Image not available
Illustrative purposes only
6AG1732-0AA00-7AA0
Isolated DIN Rail Mount DC/DC Converter, ITE, 3:1, 48 W, 1 Output, 24 V, 2 A
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Isolated DIN Rail Mount DC / DC Converters
- SVHC: To Be Advised
- Depth: 120mm
- Width: 80mm
- Height: 135mm
- Input Ratio: 3:1
- Product Range: SIPLUS PS Series
- No. of Outputs: 1 Output
- Output Power Max: 48W
- Isolation Voltage: -
- Output Regulation: -
- Input Voltage DC Max: 121V
- Input Voltage DC Min: 38V
- Input Voltage DC Nom: -
- Output Current - Output 1: 2A
- Output Current - Output 2: -
- Output Voltage - Output 1: 24V
- Output Voltage - Output 2: -
- Power Supply Applications: ITE
- DC / DC Converter Output Type: Fixed, Adjustable
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 644.3 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6AG1732-0AA00-7AA0** **Data sheet** SIPLUS PS DC/DC 24 V/2 A *** spare part *** SIPLUS PS DC/DC 24V/2A based on 6EP1732-0AA00 with conformal coating, 0...+70 °C, SITOP Power 2 A, DC/DC stabilized power supply input: 48/60/110 V DC output: 24 V DC/2 A ## **General information** |SIPLUS PS DC/DC 24 V/2 A<br>*** spare part *** SIPLUS PS DC/DC 24V/2A based on 6EP1732-0AA00 with<br>conformal coating, 0...+70 °C, SITOP Power 2 A, DC/DC stabilized power supply<br>input: 48/60/110 V DC output: 24 V DC/2 A<br>**General information**<br>manufacturer's article number of the basic version used for<br>SIPLUS product versions<br>6EP1732-0AA00<br>**input**<br>type of thepower supplynetwork<br>DC voltage<br>supplyvoltage at DC<br>48 ... 110 V<br>input voltage at DC<br>38 ... 121 V<br>wide range input<br>Yes<br>overvoltage overload capability<br>-<br>buffering time for rated value of the output current in the event of<br>power failure minimum<br>5 ms<br>operatingcondition of the mains buffering<br>at Vin = 48 V<br>input current<br>● at rated input voltage 48 V<br>1.2 A<br>● at rated input voltage 110 V<br>0.5 A<br>current limitation of inrush current at 25 °C maximum<br>33 A<br>fuseprotection type<br>T 2.5 A(not accessible)<br>fuse protection type in the feeder<br>Recommended miniature circuit breaker: 10 to 25 A characteristic B or 6 to 25<br>A characteristic C, suitable for DC<br>**output**<br>voltage curve at output<br>Controlled, isolated DC voltage<br>output voltage at DC rated value<br>24 V<br>output voltage<br>● at output 1 at DC rated value<br>24 V<br>output voltage adjustable<br>Yes; viapotentiometer<br>adjustable output voltage<br>23.5 ... 26.5 V<br>relative overall tolerance of the voltage<br>1 %<br>relative controlprecision of the output voltage<br>● on slow fluctuation of input voltage<br>0.1 %<br>● on slow fluctuation of ohm loading<br>0.4 %<br>residual ripple<br>● maximum<br>100 mV<br>voltagepeak<br>● maximum<br>300 mV<br>displayversion for normal operation<br>Green LED for 24 V OK<br>behavior of the output voltage when switchingon<br>Overshoot of Vout on startupmax. 25 V<br>response delaymaximum<br>3 s<br>voltage increase time of the output voltage<br>● typical<br>30 ms<br>a<br>SIEMENg=<br>SITOP<br>Peiwas<br>bests<br>YY<br>ivy<br>"<br>Figure similar|SIPLUS PS DC/DC 24 V/2 A<br>*** spare part *** SIPLUS PS DC/DC 24V/2A based on 6EP1732-0AA00 with<br>conformal coating, 0...+70 °C, SITOP Power 2 A, DC/DC stabilized power supply<br>input: 48/60/110 V DC output: 24 V DC/2 A|| |---|---|---| ||Controlled, isolated DC voltage|| ||24 V|| |||| ||24 V|| ||Yes; viapotentiometer|| ||23.5 ... 26.5 V|| ||1 %|| |||| ||0.1 %|| ||0.4 %|| |||| ||100 mV|| |||| ||300 mV|| ||Green LED for 24 V OK|| ||Overshoot of Vout on startupmax. 25 V|| ||3 s|| |||| ||30 ms|| 6AG17320AA007AA0 Page 1/4 Subject to change without notice © Copyright Siemens 5/19/2026 |output current|| |---|---| |● rated value|2 A| |● rated range|0 ... 2 A| |supplied activepower typical|48 W| |bridgingof equipment|Yes| |number of parallel-switched equipment resources for increasing<br>the power|2| |**efficiency**|| |efficiencyinpercent|84 %| |power loss[W]|| |● at rated output voltage for rated value of the output<br>current typical|9 W| |**closed-loop control**|| |relative control precision of the output voltage with rapid<br>fluctuation of the input voltage by+/- 15% typical|0.3 %| |relative control precision of the output voltage load step of<br>resistive load 50/100/50 % typical|0.8 %| |settingtime|| |● load step50 to 100% typical|2.5 ms| |● load step 100 to 50% typical|2.5 ms| |**protection and monitoring**|| |design of the overvoltageprotection|Yes, suppressor diode at output| |propertyof the output short-circuitproof|Yes| |design of short-circuitprotection|Electronic shutdown, automatic restart| |response value current limitation|2.1 ... 3 A| |enduringshort circuit current RMS value|| |● maximum|2 A| |**safety**|| |galvanic isolation between input and output|Yes| |galvanic isolation|Safetyextra low output voltage Vout accordingto EN 60950-1| |operatingresourceprotection class|Class I| |leakage current|| |● maximum|3.5 mA| |● typical|0.7 mA| |protection class IP|IP20| |**EMC**|| |standard|| |● for emitted interference|EN 55022 Class B| |● for mains harmonics limitation|not applicable| |● for interference immunity|EN 61000-6-2| |**standards, specifications, approvals**|| |certificate of suitability|| |● CE marking|Yes| |MTBF at 40 °C|1 580 078 h| |**ambient conditions**|| |ambient temperature|| |● in horizontal mounting position duringoperation|0 ... 70 °C; with natural convection| |● duringtransport|-40 ... +85 °C| |● duringstorage|-40 ... +85 °C| |installation altitude at height above sea level maximum|6 000 m| |ambient condition relating to ambient temperature - air pressure<br>- installation altitude|In case of operation at altitudes of 2000 - 6000 m above sea level: Output<br>power derating of -7.5 %/1000 m or reduction of the ambient temperature by 5<br>K/1000 m| |relative humidity with condensation according to IEC 60068-2-<br>38 maximum|100 %; RH incl. condensation/frost (no commissioning if condensation is<br>present), horizontal installation| |chemical resistance to commerciallyavailable coolinglubricants|Yes; incl. diesel and oil droplets in the air| |resistance to biologically active substances conformity<br>accordingto EN 60721-3-3|Yes; Class 3B2 mold, fungal, sponge spores (except fauna); class 3B3 upon<br>request| |resistance to chemically active substances conformity according<br>to EN 60721-3-3|Yes; Class 3C4 (RH < 75%) incl. salt spray acc. to EN 60068-2-52 (severity<br>level 3)| |resistance to mechanically active substances conformity|Yes; Class 3S4 incl. sand, dust| 6AG17320AA007AA0 Page 2/4 Subject to change without notice © Copyright Siemens 5/19/2026 |accordingto EN 60721-3-3|||| |---|---|---|---| |resistance to biologically active substances conformity<br>accordingto EN 60721-3-6|Yes; Class 6B2 mold, fungal, sponge spores (except fauna)||| |resistance to chemically active substances conformity according<br>to EN 60721-3-6|Yes; Class 6C3 (RH < 75%) incl. salt spray acc. to EN 60068-2-52 (severity<br>level 3)||| |resistance to mechanically active substances conformity<br>accordingto EN 60721-3-6|Yes; Class 6S3 incl. sand, dust||| |coating for equipped printed circuit board according to EN<br>61086|Yes; Class 2 for high availability||| |type of coating protection against pollution according to EN<br>60664-3|Yes; Type 1 protection||| |type of test of the coatingaccordingto MIL-I-46058C|Yes; Discoloration of the coatingduringservice lifepossible||| |product conformity of the coating Qualification and Performance<br>of Electrical Insulating Compound for Printed Board Assemblies<br>accordingto IPC-CC-830A|Yes; Conformal Coating, Class A||| |**connection method**|||| |type of electrical connection|screw terminal||| |● at input|L+, M1, PE: 1 screw terminal each for 2 x 0.5 ... 2.5/1.5 mm² single-core/finely<br>stranded||| |● at output|L+, M: 1 screw terminal each for 2 x 0.5 ... 2.5 mm²||| |● for auxiliarycontacts|-||| |**mechanical data**|||| |width × height × depth of the enclosure|80 × 135 × 120 mm||| |installation width × mountingheight|80 mm × 235 mm||| |required spacing|||| |● top|50 mm||| |● bottom|50 mm||| |● left|0 mm||| |● right|0 mm||| |fasteningmethod|Snaps onto DIN rail EN 60715 35x15||| |● DIN-rail mounting|Yes||| |● S7 rail mounting|No||| |● wall mounting|No||| |housingcan be lined up|Yes||| |net weight|0.5 kg||| |**further information internet links**|||| |internet link|||| |● to website: IndustryOnline Support|https://support.industry.siemens.com||| |**additional information**|||| |other information|Specifications at rated input voltage and ambient temperature +25 °C (unless<br>otherwise specified)||| |**security information**|||| |security information|Siemens provides products and solutions with industrial cybersecurity functions<br>that support the secure operation of plants, systems, machines and networks.<br>In order to protect plants, systems, machines and networks against cyber<br>threats, it is necessary to implement - and continuously maintain - a holistic,<br>state-of-the-art industrial cybersecurity concept. Siemens’ products and<br>solutions constitute one element of such a concept. Customers are responsible<br>for preventing unauthorized access to their plants, systems, machines and<br>networks. Such systems, machines and components should only be connected<br>to an enterprise network or the internet if and to the extent such a connection is<br>necessary and only when appropriate security measures (e.g. firewalls and/or<br>network segmentation) are in place. For additional information on industrial<br>cybersecurity measures that may be implemented, please visit<br>www.siemens.com/cybersecurity-industry. Siemens’ products and solutions<br>undergo continuous development to make them more secure. Siemens strongly<br>recommends that product updates are applied as soon as they are available<br>and that the latest product versions are used. Use of product versions that are<br>no longer supported, and failure to apply the latest updates may increase<br>customer’s exposure to cyber threats. To stay informed about product updates,<br>subscribe to the Siemens Industrial Cybersecurity RSS Feed under<br>https://www.siemens.com/cert.(V4.7)||| |**Classifications**|||| |||**Version**|**Classification**| ||eClass|14|27-04-07-01| 6AG17320AA007AA0 Page 3/4 Subject to change without notice © Copyright Siemens 5/19/2026 **==> picture [218 x 168] intentionally omitted <==** **----- Start of picture text -----**<br> |||| |---|---|---| |eClass|12|27-04-07-01| |eClass|9.1|27-04-07-01| |eClass|9|27-04-07-01| |eClass|8|27-04-90-02| |eClass|7.1|27-04-90-02| |eClass|6|27-04-90-02| |ETIM|10|EC002540| |ETIM|9|EC002540| |ETIM|8|EC002540| |ETIM|7|EC002540| |IDEA|4|4130| |UNSPSC|15|39-12-10-04| **----- End of picture text -----**<br> **==> picture [148 x 70] intentionally omitted <==** **----- Start of picture text -----**<br> ||| |---|---| |Approvals Certificates| |General Product Approval| |Manufacturer Declara-|China RoHS| |tion| |ee| **----- End of picture text -----**<br> **last modified:** 5/5/2026 6AG17320AA007AA0 Page 4/4 Subject to change without notice © Copyright Siemens 5/19/2026
Updated at April 17, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →