Image not available
Illustrative purposes only
6EP1334-1LD00
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 300 W, 24 VDC, 12.5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: AC / DC Enclosed Power Supplies
- Product Range: SITOP PSU100D Series
- No. of Outputs: 1Outputs
- Output Power Max: 300W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 12.5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 124.41 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6EP1334-1LD00** **Data sheet** ||SITOP PSU100D/1AC/24VDC/12.5A<br>********** spare part ********* PSU100D 24 V/12.5 A stabilized power supply input:<br>100-240 V AC output: 24 V DC/12.5 A| |---|---| |**input**<br>~~|~~|| |type of thepower supplynetwork<br>~~|~~|1-phase AC<br>~~|~~| |supplyvoltage at AC|| |● minimum rated value|100 V| |● maximum rated value|240 V| |● initial value|85 V| |● full-scale value|264 V| |wide range input|Yes| |buffering time for rated value of the output current in the event of<br>power failure minimum|15 ms| |operatingcondition of the mains buffering|at Vin = 115/230 V| |line frequency|50/60 Hz| |line frequency|47 ... 63 Hz| |input current|| |● at rated input voltage 100 V|4 A| |● at rated input voltage 240 V|2 A| |current limitation of inrush current at 25 °C maximum|60 A| |I2t value maximum|1.1 A²·s| |fuseprotection type|internal| |fuse protection type in the feeder|Recommended miniature circuit breaker: from 10 A characteristic C or from 16<br>A characteristic B| |**output**<br>~~|~~|| |voltage curve at output<br>~~|~~|Controlled, isolated DC voltage<br>~~|~~| |output voltage at DC rated value|24 V| |output voltage|| |● at output 1 at DC rated value|24 V| |output voltage adjustable|Yes; viapotentiometer| |adjustable output voltage|22 ... 28 V| |relative overall tolerance of the voltage|2 %| |relative controlprecision of the output voltage|| |● on slow fluctuation of input voltage|0.5 %| |● on slow fluctuation of ohm loading|0.5 %| |residual ripple|| |● maximum|100 mV| |voltagepeak|| |● maximum|100 mV| |displayversion for normal operation|Green LED for 24 V OK| |type of signal at output|-| |behavior of the output voltage when switchingon|Overshoot of Vout < 2 %| |response delaymaximum|1 s| |voltage increase time of the output voltage|| |● maximum|30 ms| |output current|| |● rated value|12.5 A| |● rated range|0 ... 12.5 A; +50 ... +70 °C: Derating2.5%/K| |supplied activepower typical|300 W| |bridgingof equipment|Yes| |number of parallel-switched equipment resources for increasing<br>the power|2| Subject to change without notice © Copyright Siemens 6EP13341LD00 Page 1/4 5/19/2026 |**efficiency**|**efficiency**| |---|---| |efficiencyinpercent|86 %| |power loss[W]|| |● at rated output voltage for rated value of the output<br>current typical|48 W| |**closed-loop control**|| |relative control precision of the output voltage with rapid<br>fluctuation of the input voltage by+/- 15% typical|0.5 %| |relative control precision of the output voltage load step of<br>resistive load 50/100/50 % typical|5 %| |**protection and monitoring**|| |design of the overvoltageprotection|< 35 V| |propertyof the output short-circuitproof|Yes| |design of short-circuitprotection|Electronic shutdown, automatic restart| |● typical|15 A| |enduringshort circuit current RMS value|| |● typical|15 A| |**safety**|| |galvanic isolation between input and output|Yes| |galvanic isolation|Safetyextra low output voltage Vout accordingto EN 60950-1| |operatingresourceprotection class|Class I| |leakage current|| |● maximum|3.5 mA| |● typical|1 mA| |protection class IP|IP20| |**EMC**|| |standard|| |● for emitted interference|EN 55022 Class B| |● for mains harmonics limitation|EN 61000-3-2| |● for interference immunity|EN 61000-6-2| |**standards, specifications, approvals**|| |certificate of suitability|| |● CE marking|Yes| |● UL approval|Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus (UL<br>60950-1, CSA C22.2 No. 60950-1), File E151273| |● EAC approval|Yes| |● NEC Class 2|No| |type of certification|| |● CB-certificate|Yes| |**standards, specifications, approvals hazardous environments**|| |certificate of suitability|| |● IECEx|No| |● ATEX|No| |● ULhazloc approval|No| |● FM registration|No| |**standards, specifications, approvals marine classification**|| |shipbuildingapproval|No| |Marine classification association|| |● American Bureau of ShippingEurope Ltd.(ABS)|No| |● French marine classification society (BV)|No| |● Det Norske Veritas(DNV)|No| |● Lloyds Register of Shipping (LRS)|No| |**standards, specifications, approvals Environmental Product Declaration**|| |Environmental Product Declaration|Yes| |global warming potential[CO2 eq]|| |● total|1 517.8 kg| |● duringmanufacturing|16 kg| |● duringoperation|1 501.3 kg| |● after end of life|0.24 kg| Subject to change without notice © Copyright Siemens 6EP13341LD00 Page 2/4 5/19/2026 |**ambient conditions**|||| |---|---|---|---| |ambient temperature|||| |● duringoperation|-10 ... +70 °C; with forced convection(ventilator)||| |● duringtransport|-40 ... +85 °C||| |● duringstorage|-40 ... +85 °C||| |**connection method**|||| |type of electrical connection|screw terminal||| |● at input|L, N, PE: 1 screw terminal each for 0.5 ... 1.3 mm² single-core/finelystranded||| |● at output|+, -: 2 screw terminals each for 0.5 ... 1.3 mm²||| |● for auxiliarycontacts|-||| |**mechanical data**|||| |width × height × depth of the enclosure|105 × 199 × 41 mm||| |required spacing|||| |● top|20 mm||| |● bottom|0 mm||| |● left|20 mm||| |● right|20 mm||| |fasteningmethod|Wall mounting||| |● DIN-rail mounting|No||| |● S7 rail mounting|No||| |● wall mounting|Yes||| |net weight|0.81 kg||| |**further information internet links**|||| |internet link|||| |● to website: IndustryMall|https://mall.industry.siemens.com||| |● to webpage: selection aid TIA Selection Tool|https://www.siemens.com/tstcloud||| |● to website: CAx-Download-Manager|https://siemens.com/cax||| |● to website: IndustryOnline Support|https://support.industry.siemens.com||| |**additional information**|||| |other information|Specifications at rated input voltage and ambient temperature +25 °C (unless<br>otherwise specified)||| |**security information**|||| |security information|Siemens provides products and solutions with industrial cybersecurity functions<br>that support the secure operation of plants, systems, machines and networks.<br>In order to protect plants, systems, machines and networks against cyber<br>threats, it is necessary to implement - and continuously maintain - a holistic,<br>state-of-the-art industrial cybersecurity concept. Siemens’ products and<br>solutions constitute one element of such a concept. Customers are responsible<br>for preventing unauthorized access to their plants, systems, machines and<br>networks. Such systems, machines and components should only be connected<br>to an enterprise network or the internet if and to the extent such a connection is<br>necessary and only when appropriate security measures (e.g. firewalls and/or<br>network segmentation) are in place. For additional information on industrial<br>cybersecurity measures that may be implemented, please visit<br>www.siemens.com/cybersecurity-industry. Siemens’ products and solutions<br>undergo continuous development to make them more secure. Siemens strongly<br>recommends that product updates are applied as soon as they are available<br>and that the latest product versions are used. Use of product versions that are<br>no longer supported, and failure to apply the latest updates may increase<br>customer’s exposure to cyber threats. To stay informed about product updates,<br>subscribe to the Siemens Industrial Cybersecurity RSS Feed under<br>https://www.siemens.com/cert.(V4.7)||| |**Classifications**|||| |||**Version**|**Classification**| ||eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>ETIM|14<br>12<br>9.1<br>9<br>8<br>7.1<br>6<br>10|27-04-07-01<br>27-04-07-01<br>27-04-07-01<br>27-04-07-01<br>27-04-90-02<br>27-04-90-02<br>27-04-90-02<br>EC002540| |**ambient conditions**|||| |---|---|---|---| |ambient temperature|||| |● duringoperation|-10 ... +70 °C; with forced convection(ventilator)||| |● duringtransport|-40 ... +85 °C||| |● duringstorage|-40 ... +85 °C||| |**connection method**|||| |type of electrical connection|screw terminal||| |● at input|L, N, PE: 1 screw terminal each for 0.5 ... 1.3 mm² single-core/finelystranded||| |● at output|+, -: 2 screw terminals each for 0.5 ... 1.3 mm²||| |● for auxiliarycontacts|-||| |**mechanical data**|||| |width × height × depth of the enclosure|105 × 199 × 41 mm||| |required spacing|||| |● top|20 mm||| |● bottom|0 mm||| |● left|20 mm||| |● right|20 mm||| |fasteningmethod|Wall mounting||| |● DIN-rail mounting|No||| |● S7 rail mounting|No||| |● wall mounting|Yes||| |net weight|0.81 kg||| |**further information internet links**|||| |internet link|||| |● to website: IndustryMall|https://mall.industry.siemens.com||| |● to webpage: selection aid TIA Selection Tool|https://www.siemens.com/tstcloud||| |● to website: CAx-Download-Manager|https://siemens.com/cax||| |● to website: IndustryOnline Support|https://support.industry.siemens.com||| |**additional information**|||| |other information|Specifications at rated input voltage and ambient temperature +25 °C (unless<br>otherwise specified)||| |**security information**|||| |security information|Siemens provides products and solutions with industrial cybersecurity functions<br>that support the secure operation of plants, systems, machines and networks.<br>In order to protect plants, systems, machines and networks against cyber<br>threats, it is necessary to implement - and continuously maintain - a holistic,<br>state-of-the-art industrial cybersecurity concept. Siemens’ products and<br>solutions constitute one element of such a concept. Customers are responsible<br>for preventing unauthorized access to their plants, systems, machines and<br>networks. Such systems, machines and components should only be connected<br>to an enterprise network or the internet if and to the extent such a connection is<br>necessary and only when appropriate security measures (e.g. firewalls and/or<br>network segmentation) are in place. For additional information on industrial<br>cybersecurity measures that may be implemented, please visit<br>www.siemens.com/cybersecurity-industry. Siemens’ products and solutions<br>undergo continuous development to make them more secure. Siemens strongly<br>recommends that product updates are applied as soon as they are available<br>and that the latest product versions are used. Use of product versions that are<br>no longer supported, and failure to apply the latest updates may increase<br>customer’s exposure to cyber threats. To stay informed about product updates,<br>subscribe to the Siemens Industrial Cybersecurity RSS Feed under<br>https://www.siemens.com/cert.(V4.7)||| |**Classifications**|||| |||**Version**|**Classification**| ||eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>ETIM|14<br>12<br>9.1<br>9<br>8<br>7.1<br>6<br>10|27-04-07-01<br>27-04-07-01<br>27-04-07-01<br>27-04-07-01<br>27-04-90-02<br>27-04-90-02<br>27-04-90-02<br>EC002540| ||**Version**|**Classification**| |---|---|---| |eClass|14|27-04-07-01| |eClass|12|27-04-07-01| |eClass|9.1|27-04-07-01| |eClass|9|27-04-07-01| |eClass|8|27-04-90-02| |eClass|7.1|27-04-90-02| |eClass|6|27-04-90-02| |ETIM|10|EC002540| Subject to change without notice © Copyright Siemens 6EP13341LD00 Page 3/4 5/19/2026 ETIM 9 EC002540 ETIM 8 EC002540 ETIM 7 EC002540 IDEA 4 4130 UNSPSC 15 39-12-10-04 **Approvals Certificates** ~~a~~ Environmental Product Declaration ● global warming potential [CO2 eq] / during manufacturing 16 kg ● global warming potential [CO2 eq] / during operation 1501.3 kg ● global warming potential [CO2 eq] / after end of life 0.24 kg ● global warming potential [CO2 eq] / total 1517.8 kg **Environment General Product Approval** Manufacturer DeclaraDeclaration of ConChina RoHS tion formity ~~S~~ € **last modified:** 3/26/2026 Subject to change without notice © Copyright Siemens 6EP13341LD00 Page 4/4 5/19/2026
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →