Image not available
Illustrative purposes only
6AG1010-1AU00-4AA0
Management System, Motor, 110-240 V, 12 Mbit/s, RS485, SIPLUS Series
⚠️ Reference pricing provided. In case of supply shortages, we will connect you with our trusted procurement partners to ensure your project's continuity.
- Manufacturer: SIEMENS
- Product type: Controller Accessories
- SVHC: To Be Advised
| Delivery and price | |
|---|---|
| Units per pack | 1 |
| Price | 659.68 € |
| Current stock | 10+ |
| Lead time | 30 days |
**6AG1010-1AU00-4AA0** **Data sheet** SIPLUS SIMOCODE pro V basic unit 2 based on 3UF7010-1AU00-0 with conformal coating, -25…+60 °C, PROFIBUS DP interface 12 Mbps, RS-485; 4 I/3 O freely parameterizable US: 110-240 V AC/DC; input for thermistor connection; monostable relay outputs; expandable by expansion modules |**product brand name**|SIRIUS| |---|---| |**product designation**|Motor management system| |**design of theproduct**|basic unit 2| |**product type designation**|SIMOCODE pro V PB| |**General technical data**|| |**certificate of suitability**|CE / RoHS| |**product function**|| |● current measurement|No| |● voltage measurement|No| |● activepower measurement|Yes| |● energymeasurement|No| |● frequencymeasurement|No| |● bus communication|Yes| |● data acquisition function|Yes| |● diagnostics function|Yes| |●passwordprotection|Yes| |● test function|Yes| |● maintenance function|Yes| |● MRRT redundancy procedure|No| |**product component**|| |● input for thermistor connection|Yes| |● digital input|Yes| |● input for analogtemperature sensors|No| |● input forground fault detection|No| |● relayoutput|Yes| |**product extension**|| |● temperature monitoringmodule|Yes| |● current measuringmodule|Yes| |● current/voltage measuringmodule|Yes| |● fail-safe digital I/O module|Yes| |●ground-fault monitoringmodule|Yes| |● decouplingmodule|Yes| |● analogI/O module|Yes| |● digital I/O module with monostable outputs|Yes| |● digital I/O module with bistable outputs|Yes| |● control unit with display|Yes| |● control unit|Yes| |**apparent power consumption**|8.3 VA| 6AG10101AU004AA0 Page 1/6 Subject to change without notice © Copyright Siemens 5/10/2026 |**consumed activepower**|3.6 W| |---|---| |insulation voltage with degree ofpollution 3 at AC rated value|300 V| |**surge voltage resistance rated value**|4 000 V| |**shock resistance**|| |**● according to IEC 60068-2-27**|15g/ 11 ms| ||| |**● vibration resistance**|1 … 6 Hz / 15 mm; 6 … 500 Hz / 2g| |**switching capacity current of the NO contacts of the relay**<br>**outputs at AC-15**|| |● at 24 V|6 A| |● at 120 V|6 A| |● at 230 V|3 A| |**switching capacity current of the NO contacts of the relay**<br>**outputs at DC-13**|| |● at 24 V|2 A| |● at 60 V|0.55 A| |● at 125 V|0.25 A| |**mechanical service life(operating cycles) typical**|10 000 000| |electrical endurance(operatingcycles)typical|100 000| |**buffering time in the event ofpower failure**|0 s| |**reference code according to IEC 81346-2**|F| |continuous current of the NO contacts of the relayoutputs|| |● at 50 °C|6 A| |● at 60 °C|5 A| |**type of input characteristic**|Type 1 in accordance with EN 61131-2| |**Substance Prohibitance(Date)**|09/13/2024| |**SVHC substance name**|Lead CAS-No. 7439-92-1| |**Net Weight**|0.369 kg| |**Electromagnetic compatibility**|| |EMC emitted interference accordingto IEC 60947-1|class A| |EMC immunityaccordingto IEC 60947-1|corresponds to degree of severity3| |**conducted interference**|| |● due to burst accordingto IEC 61000-4-4|2 kV(powerports)/ 1 kV(signalports)| |● due to conductor-earth surge accordingto IEC 61000-4-5|2 kV| |● due to conductor-conductor surge according to IEC<br>61000-4-5|1 kV| |● due to high-frequency radiation according to IEC 61000-<br>4-6|10 V| |**field-based interference according to IEC 61000-4-3**|10 V/m| |**electrostatic discharge according to IEC 61000-4-2**|6 kV contact discharge / 8 kV air discharge| |**conducted HF interference emissions according to**<br>**CISPR11**|corresponds to degree of severity A| |**field-bound HF interference emission according to CISPR11**|corresponds to degree of severityA| |**Inputs/ Outputs**|| |**product function**|| |●parameterizable inputs|Yes| |●parameterizable outputs|Yes| |**number of inputs**|4| |● for thermistor connection|1| |number of digital inputs with a common referencepotential|4| |**digital input version**|| |● type 1 acc. to IEC 61131|Yes| |**input voltage at digital input at DC**|| |● rated value|24 V| |**number of outputs**|3| |**number of semiconductor outputs**|0| |**number of outputs as contact-affected switching element**|3| |**switching behavior**|monostable| |**number of relay outputs**|3| |**type of relay outputs**|Monostable| 6AG10101AU004AA0 Page 2/6 Subject to change without notice © Copyright Siemens 5/10/2026 ||**wire length for digital signals maximum**|300 m|| |---|---|---|---| ||**wire length for thermistor connection**||| ||● with conductor cross-section = 0.5 mm² maximum|50 m|| ||● with conductor cross-section = 1.5 mm² maximum|150 m|| ||● with conductor cross-section = 2.5 mm² maximum|250 m|| ||**Protective and monitoring functions**||| ||**product function**||| ||● asymmetrydetection|Yes|| ||● blockingcurrent evaluation|Yes|| ||●power factor monitoring|Yes|| ||●ground fault detection|Yes|| ||●ground-fault monitoring|No|| ||●phase failure detection|Yes|| ||●phase sequence recognition|Yes|| ||● voltage detection|Yes|| ||● monitoringof number of start operations|Yes|| ||● overvoltage detection|Yes|| ||● overcurrent detection 1phase|Yes|| ||● undervoltage detection|Yes|| ||● undercurrent detection 1phase|Yes|| ||● activepower monitoring|Yes|| ||**product function**||| ||● current detection|Yes|| ||● overloadprotection|Yes|| ||● evaluation of thermistor motorprotection|Yes|| ||**total cold resistance number of sensors in series maximum**|1.5 kΩ|| ||**response value of thermoresistor**|3 400 ... 3 800 Ω|| ||● of the short-circuit control|9 Ω|| ||**release value of thermoresistor**|1 500 ... 1 650 Ω|| ||**Motor control functions**||| ||**product function**||| ||●parameterizable overload relay|Yes|| ||● circuit breaker control|Yes|| ||● direct start|Yes|| ||● reverse starting|Yes|| ||● star-delta circuit|Yes|| ||● star-delta reversingcircuit|Yes|| ||● Dahlander circuit|Yes|| ||● Dahlander reversingcircuit|Yes|| ||●pole-changingswitch circuit|Yes|| ||●pole-changingswitch reversingcircuit|Yes|| ||● slide control|Yes|| ||● valve control|Yes|| ||**Communication/ Protocol**||| ||**protocol is supported**||| ||● PROFIBUS DPprotocol|Yes|| ||● PROFINET IOprotocol|No|| ||● PROFIsafeprotocol|Yes|| ||● Modbus RTU|No|| ||● EtherNet/IP|No|| ||● OPC UA Server|No|| ||● LLDP|No|| ||● Address Resolution Protocol(ARP)|No|| ||● SNMP|No|| ||● HTTPS|No|| ||● NTP|No|| ||● Media RedundancyProtocol(MRP)|No|| ||**product function**||| ||● web server|No|| 6AG10101AU004AA0 Page 3/6 Subject to change without notice © Copyright Siemens 5/10/2026 |● shared device|No| |---|---| |● at the Ethernet interface Autocrossover|No| |● at the Ethernet interface Autonegotiation|No| |● at the Ethernet interface Autosensing|No| |● is supported Device Level Ring (DLR)|No| |● is supported PROFINET system redundancy (S2)|No| |● supports PROFIenergymeasured values|No| |● supports PROFIenergyshutdown|No| |**transfer rate maximum**|12 Mbit/s| |**identification & maintenance function**|| |● I&M0 - device-specific information|Yes| |● I&M1 - higher level designation/location designation|Yes| |● I&M2 - installation date|Yes| |● I&M3 - comment|Yes| |type of electrical connection of the communication interface|9-pin SUB-D socket(12 Mbit)/ screw terminal(1.5 Mbit)| |**Installation/ mounting/ dimensions**|| |**mounting position**|any| |**fastening method**|screw and snap-on mounting| |**height**|111 mm| |**width**|45 mm| |**depth**|124 mm| |**required spacing**|| |● top|40 mm| |● bottom|40 mm| |● left|0 mm| |● right|0 mm| |**Connections/ Terminals**|| |**product component removable terminal for auxiliary and**<br>**control circuit**|Yes| |**type of electrical connection**|| |● for auxiliaryand control circuit|screw-type terminals| |**type of connectable conductor cross-sections**|| |● solid|1x(0.5 ... 4.0mm²), 2x(0.5 ... 2.5 mm²)| |● finelystranded with core endprocessing|1x(0.5 ... 2.5 mm²), 2x(0.5 ... 1.5 mm²)| |● for AWG cables solid|1x(20 ... 12), 2x(20 ... 14)| |● for AWG cables stranded|1x(20 ... 14), 2x(20 ... 16)| |tighteningtorque with screw-type terminals|0.8 ... 1.2 N·m| |tighteningtorque[lbf·in]with screw-type terminals|7 ... 10.3 lbf·in| |**type of connectable conductor cross-sections for**<br>**PROFIBUS wire**|2x 0.34 mm², AWG 22| |**Ambient conditions**|| |installation altitude at height above sea level maximum|2 000 m| |**ambient temperature**|| |● duringoperation|-25 ... +60 °C| |● duringstorage|-40 ... +80 °C| |● duringtransport|-40 ... +80 °C| |**environmental category**|| |● during operation according to IEC 60721|3K6 (no formation of ice, no condensation, relative humidity 10 ... 95%), 3C3<br>(no salt mist), 3S2(sand must notget into the devices), 3M6| |● during storage according to IEC 60721|1K6 (no condensation, relative humidity 10 ... 95%), 1C2 (no salt mist), 1S2<br>(sand must notget into the devices), 1M4| |● duringtransport accordingto IEC 60721|2K2, 2C1, 2S1, 2M2| |**relative humidity**|| |● duringoperation|5 ... 95 %| |**contact rating of auxiliary contacts according to UL**|B300 / R300| |**Short-circuit protection**|| |design of short-circuit protection per output|Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-<br>breaker C char.: 1.6 A(IEC 60947-5-1)or 6 A(I_K < 500 A)| |Electrical Safety|| |**touch protection against electrical shock**|finger-safe| 6AG10101AU004AA0 Page 4/6 Subject to change without notice © Copyright Siemens 5/10/2026 |**Galvanic isolation**<br>~~|~~|**Galvanic isolation**<br>~~|~~| |---|---| |**(electrically) protective separation according to IEC 60947-1**<br>~~|~~|All circuits with protective separation (double creepage paths and clearances),<br>the information in the "Protective Separation" test report, No. A0258, must be<br>observed(link see further information)<br>~~|~~| |**design of the electrical isolation**|Protective separation in accordance with IEC 60947-1 for all circuits| |● note|Test report No. A0258 must be observed<br>(https://support.industry.siemens.com/cs/document/109748152)| |**Control circuit/ Control**<br>~~|~~|| |**product function soft starter control**<br>~~|~~|Yes<br>~~|~~| |**type of voltage of the control supply voltage**|AC/DC| |**control supply voltage at AC**|| |● at 50 Hz rated value|110 ... 240 V| |● at 60 Hz rated value|110 ... 240 V| |**control supply voltage frequency**|| |**● 1 rated value**|50 Hz| |**● 2 rated value**|60 Hz| |**relative symmetrical tolerance of the control supply voltage**<br>**frequency**|5 %| |**control supply voltage at DC rated value**|110 ... 240 V| |**operating range factor control supply voltage rated value at**<br>**DC**|| |● initial value|0.85| |● full-scale value|1.1| |**operating range factor control supply voltage rated value at**<br>**AC at 50 Hz**|| |● initial value|0.85| |● full-scale value|1.1| |**operating range factor control supply voltage rated value at**<br>**AC at 60 Hz**|| |● initial value|0.85| |● full-scale value|1.1| |**inrush currentpeak**|| |● at 240 V|15 A| |**duration of inrush currentpeak**|| |● at 240 V|1 ms| |**Approvals Certificates**<br>~~|~~|| |**General Product Approval**<br>~~|~~|| ~~|~~ **Approvals Certificates** **General Product Approval** ~~—~~ China RoHS Manufacturer Declaration - China RoHS CE ~~RC~~ **General Product ApEMV proval** ~~OO—CsSCSC—“CCSC(C‘(SCds~~ **Further information Information on the packaging** https://support.industry.siemens.com/cs/ww/en/view/109813875 **Information for data generation and storage** https://support.industry.siemens.com/cs/ww/en/view/109995012 **Information- and Downloadcenter (Catalogs, Brochures,…)** https://www.siemens.com/ic10 **Industry Mall (Online ordering system)** https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=6AG1010-1AU00-4AA0 **Cax online generator** https://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=6AG1010-1AU00-4AA0 **Service&Support (Manuals, Certificates, Characteristics, FAQs,...)** https://support.industry.siemens.com/cs/ww/en/ps/6AG1010-1AU00-4AA0 6AG10101AU004AA0 Page 5/6 Subject to change without notice © Copyright Siemens 5/10/2026 **Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)** https://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=6AG1010-1AU00-4AA0&lang=en **==> picture [419 x 238] intentionally omitted <==** **----- Start of picture text -----**<br> -F | a<br>SIEMENS<br>|<br>|<br>DEVICE Logic<br>BUS<br>GEN. FAULT SIMOCODE PRO<br>| PROFIBUS DP<br>|<br>| L<br>| 7 3 PROFIBUS DP<br>St<br>ee<br>f f ee ee [| |<br>A1 9 10 4 5 8 1 6<br>IN1 IN2 IN3 IN4 24V OUT1/2 OUT3<br>PE OUT1 OUT2 OUT3<br>A2 SPE T1 T2 2 3 7 A B DP<br>**----- End of picture text -----**<br> **last modified:** 4/5/2026 6AG10101AU004AA0 Page 6/6 Subject to change without notice © Copyright Siemens 5/10/2026
Updated at April 10, 2026
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →