Image not available
Illustrative purposes only
6AG1138-6AA00-2BA8
Communication Module, SIWAREX WP321 ST, 24 VDC, RS485 Interface, SIPLUS Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type:
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 957.95 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6AG1138-6AA00-2BA8** **Data sheet** SIPLUS ET 200SP WP321 based on 7MH4138-6AA00-0BA0 with conformal coating, -40…+60 °C, electronic weighing system 1 channel for the connection of load cells DMS full bridges (1-4 mV/V) for SIMATIC ET200SP, suitable for BU type A0, RS485 interface for SIWATOOL or remote display. |**General information**|| |---|---| |Product type designation|TM SIWAREX WP321 ST| |Firmware version|| |● FW updatepossible|Yes| |based on|7MH4138-6AA00-0BA0| |usable BaseUnits|BU type A0| |Color code for module-specific color-coded label|CC00| |Product function|| |● I&M data|Yes; I&M0 to I&M3| |● Isochronous mode|No| |● Adjustment of measuringrange|No| |Engineeringwith|| |● STEP 7 TIA Portal configurable/integrated from version|see entryID: 109746275| |**Supply voltage**|| |Rated value(DC)|24 V| |Load voltage L+|| |● Rated value(DC)|24 V| |●permissible range, lower limit(DC)|19.2 V| |●permissible range, upper limit(DC)|28.8 V| |● Short-circuitprotection|Yes| |● Reverse polarityprotection|Yes| |**Input current**|| |Current consumption, max.|100 mA| |**Encoder supply**|| |Output voltage(DC)|4.85 V| |Short-circuit protection|Yes| |**Power**|| |Power consumption from the backplane bus|70 mW| |**Power loss**|| |Power loss, typ.|2 W| |**Address area**|| |Address spaceper module|| |● Inputs|16 byte| |● Outputs|16 byte| |**Hardware configuration**|| |Automatic encoding|Yes| |● Mechanical codingelement|Yes| |● Type of mechanical coding element|type B| 6AG11386AA002BA8 Page 1/4 Subject to change without notice © Copyright Siemens 5/21/2026 |**Encoder**|**Encoder**| |---|---| |Connection of signal encoders|| |● For strain gauges (full bridges) with 4-conductor<br>connection|Yes| |● For strain gauges (full bridges) with 6-conductor<br>connection|Yes| |● Resistance of full bridge, min.|40 Ω; when using SIWAREX IS: 50 ohm for 7MH4710-5BA; 105 ohm when<br>using7MH4710-5CA| |● Resistance of full bridge, max.|4 100 Ω| |**Errors/accuracies**|| |Linearityerror(relative to input range),(+/-)|0.01 %| |Error limit accordingto DIN 1319-1|0.05 %; of full-scale value| |Temperature coefficient, zeropoint|≤ ±0.1μV/K| |Temperature coefficient, span|≤ ±5ppm/K| |Temperature coefficient, span, 4-wire connection (in relation to<br>end value)|≤ ±5 ppm/K| |Temperature coefficient, span, 6-wire connection (in relation to<br>end value)|≤ ±10 ppm/K| |**Interfaces**|| |Number of RS 485 interfaces|1; SIWATOOL V7 or SIWAREX DB or SIEBERT remote display| |**1. Interface**|| |Interface types|| |● RS 485|Yes; 390 Ω, 220 Ω, 390 Ω connectable termination| |**Interface types**|| |RS 485|| |● Transmission rate, max.|115.2 kbit/s| |● Cable length, max.|1 000 m; ≤ 115 kbps, shielded cable| |**Interrupts/diagnostics/status information**|| |Diagnostics function|Yes; Diagnostic alarm| |Substitute values connectable|No| |Alarms|| |● Diagnostic alarm|Yes; Parameterizable| |● Hardware interrupt|Yes; Parameterizable| |Diagnoses|| |● Monitoringthe supplyvoltage|Yes| |● Wire break|Yes| |● Short-circuit|Yes| |● Grouperror|Yes| |Diagnostics indication LED|| |● ERROR LED|Yes;green/red DIAG LED| |● Monitoringof the supplyvoltage(PWR-LED)|Yes;green PWR LED| |**Integrated Functions**|| |Counter|Yes| |Load cell|| |● Non-automatic weighinginstrument|NAWI| |● Samplingrate|600 Hz| |● Resolution of input signal|±500 000partspro mV/V| |● Common mode voltage, min.|0.25 V| |● Common mode voltage, max.|4.75 V| |● input resistance of signal line, typ.|4 MΩ| |● input resistance of sense line, typ.|2 MΩ| |● Cable length, max.|500 m; when usingthe SIWAREX 7MH4702-8AG cable| |Measuringfunctions|| |Measuringrange|| |— -1 mV/V to +1 mV/V|Yes; corresponds to a resolution of ±500 000parts| |— -2 mV/V to +2 mV/V|Yes; corresponds to a resolution of ±1 000 000parts| |— -4 mV/V to +4 mV/V|Yes; corresponds to a resolution of ±2 000 000 parts| |**Isolation**|| |Isolation tested with|707 V DC(type test)| |**Standards, approvals, certificates**|| 6AG11386AA002BA8 Page 2/4 Subject to change without notice © Copyright Siemens 5/21/2026 ||Suitable for safetyfunctions|No|| |---|---|---|---| ||**Ambient conditions**||| ||Ambient temperature duringoperation||| ||● horizontal installation, min.|-40 °C; = Tmin(incl. condensation/frost)|| ||● horizontal installation, max.|60 °C|| ||● vertical installation, min.|-40 °C; = Tmin(incl. condensation/frost)|| ||● vertical installation, max.|50 °C|| ||Altitude duringoperation relatingto sea level||| ||● Installation altitude above sea level, max.|5 000 m|| ||● Ambient air temperature-barometric pressure-altitude|Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax<br>- 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K)<br>at 658 hPa ... 540 hPa(+3 500 m ... +5 000 m)|| ||Relative humidity||| ||● With condensation, tested in accordance with IEC 60068-<br>2-38, max.|100 %; RH incl. condensation / frost (no commissioning in bedewed state),<br>horizontal installation|| ||Resistance||| ||Coolants and lubricants||| ||— Resistant to commercially available coolants and<br>lubricants|Yes; Incl. diesel and oil droplets in the air|| ||Use in stationaryindustrial systems||| ||— to biologically active substances according to EN<br>60721-3-3|Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna);<br>Class 3B3 on request|| ||— to chemically active substances according to EN<br>60721-3-3|Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity<br>degree 3); *|| ||— to mechanically active substances according to EN<br>60721-3-3|Yes; Class 3S4 incl. sand, dust, *|| ||— Against mechanical environmental conditions acc.<br>to EN 60721-3-3|Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-<br>0AA0)|| ||Use on ships/at sea||| ||— to biologically active substances according to EN<br>60721-3-6|Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna)|| ||— to chemically active substances according to EN<br>60721-3-6|Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity<br>degree 3); *|| ||— to mechanically active substances according to EN<br>60721-3-6|Yes; Class 6S3 incl. sand, dust; *|| ||— Against mechanical environmental conditions acc.<br>to EN 60721-3-6|Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-<br>0AA0)|| ||Usage in industrialprocess technology||| ||— Against chemically active substances acc. to EN<br>60654-4|Yes; Class 3 (excluding trichlorethylene)|| ||— Environmental conditions for process, measuring<br>and control systems acc. to ANSI/ISA-71.04|Yes; Level GX group A/B (excluding trichlorethylene; harmful gas<br>concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level<br>LC3(salt spray)and level LB3(oil)|| ||Remark||| ||— Note regarding classification of environmental<br>conditions acc. to EN 60721, EN 60654-4 and<br>ANSI/ISA-71.04|* The supplied plug covers must remain in place over the unused interfaces<br>during operation!|| ||Conformal coating||| ||● Coatings for printed circuit board assemblies acc. to EN<br>61086|Yes; Class 2 for high reliability|| ||● Protection against foulingacc. to EN 60664-3|Yes; Type 1protection|| ||● Militarytestingaccordingto MIL-I-46058C, Amendment 7|Yes; Discoloration of coating possible duringservice life|| ||● Qualification and Performance of Electrical Insulating<br>Compound for Printed Board Assemblies according to IPC-<br>CC-830A|Yes; Conformal coating, Class A|| ||**Decentralized operation**||| ||to SIMATIC S7-300|Yes|| ||to SIMATIC S7-400|Yes|| ||to SIMATIC S7-1200|Yes|| ||to SIMATIC S7-1500|Yes|| ||to standard PROFIBUS master|Yes|| ||to standard PROFINET controller|Yes|| ||**Dimensions**||| ||Width|15 mm|| ||Height|73 mm|| 6AG11386AA002BA8 Page 3/4 Subject to change without notice © Copyright Siemens 5/21/2026 |Depth<br>~~BC~~|58 mm|58 mm|58 mm| |---|---|---|---| |**Weights**|||| |Weight, approx.|30g||| |**Classifications**<br>~~a~~|||| |eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>ETIM<br>ETIM<br>ETIM<br>ETIM<br>IDEA<br>UNSPSC<br>~~a~~||**Version**<br>~~a~~|**Classification**<br>~~a~~| |||14<br>12<br>9.1<br>9<br>8<br>7.1<br>6<br>10<br>9<br>8<br>7<br>4<br>15|27-24-26-05<br>27-24-26-05<br>27-24-26-05<br>27-24-26-05<br>27-24-26-05<br>27-24-26-05<br>27-24-26-05<br>EC001601<br>EC001601<br>EC001601<br>EC001601<br>3567<br>32-15-17-05| |**Approvals / Certificates**<br>~~a~~|||| |**General Product Approval**<br>~~a~~|||| **last modified:** 10/23/2025 6AG11386AA002BA8 Page 4/4 Subject to change without notice © Copyright Siemens 5/21/2026
Updated at March 31, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →