Image not available
Illustrative purposes only
6EP3336-8MB00-2CY0
Isolated DIN Rail Mount DC/DC Converter, ITE, 2:1, 14 W, 4 Output, 24 VDC, 5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Isolated DIN Rail Mount DC / DC Converters
- Depth: 150mm
- Width: 125mm
- Height: 125mm
- Input Ratio: 2:1
- Product Range: SITOP PSU8600 Series
- No. of Outputs: 4 Output
- Output Power Max: 14W
- Isolation Voltage: -
- Output Regulation: -
- Input Voltage DC Max: 275V
- Input Voltage DC Min: 93V
- Input Voltage DC Nom: -
- Output Current - Output 1: 5A
- Output Current - Output 2: 5A
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: 24VDC
- Power Supply Applications: ITE
- DC / DC Converter Output Type: Adjustable
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 578.85 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6EP3336-8MB00-2CY0** **Data sheet** SITOP PSU8600/1AC/24VDC/20A/4X5A PN SITOP PSU8600 1AC 20 A/4x5 A PN stabilized power supply input: 100-240 V AC output: 24 V DC/20 A/4x 5 A with PN/IE connection web server integrated OPC UA server integrated ## **General information** |a<br>:<br>|<br>i<br>||SITOP PSU8600/1AC/24VDC/20A/4X5A PN<br>SITOP PSU8600 1AC 20 A/4x5 A PN stabilized power supply input: 100-240 V AC<br>output: 24 V DC/20 A/4x 5 A with PN/IE connection web server integrated OPC UA<br>server integrated| |---|---| |**General information**|| |Technical Product Detail Page|https://i.siemens.com/1P6EP3336-8MB00-2CY0| |**input**|| |type of thepower supplynetwork|1-phase and 2-phase AC or DC| |supplyvoltage at AC|| |● minimum rated value|100 V| |● maximum rated value|240 V| |● initial value|85 V| |● full-scale value|275 V| |supplyvoltage at DC|110 ... 220 V| |input voltage at DC|93 ... 275 V| |wide range input|Yes| |buffering time for rated value of the output current in the event of<br>power failure minimum|20 ms| |operating condition of the mains buffering|at Vin = 100 V; Prioritized supply of Output 1 in case of power failure selectable<br>via DIP switch| |line frequency|50/60 Hz| |line frequency|47 ... 63 Hz| |input current|| |● at rated input voltage 100 V|5.4 A| |● at rated input voltage 110 V|4.8 A| |● at rated input voltage 120 V|4.5 A| |● at rated input voltage 220 V|2.4 A| |● at rated input voltage 230 V|2.5 A| |● at rated input voltage 240 V|2.4 A| |current limitation of inrush current at 25 °C maximum|15 A| |I2t value maximum|4.33 A²·s| |fuseprotection type|internal| |fuse protection type in the feeder|required: circuit breaker (for UL: UL489-listed/DIVQ) characteristic C, 10-32 A,<br>alternativelyslow-response fuses(for UL: UL248-listed)| |**output**|| |voltage curve at output|Controlled, isolated DC voltage| |number of outputs|4| |output voltage at DC rated value|24 V| |output voltage|| |● at output 1 at DC rated value|24 V| |● at output 2 at DC rated value|24 V| |● at output 3 at DC rated value|24 V| |● at output 4 at DC rated value|24 V| 6EP33368MB002CY0 Page 1/5 Subject to change without notice © Copyright Siemens 5/18/2026 ||output voltage adjustable|Yes; viapotentiometer or IE/PN interface|| |---|---|---|---| ||adjustable output voltage|4 ... 28 V; Derating > 24 V: 4%/V; max. 120 W per output, max. 480 W overall<br>system|| ||relative overall tolerance of the voltage|3 %|| ||relative controlprecision of the output voltage||| ||● on slow fluctuation of input voltage|0.2 %|| ||● on slow fluctuation of ohm loading|0.1 %|| ||residual ripple||| ||● maximum|100 mV|| ||voltagepeak||| ||● maximum|200 mV|| ||display version for normal operation|3-color LED for operating state device; LED for operating mode manual/remote;<br>4 LEDs for communication PROFINET; 3-color LED per output for operating<br>state output; LEDgreen forparallel operation Output 1 and 2 / 3 and 4|| ||type of signal at output|Relay contact (changeover contact, contact current capacity DC 60 V/0.3 A) for<br>"Operatingstate OK"|| ||behavior of the output voltage when switchingon|No overshoot of Vout(soft start)|| ||response delaymaximum|1 s; Without on-delayof the outputs|| ||type of outputs connection|simultaneous switch-on of all outputs after device power-up or delay time of 25<br>ms, 100 ms, or "load-optimized" for sequential switch-on of the outputs via DIP<br>switch configurable|| ||voltage increase time of the output voltage||| ||● maximum|500 ms|| ||output current||| ||● rated value|20 A|| ||●per output|5 A|| ||● at output 1 rated value|5 A|| ||● at output 2 rated value|5 A|| ||● at output 3 rated value|5 A|| ||● at output 4 rated value|5 A|| ||● rated range|0 ... 20 A|| ||supplied activepower typical|480 W|| ||parallel switching of outputs|Yes; Parallel circuit Output 1 with 2 or Output 3 with 4 can be selected via DIP<br>switch|| ||bridgingof equipment|No|| ||**efficiency**||| ||efficiencyinpercent|92 %|| ||power loss[W]||| ||● at rated output voltage for rated value of the output<br>current typical|39 W|| ||● duringno-load operation maximum|14 W|| ||**closed-loop control**||| ||relative control precision of the output voltage with rapid<br>fluctuation of the input voltage by+/- 15% typical|0.1 %|| ||relative control precision of the output voltage load step of<br>resistive load 50/100/50 % typical|0.4 %|| ||settingtime||| ||● maximum|10 ms|| ||**protection and monitoring**||| ||design of the overvoltageprotection|max. 35 V(max. 500 ms)|| ||propertyof the output short-circuitproof|Yes|| ||design of short-circuit protection|electronic overload cut-off; optionally constant current operation can be<br>selected for Output 4 via DIP switches|| ||adjustable current response value current of the current-<br>dependent overload release|0.5 ... 5 A|| ||type of response value setting|viapotentiometer or IE/PN interface|| ||switchingcharacteristic||| ||● of the excess current|Ia >1.0...<1.5 x Ia threshold for 5 s permissible; Ia limit (= 1.5 x Ia threshold) for<br>200 mspermissible|| ||● of the current limitation|Ia limit (= 1.5 x Ia threshold) permissible for 5 s, afterwards Ia threshold<br>continuous|| ||overcurrent overload capability||| ||● in normal operation|Total system overloadable 150% Ia rated to 5 s/min|| 6EP33368MB002CY0 Page 2/5 Subject to change without notice © Copyright Siemens 5/18/2026 ||display version for overload and short circuit|3-color LED for operating state device; 3-color LED per output for operating<br>state output|| |---|---|---|---| ||design of the reset device/resettingmechanism|via sensorper output or IE/PN interface|| ||remote reset function|non-isolated 24 V input(signal level "high" at > 15 V)|| ||**interfaces**||| ||product function communication function|Yes|| ||design of the interface|Ethernet/PROFINET|| ||● design of the interface PROFINETprotocol|Yes|| ||protocol is supported||| ||● OPC UA|Yes|| ||**safety**||| ||galvanic isolation between input and output|Yes|| ||galvanic isolation|Output voltage: SELV, ES1(IEC 62368-1), DVC As(IEC 61204-7)|| ||operatingresourceprotection class|Class I|| ||leakage current||| ||● maximum|3.5 mA|| ||protection class IP|IP20|| ||**EMC**||| ||standard||| ||● for emitted interference|EN 55022 Class B|| ||● for mains harmonics limitation|EN 61000-3-2|| ||● for interference immunity|EN 61000-6-2|| ||**standards, specifications, approvals**||| ||certificate of suitability||| ||● CE marking|Yes|| ||● UL approval|Yes; cULus-Listed(UL 508, CSA C22.2 No. 107.1), File E197259|| ||● EAC approval|Yes|| ||● NEC Class 2|No|| ||● SEMI F47|Yes|| ||type of certification||| ||● BIS|Yes; R-41188271|| ||● CB-certificate|Yes|| ||MTBF at 40 °C|186 700 h|| ||**standards, specifications, approvals hazardous environments**||| ||certificate of suitability||| ||● IECEx|No|| ||● ATEX|No|| ||● ULhazloc approval|No|| ||● FM registration|No|| ||**standards, specifications, approvals marine classification**||| ||shipbuildingapproval|Yes|| ||Marine classification association||| ||● American Bureau of ShippingEurope Ltd.(ABS)|Yes|| ||● French marine classification society (BV)|No|| ||● Det Norske Veritas(DNV)|No|| ||● Lloyds Register of Shipping (LRS)|No|| ||**standards, specifications, approvals Environmental Product Declaration**||| ||Environmental Product Declaration|Yes|| ||global warming potential[CO2 eq]||| ||● total|1 051 kg|| ||● duringmanufacturing|62.2 kg|| ||● duringoperation|987.6 kg|| ||● after end of life|0.52 kg|| ||**ambient conditions**||| ||ambient temperature||| ||● duringoperation|-25 ... +60 °C; with natural convection|| ||● duringtransport|-40 ... +85 °C|| ||● duringstorage|-40 ... +85 °C|| ||environmental category according to IEC 60721|Climate class 3K3, 5 ... 95% no condensation|| 6EP33368MB002CY0 Page 3/5 Subject to change without notice © Copyright Siemens 5/18/2026 |**connection method**|||| |---|---|---|---| |type of electrical connection|Plug-in terminals with screwed connection||| |● at input|L1/+, N/L2/-, PE: Plug-in terminal with 1 screwed connection each for 0.2 ... 4<br>mm² single-wire / fine stranded||| |● at output|1, 2, 3, 4: Two plug-in terminals (1, 2 and 3, 4) with 2 screwed connections<br>each for 0.2 ... 2.5 mm²; 0 V: Plug-in terminal with 3 screwed connections for<br>0.2 ... 4 mm²||| |● for auxiliary contacts|RST (Reset): Plug-in terminal (together with alarm signal) with 1 screwed<br>connection for 0.2 ... 1.5 mm²||| |● for signaling contact|11, 12, 14 (alarm signal): Plug-in terminal (together with Reset) with 1 screwed<br>connection each for 0.2 ... 1.5 mm²||| |removable terminal at input|Yes||| |removable terminal at output|Yes||| |design of the interface for communication|PROFINET/Ethernet: two RJ45 sockets(2-port switch)||| |suitabilityfor interaction modular system|Yes||| |**mechanical data**|||| |width × height × depth of the enclosure|125 × 125 × 150 mm||| |installation width × mountingheight|125 mm × 225 mm||| |required spacing|||| |● top|50 mm||| |● bottom|50 mm||| |● left|0 mm||| |● right|0 mm||| |fasteningmethod|Snaps onto DIN rail EN 60715 35x15||| |● DIN-rail mounting|Yes||| |● S7 rail mounting|No||| |● wall mounting|No||| |housingcan be lined up|Yes||| |net weight|2.6 kg||| |**accessories**|||| |electrical accessories|Expansion modules CNX8600, buffer modules BUF8600, module UPS8600||| |mechanical accessories|Device identification label 20 mm × 7 mm, TI-grey3RT2900-1SB20||| |**further information internet links**|||| |internet link|||| |● to website: IndustryMall|https://mall.industry.siemens.com||| |● to webpage: selection aid TIA Selection Tool|https://www.siemens.com/tstcloud||| |● to webpage:power supplies|https://siemens.com/sitop||| |● to website: CAx-Download-Manager|https://siemens.com/cax||| |● to website: IndustryOnline Support|https://support.industry.siemens.com||| |**additional information**|||| |other information|Specifications at rated input voltage and ambient temperature +25 °C (unless<br>otherwise specified)||| |**security information**|||| |security information|Siemens provides products and solutions with industrial cybersecurity functions<br>that support the secure operation of plants, systems, machines and networks.<br>In order to protect plants, systems, machines and networks against cyber<br>threats, it is necessary to implement - and continuously maintain - a holistic,<br>state-of-the-art industrial cybersecurity concept. Siemens’ products and<br>solutions constitute one element of such a concept. Customers are responsible<br>for preventing unauthorized access to their plants, systems, machines and<br>networks. Such systems, machines and components should only be connected<br>to an enterprise network or the internet if and to the extent such a connection is<br>necessary and only when appropriate security measures (e.g. firewalls and/or<br>network segmentation) are in place. For additional information on industrial<br>cybersecurity measures that may be implemented, please visit<br>www.siemens.com/cybersecurity-industry. Siemens’ products and solutions<br>undergo continuous development to make them more secure. Siemens strongly<br>recommends that product updates are applied as soon as they are available<br>and that the latest product versions are used. Use of product versions that are<br>no longer supported, and failure to apply the latest updates may increase<br>customer’s exposure to cyber threats. To stay informed about product updates,<br>subscribe to the Siemens Industrial Cybersecurity RSS Feed under<br>https://www.siemens.com/cert.(V4.7)||| |**Classifications**|||| |||**Version**|**Classification**| 6EP33368MB002CY0 Page 4/5 Subject to change without notice © Copyright Siemens 5/18/2026 |eClass|14|27-04-07-01| |---|---|---| |eClass|12|27-04-07-01| |eClass|9.1|27-04-07-01| |eClass|9|27-04-07-01| |eClass|8|27-04-90-02| |eClass|7.1|27-04-90-02| |eClass|6|27-04-90-02| |ETIM|10|EC002540| |ETIM|9|EC002540| |ETIM|8|EC002540| |ETIM|7|EC002540| |IDEA|4|4130| |UNSPSC|15|39-12-10-04| **Approvals Certificates** Environmental Product Declaration ● global warming potential [CO2 eq] / during manufacturing 62.2 kg ● global warming potential [CO2 eq] / during operation 987.6 kg ● global warming potential [CO2 eq] / after end of life 0.52 kg ● global warming potential [CO2 eq] / total 1051 kg **Environment General Product Approval** Manufacturer DeclaraDeclaration of Con- ~~__~~ tion formity ~~ae~~ m C ~~~~~~ eq ¢é **Industrial CommuGeneral Product Approval Maritime application nication** ~~es —~~ China RoHS OS ~— BIS CRS @ ~~a~~ PROFINET **last modified:** 5/5/2026 6EP33368MB002CY0 Page 5/5 Subject to change without notice © Copyright Siemens 5/18/2026
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →