- Manufacturer: SIEMENS
- Product type: AC / DC Enclosed Power Supplies
- Product Range: SIPLUS S7-300 Series
- No. of Outputs: 1Outputs
- Output Power Max: 18W
- Current, Output 4: -
- Input Voltage VAC: 170V AC to 264V AC
- Power Supply Output Type: Fixed
- Output Current - Output 1: 5A
- Output Current - Output 2: -
- Output Current - Output 3: -
- Output Voltage - Output 1: 24VDC
- Output Voltage - Output 2: -
- Output Voltage - Output 3: -
- Output Voltage - Output 4: -
- Power Supply Applications: ITE
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 296.67 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6AG1307-1EA01-7AA0** **Data sheet** ***spare part*** SIPLUS S7-300 PS 307 based on 6ES7307-1EA01-0AA0 with conformal coating, -25…+70 °C, stabilized power supply input: 120/230 V AC output: 24 V DC/5 A |**General information**|| |---|---| |based on|6ES7307-1EA01-0AA0| |**Supply voltage**|| |Rated value(AC)|| |● 120 V AC|Yes; 85 to 132 V AC| |● 230 V AC|Yes; 170 to 264 V AC| |Overvoltage strength|2.3x Ue rated, 1.3 ms| |Line frequency|| |●permissible range, lower limit|47 Hz| |●permissible range, upper limit|63 Hz| |Mains buffering|| |● Mains/voltage failure stored energytime|20 ms; min., for Ia rated| |● Repeat rate, min.|1 s| |**Input current**|| |Rated value at 120 V AC|2.3 A| |Rated value at 230 V AC|1.2 A| |Inrush current, max.|20 A; max. at 25 °C, duration max. 3 ms| |I²t|1.2 A²·s| |Leakage current, typ.|0.5 mA| |Leakage current, max.|3.5 mA| |**Output voltage**|| |Rated value(DC)|24 V| |permissible range, lower limit(DC)|23.27 V| |permissible range, upper limit(DC)|24.72 V| |Power uptime, max.|2 s| |Voltage rise time, typ.|10 ms| |Overvoltageprotection|Additional control circuit, cutoff at < 28.8 V, automatic restart| |Short-circuitprotection|electronic trip, automatic restart| |Residual ripple, typ.|10 mV; Peak -peak| |Residual ripple, max.|50 mV; Peak - peak| |**Output current**|| |Current output(rated value)|5 A; 3 A@> 60 °C, can be switched in parallel| |**Power**|| |Activepower input, typ.|138 W| |Efficiency|87 %; approx., at Ua rated, Ia rated| |**Power loss**|| |Power loss, typ.|18 W; approx., at Ua rated, Ia rated| |**Interrupts/diagnostics/status information**|| 6AG13071EA017AA0 Page 1/3 Subject to change without notice © Copyright Siemens 5/19/2026 ||Diagnostics indication LED||||| |---|---|---|---|---|---| ||● Status indicator output 24 V OK(green)|Yes|||| ||**Potential separation**||||| ||primary/secondary|Yes; SELV output voltage Ua accordingto EN 60950-1 and EN 50178|||| ||**Isolation**||||| ||Isolation tested with|Rated insulation voltage(24 V against L1)250 V AC, tested with 4 200 V DC|||| ||**EMC**||||| ||EMC interference immunity|EN 61000-6-2|||| ||EMC interference emission|EN 55022 Class B|||| ||**Degree and class of protection**||||| ||Equipment protection class|I|||| ||**Standards, approvals, certificates**||||| ||CE mark|Yes|||| ||Standard for line harmonics limit|EN 61000-3-2|||| ||**Ambient conditions**||||| ||Ambient temperature duringoperation||||| ||● min.|-25 °C; = Tmin|||| ||● max.|70 °C; = Tmax; 60 °C@UL/cUL, ATEX and FM use|||| ||Altitude duringoperation relatingto sea level||||| ||● Installation altitude above sea level, max.|2 000 m|||| ||● Ambient air temperature-barometric pressure-altitude|Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax<br>- 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K)<br>at 658 hPa ... 540 hPa(+3 500 m ... +5 000 m); above 2 000 m max. 75 V DC|||| ||Relative humidity||||| ||● With condensation, tested in accordance with IEC 60068-<br>2-38, max.|100 %; RH incl. condensation/frost (no commissioning under condensation<br>conditions)|||| ||Resistance||||| ||Use in stationaryindustrial systems||||| ||— to biologically active substances according to EN<br>60721-3-3|Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna);<br>Class 3B3 on request|||| ||— to chemically active substances according to EN<br>60721-3-3|Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity<br>degree 3); *|||| ||— to mechanically active substances according to EN<br>60721-3-3|Yes; Class 3S4 incl. sand, dust, *|||| ||Use on ships/at sea||||| ||— to biologically active substances according to EN<br>60721-3-6|Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on<br>request|||| ||— to chemically active substances according to EN<br>60721-3-6|Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity<br>degree 3); *|||| ||— to mechanically active substances according to EN<br>60721-3-6|Yes; Class 6S3 incl. sand, dust; *|||| ||Usage in industrialprocess technology||||| ||— Against chemically active substances acc. to EN<br>60654-4|Yes; Class 3 (excluding trichlorethylene)|||| ||— Environmental conditions for process, measuring<br>and control systems acc. to ANSI/ISA-71.04|Yes; Level GX group A/B (excluding trichlorethylene; harmful gas<br>concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level<br>LC3(salt spray)and level LB3(oil)|||| ||Remark||||| ||— Note regarding classification of environmental<br>conditions acc. to EN 60721, EN 60654-4 and<br>ANSI/ISA-71.04|* The supplied plug covers must remain in place over the unused interfaces<br>during operation!|||| ||**Dimensions**||||| ||Width|60 mm|||| ||Height|125 mm|||| ||Depth|120 mm|||| ||**Weights**||||| ||Weight, approx.|0.6 kg|||| ||**Classifications**||||| ||||**Version**|**Classification**|| |||eClass<br>eClass<br>eClass|14<br>12<br>9.1|27-24-22-09<br>27-24-22-09<br>27-24-22-09|| 6AG13071EA017AA0 Page 2/3 Subject to change without notice © Copyright Siemens 5/19/2026 ||||eClass||9<br>27-24-22-09| |---|---|---|---|---|---| ||||eClass||8<br>27-24-22-09| ||||eClass||7.1<br>27-24-22-09| ||||eClass||6<br>27-24-22-09| ||||ETIM||10<br>EC000599| ||||ETIM||9<br>EC000599| ||||ETIM||8<br>EC000599| ||||ETIM||7<br>EC000599| ||||IDEA||4<br>3575| ||||UNSPSC||15<br>32-15-17-06| |**Approvals / Certificates**|||||| |**General Product Approval**|||||| |ce|es|Manufacturer Declara-<br>tion|China RoHS||©<br>EF| |**General Product Approval**||**EMV**|||**For use in hazardous locations**| |Cc|UK<br>eg|fk|@||CCC-Ex<br>~~—~~<br>Cy| **For use in hazardous locations** **last modified:** 5/29/2024 6AG13071EA017AA0 Page 3/3 Subject to change without notice © Copyright Siemens 5/19/2026
Updated at June 4, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 540,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →