6EP3133-0TA10-0AY0
Isolated DIN Rail Mount DC/DC Converter, ITE, 2:1, 108 W, 1 Output, 24 V, 4 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Isolated DIN Rail Mount DC / DC Converters
- SVHC: To Be Advised
- Depth: 100mm
- Width: 32mm
- Height: 100mm
- Input Ratio: 2:1
- Product Range: SITOP PSU3400 Series
- No. of Outputs: 1 Output
- Output Power Max: 108W
- Isolation Voltage: -
- Output Regulation: -
- Input Voltage DC Max: 18V
- Input Voltage DC Min: 9V
- Input Voltage DC Nom: 12V
- Output Current - Output 1: 4A
- Output Current - Output 2: -
- Output Voltage - Output 1: 24V
- Output Voltage - Output 2: -
- Power Supply Applications: ITE
- DC / DC Converter Output Type: Fixed, Adjustable
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 140.07 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6EP3133-0TA10-0AY0** **Data sheet** SITOP PSU3400/DC/DC/12V/24V/4A SITOP PSU3400 24 V/4 A Stabilized power supply Input: DC 12 V (9...18 V) Output: DC 24 V/4 A ||SITOP PSU3400/DC/DC/12V/24V/4A<br>SITOP PSU3400 24 V/4 A Stabilized power supply Input: DC 12 V (9...18 V)<br>Output: DC 24 V/4 A| |---|---| |**General information**|| |Technical Product Detail Page<br>~~|~~|https://i.siemens.com/1P6EP3133-0TA10-0AY0<br>~~|~~| |**input**<br>~~|~~|| |type of thepower supplynetwork<br>~~|~~|DC voltage<br>~~|~~| |supplyvoltage at DC|12 V| |input voltage at DC|9 ... 18 V| |wide range input|No| |overvoltage overload capability|-| |buffering time for rated value of the output current in the event of<br>power failure minimum|2 ms| |operatingcondition of the mains buffering|at Vin = 12 V| |input current|| |● at rated input voltage 24 V|9 A| |current limitation of inrush current at 25 °C maximum|15 A| |I2t value maximum|0.08 A²·s| |fuseprotection type|25 A(not accessible), breakingcapacity300 A| |fuse protection type in the feeder|Recommended miniature circuit breaker: 16 A characteristic B or C| |**output**<br>~~a~~|| |voltage curve at output<br>~~a~~|Controlled, isolated DC voltage<br>~~a~~| |output voltage at DC rated value|24 V| |output voltage|| |● at output 1 at DC rated value|24 V| |output voltage adjustable|Yes; viapotentiometer| |adjustable output voltage|24 ... 28 V| |relative overall tolerance of the voltage|2 %| |relative controlprecision of the output voltage|| |● on slow fluctuation of input voltage|0.1 %| |● on slow fluctuation of ohm loading|0.6 %| |residual ripple|| |● maximum|150 mV| |● typical|20 mV| |voltagepeak|| |● maximum|250 mV| |● typical|40 mV| |displayversion for normal operation|Green LED for 24 V OK| |behavior of the output voltage when switchingon|No overshoot of Vout(soft start)| |response delaymaximum|0.5 s| |voltage increase time of the output voltage|| |● typical|10 ms| Subject to change without notice © Copyright Siemens 6EP31330TA100AY0 Page 1/4 5/18/2026 |● maximum|20 ms| |---|---| |output current|| |● rated value|4 A| |● rated range|0 ... 4 A; +60 ... +70 °C: Derating2%/K| |supplied activepower typical|108 W| |bridgingof equipment|Yes| |number of parallel-switched equipment resources for increasing<br>the power|2| |**efficiency**|| |efficiencyinpercent|89 %| |power loss[W]|| |● at rated output voltage for rated value of the output<br>current typical|12 W| |● duringno-load operation maximum|1.5 W| |**closed-loop control**|| |relative control precision of the output voltage with rapid<br>fluctuation of the input voltage by+/- 15% typical|0.3 %| |relative control precision of the output voltage load step of<br>resistive load 50/100/50 % typical|2 %| |settingtime|| |● load step50 to 100% typical|1 ms| |● load step 100 to 50% typical|1 ms| |**protection and monitoring**|| |design of the overvoltageprotection|Ua < 35 V| |propertyof the output short-circuitproof|Yes| |design of short-circuitprotection|Electronic shutdown, automatic restart| |● typical|4.5 A| |displayversion for overload and short circuit|LEDyellow for "overload"| |**safety**|| |galvanic isolation between input and output|Yes| |galvanic isolation|Output voltage: SELV, ES1(IEC 62368-1), DVC As(IEC 61204-7)| |operatingresourceprotection class|Class III| |protection class IP|IP20| |**EMC**|| |standard|| |● for emitted interference|EN 61000-6-3| |● for mains harmonics limitation|not applicable| |● for interference immunity|EN 61000-6-2| |**standards, specifications, approvals**|| |certificate of suitability|| |● CE marking|Yes| |● UL approval|Yes; cULus-Listed(UL 508, CSA C22.2 No. 107.1), File E197259| |● EAC approval|Yes| |● RegulatoryCompliance Mark(RCM)|Yes| |● NEC Class 2|No| |type of certification|| |● CB-certificate|Yes| |MTBF at 40 °C|1 868 914 h| |**standards, specifications, approvals hazardous environments**|| |certificate of suitability|| |● IECEx|No| |● ATEX|No| |● ULhazloc approval|No| |● FM registration|No| |**standards, specifications, approvals marine classification**|| |shipbuildingapproval|Yes| |Marine classification association|| |● American Bureau of ShippingEurope Ltd.(ABS)|Yes| |● French marine classification society (BV)|No| Subject to change without notice © Copyright Siemens 6EP31330TA100AY0 Page 2/4 5/18/2026 |● Det Norske Veritas(DNV)|Yes|Yes|Yes| |---|---|---|---| |● Lloyds Register of Shipping (LRS)|No||| |**ambient conditions**|||| |ambient temperature|||| |● duringoperation|-25 ... +70 °C; with natural convection||| |● duringtransport|-40 ... +85 °C||| |● duringstorage|-40 ... +85 °C||| |environmental categoryaccordingto IEC 60721|Climate class 3K3, 5 ... 95% no condensation||| |**connection method**|||| |type of electrical connection|screw terminal||| |● at input|L, N, FE: 1 screw terminal each for 0.5 ... 2.5 mm² single-core/finelystranded||| |● at output|+, -: 2 screw terminals each for 0.5 ... 2.5 mm²||| |**mechanical data**|||| |width × height × depth of the enclosure|32 × 100 × 100 mm||| |installation width × mountingheight|32 mm × 200 mm||| |required spacing|||| |● top|50 mm||| |● bottom|50 mm||| |● left|0 mm||| |● right|0 mm||| |fasteningmethod|Snaps onto DIN rail EN 60715 35x7.5/15||| |● DIN-rail mounting|Yes||| |● S7 rail mounting|No||| |● wall mounting|No||| |housingcan be lined up|Yes||| |net weight|0.32 kg||| |**accessories**|||| |electrical accessories|Buffer module||| |**further information internet links**|||| |internet link|||| |● to website: IndustryMall|https://mall.industry.siemens.com||| |● to webpage: selection aid TIA Selection Tool|https://www.siemens.com/tstcloud||| |● to webpage:power supplies|https://siemens.com/sitop||| |● to website: CAx-Download-Manager|https://siemens.com/cax||| |● to website: IndustryOnline Support|https://support.industry.siemens.com||| |**additional information**|||| |other information|Specifications at rated input voltage and ambient temperature +25 °C (unless<br>otherwise specified)||| |**security information**|||| |security information|Siemens provides products and solutions with industrial cybersecurity functions<br>that support the secure operation of plants, systems, machines and networks.<br>In order to protect plants, systems, machines and networks against cyber<br>threats, it is necessary to implement - and continuously maintain - a holistic,<br>state-of-the-art industrial cybersecurity concept. Siemens’ products and<br>solutions constitute one element of such a concept. Customers are responsible<br>for preventing unauthorized access to their plants, systems, machines and<br>networks. Such systems, machines and components should only be connected<br>to an enterprise network or the internet if and to the extent such a connection is<br>necessary and only when appropriate security measures (e.g. firewalls and/or<br>network segmentation) are in place. For additional information on industrial<br>cybersecurity measures that may be implemented, please visit<br>www.siemens.com/cybersecurity-industry. Siemens’ products and solutions<br>undergo continuous development to make them more secure. Siemens strongly<br>recommends that product updates are applied as soon as they are available<br>and that the latest product versions are used. Use of product versions that are<br>no longer supported, and failure to apply the latest updates may increase<br>customer’s exposure to cyber threats. To stay informed about product updates,<br>subscribe to the Siemens Industrial Cybersecurity RSS Feed under<br>https://www.siemens.com/cert.(V4.7)||| |**Classifications**|||| |||**Version**|**Classification**| ||eClass<br>eClass|14<br>12|27-04-07-01<br>27-04-07-01| Subject to change without notice © Copyright Siemens 6EP31330TA100AY0 Page 3/4 5/18/2026 |eClass|9.1|27-04-07-01| |---|---|---| |eClass|9|27-04-07-01| |eClass|8|27-04-90-02| |eClass|7.1|27-04-90-02| |eClass|6|27-04-90-02| |ETIM|10|EC002540| |ETIM|9|EC002540| |ETIM|8|EC002540| |ETIM|7|EC002540| |IDEA|4|4130| |UNSPSC|15|39-12-10-04| ~~ee~~ **Approvals Certificates General Product Approval** Manufacturer DeclaraDeclaration of ConChina RoHS tion formity ~~CE~~ & **Maritime application** **last modified:** 5/5/2026 Subject to change without notice © Copyright Siemens 6EP31330TA100AY0 Page 4/4 5/18/2026
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →