Image not available
Illustrative purposes only
6AG1136-6PA00-2BC0
Power Module, 75 mA, 24 VDC, 5 W, 72 mm x 20 mm x 55 mm, SIPLUS ET 200SP Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Controller Accessories
- SVHC: To Be Advised
- Product Range: SIPLUS ET 200SP Series
- Current Rating: 75mA
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 601.65 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6AG1136-6PA00-2BC0** **Data sheet** SIPLUS ET 200SP F-PM-E 24VDC/8A PPM based on 6ES7136-6PA00-0BC0 with conformal coating, -30…+60 °C, fail-safe power module PROFIsafe, 24 V DC safe shutdown of DQ and F-DQ up to PL D/SIL2 or PL E/SIL3 2 safe digital inputs 1 safe digital output PPM |SIPLUS ET 200SP F-PM-E 24VDC/8A PPM based on 6ES7136-6PA00-0BC0 with<br>conformal coating, -30…+60 °C, fail-safe power module PROFIsafe, 24 V DC safe<br>shutdown of DQ and F-DQ up to PL D/SIL2 or PL E/SIL3 2 safe digital inputs 1<br>safe digital output PPM<br>**General information**<br>Product type designation<br>F-PM-E 24 V DC/8 A PPM ST<br>based on<br>6ES7136-6PA00-0BC0<br>usable BaseUnits<br>BU type C0<br>Color code for module-specific color-coded label<br>CC52<br>Product function<br>● I&M data<br>Yes; I&M0 to I&M3<br>Engineeringwith<br>● STEP 7 TIA Portal configurable/integrated from version<br>see entryID: 109746275<br>**Supply voltage**<br>Rated value(DC)<br>24 V<br>permissible range, lower limit(DC)<br>20.4 V<br>permissible range, upper limit(DC)<br>28.8 V<br>Reverse polarityprotection<br>Yes<br>**Input current**<br>Current consumption(rated value)<br>75 mA; without load<br>Current consumption, max.<br>21 mA; From the backplane bus<br>**Output voltage**<br>Rated value(DC)<br>24 V<br>**Encoder supply**<br>Number of outputs<br>2<br>Short-circuitprotection<br>Yes; Electronic(response threshold 0.7 A to 2.1 A)<br>Output current<br>● upto 60 °C, max.<br>0.3 A<br>24 V encoder supply<br>● 24 V<br>Yes; min. L+(-1.5 V)<br>● Short-circuitprotection<br>Yes<br>● Output current, max.<br>600 mA; Total current of all encoders<br>**Power**<br>Power consumption from the backplane bus<br>70 mW<br>**Power loss**<br>Power loss, typ.<br>5 W<br>**Address area**<br>Address spaceper module<br>● Inputs<br>7 byte<br>● Outputs<br>5 byte<br>**Hardware configuration**<br>Automatic encoding<br>Yes<br>● Electronic codingelement type F<br>Yes<br>~~|~~<br>~~a~~<br>~~ee~~<br>~~|~~<br>~~Oe~~<br>~~|~~<br>~~|~~<br>~~ee~~<br>~~|~~<br>~~|~~<br>~~|~~<br>~~——=E=~~<br>~~|~~|SIPLUS ET 200SP F-PM-E 24VDC/8A PPM based on 6ES7136-6PA00-0BC0 with<br>conformal coating, -30…+60 °C, fail-safe power module PROFIsafe, 24 V DC safe<br>shutdown of DQ and F-DQ up to PL D/SIL2 or PL E/SIL3 2 safe digital inputs 1<br>safe digital output PPM|| |---|---|---| ||Yes<br>~~|~~|| ||Yes|| |**Digital inputs**|**Digital inputs**| |---|---| |Number of digital inputs|2| |Sourcing/sinkinginput|Yes; P-reading| |Input characteristic curve in accordance with IEC 61131, type 1|Yes| |Input voltage|| |● Type of input voltage|DC| |● Rated value(DC)|24 V| |● for signal "0"|-30 to +5 V| |● for signal "1"|+15 to +30 V| |Input current|| |● for signal "1", typ.|3.7 mA| |Input delay (for rated value of input voltage)|| |for standard inputs|| |—parameterizable|Yes| |— at "0" to "1", min.|0.4 ms| |— at "0" to "1", max.|20 ms| |— at "1" to "0", min.|0.4 ms| |— at "1" to "0", max.|20 ms| |for technological functions|| |—parameterizable|No| |Cable length|| |● shielded, max.|1 000 m| |● unshielded, max.|500 m| |**Digital outputs**|| |Number of digital outputs|1| |Digital outputs,parameterizable|Yes| |Short-circuitprotection|Yes| |● Response threshold, typ.|> 14.8 A| |Open-circuit detection|Yes| |● Response threshold, typ.|8 mA| |Overloadprotection|Yes| |● Response threshold, typ.|8.8 A| |Limitation of inductive shutdown voltage to|max. 1.5 V| |Switchingcapacityof the outputs|| |● with resistive load, max.|8 A| |● on lampload, max.|100 W| |Load resistance range|| |● lower limit|3 Ω| |● upper limit|2 000 Ω| |Output voltage|| |● for signal "1", min.|24 V; L+(-0.5 V)| |Output current|| |● for signal "1" rated value|8 A| |● for signal "0" residual current, max.|1.5 mA; PP-switching: max. 1.5 mA; PM-switching: max. 1 mA| |Switchingfrequency|| |● with resistive load, max.|10 Hz; Symmetrical| |● with inductive load, max.|0.1 Hz; accordingto IEC 60947-5-1, DC-13, symmetrical| |● on lampload, max.|4 Hz; Symmetrical| |Total current of the outputs|| |● Currentper channel, max.|8 A; note deratingdata in the manual| |● Currentper module, max.|8 A; note deratingdata in the manual| |Total current of the outputs(per module)|| |horizontal installation|| |— upto 40 °C, max.|8 A; note deratingdata in the manual| |— upto 50 °C, max.|6 A; note deratingdata in the manual| |— upto 60 °C, max.|4 A; note deratingdata in the manual| |— up to 70 °C, max.|4 A; note derating information in the manual; only with configured slots to the<br>left and right of the module| |Cable length|| 6AG11366PA002BC0 Page 2/5 Subject to change without notice © Copyright Siemens 5/21/2026 |● shielded, max.|1 000 m| |---|---| |● unshielded, max.|500 m| |**Interrupts/diagnostics/status information**|| |Diagnostics function|Yes; See Chapter "Alarms/diagnostic messages" in the manual| |Substitute values connectable|No| |Alarms|| |● Diagnostic alarm|Yes| |● Hardware interrupt|No| |Diagnostics indication LED|| |● RUN LED|Yes;green LED| |● ERROR LED|Yes; red LED| |● Monitoringof the supplyvoltage(PWR-LED)|Yes;green PWR LED| |● Channel status display|Yes;green LED| |● for channel diagnostics|Yes; red LED| |● for module diagnostics|Yes;green/red DIAG LED| |**Potential separation**|| |Potential separation channels|| |● between the channels|No| |● between the channels and backplane bus|Yes| |● between the channels and the power supply of the<br>electronics|No| |**Isolation**|| |Isolation tested with|707 V DC(type test)| |**Standards, approvals, certificates**|| |Suitable for safetyfunctions|Yes| |Ecological footprint|| |● environmentalproduct declaration|Yes| |Global warming potential|| |—global warming potential,(total) [CO2 eq]|88.3 kg| |— global warming potential, (during production) [CO2<br>eq]|13.1 kg| |— global warming potential, (during operation) [CO2<br>eq]|76.6 kg| |— global warming potential, (after end of life cycle)<br>[CO2 eq]|-1.37 kg| |Highest safetyclass achievable in safetymode|| |● Performance level accordingto ISO 13849-1|PLe| |● SIL acc. to IEC 61508|SIL 3| |Probabilityof failure(for service life of 20years and repair time of 100 hours)|| |— Low demand mode: PFDavg in accordance with<br>SIL2|< 2.00E-04| |— Low demand mode: PFDavg in accordance with<br>SIL3|< 2.00E-05| |— High demand/continuous mode: PFH in accordance<br>with SIL2|< 1.00E-08 1/h| |— High demand/continuous mode: PFH in accordance<br>with SIL3|< 1.00E-09 1/h| |**Ambient conditions**|| |Ambient temperature duringoperation|| |● horizontal installation, min.|-30 °C; = Tmin(incl. condensation/frost)| |● horizontal installation, max.|60 °C; = Tmax; +70 °C with spacing modules (6AG1193-6BN00-7BA0) or<br>configured slots to the left and right of the module| |● vertical installation, min.|-30 °C; = Tmin| |● vertical installation, max.|50 °C; = Tmax| |Altitude duringoperation relatingto sea level|| |● Installation altitude above sea level, max.|4 000 m; restrictions for installation altitudes > 2 000 m, see ET 200SP system<br>manual| |Relative humidity|| |● With condensation, tested in accordance with IEC 60068-<br>2-38, max.|100 %; RH incl. condensation / frost (no commissioning in bedewed state),<br>horizontal installation| |Resistance|| |Coolants and lubricants|| 6AG11366PA002BC0 Page 3/5 Subject to change without notice © Copyright Siemens 5/21/2026 |— Resistant to commercially available coolants and<br>lubricants|— Resistant to commercially available coolants and<br>lubricants|Yes; Incl. diesel and oil droplets in the air|Yes; Incl. diesel and oil droplets in the air|Yes; Incl. diesel and oil droplets in the air| |---|---|---|---|---| |Use in stationaryindustrial systems||||| |— to biologically active substances according to EN<br>60721-3-3||Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna);<br>Class 3B3 on request||| |— to chemically active substances according to EN<br>60721-3-3||Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity<br>degree 3); *||| |— to mechanically active substances according to EN<br>60721-3-3||Yes; Class 3S4 incl. sand, dust, *||| |— Against mechanical environmental conditions acc.<br>to EN 60721-3-3||Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-<br>0AA0)||| |Use on ships/at sea||||| |— to biologically active substances according to EN<br>60721-3-6||Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna)||| |— to chemically active substances according to EN<br>60721-3-6||Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity<br>degree 3); *||| |— to mechanically active substances according to EN<br>60721-3-6||Yes; Class 6S3 incl. sand, dust; *||| |— Against mechanical environmental conditions acc.<br>to EN 60721-3-6||Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-<br>0AA0)||| |Usage in industrialprocess technology||||| |— Against chemically active substances acc. to EN<br>60654-4||Yes; Class 3 (excluding trichlorethylene)||| |— Environmental conditions for process, measuring<br>and control systems acc. to ANSI/ISA-71.04||Yes; Level GX group A/B (excluding trichlorethylene; harmful gas<br>concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level<br>LC3(salt spray)and level LB3(oil)||| |Remark||||| |— Note regarding classification of environmental<br>conditions acc. to EN 60721, EN 60654-4 and<br>ANSI/ISA-71.04||* The supplied plug covers must remain in place over the unused interfaces<br>during operation!||| |Conformal coating||||| |● Coatings for printed circuit board assemblies acc. to EN<br>61086||Yes; Class 2 for high reliability||| |● Protection against foulingacc. to EN 60664-3||Yes; Type 1protection||| |● Militarytestingaccordingto MIL-I-46058C, Amendment 7||Yes; Discoloration of coating possible duringservice life||| |● Qualification and Performance of Electrical Insulating<br>Compound for Printed Board Assemblies according to IPC-<br>CC-830A||Yes; Conformal coating, Class A||| |**Dimensions**||||| |Width||20 mm||| |Height||72 mm||| |Depth||55 mm||| |**Weights**||||| |Weight, approx.||70g||| |**Classifications**||||| ||||**Version**|**Classification**| |||eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>eClass<br>ETIM<br>ETIM<br>ETIM<br>ETIM<br>IDEA<br>UNSPSC|14<br>12<br>9.1<br>9<br>8<br>7.1<br>6<br>10<br>9<br>8<br>7<br>4<br>15|27-24-26-11<br>27-24-26-11<br>27-24-26-11<br>27-24-26-11<br>27-24-26-11<br>27-24-26-11<br>27-24-26-11<br>EC002583<br>EC002583<br>EC002583<br>EC002583<br>3575<br>32-15-17-06| |**Approvals / Certificates**||||| |**General Product Approval**||||| |||**Version**|**Classification**|| |---|---|---|---|---| ||eClass|14|27-24-26-11|| ||eClass|12|27-24-26-11|| ||eClass|9.1|27-24-26-11|| ||eClass|9|27-24-26-11|| ||eClass|8|27-24-26-11|| ||eClass|7.1|27-24-26-11|| ||eClass|6|27-24-26-11|| ||ETIM|10|EC002583|| ||ETIM|9|EC002583|| ||ETIM|8|EC002583|| ||ETIM|7|EC002583|| ||IDEA|4|3575|| ||UNSPSC|15|32-15-17-06|| **Approvals / Certificates General Product Approval** 6AG11366PA002BC0 Page 4/5 Subject to change without notice © Copyright Siemens 5/21/2026 |Manufacturer Declara-<br>tion<br>~~—~~|C©C|UK<br>GA||China RoHS<br>~~—~~|TUEV<br>~~—~~|®| |---|---|---|---|---|---|---| |**General Product Approval**|||||**EMV**|**For use in hazard-**<br>**ous locations**| |HE|China RoHS|«||E§&|&B|®| |**For use in hazardous locations**||**Functional Saftey**|||**Maritime application**|| ||CCC-Ex|TUEV||TUEV||| ||~~ei~~|||||| |**Maritime application**||||||| |**last modified:**|||5/6/2026|;||| 6AG11366PA002BC0 Page 5/5 Subject to change without notice © Copyright Siemens 5/21/2026
Updated at April 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →