Image not available
Illustrative purposes only
6EP3436-8MB00-2CY0
Isolated DIN Rail Mount DC/DC Converter, ITE, 1:1, 12 W, 4 Output, 24 VDC, 5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Isolated DIN Rail Mount DC / DC Converters
- Depth: 150mm
- Width: 100mm
- Height: 125mm
- Input Ratio: 1:1
- Product Range: SITOP PSU8600 Series
- No. of Outputs: 4 Output
- Output Power Max: 12W
- Isolation Voltage: -
- Output Regulation: -
- Input Voltage DC Max: -
- Input Voltage DC Min: -
- Input Voltage DC Nom: -
- Output Current - Output 1: 5A
- Output Current - Output 2: 5A
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: 24VDC
- Power Supply Applications: ITE
- DC / DC Converter Output Type: Adjustable
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 622.05 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6EP3436-8MB00-2CY0** **Data sheet** SITOP PSU8600/3AC/24VDC/20A/4X5A PN SITOP PSU8600 3AC 20 A/4x5 A PN stabilized power supply input: 400-500 V 3 AC output: 24 V DC/20 A/4x 5 A with PN/IE connection web server integrated OPC UA server integrated ||SITOP PSU8600/3AC/24VDC/20A/4X5A PN<br>SITOP PSU8600 3AC 20 A/4x5 A PN stabilized power supply input: 400-500 V 3<br>AC output: 24 V DC/20 A/4x 5 A with PN/IE connection web server integrated OPC<br>UA server integrated| |---|---| |**General information**|| |Technical Product Detail Page|https://i.siemens.com/1P6EP3436-8MB00-2CY0| |**input**|| |type of thepower supplynetwork|3-phase AC| |supplyvoltage at AC|| |● minimum rated value|400 V| |● maximum rated value|500 V| |● initial value|320 V| |● full-scale value|575 V| |supplyvoltage at AC|Derating320 ... 360 and 530 ... 575 V| |wide range input|Yes| |buffering time for rated value of the output current in the event of<br>power failure minimum|15 ms| |operating condition of the mains buffering|at Vin = 400 V; Prioritized supply of Output 1 in case of power failure selectable<br>via DIP switch| |line frequency|50/60 Hz| |line frequency|47 ... 63 Hz| |input current|| |● at rated input voltage 400 V|1.4 A| |● at rated input voltage 500 V|1.1 A| |current limitation of inrush current at 25 °C maximum|14 A| |I2t value maximum|1.2 A²·s| |fuseprotection type|none| |fuse protection type in the feeder|Required: 3-pole connected miniature circuit breaker 6 ... 16 A characteristic C<br>or circuit breaker 3RV2011-1DA10(setting3 A)or 3RV2711-1DD10(UL 489)| |**output**|| |voltage curve at output|Controlled, isolated DC voltage| |number of outputs|4| |output voltage at DC rated value|24 V| |output voltage|| |● at output 1 at DC rated value|24 V| |● at output 2 at DC rated value|24 V| |● at output 3 at DC rated value|24 V| |● at output 4 at DC rated value|24 V| |output voltage adjustable|Yes; viapotentiometer or IE/PN interface| |adjustable output voltage|4 ... 28 V; Derating > 24 V: 4%/V; max. 120 W per output, max. 480 W overall<br>system| |relative overall tolerance of the voltage|3 %| |relative controlprecision of the output voltage|| |● on slow fluctuation of input voltage|0.2 %| 6EP34368MB002CY0 Page 1/5 Subject to change without notice © Copyright Siemens 6/3/2026 |● on slow fluctuation of ohm loading|0.1 %| |---|---| |residual ripple|| |● maximum|100 mV| |voltagepeak|| |● maximum|200 mV| |display version for normal operation|3-color LED for operating state device; LED for operating mode manual/remote;<br>4 LEDs for communication PROFINET; 3-color LED per output for operating<br>state output; LEDgreen forparallel operation Output 1 and 2 / 3 and 4| |type of signal at output|Relay contact (changeover contact, contact current capacity DC 60 V/0.3 A) for<br>"Operatingstate OK"| |behavior of the output voltage when switchingon|No overshoot of Vout(soft start)| |response delaymaximum|1 s; Without on-delayof the outputs| |type of outputs connection|simultaneous switch-on of all outputs after device power-up or delay time of 25<br>ms, 100 ms, or "load-optimized" for sequential switch-on of the outputs via DIP<br>switch configurable| |voltage increase time of the output voltage|| |● maximum|500 ms| |output current|| |● rated value|20 A| |●per output|5 A| |● at output 1 rated value|5 A| |● at output 2 rated value|5 A| |● at output 3 rated value|5 A| |● at output 4 rated value|5 A| |● rated range|0 ... 20 A; +50 ... +60 °C: Derating 2.5%/K; no derating in connection with<br>expansion module CNX8600 and total load of the outputs at the basic device<br>max. 240 W| |supplied activepower typical|480 W| |parallel switching of outputs|Yes; Parallel circuit Output 1 with 2 or Output 3 with 4 can be selected via DIP<br>switch| |bridgingof equipment|No| |**efficiency**|| |efficiencyinpercent|93 %| |power loss[W]|| |● at rated output voltage for rated value of the output<br>current typical|34 W| |● duringno-load operation maximum|12 W| |**closed-loop control**|| |relative control precision of the output voltage with rapid<br>fluctuation of the input voltage by+/- 15% typical|0.1 %| |relative control precision of the output voltage load step of<br>resistive load 50/100/50 % typical|0.4 %| |settingtime|| |● maximum|10 ms| |**protection and monitoring**|| |design of the overvoltageprotection|max. 35 V(max. 500 ms)| |propertyof the output short-circuitproof|Yes| |design of short-circuit protection|electronic overload cut-off; optionally constant current operation can be<br>selected for Output 4 via DIP switches| |adjustable current response value current of the current-<br>dependent overload release|0.5 ... 5 A| |type of response value setting|viapotentiometer or IE/PN interface| |switchingcharacteristic|| |● of the excess current|Ia >1.0...<1.5 x Ia threshold for 5 s permissible; Ia limit (= 1.5 x Ia threshold) for<br>200 mspermissible| |● of the current limitation|Ia limit (= 1.5 x Ia threshold) permissible for 5 s, afterwards Ia threshold<br>continuous| |overcurrent overload capability|| |● in normal operation|Total system overloadable 150% Ia rated to 5 s/min| |display version for overload and short circuit|3-color LED for operating state device; 3-color LED per output for operating<br>state output| |design of the reset device/resettingmechanism|via sensorper output or IE/PN interface| |remote reset function|non-isolated 24 V input (signal level "high" at > 15 V)| 6EP34368MB002CY0 Page 2/5 Subject to change without notice © Copyright Siemens 6/3/2026 ||**interfaces**|**interfaces**|| |---|---|---|---| ||product function communication function|Yes|| ||design of the interface|Ethernet/PROFINET|| ||● design of the interface PROFINETprotocol|Yes|| ||protocol is supported||| ||● OPC UA|Yes|| ||**safety**||| ||galvanic isolation between input and output|Yes|| ||galvanic isolation|Output voltage: SELV, ES1(IEC 62368-1), DVC As(IEC 61204-7)|| ||operatingresourceprotection class|Class I|| ||leakage current||| ||● maximum|3.5 mA|| ||protection class IP|IP20|| ||**EMC**||| ||standard||| ||● for emitted interference|EN 55022 Class B|| ||● for mains harmonics limitation|EN 61000-3-2|| ||● for interference immunity|EN 61000-6-2|| ||**standards, specifications, approvals**||| ||certificate of suitability||| ||● CE marking|Yes|| ||● UL approval|Yes; cULus-Listed(UL 508, CSA C22.2 No. 107.1), File E197259|| ||● EAC approval|Yes|| ||● NEC Class 2|No|| ||● SEMI F47|Yes|| ||type of certification||| ||● BIS|Yes; R-41188271|| ||● CB-certificate|Yes|| ||MTBF at 40 °C|243 178 h|| ||**standards, specifications, approvals hazardous environments**||| ||certificate of suitability||| ||● IECEx|No|| ||● ATEX|No|| ||● ULhazloc approval|No|| ||● FM registration|No|| ||**standards, specifications, approvals marine classification**||| ||shipbuildingapproval|Yes|| ||Marine classification association||| ||● American Bureau of ShippingEurope Ltd.(ABS)|Yes|| ||● French marine classification society (BV)|No|| ||● Det Norske Veritas(DNV)|Yes|| ||● Lloyds Register of Shipping (LRS)|No|| ||**standards, specifications, approvals Environmental Product Declaration**||| ||Environmental Product Declaration|Yes|| ||global warming potential[CO2 eq]||| ||● total|909.7 kg|| ||● duringmanufacturing|47.8 kg|| ||● duringoperation|861 kg|| ||● after end of life|0.4 kg|| ||**ambient conditions**||| ||ambient temperature||| ||● duringoperation|-25 ... +60 °C; with natural convection|| ||● duringtransport|-40 ... +85 °C|| ||● duringstorage|-40 ... +85 °C|| ||environmental categoryaccordingto IEC 60721|Climate class 3K3, 5 ... 95% no condensation|| ||**connection method**||| ||type of electrical connection|Plug-in terminals with screwed connection|| ||● at input|L1, L2, L3, PE: Plug-in terminal with 1 screwed connection each for 0.2 ... 4<br>mm² single-wire / fine stranded|| 6EP34368MB002CY0 Page 3/5 Subject to change without notice © Copyright Siemens 6/3/2026 |● at output|1, 2, 3, 4: Two plug-in terminals (1, 2 and 3, 4) with 2 screwed connections<br>each for 0.2 ... 2.5 mm²; 0 V: Plug-in terminal with 3 screwed connections for<br>0.2 ... 4 mm²|1, 2, 3, 4: Two plug-in terminals (1, 2 and 3, 4) with 2 screwed connections<br>each for 0.2 ... 2.5 mm²; 0 V: Plug-in terminal with 3 screwed connections for<br>0.2 ... 4 mm²|1, 2, 3, 4: Two plug-in terminals (1, 2 and 3, 4) with 2 screwed connections<br>each for 0.2 ... 2.5 mm²; 0 V: Plug-in terminal with 3 screwed connections for<br>0.2 ... 4 mm²| |---|---|---|---| |● for auxiliary contacts|RST (Reset): Plug-in terminal (together with alarm signal) with 1 screwed<br>connection for 0.2 ... 1.5 mm²||| |● for signaling contact|11, 12, 14 (alarm signal): Plug-in terminal (together with Reset) with 1 screwed<br>connection each for 0.2 ... 1.5 mm²||| |removable terminal at input|Yes||| |removable terminal at output|Yes||| |design of the interface for communication|PROFINET/Ethernet: two RJ45 sockets(2-port switch)||| |suitabilityfor interaction modular system|Yes||| |**mechanical data**|||| |width × height × depth of the enclosure|100 × 125 × 150 mm||| |installation width × mountingheight|100 mm × 225 mm||| |required spacing|||| |● top|50 mm||| |● bottom|50 mm||| |● left|0 mm||| |● right|0 mm||| |fasteningmethod|Snaps onto DIN rail EN 60715 35x15||| |● DIN-rail mounting|Yes||| |● S7 rail mounting|No||| |● wall mounting|No||| |housingcan be lined up|Yes||| |net weight|2 kg||| |**accessories**|||| |electrical accessories|Expansion modules CNX8600, buffer modules BUF8600, module UPS8600||| |mechanical accessories|Device identification label 20 mm × 7 mm, TI-grey3RT2900-1SB20||| |**further information internet links**|||| |internet link|||| |● to website: IndustryMall|https://mall.industry.siemens.com||| |● to webpage: selection aid TIA Selection Tool|https://www.siemens.com/tstcloud||| |● to webpage:power supplies|https://siemens.com/sitop||| |● to website: CAx-Download-Manager|https://siemens.com/cax||| |● to website: IndustryOnline Support|https://support.industry.siemens.com||| |**additional information**|||| |other information|Specifications at rated input voltage and ambient temperature +25 °C (unless<br>otherwise specified)||| |**security information**|||| |security information|Siemens provides products and solutions with industrial cybersecurity functions<br>that support the secure operation of plants, systems, machines and networks.<br>In order to protect plants, systems, machines and networks against cyber<br>threats, it is necessary to implement - and continuously maintain - a holistic,<br>state-of-the-art industrial cybersecurity concept. Siemens’ products and<br>solutions constitute one element of such a concept. Customers are responsible<br>for preventing unauthorized access to their plants, systems, machines and<br>networks. Such systems, machines and components should only be connected<br>to an enterprise network or the internet if and to the extent such a connection is<br>necessary and only when appropriate security measures (e.g. firewalls and/or<br>network segmentation) are in place. For additional information on industrial<br>cybersecurity measures that may be implemented, please visit<br>www.siemens.com/cybersecurity-industry. Siemens’ products and solutions<br>undergo continuous development to make them more secure. Siemens strongly<br>recommends that product updates are applied as soon as they are available<br>and that the latest product versions are used. Use of product versions that are<br>no longer supported, and failure to apply the latest updates may increase<br>customer’s exposure to cyber threats. To stay informed about product updates,<br>subscribe to the Siemens Industrial Cybersecurity RSS Feed under<br>https://www.siemens.com/cert.(V4.7)||| |**Classifications**|||| |||**Version**|**Classification**| ||eClass<br>eClass<br>eClass|14<br>12<br>9.1|27-04-07-01<br>27-04-07-01<br>27-04-07-01| 6EP34368MB002CY0 Page 4/5 Subject to change without notice © Copyright Siemens 6/3/2026 eClass 9 27-04-07-01 eClass 8 27-04-90-02 eClass 7.1 27-04-90-02 eClass 6 27-04-90-02 ETIM 10 EC002540 ETIM 9 EC002540 ETIM 8 EC002540 ETIM 7 EC002540 IDEA 4 4130 UNSPSC 15 39-12-10-04 **Approvals Certificates** ~~ee~~ Environmental Product Declaration ● global warming potential [CO2 eq] / during manufacturing 47.8 kg ● global warming potential [CO2 eq] / during operation 861 kg ● global warming potential [CO2 eq] / after end of life 0.4 kg ● global warming potential [CO2 eq] / total 909.7 kg **Environment General Product Approval** Manufacturer DeclaraDeclaration of Con- ~~:~~ tion formity : EPD CB cA C€“- **General Product Approval Maritime application** China RoHS BIS CRS ## **Industrial Communication** ## PROFINET **last modified:** 5/5/2026 6EP34368MB002CY0 Page 5/5 Subject to change without notice © Copyright Siemens 6/3/2026
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →