Image not available
Illustrative purposes only
6AG2333-0SB00-4AY0
Isolated DIN Rail Mount DC/DC Converter, Railway, 2:1, 120 W, 1 Output, 24 V, 5 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Isolated DIN Rail Mount DC / DC Converters
- SVHC: To Be Advised
- Depth: 125mm
- Width: 42mm
- Height: 125mm
- Input Ratio: 2:1
- Product Range: SIPLUS PS PSU2600 Series
- No. of Outputs: 1 Output
- Output Power Max: 120W
- Isolation Voltage: -
- Output Regulation: -
- Input Voltage DC Max: 154V
- Input Voltage DC Min: 77V
- Input Voltage DC Nom: 110V
- Output Current - Output 1: 5A
- Output Current - Output 2: -
- Output Voltage - Output 1: 24V
- Output Voltage - Output 2: -
- Power Supply Applications: Railway
- DC / DC Converter Output Type: Fixed, Adjustable
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 383.67 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6AG2333-0SB00-4AY0** **Data sheet** SIPLUS PS PSU2600 24V5A TX RAIL SIPLUS PS PSU2600 24V/5A TX rail input: 110 V DC, output: 24 V DC/5 A, - 40…+70 °C, OT4 with ST1/2 (+85 °C for 10 minutes), ## **General information** |4<br>a<br>ty<br>8<br>Z<br><—<br>it)a<br>_<br>Tr<br>ce<br>a<br>Ii<br>ihe|SIPLUS PS PSU2600 24V5A TX RAIL<br>SIPLUS PS PSU2600 24V/5A TX rail input: 110 V DC, output: 24 V DC/5 A, -<br>40…+70 °C, OT4 with ST1/2 (+85 °C for 10 minutes),| |---|---| |**General information**|| |Technical Product Detail Page|https://i.siemens.com/1P6AG2333-0SB00-4AY0| |manufacturer's article number of the basic version used for<br>SIPLUS product versions|6EP4333-0SB00-0AY0| |**input**|| |type of thepower supplynetwork|DC voltage| |supplyvoltage at DC|110 V| |input voltage at DC|77 ... 154 V| |wide range input|Yes| |buffering time for rated value of the output current in the event of<br>power failure minimum|20 ms| |operatingcondition of the mains buffering|at Vin = 110 V| |input current|| |● at rated input voltage 110 V|1.2 A| |current limitation of inrush current at 25 °C maximum|25 A| |fuseprotection type|internal| |fuse protection type in the feeder|None required. Fuse protection startingfrom 6 A Char. C possible| |**output**|| |voltage curve at output|Controlled, isolated DC voltage| |output voltage at DC rated value|24 V| |output voltage|| |● at output 1 at DC rated value|24 V| |output voltage adjustable|Yes; viapotentiometer| |adjustable output voltage|24 ... 28.8 V; max. 120 W| |relative overall tolerance of the voltage|3 %| |relative controlprecision of the output voltage|| |● on slow fluctuation of input voltage|0.1 %| |● on slow fluctuation of ohm loading|0.2 %| |residual ripple|| |● maximum|50 mV| |voltagepeak|| |● maximum|200 mV| |displayversion for normal operation|Green LED for 24 V OK| |type of signal at output|Relaycontact(NO contact, rating60 V DC/ 0.3 A)for "24 V OK"| |behavior of the output voltage when switchingon|No overshoot of Vout(soft start)| |response delaymaximum|1.5 s| |voltage increase time of the output voltage|| |● maximum|500 ms| |output current|| 6AG23330SB004AY0 Page 1/4 Subject to change without notice © Copyright Siemens 5/19/2026 ||● rated value|5 A|| |---|---|---|---| ||● rated range|0 ... 5 A; 5 A upto +60°C; 4 A upto +70°C|| ||supplied activepower typical|120 W|| ||constant overload current||| ||● on short-circuitingduringthe start-uptypical|6 A|| ||bridgingof equipment|No|| ||**efficiency**||| ||efficiencyinpercent|87 %|| ||power loss[W]||| ||● at rated output voltage for rated value of the output<br>current typical|17.5 W|| ||● duringno-load operation maximum|1 W|| ||**closed-loop control**||| ||relative control precision of the output voltage with rapid<br>fluctuation of the input voltage by+/- 15% typical|0.1 %|| ||relative control precision of the output voltage load step of<br>resistive load 50/100/50 % typical|1 %|| ||settingtime||| ||● load step50 to 100% typical|0.2 ms|| ||● load step100 to 50% typical|0.2 ms|| ||relative control precision of the output voltage at load step of<br>resistive load 10/90/10 % typical|2 %|| ||settingtime||| ||● load step10 to 90% typical|0.2 ms|| ||● load step90 to 10% typical|0.2 ms|| ||● maximum|10 ms|| ||**protection and monitoring**||| ||design of the overvoltageprotection|< 32 V|| ||propertyof the output short-circuitproof|Yes|| ||design of short-circuitprotection|Shutdown andperiodic restart attempts|| ||● typical|6 A|| ||enduringshort circuit current RMS value||| ||● typical|6 A|| ||**safety**||| ||galvanic isolation between input and output|Yes|| ||galvanic isolation|Output voltage: SELV, ES1(IEC 62368-1), DVC As(IEC 61204-7)|| ||operatingresourceprotection class|Class I|| ||leakage current||| ||● maximum|3.5 mA|| ||● typical|1.1 mA|| ||protection class IP|IP20|| ||**EMC**||| ||standard||| ||● for emitted interference|EN 50121-3-2|| ||● for interference immunity|EN 50121-3-2|| ||**standards, specifications, approvals**||| ||certificate of suitability||| ||● CE marking|Yes|| ||**standards, specifications, approvals other**||| ||certificate of suitability||| ||● railwayapplication in accordance with EN 50121-3-2|Yes; EMC for rail vehicles|| ||● railwayapplication in accordance with EN 50124-1|Yes; Rail vehicles - Overvoltage categoryOV2; Pollution degree PD2|| ||● railwayapplication in accordance with EN 50125-1|Yes; Rail vehicles - see ambient conditions|| ||● railway application in accordance with EN 50155|Yes; Rail vehicles - Temperature class OT4/ST1/ST2 max. 4 A, horizontal<br>installation, interruption class S3, switchingclass C1|| ||● railwayapplication in accordance with EN 61373|Yes; Rail vehicles - vibrations and shocks: Category1 Class A/B|| ||● fire protection in accordance with EN 45545-2|Yes; Rail vehicles - proof on request|| ||**ambient conditions**||| ||ambient temperature||| ||● in horizontal mounting position during operation|-40 ... +70 °C; +85 °C for 10 min (OT4/ST1/ST2 acc. to EN 50155 at max. 4 A)|| 6AG23330SB004AY0 Page 2/4 Subject to change without notice © Copyright Siemens 5/19/2026 |● duringtransport|● duringtransport|-40 ... +85 °C|-40 ... +85 °C|-40 ... +85 °C| |---|---|---|---|---| |● duringstorage||-40 ... +85 °C||| |installation altitude at height above sea level maximum||5 000 m||| |ambient condition relating to ambient temperature - air pressure<br>- installation altitude||In case of operation at altitudes of 2000 - 5000 m above sea level: Output<br>power derating of -7.5 %/1000 m or reduction of the ambient temperature by 5<br>K/1000 m||| |type of coating for electronic devices in railway applications<br>accordingto EN 50155||Yes; Protective coating of Class PC2 acc. to EN 50155:2017||| |**connection method**||||| |type of electrical connection||screw terminal||| |● at input||Input, output and ground: 1 screw terminal each for 0.2 ... 2.5 mm² single-<br>core/finelystranded||| |● at output||+, -: 2 screw terminals each for 0.2 ... 2.5 mm²||| |● for auxiliarycontacts||13, 14(alarm signal): 1 screw terminal each for 0.05 ... 2.5 mm²||| |**mechanical data**||||| |width × height × depth of the enclosure||42 × 125 × 125 mm||| |installation width × mountingheight||42 mm × 225 mm||| |required spacing||||| |● top||50 mm||| |● bottom||50 mm||| |● left||0 mm||| |● right||0 mm||| |fasteningmethod||Snaps onto DIN rail EN 60715 35x7.5/15||| |● DIN-rail mounting||Yes||| |● S7 rail mounting||No||| |● wall mounting||No||| |housingcan be lined up||Yes||| |net weight||0.6 kg||| |**further information internet links**||||| |internet link||||| |● to website: IndustryMall||https://mall.industry.siemens.com||| |● to website: IndustryOnline Support||https://support.industry.siemens.com||| |**additional information**||||| |other information||Specifications at rated input voltage and ambient temperature +25 °C (unless<br>otherwise specified)||| |**security information**||||| |security information||Siemens provides products and solutions with industrial cybersecurity functions<br>that support the secure operation of plants, systems, machines and networks.<br>In order to protect plants, systems, machines and networks against cyber<br>threats, it is necessary to implement - and continuously maintain - a holistic,<br>state-of-the-art industrial cybersecurity concept. Siemens’ products and<br>solutions constitute one element of such a concept. Customers are responsible<br>for preventing unauthorized access to their plants, systems, machines and<br>networks. Such systems, machines and components should only be connected<br>to an enterprise network or the internet if and to the extent such a connection is<br>necessary and only when appropriate security measures (e.g. firewalls and/or<br>network segmentation) are in place. For additional information on industrial<br>cybersecurity measures that may be implemented, please visit<br>www.siemens.com/cybersecurity-industry. Siemens’ products and solutions<br>undergo continuous development to make them more secure. Siemens strongly<br>recommends that product updates are applied as soon as they are available<br>and that the latest product versions are used. Use of product versions that are<br>no longer supported, and failure to apply the latest updates may increase<br>customer’s exposure to cyber threats. To stay informed about product updates,<br>subscribe to the Siemens Industrial Cybersecurity RSS Feed under<br>https://www.siemens.com/cert.(V4.7)||| |**Classifications**||||| ||||**Version**|**Classification**| |||eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass|14<br>12<br>9.1<br>9<br>8<br>7.1|27-04-07-01<br>27-04-07-01<br>27-04-07-01<br>27-04-07-01<br>27-04-90-02<br>27-04-90-02| |● duringtransport|● duringtransport|-40 ... +85 °C|-40 ... +85 °C|-40 ... +85 °C| |---|---|---|---|---| |● duringstorage||-40 ... +85 °C||| |installation altitude at height above sea level maximum||5 000 m||| |ambient condition relating to ambient temperature - air pressure<br>- installation altitude||In case of operation at altitudes of 2000 - 5000 m above sea level: Output<br>power derating of -7.5 %/1000 m or reduction of the ambient temperature by 5<br>K/1000 m||| |type of coating for electronic devices in railway applications<br>accordingto EN 50155||Yes; Protective coating of Class PC2 acc. to EN 50155:2017||| |**connection method**||||| |type of electrical connection||screw terminal||| |● at input||Input, output and ground: 1 screw terminal each for 0.2 ... 2.5 mm² single-<br>core/finelystranded||| |● at output||+, -: 2 screw terminals each for 0.2 ... 2.5 mm²||| |● for auxiliarycontacts||13, 14(alarm signal): 1 screw terminal each for 0.05 ... 2.5 mm²||| |**mechanical data**||||| |width × height × depth of the enclosure||42 × 125 × 125 mm||| |installation width × mountingheight||42 mm × 225 mm||| |required spacing||||| |● top||50 mm||| |● bottom||50 mm||| |● left||0 mm||| |● right||0 mm||| |fasteningmethod||Snaps onto DIN rail EN 60715 35x7.5/15||| |● DIN-rail mounting||Yes||| |● S7 rail mounting||No||| |● wall mounting||No||| |housingcan be lined up||Yes||| |net weight||0.6 kg||| |**further information internet links**||||| |internet link||||| |● to website: IndustryMall||https://mall.industry.siemens.com||| |● to website: IndustryOnline Support||https://support.industry.siemens.com||| |**additional information**||||| |other information||Specifications at rated input voltage and ambient temperature +25 °C (unless<br>otherwise specified)||| |**security information**||||| |security information||Siemens provides products and solutions with industrial cybersecurity functions<br>that support the secure operation of plants, systems, machines and networks.<br>In order to protect plants, systems, machines and networks against cyber<br>threats, it is necessary to implement - and continuously maintain - a holistic,<br>state-of-the-art industrial cybersecurity concept. Siemens’ products and<br>solutions constitute one element of such a concept. Customers are responsible<br>for preventing unauthorized access to their plants, systems, machines and<br>networks. Such systems, machines and components should only be connected<br>to an enterprise network or the internet if and to the extent such a connection is<br>necessary and only when appropriate security measures (e.g. firewalls and/or<br>network segmentation) are in place. For additional information on industrial<br>cybersecurity measures that may be implemented, please visit<br>www.siemens.com/cybersecurity-industry. Siemens’ products and solutions<br>undergo continuous development to make them more secure. Siemens strongly<br>recommends that product updates are applied as soon as they are available<br>and that the latest product versions are used. Use of product versions that are<br>no longer supported, and failure to apply the latest updates may increase<br>customer’s exposure to cyber threats. To stay informed about product updates,<br>subscribe to the Siemens Industrial Cybersecurity RSS Feed under<br>https://www.siemens.com/cert.(V4.7)||| |**Classifications**||||| ||||**Version**|**Classification**| |||eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass|14<br>12<br>9.1<br>9<br>8<br>7.1|27-04-07-01<br>27-04-07-01<br>27-04-07-01<br>27-04-07-01<br>27-04-90-02<br>27-04-90-02| |||**Version**|**Classification**|| |---|---|---|---|---| ||eClass|14|27-04-07-01|| ||eClass|12|27-04-07-01|| ||eClass|9.1|27-04-07-01|| ||eClass|9|27-04-07-01|| ||eClass|8|27-04-90-02|| ||eClass|7.1|27-04-90-02|| 6AG23330SB004AY0 Page 3/4 Subject to change without notice © Copyright Siemens 5/19/2026 |eClass|6|27-04-90-02| |---|---|---| |ETIM|10|EC002540| |ETIM|9|EC002540| |ETIM|8|EC002540| |ETIM|7|EC002540| |IDEA|4|4130| |UNSPSC|15|39-12-10-04| ~~a~~ **Approvals Certificates General Product Approval** Manufacturer DeclaraChina RoHS tion ~~—~~ ce EAL ~~_~~ ce UK **Railway** Confirmation **last modified:** 5/5/2026 6AG23330SB004AY0 Page 4/4 Subject to change without notice © Copyright Siemens 5/19/2026
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →