Image not available
Illustrative purposes only
6EP3234-0TA00-0AY0
Isolated DIN Rail Mount DC/DC Converter, ITE, 2:1, 256 W, 1 Output, 24 V, 10 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Isolated DIN Rail Mount DC / DC Converters
- SVHC: To Be Advised
- Depth: 120mm
- Width: 42mm
- Height: 125mm
- Input Ratio: 2:1
- Product Range: SITOP PSU3400 Series
- No. of Outputs: 1 Output
- Output Power Max: 256W
- Isolation Voltage: -
- Output Regulation: -
- Input Voltage DC Max: 60V
- Input Voltage DC Min: 28V
- Input Voltage DC Nom: 48V
- Output Current - Output 1: 10A
- Output Current - Output 2: -
- Output Voltage - Output 1: 24V
- Output Voltage - Output 2: -
- Power Supply Applications: ITE
- DC / DC Converter Output Type: Fixed, Adjustable
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 200.97 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6EP3234-0TA00-0AY0** **Data sheet** SITOP PSU3400/DC/DC/48V/24V/10A SITOP PSU3400 24 V/10 A Stabilized power supply Input: 48 V DC (28…60 V) Output: 24 V DC/10 A ## **General information** |Siemens~~@~~<br>EcoTech|SITOP PSU3400/DC/DC/48V/24V/10A<br>SITOP PSU3400 24 V/10 A Stabilized power supply Input: 48 V DC (28…60 V)<br>Output: 24 V DC/10 A| |---|---| |**General information**|| |Technical Product Detail Page|https://i.siemens.com/1P6EP3234-0TA00-0AY0| |**input**|| |type of thepower supplynetwork|DC voltage| |supplyvoltage at AC|Startupas of 36 V, deratingnecessaryfor 28 ... 36 V DC| |supplyvoltage at DC|48 V| |input voltage at DC|28 ... 60 V| |wide range input|No| |overvoltage overload capability|-| |buffering time for rated value of the output current in the event of<br>power failure minimum|5 ms| |operatingcondition of the mains buffering|at Vin = 48 V| |input current|| |● at rated input voltage 48 V|5.4 A| |current limitation of inrush current at 25 °C maximum|15 A| |I2t value maximum|0.5 A²·s| |fuseprotection type|15 A(not accessible), breakingcapacity100 A| |fuse protection type in the feeder|Recommended miniature circuit breaker: 16 A characteristic B or C| |**output**|| |voltage curve at output|Controlled, isolated DC voltage| |output voltage at DC rated value|24 V| |output voltage|| |● at output 1 at DC rated value|24 V| |output voltage adjustable|Yes; viapotentiometer| |adjustable output voltage|24 ... 28 V| |relative overall tolerance of the voltage|1 %| |relative controlprecision of the output voltage|| |● on slow fluctuation of input voltage|0.1 %| |● on slow fluctuation of ohm loading|0.3 %| |residual ripple|| |● maximum|150 mV| |● typical|50 mV| |voltagepeak|| |● maximum|250 mV| |● typical|70 mV| |display version for normal operation|Green LED for 24 V OK| Subject to change without notice © Copyright Siemens 6EP32340TA000AY0 Page 1/4 6/1/2026 ||type of signal at output|Relay contact (NO contact, contact rating 30 V AC/0.5 A; 60 V DC/0.3 A; 30 V<br>DC/1 A)for 24 V O.K.|| |---|---|---|---| ||behavior of the output voltage when switchingon|No overshoot of Vout(soft start)|| ||response delaymaximum|0.5 s|| ||voltage increase time of the output voltage||| ||● typical|10 ms|| ||● maximum|20 ms|| ||output current||| ||● rated value|10 A|| ||● rated range|0 ... 12.5 A; 12 A upto +40°C; +60 ... +70 °C: Derating2%/K|| ||supplied activepower typical|256 W|| ||bridgingof equipment|Yes|| ||number of parallel-switched equipment resources for increasing<br>the power|2|| ||**efficiency**||| ||efficiencyinpercent|93.5 %|| ||power loss[W]||| ||● at rated output voltage for rated value of the output<br>current typical|17 W|| ||● duringno-load operation maximum|1.5 W|| ||**closed-loop control**||| ||relative control precision of the output voltage with rapid<br>fluctuation of the input voltage by+/- 15% typical|0.3 %|| ||relative control precision of the output voltage load step of<br>resistive load 50/100/50 % typical|2 %|| ||settingtime||| ||● load step50 to 100% typical|1 ms|| ||● load step 100 to 50% typical|1 ms|| ||**protection and monitoring**||| ||design of the overvoltageprotection|Ua < 35 V|| ||propertyof the output short-circuitproof|Yes|| ||design of short-circuitprotection|Electronic shutdown, automatic restart|| ||● typical|13 A|| ||displayversion for overload and short circuit|LEDyellow for "overload"|| ||**safety**||| ||galvanic isolation between input and output|Yes|| ||galvanic isolation|Output voltage: SELV, ES1(IEC 62368-1), DVC As(IEC 61204-7)|| ||operatingresourceprotection class|Class III|| ||protection class IP|IP20|| ||**EMC**||| ||standard||| ||● for emitted interference|EN 61000-6-3|| ||● for mains harmonics limitation|not applicable|| ||● for interference immunity|EN 61000-6-2|| ||**standards, specifications, approvals**||| ||certificate of suitability||| ||● CE marking|Yes|| ||● UL approval|Yes; cULus-Listed(UL 508, CSA C22.2 No. 107.1), File E197259|| ||● EAC approval|Yes|| ||● RegulatoryCompliance Mark(RCM)|Yes|| ||● NEC Class 2|No|| ||type of certification||| ||● CB-certificate|Yes|| ||MTBF at 40 °C|1 552 337 h|| ||**standards, specifications, approvals hazardous environments**||| ||certificate of suitability||| ||● IECEx|No|| ||● ATEX|No|| ||● ULhazloc approval|No|| ||● FM registration|No|| Subject to change without notice © Copyright Siemens 6EP32340TA000AY0 Page 2/4 6/1/2026 ||**standards, specifications, approvals marine classification**|**standards, specifications, approvals marine classification**|| |---|---|---|---| ||shipbuildingapproval|Yes|| ||Marine classification association||| ||● American Bureau of ShippingEurope Ltd.(ABS)|Yes|| ||● French marine classification society (BV)|No|| ||● Det Norske Veritas(DNV)|Yes|| ||● Lloyds Register of Shipping (LRS)|No|| ||**ambient conditions**||| ||ambient temperature||| ||● duringoperation|-25 ... +70 °C; with natural convection|| ||● duringtransport|-40 ... +85 °C|| ||● duringstorage|-40 ... +85 °C|| ||environmental categoryaccordingto IEC 60721|Climate class 3K3, 5 ... 95% no condensation|| ||**connection method**||| ||type of electrical connection|screw terminal|| ||● at input|L, N, FE: 1 screw terminal each for 0.5 ... 2.5 mm² single-core/finelystranded|| ||● at output|+, -: 2 screw terminals each for 0.5 ... 2.5 mm²|| ||● for auxiliarycontacts|Alarm signals: 2 screw terminals for 0.5 ... 2.5 mm²|| ||● for signalingcontact|2 screw terminals for 0.5 ... 2.5 mm²|| ||**mechanical data**||| ||width × height × depth of the enclosure|42 × 125 × 120 mm|| ||installation width × mountingheight|42 mm × 225 mm|| ||required spacing||| ||● top|50 mm|| ||● bottom|50 mm|| ||● left|0 mm|| ||● right|0 mm|| ||fasteningmethod|Snaps onto DIN rail EN 60715 35x7.5/15|| ||● DIN-rail mounting|Yes|| ||● S7 rail mounting|No|| ||● wall mounting|No|| ||housingcan be lined up|Yes|| ||net weight|0.6 kg|| ||**accessories**||| ||electrical accessories|Buffer module|| ||**further information internet links**||| ||internet link||| ||● to website: IndustryMall|https://mall.industry.siemens.com|| ||● to webpage: selection aid TIA Selection Tool|https://www.siemens.com/tstcloud|| ||● to webpage:power supplies|https://siemens.com/sitop|| ||● to website: CAx-Download-Manager|https://siemens.com/cax|| ||● to website: IndustryOnline Support|https://support.industry.siemens.com|| ||**additional information**||| ||other information|Specifications at rated input voltage and ambient temperature +25 °C (unless<br>otherwise specified)|| ||**security information**||| ||security information|Siemens provides products and solutions with industrial cybersecurity functions<br>that support the secure operation of plants, systems, machines and networks.<br>In order to protect plants, systems, machines and networks against cyber<br>threats, it is necessary to implement - and continuously maintain - a holistic,<br>state-of-the-art industrial cybersecurity concept. Siemens’ products and<br>solutions constitute one element of such a concept. Customers are responsible<br>for preventing unauthorized access to their plants, systems, machines and<br>networks. Such systems, machines and components should only be connected<br>to an enterprise network or the internet if and to the extent such a connection is<br>necessary and only when appropriate security measures (e.g. firewalls and/or<br>network segmentation) are in place. For additional information on industrial<br>cybersecurity measures that may be implemented, please visit<br>www.siemens.com/cybersecurity-industry. Siemens’ products and solutions<br>undergo continuous development to make them more secure. Siemens strongly<br>recommends that product updates are applied as soon as they are available<br>and that the latest product versions are used. Use of product versions that are<br>no longer supported, and failure to apply the latest updates may increase<br>customer’s exposure to cyber threats. To stay informed about product updates,|| Subject to change without notice © Copyright Siemens 6EP32340TA000AY0 Page 3/4 6/1/2026 subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7) |**Classifications**<br>~~a~~|**Classifications**<br>~~a~~|**Classifications**<br>~~a~~|**Classifications**<br>~~a~~|**Classifications**<br>~~a~~|**Classifications**<br>~~a~~| |---|---|---|---|---|---| ||||||**Version**<br>**Classification**| ||||eClass||14<br>27-04-07-01| ||||eClass||12<br>27-04-07-01| ||||eClass||9.1<br>27-04-07-01| ||||eClass||9<br>27-04-07-01| ||||eClass||8<br>27-04-90-02| ||||eClass||7.1<br>27-04-90-02| ||||eClass||6<br>27-04-90-02| ||||ETIM||10<br>EC002540| ||||ETIM||9<br>EC002540| ||||ETIM||8<br>EC002540| ||||ETIM||7<br>EC002540| ||||IDEA||4<br>4130| ||||UNSPSC||15<br>39-12-10-04| |**Approvals Certificates**<br>~~a~~|~~a~~|~~a~~|~~a~~|~~a~~|~~a~~| |**Environment**||**General Product Approval**|||| |~~»~~|~~»~~<br>as©||~~»~~<br>8B|~~»~~|Manufacturer Declara-<br>tion<br>~~»~~<br>&<br>~~|~~| |**General Product Approval**|||**EMV**||**For use in hazardous locations**| |c|es|([|||CCC-Ex<br>~~_~~| ~~a~~ **Approvals Certificates Environment General Product Approval** Manufacturer Declaration ~~»~~ as © 8B & ~~|~~ **last modified:** 5/5/2026 Subject to change without notice © Copyright Siemens 6EP32340TA000AY0 Page 4/4 6/1/2026
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →