6EP1333-7CA00
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 133 W, 24 VDC, 5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: AC / DC Enclosed Power Supplies
- Product Range: SITOP PSU100P Series
- No. of Outputs: 1Outputs
- Output Power Max: 133W
- Current, Output 4: -
- Input Voltage VAC: 170V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 294.06 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6EP1333-7CA00** **Data sheet** SITOP PSU100P/1AC/24VDC/5A/IP67 SITOP PSU100P IP67 Stabilized power supply input: 120/230 V AC, output: 24 V DC/5 A ## **General information** |2)<br>Oo<br>==<br>UW)<br>oO<br>5=<br>YW)|SITOP PSU100P/1AC/24VDC/5A/IP67<br>SITOP PSU100P IP67 Stabilized power supply input: 120/230 V AC, output: 24 V<br>DC/5 A| |---|---| |**General information**|| |Technical Product Detail Page|https://i.siemens.com/1P6EP1333-7CA00| |**input**|| |type of thepower supplynetwork|1-phase AC| |supplyvoltage at AC|Automatic range selection| |supplyvoltage|120 V/230 V| |input voltage 1 at AC|85 ... 132 V| |input voltage 2 at AC|170 ... 264 V| |wide range input|No| |overvoltage overload capability|Implemented internallywith varistor| |buffering time for rated value of the output current in the event of<br>power failure minimum|40 ms| |operatingcondition of the mains buffering|at Vin = 120/230 V| |line frequency|50/60 Hz| |line frequency|47 ... 63 Hz| |input current|| |● at rated input voltage 120 V|2.25 A| |● at rated input voltage 230 V|1.24 A| |current limitation of inrush current at 25 °C maximum|15 A| |I2t value maximum|0.6 A²·s| |fuseprotection type|T 3.15 A| |fuse protection type in the feeder|Recommended miniature circuit breaker: from 6 A characteristic C/B| |**output**|| |voltage curve at output|Controlled, isolated DC voltage| |output voltage at DC rated value|24 V| |output voltage|| |● at output 1 at DC rated value|24 V| |output voltage adjustable|No| |relative overall tolerance of the voltage|3 %| |relative controlprecision of the output voltage|| |● on slow fluctuation of input voltage|0.1 %| |● on slow fluctuation of ohm loading|0.2 %| |residual ripple|| |● maximum|50 mV| |voltagepeak|| |● maximum|100 mV| |displayversion for normal operation|Green LED: 24 V OK; red LED flashing: "overload/short-circuit"| |type of signal at output|Relaycontact(NO contact, rating30 V AC/ 0.5 A; 30 V DC/1 A)for 24 V OK| |behavior of the output voltage when switching on|Overshoot of Vout < 3 %| 6EP13337CA00 Page 1/4 Subject to change without notice © Copyright Siemens 6/4/2026 |response delaymaximum|1.5 s| |---|---| |voltage increase time of the output voltage|| |● typical|22 ms| |● maximum|100 ms| |output current|| |● rated value|5 A| |● rated range|0 ... 5 A| |supplied activepower typical|133 W| |short-term overload current|| |● on short-circuitingduringthe start-uptypical|20 A| |● at short-circuit duringoperation typical|20 A| |duration of overloadingcapabilityfor excess current|| |● on short-circuitingduringthe start-up|50 ms| |● at short-circuit duringoperation|50 ms| |bridgingof equipment|Yes; Symmetric wiringrequired| |number of parallel-switched equipment resources for increasing<br>the power|2| |**efficiency**|| |efficiencyinpercent|90 %| |power loss[W]|| |● at rated output voltage for rated value of the output<br>current typical|12.9 W| |**closed-loop control**|| |relative control precision of the output voltage with rapid<br>fluctuation of the input voltage by+/- 15% typical|0.2 %| |relative control precision of the output voltage load step of<br>resistive load 50/100/50 % typical|1 %| |settingtime|| |● maximum|2 ms| |**protection and monitoring**|| |design of the overvoltageprotection|< 29 V| |propertyof the output short-circuitproof|Yes| |design of short-circuitprotection|Electronic shutdown, automatic restart| |● typical|5.5 A| |enduringshort circuit current RMS value|| |● maximum|6 A| |● typical|5 A| |displayversion for overload and short circuit|Red LED flashingfor "overload/short-circuit"| |**safety**|| |galvanic isolation between input and output|Yes| |galvanic isolation|Output voltage: SELV, ES1(IEC 62368-1), DVC As(IEC 61204-7)| |operatingresourceprotection class|Class I| |leakage current|| |● maximum|3.5 mA| |● typical|1 mA| |protection class IP|IP67| |**EMC**|| |standard|| |● for emitted interference|EN 55022 Class B| |● for mains harmonics limitation|EN 61000-3-2| |● for interference immunity|EN 61000-6-2| |**standards, specifications, approvals**|| |certificate of suitability|| |● CE marking|Yes| |● UL approval|Yes; cULus-Listed(UL 508, CSA C22.2 No. 107.1)| |● EAC approval|Yes| |● NEC Class 2|No| |type of certification|| |● CB-certificate|No| 6EP13337CA00 Page 2/4 Subject to change without notice © Copyright Siemens 6/4/2026 ||MTBF at 40 °C|1 500 000 h|| |---|---|---|---| ||**standards, specifications, approvals hazardous environments**||| ||certificate of suitability||| ||● IECEx|No|| ||● ATEX|No|| ||● ULhazloc approval|No|| ||● FM registration|No|| ||**standards, specifications, approvals marine classification**||| ||shipbuildingapproval|No|| ||Marine classification association||| ||● American Bureau of ShippingEurope Ltd.(ABS)|No|| ||● French marine classification society (BV)|No|| ||● Det Norske Veritas(DNV)|No|| ||● Lloyds Register of Shipping (LRS)|No|| ||**ambient conditions**||| ||ambient temperature||| ||● duringoperation|-25 ... +60 °C; with natural convection|| ||● duringtransport|-40 ... +85 °C|| ||● duringstorage|-40 ... +85 °C|| ||environmental categoryaccordingto IEC 60721|3K6 without direct sunlight|| ||**connection method**||| ||type of electrical connection|screw terminal|| ||● at input|L1, N, PE: Plug connector 7/8" (counterpart see "Operating Instructions<br>(compact)")|| ||● at output|+, -: Plugconnector 7/8"(counterpart see "OperatingInstructions(compact)")|| ||● for auxiliarycontacts|Alarm signals: M12plug-in connector 4-pin|| ||removable terminal at input|Yes|| ||removable terminal at output|Yes|| ||**mechanical data**||| ||width × height × depth of the enclosure|120 × 181 × 60.5 mm|| ||installation width × mountingheight|120 mm × 170 mm|| ||required spacing||| ||● top|50 mm|| ||● bottom|0 mm|| ||● left|0 mm|| ||● right|0 mm|| ||fasteningmethod|Wall mounting|| ||● DIN-rail mounting|No|| ||● S7 rail mounting|No|| ||● wall mounting|Yes|| ||housingcan be lined up|Yes|| ||net weight|1.1 kg|| ||**further information internet links**||| ||internet link||| ||● to website: IndustryMall|https://mall.industry.siemens.com|| ||● to webpage: selection aid TIA Selection Tool|https://www.siemens.com/tstcloud|| ||● to website: CAx-Download-Manager|https://siemens.com/cax|| ||● to website: IndustryOnline Support|https://support.industry.siemens.com|| ||**additional information**||| ||other information|Specifications at rated input voltage and ambient temperature +25 °C (unless<br>otherwise specified)|| ||**security information**||| ||security information|Siemens provides products and solutions with industrial cybersecurity functions<br>that support the secure operation of plants, systems, machines and networks.<br>In order to protect plants, systems, machines and networks against cyber<br>threats, it is necessary to implement - and continuously maintain - a holistic,<br>state-of-the-art industrial cybersecurity concept. Siemens’ products and<br>solutions constitute one element of such a concept. Customers are responsible<br>for preventing unauthorized access to their plants, systems, machines and<br>networks. Such systems, machines and components should only be connected<br>to an enterprise network or the internet if and to the extent such a connection is<br>necessary and only when appropriate security measures (e.g. firewalls and/or|| 6EP13337CA00 Page 3/4 Subject to change without notice © Copyright Siemens 6/4/2026 network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7) ## **Classifications** ||**Version**|**Classification**| |---|---|---| |eClass|14|27-04-07-01| |eClass|12|27-04-07-01| |eClass|9.1|27-04-07-01| |eClass|9|27-04-07-01| |eClass|8|27-04-90-02| |eClass|7.1|27-04-90-02| |eClass|6|27-04-90-02| |ETIM|10|EC002540| |ETIM|9|EC002540| |ETIM|8|EC002540| |ETIM|7|EC002540| |IDEA|4|4130| |UNSPSC|15|39-12-10-04| ~~ee~~ **Approvals Certificates** ~~eee~~ **General Product Approval** Manufacturer DeclaraDeclaration of ConChina RoHS tion formity ~~—~~ EE **last modified:** 5/5/2026 5/5/2026 6EP13337CA00 Page 4/4 Subject to change without notice © Copyright Siemens 6/4/2026
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →