voltage DC Max: -
- Input Voltage DC Min: -
- Input Voltage DC Nom: -
- Output Current - Output 1: -
- Output Current - Output 2: -
- Output Voltage - Output 1: -
- Output Voltage - Output 2: -
- Power Supply Applications: -
- DC / DC Converter Output Type: -
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 2011.44 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6ES7138-7EC00-0AA0** **Data sheet** SIMATIC, power supply module 120/230 V AC for ET200iSP, Ex db eb [ib] IIC T4 Gb, Ex db eb [ib] I Mb |Figure similar|SIMATIC, power supply module 120/230 V AC for ET200iSP, Ex db eb [ib] IIC T4<br>Gb, Ex db eb [ib] I Mb| |---|---| |**General information**|| |Product type designation|PS 120/230 V AC| |Redundancy|| |● Redundancycapability|Yes| |**Supply voltage**|| |Type of supplyvoltage|AC| |Rated value(AC)|230 V; 120/230 V AC| |permissible range, lower limit(AC)|85 V| |permissible range, upper limit(AC)|264 V| |external protection for power supply lines (recommendation)|protection with 6 A miniature circuit breaker and tripping characteristic C (per<br>ET 200iSP station)| |Line frequency|| |●permissible range, lower limit|47 Hz| |●permissible range, upper limit|63 Hz| |Mains buffering|| |● bridgingtime for backplane bus, min.|20 ms| |● bufferingtime forpowerbus, min.|20 ms| |● bufferingtime for IM 152 CPU, min.|20 ms| |**Input current**|| |Inrush current, max.|28 A; at 120/230 V AC| |from supplyvoltage L1, max.|1.04 A; at rated voltage 230 VAC:0.45A at rated voltage 120 VAC:0.75A| |At 50 Hz AC, max.|1.04 A| |At 60 Hz AC, max.|1.04 A| |**Power loss**|| |Power loss, typ.|5 W; 5 W + 1.2 x totalpower loss of the electronics modules| |Power loss, max.|21.3 W| |**Interrupts/diagnostics/status information**|| |Status indicator|Yes| |Alarms|No| |Diagnoses|| |● Diagnostic information readable|Yes; via IM 152| |Diagnostics indication LED|| |● Group error SF(red)|No| |**Ex(i) characteristics**|| |maximum values for connectingterminals forgasgroupIIC|| |● Um (voltage at non-intrinsically safe connecting<br>terminals), max.|264 V; for more AC/DC information, see certificate IECEx KEM 09.0070| |**Potential separation**|| 6ES71387EC000AA0 Page 1/3 Subject to change without notice © Copyright Siemens 5/18/2026 |primary/secondary|Yes|Yes|Yes| |---|---|---|---| |between supplyvoltage and electronics|No||| |**Degree and class of protection**|||| |IP degree of protection|IP30||| |**Standards, approvals, certificates**|||| |CE mark|CE 0344||| |UKCA mark|DEKRA 21UKEX0033 Importer UK: Siemensplc Manchester M20 2UR||| |cULus|LISTED E334384||| |FM approval|CLASSIFIED 3025852||| |BIS|Yes||| |Suitable for safetyfunctions|Yes||| |INMETRO certificate|UL-BR 12.0066||| |reference designation accordingto IEC 81346-2(2009)|K||| |Use in hazardous areas|||| |● ATEX marking|II 2 G Ex db eb[ib]IIC T4 Gb I M2 Ex db eb[ib]I Mb||| |● ATEX certificate|KEMA 09 ATEX 0156||| |● IECEx|IECEx KEM 09.0070||| |● CCC Ex|2020322303002989||| |● EAC Ex|1Ex d e[ib]IIC T4 Gb PII Ex d e[ib Mb]I Mc||| |● FM marking|Class I, Zone 1 AEx d e [ib] IIC T4 NI, Class I, DIV.2, GP. A,B,C,D T4 DIP,<br>Class II, III, GP. E,F,G||| |● Explosionprotection categoryforgas|ATEXgas explosionprotection, Zone 1||| |● Explosion protection category for dust|ATEX dust explosion protection, Zone 21 always install in corresponding<br>enclosure||| |● associated equipment(Ex ia)|No||| |● associated equipment(Ex ib)|Yes||| |Marine approval|||| |● Germanischer Lloyd(GL)|Yes||| |● American Bureau of Shipping (ABS)|Yes||| |● Bureau Veritas(BV)|Yes||| |● Det Norske Veritas(DNV)|Yes||| |**Ambient conditions**|||| |Ambient temperature duringoperation|||| |● min.|-20 °C||| |● max.|70 °C||| |**Dimensions**|||| |Width|60 mm||| |Height|190 mm||| |Depth|136.5 mm||| |**Weights**|||| |Weight, approx.|2 700g||| |**Classifications**|||| |||**Version**|**Classification**| ||eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>ETIM<br>ETIM<br>ETIM<br>ETIM<br>IDEA<br>UNSPSC|14<br>12<br>9.1<br>9<br>8<br>7.1<br>6<br>10<br>9<br>8<br>7<br>4<br>15|27-24-26-11<br>27-24-26-11<br>27-24-26-11<br>27-24-26-11<br>27-24-26-11<br>27-24-26-11<br>27-24-26-11<br>EC002583<br>EC002583<br>EC002583<br>EC002583<br>3575<br>32-15-17-06| |**Approvals / Certificates**|||| **Approvals / Certificates** 6ES71387EC000AA0 Page 2/3 Subject to change without notice © Copyright Siemens 5/18/2026 **==> picture [489 x 379] intentionally omitted <==** **----- Start of picture text -----**<br> For use in hazard-<br>General Product Approval ous locations<br>Miscellaneous<br>a ‘SeeUK Ie & ©<br>For use in hazardous locations<br>7 FM ——. Miscellaneous _ CCC-Ex<br>For use in hazardous locations Maritime application<br>x © Miscellaneous BE 6<br>Environment<br>a<br>EPD<br>last modified: 3/13/2026 (Sa<br>**----- End of picture text -----**<br> 6ES71387EC000AA0 Page 3/3 Subject to change without notice © Copyright Siemens 5/18/2026
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →