Image not available
Illustrative purposes only
6EP1333-4BA00
Regulated Power Supply, 1 Phase, 62 A, 230 VAC, 8 A, 24 VDC, SIMATIC S7-1500 Advanced Controllers
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Controller Accessories
- SVHC: To Be Advised
- Product Range: SIMATIC PM Series
- Current Rating: 62A
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 174.0 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6EP1333-4BA00** **Data sheet** SIMATIC PM 1507/1AC/24VDC/8A SIMATIC PM 1507 24 V/8 A stabilized power supply for SIMATIC S7-1500 input: 120/230 V AC output: 24 V DC/8 A without Ex approval ||SIMATIC PM 1507/1AC/24VDC/8A<br>SIMATIC PM 1507 24 V/8 A stabilized power supply for SIMATIC S7-1500 input:<br>120/230 V AC output: 24 V DC/8 A without Ex approval| |---|---| |**General information**<br>~~ee~~|| |Technical Product Detail Page<br>~~ee~~<br>~~|~~|https://i.siemens.com/1P6EP1333-4BA00<br>~~ee~~<br>~~|~~| |**input**<br>~~|~~|| |type of thepower supplynetwork<br>~~|~~|1-phase AC<br>~~|~~| |supplyvoltage at AC|Automatic range selection| |supplyvoltage|120 V/230 V| |input voltage 1 at AC|85 ... 132 V| |input voltage 2 at AC|170 ... 264 V| |wide range input|No| |overvoltage overload capability|2.3 × Vin rated, 1.3 ms| |buffering time for rated value of the output current in the event of<br>power failure minimum|20 ms| |operatingcondition of the mains buffering|at Vin = 93/187 V| |line frequency|50/60 Hz| |line frequency|45 ... 65 Hz| |input current|| |● at rated input voltage 120 V|3.7 A| |● at rated input voltage 230 V|1.7 A| |current limitation of inrush current at 25 °C maximum|62 A| |duration of inrush current limitingat 25 °C|| |● maximum|3 ms| |I2t value maximum|12 A²·s| |fuseprotection type|T 6.3 A/250 V(not accessible)| |fuse protection type in the feeder|Recommended miniature circuit breaker: 16 A characteristic B or 10 A<br>characteristic C| |**output**<br>~~ee~~|| |voltage curve at output<br>~~ee~~|Controlled, isolated DC voltage<br>~~ee~~| |output voltage at DC rated value|24 V| |output voltage|| |● at output 1 at DC rated value|24 V| |output voltage adjustable|No| |relative overall tolerance of the voltage|1 %| |relative controlprecision of the output voltage|| |● on slow fluctuation of input voltage|0.1 %| |● on slow fluctuation of ohm loading|0.1 %| |residual ripple|| |● maximum|50 mV| |voltagepeak|| |● maximum|150 mV| Subject to change without notice © Copyright Siemens 6EP13334BA00 Page 1/5 5/17/2026 ||displayversion for normal operation|LEDgreen for 24 V OK; LED red for error; LEDyellow for stand-by|| |---|---|---|---| ||behavior of the output voltage when switchingon|No overshoot of Vout(soft start)|| ||response delaymaximum|1.5 s|| ||voltage increase time of the output voltage||| ||● typical|10 ms|| ||output current||| ||● rated value|8 A|| ||● rated range|0 ... 8 A|| ||supplied activepower typical|192 W|| ||short-term overload current||| ||● on short-circuitingduringthe start-uptypical|35 A|| ||● at short-circuit duringoperation typical|35 A|| ||duration of overloadingcapabilityfor excess current||| ||● on short-circuitingduringthe start-up|70 ms|| ||● at short-circuit duringoperation|70 ms|| ||bridgingof equipment|Yes|| ||number of parallel-switched equipment resources for increasing<br>the power|2|| ||**efficiency**||| ||efficiencyinpercent|90 %|| ||power loss[W]||| ||● at rated output voltage for rated value of the output<br>current typical|21 W|| ||**closed-loop control**||| ||relative control precision of the output voltage with rapid<br>fluctuation of the input voltage by+/- 15% typical|0.1 %|| ||relative control precision of the output voltage load step of<br>resistive load 50/100/50 % typical|2 %|| ||relative control precision of the output voltage at load step of<br>resistive load 10/90/10 % typical|3 %|| ||settingtime||| ||● load step10 to 90% typical|5 ms|| ||● load step90 to 10% typical|5 ms|| ||● maximum|5 ms|| ||**protection and monitoring**||| ||design of the overvoltageprotection|Additional control loop, limitation(closed loopcontrol)at < 28.8 V|| ||propertyof the output short-circuitproof|Yes|| ||design of short-circuitprotection|Electronic shutdown, automatic restart|| ||response value current limitation|8.4 ... 9.6 A|| ||● typical|9 A|| ||**safety**||| ||galvanic isolation between input and output|Yes|| ||galvanic isolation|Output voltage: SELV, ES1(IEC 62368-1), DVC As(IEC 61204-7)|| ||operatingresourceprotection class|Class I|| ||leakage current||| ||● maximum|3.5 mA|| ||● typical|1.3 mA|| ||protection class IP|IP20|| ||**EMC**||| ||standard||| ||● for emitted interference|EN 55022 Class B|| ||● for mains harmonics limitation|EN 61000-3-2|| ||● for interference immunity|EN 61000-6-2|| ||**standards, specifications, approvals**||| ||certificate of suitability||| ||● CE marking|Yes|| ||● UL approval|Yes; cULus-Listed(UL 508, CSA C22.2 No. 142), File E143289|| ||● UKCA marking|Yes|| ||● EAC approval|Yes|| ||● Regulatory Compliance Mark (RCM)|Yes|| Subject to change without notice © Copyright Siemens 6EP13334BA00 Page 2/5 5/17/2026 |● NEC Class 2|No| |---|---| |type of certification|| |● BIS|Yes; R-41183539| |● CB-certificate|Yes| |MTBF at 40 °C|1 362 918 h| |**standards, specifications, approvals hazardous environments**|| |certificate of suitability|| |● IECEx|No| |● ATEX|No| |● ULhazloc approval|No| |● UKEX|No| |● CCC for hazardous zone accordingto GB standard|No| |● FM registration|No| |**standards, specifications, approvals marine classification**|| |shipbuildingapproval|Yes| |Marine classification association|| |● American Bureau of ShippingEurope Ltd.(ABS)|Yes| |● French marine classification society (BV)|Yes| |● Det Norske Veritas(DNV)|Yes| |● Lloyds Register of Shipping (LRS)|No| |**standards, specifications, approvals Environmental Product Declaration**|| |Environmental Product Declaration|Yes| |global warming potential[CO2 eq]|| |● total|589.1 kg| |● duringmanufacturing|14 kg| |● duringoperation|574.3 kg| |● after end of life|0.51 kg| |**ambient conditions**|| |ambient temperature|| |● duringoperation|0 ... 60 °C; with natural convection| |● in horizontal mounting position duringoperation|0 ... 60 °C| |● in vertical mounting position duringoperation|0 ... 40 °C| |● duringtransport|-40 ... +85 °C| |● duringstorage|-40 ... +85 °C| |environmental categoryaccordingto IEC 60721|Climate class 3K3, 5 ... 95% no condensation| |**connection method**|| |type of electrical connection|Screw-/springclampconnection| |● at input|L, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm²| |● at output|L+, M: 2 spring-loaded terminals each for 0.5 to 2.5 mm²| |removable terminal at input|Yes| |removable terminal at output|Yes| |**mechanical data**|| |width × height × depth of the enclosure|75 × 147 × 129 mm| |installation width × mountingheight|75 mm × 205 mm| |required spacing|| |● top|40 mm| |● bottom|40 mm| |● left|0 mm| |● right|0 mm| |fasteningmethod|Can be mounted onto S7-1500 rail| |● DIN-rail mounting|No| |● S7 rail mounting|Yes| |● wall mounting|No| |housingcan be lined up|Yes| |net weight|0.74 kg| |**further information internet links**|| |internet link|| |● to website: Industry Mall|https://mall.industry.siemens.com| Subject to change without notice © Copyright Siemens 6EP13334BA00 Page 3/5 5/17/2026 ||● to webpage: selection aid TIA Selection Tool|https://www.siemens.com/tstcloud| |---|---|---| ||● to webpage:power supplies|https://siemens.com/sitop| ||● to website: CAx-Download-Manager|https://siemens.com/cax| ||● to website: IndustryOnline Support|https://support.industry.siemens.com| ||identification link|Yes; acc. to IEC 61406-1:2022| |**additional information**<br>~~rr~~||| ||other information|Specifications at rated input voltage and ambient temperature +25 °C (unless| |||otherwise specified)| |**security information**<br>security information<br>~~a~~||Siemens provides products and solutions with industrial cybersecurity functions| |||that support the secure operation of plants, systems, machines and networks.| |||In order to protect plants, systems, machines and networks against cyber| |||threats, it is necessary to implement - and continuously maintain - a holistic,| |||state-of-the-art industrial cybersecurity concept. Siemens’ products and| |||solutions constitute one element of such a concept. Customers are responsible| |||for preventing unauthorized access to their plants, systems, machines and| |||networks. Such systems, machines and components should only be connected| |||to an enterprise network or the internet if and to the extent such a connection is| |||necessary and only when appropriate security measures (e.g. firewalls and/or| |||network segmentation) are in place. For additional information on industrial| |||cybersecurity measures that may be implemented, please visit| |||www.siemens.com/cybersecurity-industry. Siemens’ products and solutions| |||undergo continuous development to make them more secure. Siemens strongly| |||recommends that product updates are applied as soon as they are available| |||and that the latest product versions are used. Use of product versions that are| |||no longer supported, and failure to apply the latest updates may increase| |||customer’s exposure to cyber threats. To stay informed about product updates,| |||subscribe to the Siemens Industrial Cybersecurity RSS Feed under| |||https://www.siemens.com/cert.(V4.7)| ## **Classifications** ||**Version**|**Classification**| |---|---|---| |eClass|14|27-04-07-01| |eClass|12|27-04-07-01| |eClass|9.1|27-04-07-01| |eClass|9|27-04-07-01| |eClass|8|27-04-90-02| |eClass|7.1|27-04-90-02| |eClass|6|27-04-90-02| |ETIM|10|EC002540| |ETIM|9|EC002540| |ETIM|8|EC002540| |ETIM|7|EC002540| |IDEA|4|4130| |UNSPSC|15|39-12-10-04| **Approvals Certificates** ~~EE~~ Environmental Product Declaration ● global warming potential [CO2 eq] / during manufacturing 14 kg ● global warming potential [CO2 eq] / during operation 574.3 kg ● global warming potential [CO2 eq] / after end of life 0.51 kg ● global warming potential [CO2 eq] / total 589.1 kg **Environment General Product Approval** Manufacturer Declaration ~~———~~ **General Product Approval** **For use in hazardous locations** Subject to change without notice © Copyright Siemens 6EP13334BA00 Page 4/5 5/17/2026 **==> picture [412 x 260] intentionally omitted <==** **----- Start of picture text -----**<br> China RoHS en () Miscellaneous BIS CRS Miscellaneous<br>UL<br>For use in hazardous locations Maritime application<br>® — FM CCC-Ex @® ®<br>ATEX UL<br>Maritime application<br>LES<br>last modified: 5/5/2026 G<br>**----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 6EP13334BA00 Page 5/5 5/17/2026
Updated at April 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →