Image not available
Illustrative purposes only
6DL1132-6HD50-0PK0
Signal Relay, 5 A, 120 VDC to 230 VAC
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Signal Relays
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 635.39 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6DL1132-6HD50-0PK0** **Data sheet** SIMATIC ET 200SP HA, Signal relay module changeover contact, RQ 4x120VDC230VAC/5A CO HA suitable for terminal block K0, color code CC40, module diagnostics **==> picture [511 x 458] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |||General information| |Product type designation|RQ 4x120VDC-230VAC/5A CO HA| |Firmware version|V1.0| |● FW update possible|Yes| |Usable terminal block|type K0 (see system manual for details)| |Color code for module-specific color-coded label|CC40| |ee|Product function| |● I&M data|Yes; I&M0 to I&M3| |I|Engineering with|__| |● STEP 7 TIA Portal configurable/integrated from version|V16| |● STEP 7 configurable/integrated from version|V5.6| |● PCS 7 configurable/integrated from version|V9.0| |● PCS neo can be configured/integrated from version|V3.0| |● PROFINET from GSD version/GSD revision|GSDML V2.3| |ee|Redundancy| |● Redundancy capability|No| |||Supply voltage| |Rated value (DC)|24 V| |permissible range, lower limit (DC)|19.2 V| |permissible range, upper limit (DC)|28.8 V| |Reverse polarity protection|Yes| |||Input current| |Current consumption (rated value)|50 mA; At 24 V and energized changeover coils| |Current consumption, max.|60 mA; At 19.2 V and energized changeover coils| |||Power loss| |Power loss, typ.|2.8 W; At 24 V, energized changeover coils and 5 A current across each| |changeover contact| |Address area| |EEEEE——|Address space per module| |● Address space per module, max.|1 byte; + 1 byte for QI information| |||Digital outputs| |Number of digital outputs|4| |I|Switching frequency|__| |● with resistive load, max.|2 Hz| |● with inductive load, max.|0.5 Hz| |● on lamp load, max.|2 Hz| **----- End of picture text -----**<br> Subject to change without notice © Copyright Siemens 6DL11326HD500PK0 Page 1/3 5/15/2026 |Relayoutputs|||| |---|---|---|---| |● Number of relayoutputs|4||| |● externalprotection for relayoutputs|yes; 6 A, see data in manual||| |Switchingcapacityof contacts|||| |— with inductive load, max.|2 A; 2 A(24 V DC), 0.5 A(60 V DC), 0.1 A(120 V DC)||| |— with resistive load, max.|5 A; 5 A(30 V DC), 5 A(230 V AC)||| |— Switchingcurrent, min.|8 mA||| |— Rated switchingvoltage(DC)|24 V; 24 V DC to 120 V DC||| |— Rated switchingvoltage(AC)|230 V; 24V AC to 230V AC||| |Cable length|||| |● shielded, max.|1 000 m||| |● unshielded, max.|200 m||| |**Interrupts/diagnostics/status information**|||| |Diagnostics function|Yes||| |Substitute values connectable|Yes||| |Alarms|||| |● Diagnostic alarm|Yes||| |Diagnoses|||| |● Monitoringthe supplyvoltage|Yes||| |—parameterizable|Yes||| |Diagnostics indication LED|||| |● MAINT LED|Yes; Yellow LED||| |● Monitoringof the supplyvoltage(PWR-LED)|Yes;green PWR LED||| |● Channel status display|Yes;green LED||| |● for module diagnostics|Yes;green/red DIAG LED||| |**Potential separation**|||| |Potential separation channels|||| |● between the channels|Yes||| |● between the channels and backplane bus|Yes||| |● Between the channels and load voltage L+|Yes||| |**Permissible potential difference**|||| |between different circuits|Between channels: 230 V AC(different systemphase)||| |between channels and backplane bus/supplyvoltage|230 V AC||| |**Isolation**|||| |tested with|||| |● between channels and backplane bus/supplyvoltage|4 200 V DC/1 min, type test||| |● between backplane bus and supplyvoltage|1 500 V DC/1 min, type test||| |● Between channels|1 500 V AC/1 min, type test||| |**Ambient conditions**|||| |Ambient temperature duringoperation|||| |● horizontal installation, min.|-40 °C; No icing||| |● horizontal installation, max.|70 °C||| |● vertical installation, min.|-40 °C; No icing||| |● vertical installation, max.|60 °C||| |Altitude duringoperation relatingto sea level|||| |● Ambient air temperature-barometric pressure-altitude|3 000 m due to converter type used||| |**Dimensions**|||| |Width|22.5 mm||| |Height|115 mm||| |Depth|138 mm||| |**Weights**|||| |Weight, approx.|162g||| |**Classifications**|||| |||**Version**|**Classification**| ||eClass<br>eClass<br>eClass|14<br>12<br>9.1|27-24-26-04<br>27-24-26-04<br>27-24-26-04| Subject to change without notice © Copyright Siemens 6DL11326HD500PK0 Page 2/3 5/15/2026 eClass 9 27-24-26-04 eClass 8 27-24-26-04 eClass 7.1 27-24-26-04 eClass 6 27-24-26-04 ETIM 10 EC001599 ETIM 9 EC001599 ETIM 8 EC001599 ETIM 7 EC001599 ~~ee~~ **Approvals / Certificates General Product Approval** ce ec Miscellaneous © & @ **General Product Approval** China RoHS Manufacturer DeclaraMiscellaneous tion c ~~r Sr~~ **For use in hazardous locations Maritime application** Declaration of Conformity ~~—~~ © © aa **Maritime application Environment** - - NK / Nippon Kaiji Ky CCS (China Classifica okai tion Society) ~~=~~ & ~~—~~ EPD sanane **last modified:** 4/30/2026 Subject to change without notice © Copyright Siemens 6DL11326HD500PK0 Page 3/3 5/15/2026
Updated at June 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →