6EP1332-1LD10
AC/DC Enclosed Power Supply (PSU), ITE, 1 Outputs, 100 W, 24 VDC, 4.1 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: AC / DC Enclosed Power Supplies
- Product Range: SITOP PSU100D Series
- No. of Outputs: 1Outputs
- Output Power Max: 100W
- Current, Output 4: -
- Input Voltage VAC: 85V AC to 264V AC
- Power Supply Output Type: Adjustable, Fixed
- Output Current - Output 1: 4.1A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 69.6 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6EP1332-1LD10** **Data sheet** |SITOP PSU100D/1AC/24VDC/4.1A<br>********** spare part ********* PSU100D 24 V/4.1 A stabilized power supply input:<br>100-240 V AC output: 24 V DC/4.1 A<br>**input**<br>type of thepower supplynetwork<br>1-phase AC<br>supplyvoltage at AC<br>● minimum rated value<br>100 V<br>● maximum rated value<br>240 V<br>● initial value<br>85 V<br>● full-scale value<br>264 V<br>wide range input<br>Yes<br>buffering time for rated value of the output current in the event of<br>power failure minimum<br>15 ms<br>operatingcondition of the mains buffering<br>at Vin = 115/230 V<br>line frequency<br>50/60 Hz<br>line frequency<br>47 ... 63 Hz<br>input current<br>● at rated input voltage 100 V<br>2 A<br>● at rated input voltage 240 V<br>1.1 A<br>current limitation of inrush current at 25 °C maximum<br>75 A<br>I2t value maximum<br>4 A²·s<br>fuseprotection type<br>internal<br>fuse protection type in the feeder<br>Recommended miniature circuit breaker: from 10 A characteristic C or from 16<br>A characteristic B<br>**output**<br>voltage curve at output<br>Controlled, isolated DC voltage<br>output voltage at DC rated value<br>24 V<br>output voltage<br>● at output 1 at DC rated value<br>24 V<br>output voltage adjustable<br>Yes; viapotentiometer<br>adjustable output voltage<br>22 ... 28 V<br>relative overall tolerance of the voltage<br>2 %<br>relative controlprecision of the output voltage<br>● on slow fluctuation of input voltage<br>0.5 %<br>● on slow fluctuation of ohm loading<br>1 %<br>residual ripple<br>● maximum<br>100 mV<br>voltagepeak<br>● maximum<br>100 mV<br>displayversion for normal operation<br>Green LED for 24 V OK<br>behavior of the output voltage when switchingon<br>Overshoot of Vout < 2 %<br>response delaymaximum<br>1 s<br>voltage increase time of the output voltage<br>● maximum<br>30 ms<br>output current<br>● rated value<br>4.1 A<br>● rated range<br>0 ... 4.1 A; +50 ... +70 °C: Derating2.5%/K<br>supplied activepower typical<br>100 W<br>bridgingof equipment<br>Yes<br>number of parallel-switched equipment resources for increasing<br>the power<br>2<br>**efficiency**<br>~~|~~<br>~~|~~<br>~~ed~~|SITOP PSU100D/1AC/24VDC/4.1A<br>********** spare part ********* PSU100D 24 V/4.1 A stabilized power supply input:<br>100-240 V AC output: 24 V DC/4.1 A|| |---|---|---| Subject to change without notice © Copyright Siemens 6EP13321LD10 Page 1/4 5/18/2026 ||efficiencyinpercent|86 %|| |---|---|---|---| ||power loss[W]||| ||● at rated output voltage for rated value of the output<br>current typical|16 W|| ||**closed-loop control**||| ||relative control precision of the output voltage with rapid<br>fluctuation of the input voltage by+/- 15% typical|0.5 %|| ||relative control precision of the output voltage load step of<br>resistive load 50/100/50 % typical|5 %|| ||**protection and monitoring**||| ||design of the overvoltageprotection|< 35 V|| ||propertyof the output short-circuitproof|Yes|| ||design of short-circuitprotection|Electronic shutdown, automatic restart|| ||● typical|4.9 A|| ||enduringshort circuit current RMS value||| ||● typical|10 A|| ||**safety**||| ||galvanic isolation between input and output|Yes|| ||galvanic isolation|Safetyextra low output voltage Vout accordingto EN 60950-1|| ||operatingresourceprotection class|Class I|| ||leakage current||| ||● maximum|3.5 mA|| ||● typical|1 mA|| ||protection class IP|IP20|| ||**EMC**||| ||standard||| ||● for emitted interference|EN 55022 Class B|| ||● for mains harmonics limitation|EN 61000-3-2|| ||● for interference immunity|EN 61000-6-2|| ||**standards, specifications, approvals**||| ||certificate of suitability||| ||● CE marking|Yes|| ||● UL approval|Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus (UL<br>60950-1, CSA C22.2 No. 60950-1), File E151273|| ||● EAC approval|Yes|| ||● NEC Class 2|No|| ||type of certification||| ||● CB-certificate|Yes|| ||**standards, specifications, approvals hazardous environments**||| ||certificate of suitability||| ||● IECEx|No|| ||● ATEX|No|| ||● ULhazloc approval|No|| ||● FM registration|No|| ||**standards, specifications, approvals marine classification**||| ||shipbuildingapproval|No|| ||Marine classification association||| ||● American Bureau of ShippingEurope Ltd.(ABS)|No|| ||● French marine classification society (BV)|No|| ||● Det Norske Veritas(DNV)|No|| ||● Lloyds Register of Shipping (LRS)|No|| ||**standards, specifications, approvals Environmental Product Declaration**||| ||Environmental Product Declaration|Yes|| ||global warming potential[CO2 eq]||| ||● total|508.8 kg|| ||● duringmanufacturing|8.1 kg|| ||● duringoperation|500.3 kg|| ||● after end of life|0.12 kg|| ||**ambient conditions**||| ||ambient temperature||| Subject to change without notice © Copyright Siemens 6EP13321LD10 Page 2/4 5/18/2026 |● duringoperation|-10 ... +70 °C; with natural convection|-10 ... +70 °C; with natural convection|-10 ... +70 °C; with natural convection| |---|---|---|---| |● duringtransport|-40 ... +85 °C||| |● duringstorage|-40 ... +85 °C||| |**connection method**|||| |type of electrical connection|screw terminal||| |● at input|L, N, PE: 1 screw terminal each for 0.3 ... 1.3 mm² single-core/finelystranded||| |● at output|+, -: 2 screw terminals each for 0.3 ... 1.3 mm²||| |● for auxiliarycontacts|-||| |**mechanical data**|||| |width × height × depth of the enclosure|97 × 158 × 38 mm||| |required spacing|||| |● top|20 mm||| |● bottom|0 mm||| |● left|20 mm||| |● right|20 mm||| |fasteningmethod|Wall mounting||| |● DIN-rail mounting|No||| |● S7 rail mounting|No||| |● wall mounting|Yes||| |net weight|0.5 kg||| |**further information internet links**|||| |internet link|||| |● to website: IndustryMall|https://mall.industry.siemens.com||| |● to webpage: selection aid TIA Selection Tool|https://www.siemens.com/tstcloud||| |● to website: CAx-Download-Manager|https://siemens.com/cax||| |● to website: IndustryOnline Support|https://support.industry.siemens.com||| |**additional information**|||| |other information|Specifications at rated input voltage and ambient temperature +25 °C (unless<br>otherwise specified)||| |**security information**|||| |security information|Siemens provides products and solutions with industrial cybersecurity functions<br>that support the secure operation of plants, systems, machines and networks.<br>In order to protect plants, systems, machines and networks against cyber<br>threats, it is necessary to implement - and continuously maintain - a holistic,<br>state-of-the-art industrial cybersecurity concept. Siemens’ products and<br>solutions constitute one element of such a concept. Customers are responsible<br>for preventing unauthorized access to their plants, systems, machines and<br>networks. Such systems, machines and components should only be connected<br>to an enterprise network or the internet if and to the extent such a connection is<br>necessary and only when appropriate security measures (e.g. firewalls and/or<br>network segmentation) are in place. For additional information on industrial<br>cybersecurity measures that may be implemented, please visit<br>www.siemens.com/cybersecurity-industry. Siemens’ products and solutions<br>undergo continuous development to make them more secure. Siemens strongly<br>recommends that product updates are applied as soon as they are available<br>and that the latest product versions are used. Use of product versions that are<br>no longer supported, and failure to apply the latest updates may increase<br>customer’s exposure to cyber threats. To stay informed about product updates,<br>subscribe to the Siemens Industrial Cybersecurity RSS Feed under<br>https://www.siemens.com/cert.(V4.7)||| |**Classifications**|||| |||**Version**|**Classification**| ||eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>ETIM<br>ETIM<br>ETIM|14<br>12<br>9.1<br>9<br>8<br>7.1<br>6<br>10<br>9<br>8|27-04-07-01<br>27-04-07-01<br>27-04-07-01<br>27-04-07-01<br>27-04-90-02<br>27-04-90-02<br>27-04-90-02<br>EC002540<br>EC002540<br>EC002540| |● duringoperation|-10 ... +70 °C; with natural convection|-10 ... +70 °C; with natural convection|-10 ... +70 °C; with natural convection| |---|---|---|---| |● duringtransport|-40 ... +85 °C||| |● duringstorage|-40 ... +85 °C||| |**connection method**|||| |type of electrical connection|screw terminal||| |● at input|L, N, PE: 1 screw terminal each for 0.3 ... 1.3 mm² single-core/finelystranded||| |● at output|+, -: 2 screw terminals each for 0.3 ... 1.3 mm²||| |● for auxiliarycontacts|-||| |**mechanical data**|||| |width × height × depth of the enclosure|97 × 158 × 38 mm||| |required spacing|||| |● top|20 mm||| |● bottom|0 mm||| |● left|20 mm||| |● right|20 mm||| |fasteningmethod|Wall mounting||| |● DIN-rail mounting|No||| |● S7 rail mounting|No||| |● wall mounting|Yes||| |net weight|0.5 kg||| |**further information internet links**|||| |internet link|||| |● to website: IndustryMall|https://mall.industry.siemens.com||| |● to webpage: selection aid TIA Selection Tool|https://www.siemens.com/tstcloud||| |● to website: CAx-Download-Manager|https://siemens.com/cax||| |● to website: IndustryOnline Support|https://support.industry.siemens.com||| |**additional information**|||| |other information|Specifications at rated input voltage and ambient temperature +25 °C (unless<br>otherwise specified)||| |**security information**|||| |security information|Siemens provides products and solutions with industrial cybersecurity functions<br>that support the secure operation of plants, systems, machines and networks.<br>In order to protect plants, systems, machines and networks against cyber<br>threats, it is necessary to implement - and continuously maintain - a holistic,<br>state-of-the-art industrial cybersecurity concept. Siemens’ products and<br>solutions constitute one element of such a concept. Customers are responsible<br>for preventing unauthorized access to their plants, systems, machines and<br>networks. Such systems, machines and components should only be connected<br>to an enterprise network or the internet if and to the extent such a connection is<br>necessary and only when appropriate security measures (e.g. firewalls and/or<br>network segmentation) are in place. For additional information on industrial<br>cybersecurity measures that may be implemented, please visit<br>www.siemens.com/cybersecurity-industry. Siemens’ products and solutions<br>undergo continuous development to make them more secure. Siemens strongly<br>recommends that product updates are applied as soon as they are available<br>and that the latest product versions are used. Use of product versions that are<br>no longer supported, and failure to apply the latest updates may increase<br>customer’s exposure to cyber threats. To stay informed about product updates,<br>subscribe to the Siemens Industrial Cybersecurity RSS Feed under<br>https://www.siemens.com/cert.(V4.7)||| |**Classifications**|||| |||**Version**|**Classification**| ||eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>ETIM<br>ETIM<br>ETIM|14<br>12<br>9.1<br>9<br>8<br>7.1<br>6<br>10<br>9<br>8|27-04-07-01<br>27-04-07-01<br>27-04-07-01<br>27-04-07-01<br>27-04-90-02<br>27-04-90-02<br>27-04-90-02<br>EC002540<br>EC002540<br>EC002540| ||**Version**|**Classification**| |---|---|---| |eClass|14|27-04-07-01| |eClass|12|27-04-07-01| |eClass|9.1|27-04-07-01| |eClass|9|27-04-07-01| |eClass|8|27-04-90-02| |eClass|7.1|27-04-90-02| |eClass|6|27-04-90-02| |ETIM|10|EC002540| |ETIM|9|EC002540| |ETIM|8|EC002540| Subject to change without notice © Copyright Siemens 6EP13321LD10 Page 3/4 5/18/2026 ETIM 7 EC002540 IDEA 4 4130 UNSPSC 15 39-12-10-04 **Approvals Certificates** Environmental Product Declaration ~~tt~~ ● global warming potential [CO2 eq] / during manufacturing 8.1 kg ~~<<~~ ● global warming potential [CO2 eq] / during operation 500.3 kg ● global warming potential [CO2 eq] / after end of life 0.12 kg ● global warming potential [CO2 eq] / total 508.8 kg **Environment General Product Approval** ee Manufacturer DeclaraDeclaration of ConChina RoHS tion formity m € ~~—~~ @ ~~55~~ **General Product Approval** **last modified:** 5/5/2026 Subject to change without notice © Copyright Siemens 6EP13321LD10 Page 4/4 5/18/2026
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →