Image not available
Illustrative purposes only
6EP1731-2BA00
Isolated DIN Rail Mount DC/DC Converter, ITE, 8:1, 9 W, 1 Output, 24 V, 375 mA
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Isolated DIN Rail Mount DC / DC Converters
- SVHC: To Be Advised
- Depth: 91mm
- Width: 22.5mm
- Height: 80mm
- Input Ratio: 8:1
- Product Range: SITOP POWER Series
- No. of Outputs: 1 Output
- Output Power Max: 9W
- Isolation Voltage: -
- Output Regulation: -
- Input Voltage DC Max: 264V
- Input Voltage DC Min: 30V
- Input Voltage DC Nom: -
- Output Current - Output 1: 375mA
- Output Current - Output 2: -
- Output Voltage - Output 1: 24V
- Output Voltage - Output 2: -
- Power Supply Applications: ITE
- DC / DC Converter Output Type: Fixed, Adjustable
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 72.21 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6EP1731-2BA00** **Data sheet** SITOP POWER/DC/DC/48-220V/24V/0.375A ********** spare part ********* SITOP power 0.375 A, DC/DC stabilized power supply input: 48-220 V DC output: 24 V DC/0.375 A |SITOP POWER/DC/DC/48-220V/24V/0.375A<br>********** spare part ********* SITOP power 0.375 A, DC/DC stabilized power supply<br>input: 48-220 V DC output: 24 V DC/0.375 A<br>**input**<br>type of thepower supplynetwork<br>DC voltage<br>supplyvoltage at AC<br>● initial value<br>30 V<br>● full-scale value<br>187 V<br>supplyvoltage at DC<br>48 ... 220 V<br>input voltage at DC<br>30 ... 264 V<br>wide range input<br>Yes<br>overvoltage overload capability<br>-<br>buffering time for rated value of the output current in the event of<br>power failure minimum<br>10 ms<br>operatingcondition of the mains buffering<br>at Vin = 220 V<br>input current<br>● at rated input voltage 48 V<br>0.3 A<br>● at rated input voltage 220 V<br>0.06 A<br>current limitation of inrush current at 25 °C maximum<br>35 A<br>duration of inrush current limitingat 25 °C<br>● typical<br>3 ms<br>I2t value maximum<br>1.2 A²·s<br>fuseprotection type<br>F 4 A/250 V(not accessible)<br>fuse protection type in the feeder<br>Recommended miniature circuit breaker: from 6 A characteristic C, suitable for<br>DC<br>**output**<br>voltage curve at output<br>Controlled, isolated DC voltage<br>output voltage at DC rated value<br>24 V<br>output voltage<br>● at output 1 at DC rated value<br>24 V<br>output voltage adjustable<br>No; -<br>relative overall tolerance of the voltage<br>3 %<br>relative controlprecision of the output voltage<br>● on slow fluctuation of input voltage<br>0.1 %<br>● on slow fluctuation of ohm loading<br>0.1 %<br>residual ripple<br>● maximum<br>150 mV<br>● typical<br>50 mV<br>voltagepeak<br>● maximum<br>240 mV<br>● typical<br>50 mV<br>display version for normal operation<br>Green LED for 24 V OK|SITOP POWER/DC/DC/48-220V/24V/0.375A<br>********** spare part ********* SITOP power 0.375 A, DC/DC stabilized power supply<br>input: 48-220 V DC output: 24 V DC/0.375 A|| |---|---|---| ||Controlled, isolated DC voltage|| ||24 V|| |||| ||24 V|| ||No; -|| ||3 %|| |||| ||0.1 %|| ||0.1 %|| |||| ||150 mV|| ||50 mV|| |||| ||240 mV|| ||50 mV|| ||Green LED for 24 V OK|| Subject to change without notice © Copyright Siemens 6EP17312BA00 Page 1/4 5/18/2026 ||behavior of the output voltage when switchingon|No overshoot of Vout(soft start)|| |---|---|---|---| ||response delaymaximum|2.5 s|| ||voltage increase time of the output voltage||| ||● typical|90 ms|| ||output current||| ||● rated value|0.375 A|| ||● rated range|0 ... 0.375 A; +60 ... +70 °C: Derating3%/K|| ||supplied activepower typical|9 W|| ||short-term overload current||| ||● at short-circuit duringoperation typical|2.7 A|| ||duration of overloadingcapabilityfor excess current||| ||● at short-circuit duringoperation|200 ms|| ||bridgingof equipment|No|| ||**efficiency**||| ||efficiencyinpercent|66 %|| ||power loss[W]||| ||● at rated output voltage for rated value of the output<br>current typical|4.6 W|| ||**closed-loop control**||| ||relative control precision of the output voltage with rapid<br>fluctuation of the input voltage by+/- 15% typical|0.3 %|| ||relative control precision of the output voltage load step of<br>resistive load 50/100/50 % typical|0.4 %|| ||settingtime||| ||● load step50 to 100% typical|2 ms|| ||● load step 100 to 50% typical|2 ms|| ||**protection and monitoring**||| ||design of the overvoltageprotection|< 60 V|| ||propertyof the output short-circuitproof|Yes|| ||design of short-circuitprotection|Electronic shutdown, automatic restart|| ||response value current limitation|0.41 ... 0.49 A|| ||enduringshort circuit current RMS value||| ||● maximum|0.9 A|| ||**safety**||| ||galvanic isolation between input and output|Yes|| ||galvanic isolation|Output voltage: SELV, ES1(IEC 62368-1), DVC As(IEC 61204-7)|| ||operatingresourceprotection class|Class I|| ||leakage current||| ||● maximum|3.5 mA|| ||protection class IP|IP20|| ||**EMC**||| ||standard||| ||● for emitted interference|EN 55022 Class B|| ||● for mains harmonics limitation|not applicable|| ||● for interference immunity|EN 61000-6-2|| ||**standards, specifications, approvals**||| ||certificate of suitability||| ||● CE marking|Yes|| ||● UL approval|Yes; cULus-Listed (UL 508, CSA C22.2 No. 142), File E143289; cURus-<br>Recognized(UL 60950, CSA C22.2 No. 60950), File E151273|| ||● EAC approval|Yes|| ||● NEC Class 2|No|| ||type of certification||| ||● CB-certificate|No|| ||MTBF at 40 °C|1 466 123 h|| ||**standards, specifications, approvals hazardous environments**||| ||certificate of suitability||| ||● IECEx|No|| ||● ATEX|No|| ||● ULhazloc approval|No|| Subject to change without notice © Copyright Siemens 6EP17312BA00 Page 2/4 5/18/2026 |● FM registration|No| |---|---| |**standards, specifications, approvals marine classification**|| |shipbuildingapproval|No| |Marine classification association|| |● American Bureau of ShippingEurope Ltd.(ABS)|No| |● French marine classification society (BV)|No| |● Det Norske Veritas(DNV)|No| |● Lloyds Register of Shipping (LRS)|No| |**ambient conditions**|| |ambient temperature|| |● duringoperation|-25 ... +70 °C; with natural convection| |● duringtransport|-40 ... +70 °C| |● duringstorage|-40 ... +70 °C| |environmental categoryaccordingto IEC 60721|Climate class 3K3, 5 ... 95% no condensation| |**connection method**|| |type of electrical connection|screw terminal| |● at input|L+1, M1, PE: 1 screw terminal each for 0.5 ... 2.5 mm² single-core/finely<br>stranded| |● at output|+: 1 screw terminal for 0.5 ... 2.5 mm²; -: 2 screw terminals for 0.5 ... 2.5 mm²| |● for auxiliarycontacts|-| |**mechanical data**|| |width × height × depth of the enclosure|22.5 × 80 × 91 mm| |installation width × mountingheight|22.5 mm × 180 mm| |required spacing|| |● top|50 mm| |● bottom|50 mm| |● left|0 mm| |● right|0 mm| |fasteningmethod|Snaps onto DIN rail EN 60715 35x7.5/15| |● DIN-rail mounting|Yes| |● S7 rail mounting|No| |● wall mounting|No| |housingcan be lined up|Yes| |net weight|0.14 kg| |**further information internet links**|| |internet link|| |● to website: IndustryMall|https://mall.industry.siemens.com| |● to webpage: selection aid TIA Selection Tool|https://www.siemens.com/tstcloud| |● to website: CAx-Download-Manager|https://siemens.com/cax| |● to website: IndustryOnline Support|https://support.industry.siemens.com| |**additional information**|| |other information|Specifications at rated input voltage and ambient temperature +25 °C (unless<br>otherwise specified)| |**security information**|| |security information|Siemens provides products and solutions with industrial cybersecurity functions<br>that support the secure operation of plants, systems, machines and networks.<br>In order to protect plants, systems, machines and networks against cyber<br>threats, it is necessary to implement - and continuously maintain - a holistic,<br>state-of-the-art industrial cybersecurity concept. Siemens’ products and<br>solutions constitute one element of such a concept. Customers are responsible<br>for preventing unauthorized access to their plants, systems, machines and<br>networks. Such systems, machines and components should only be connected<br>to an enterprise network or the internet if and to the extent such a connection is<br>necessary and only when appropriate security measures (e.g. firewalls and/or<br>network segmentation) are in place. For additional information on industrial<br>cybersecurity measures that may be implemented, please visit<br>www.siemens.com/cybersecurity-industry. Siemens’ products and solutions<br>undergo continuous development to make them more secure. Siemens strongly<br>recommends that product updates are applied as soon as they are available<br>and that the latest product versions are used. Use of product versions that are<br>no longer supported, and failure to apply the latest updates may increase<br>customer’s exposure to cyber threats. To stay informed about product updates,<br>subscribe to the Siemens Industrial Cybersecurity RSS Feed under<br>https://www.siemens.com/cert.(V4.7)| Subject to change without notice © Copyright Siemens 6EP17312BA00 Page 3/4 5/18/2026 ~~ee~~ **Classifications Version Classification** eClass 14 27-04-07-01 eClass 12 27-04-07-01 eClass 9.1 27-04-07-01 eClass 9 27-04-07-01 eClass 8 27-04-90-02 eClass 7.1 27-04-90-02 eClass 6 27-04-90-02 ETIM 10 EC002540 ETIM 9 EC002540 ETIM 8 EC002540 ETIM 7 EC002540 IDEA 4 4130 UNSPSC 15 39-12-10-04 ~~ee~~ **Approvals Certificates General Product Approval** Manufacturer DeclaraDeclaration of ConChina RoHS tion formity ~~—~~ G ~~E~~ ” **last modified:** 4/10/2026 Subject to change without notice © Copyright Siemens 6EP17312BA00 Page 4/4 5/18/2026
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →