67101904
INSULATED BUS BAR
- Manufacturer: WEIDMULLER
- Product type: Circuit Breaker Accessories
- For Use With:Branch R; INSULATED BUS BAR; For Use With:Branch Rated Circuit Breakers (1-Pole); Accessory Type:Bus Bar; Product Range:-
- SVHC: No SVHC (23-Jan-2024)
- For Use With: Branch Rated Circuit Breakers (1-Pole)
- Product Range: -
- Accessory Type: Bus Bar
| Delivery and price | |
|---|---|
| Units per pack | 500 |
| Price | 59.33 € |
| Current stock | 10+ |
| Lead time | 7 days |
## **9926 Series Supplemental Circuit Breakers** **Circuit Breakers 9926 Series Hydraulic Magnetic Type Single Pole** **9926 Series Double Pole** **9926 Series Triple Pole** - AC Voltages 277/480V - Trip curve 2 for general purpose applications - UL 1077 recognized - VDE approved and CE marked - Just 13 mm wide - Mounts to 35 mm DIN-rail - Factory fitted auxiliary or trip alarm - Single, double and triple pole versions ~~**Ordering Data**~~ ||~~**Type: Single Pole (up to 277 VAC)**~~|~~**Type: Single Pole (up to 277 VAC)**~~|~~**Type: Double Pole (up to 480 VAC)**~~|~~**Type: Double Pole (up to 480 VAC)**~~|~~**Type: Double Pole (up to 480 VAC)**~~|~~**Type: Triple Pole (up to 480 VAC)**~~|~~**Type: Triple Pole (up to 480 VAC)**~~|~~**Type: Triple Pole (up to 480 VAC)**~~| |---|---|---|---|---|---|---|---|---| |**Current**|||**Current**|||**Current**||| |**Ratings**|||**Rating**|||**Rating**||| |**(amps)**<br>**Part No.**||**Description**|**(amps)**|**Part No.**|**Description**|**(amps)**|**Part No.**|**Description**| |1|**9926251501**|QZ-1-13-D-2-01|1|**9926252501**|QZ-2-13-D-2-01|10|**9926253510**|QZ-3-13-D-2-10| |2|**9926251502**|QZ-1-13-D-2-02|2|**9926252502**|QZ-2-13-D-2-02|15|**9926253515**|QZ-3-13-D-2-15| |3|**9926251503**|QZ-1-13-D-2-03|4|**9926252504**|QZ-2-13-D-2-04|20|**9926253520**|QZ-3-13-D-2-20| |4|**9926251504**|QZ-1-13-D-2-04|5|**9926252505**|QZ-2-13-D-2-05|25|**9926253525**|QZ-3-13-D-2-25| |5|**9926251505**|QZ-1-13-D-2-05|6|**9926252506**|QZ-2-13-D-2-06|30|**9926253530**|QZ-3-13-D-2-30| |6|**9926251506**|QZ-1-13-D-2-06|10|**9926252510**|QZ-2-13-D-2-10|40|**9926253540**|QZ-3-13-D-2-40| |8|**9926251508**|QZ-1-13-D-2-08|15|**9926252515**|QZ-2-13-D-2-15|50|**9926253550**|QZ-3-13-D-2-50| |10|**9926251510**|QZ-1-13-D-2-10|20|**9926252520**|QZ-2-13-D-2-20|60|**9926253560**|QZ-3-13-D-2-60| |15|**9926251515**|QZ-1-13-D-2-15|25|**9926252525**|QZ-2-13-D-2-25|||| |20|**9926251520**|QZ-1-13-D-2-20|30|**9926252530**|QZ-2-13-D-2-30|||| |25|**9926251525**|QZ-1-13-D-2-25|35|**9926252535**|QZ-2-13-D-2-35|||| |35|**9926251535**|QZ-1-13-D-2-35|40|**9926252540**|QZ-2-13-D-2-40|||| |40|**9926251540**|QZ-1-13-D-2-40|50|**9926252550**|QZ-2-13-D-2-50|||| |50|**9926251550**|QZ-1-13-D-2-50|60|**9926252560**|QZ-2-13-D-2-60|||| |60|**9926251560**|QZ-1-13-D-2-60||||||| ## **Accessories** ~~**9926 Series Supplemental – dimensions in mm (in.)**~~ |~~**Type**~~|~~**Part No.**~~||||||||||**65**<br>**(2.56)**|**65**<br>**(2.56)**|**65**<br>**(2.56)**|||||||||||||||||||||| |---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---| |Bus bar(1pole,insulated 1m)<br>Bus bar(2pole,insulated 1m)<br>Bus bar(3pole,insulated 1m)<br>Bus bar end cap,1pole<br>Bus bar end cap,2pole or 3pole|**67101904**<br>**67101972**<br>**67101971**<br>**67101973**<br>**67101974**|**22.5**||**(0.86)**|||||||**60**<br>**(2.36)**|||**25.9**<br>**(0.94)**||**13**<br>**(0.51)**||||**26**<br>**(1.02)**||||||||||**39**<br>**(1.54)**||||| |Power lug,straight|**67101960**|||||||||||||||||||||||||||||||||| |Power lug,90°<br>**67101961**<br>Lock-out handle<br>**67101913**<br>~~oO~~||||||||||||||**45**<br>**(1.77)**||**92.8**<br>**(3.65)**||||li|li|li|li|li|lin|n|net|et|et|et|et|et|et|et| |||||||||||||||||||||||||||||||||||| |||||||||||||||||||||||||||||||||||| |||||||||||||||||||||||||||||||||||| |||**5.0**<br>**(0.2)**||||||||**44**<br>**(1.73)**<br>**63.8**<br>**(2.51)**<br>**73**|||||||||||**13**<br>**(0.51)**<br>aan|||||||**13**<br>**(0.51)**<br>aa|||||||| ||||||||||||**(2.87)**|||||||||||||||||||||||| |~~**Technical Data**~~||||||||||||||||~~**9926 Series–Supplemental Trip Curve**~~||||||||||||||||||| |Voltage<br>Current<br>minimum<br>maximum<br>Interruptingcapacity<br>Dielectric strength<br>Insulation resistance<br>Operatinglife<br>Operatingtemperature<br>Wire size*<br>1-15A:||277/480 VAC @ 50/60 Hz<br>0.5 A<br>60 A<br>5 kA @ 277/480 V,5 kA @ 120 V,5 kA @ 240 V<br>1500 V,50/60 Hz<br>100 MM<br>10000 mechanical operations<br>-40…+65°C<br>14 AWG min.,10 AWG max.||||||||||||||**Tripping Time**<br>Additional trip curves and<br>amp ratings are available<br>upon request.<br>**Trip Curves—Hydraulic**<br>**Magnetic Type Typical**<br>**time/current characteristics**<br>**at 30ºC**||||||||||**1000**<br>**Minutes**<br>**100**<br>**10**<br>**1**<br>**10**<br>**1**||||||||| |20-25A:<br>Torque<br>~~**Approval**~~||||||||||||||10 AWG min.<br>20 in.-lb||||||||||||**Seconds**|**0.1**|||||||| |†UL 1077 Recognized,VDE(EN 60947-2)Approved,CSA C22.2 No. 235|||CSA C22.2 No. 235,CE Marked|||||||||||||||||||||||**0.01**||||||||| **==> picture [249 x 174] intentionally omitted <==** **----- Start of picture text -----**<br> 9926 Series–Supplemental Trip Curve<br>Trip Curves—Hydraulic 1000 Operating Characteristics<br>Magnetic Type Typical Curve 2<br>time/current characteristics 100<br>at 30ºC Ambient Temperature 30°C<br>Additional trip curves and 10<br>amp ratings are available<br>upon request. 1<br>10<br>1<br>0.1<br>0.01<br>0.001<br>(%) Rated Current<br>Minutes<br>Tripping Time<br>Seconds<br>100105 130 150 200 300 400 500 1000 1500 2000 2500 3000 4000 5000<br>**----- End of picture text -----**<br> - *Wire sizes: gauges specified are the minimum allowable as per CSA and UL standards. - The 9926 circuit breakers do not have provisions for marking tags. A possible solution is to cut the adhesive SchS2 tag rail to length (approximately 20 mm on a single pole unit so the current rating remains visible or approximately 30 mm on a two pole unit).The SchS2 accepts DEK, WS and ESG 8/17 marking tags. The part number for adhesive SchS2 is **1720600000** . †cURus recognized to UL1077 and C22.2 No. 235 **52**
Updated at March 27, 2026
Weidmüller is a leading international provider of advanced solutions for electrical connectivity, power transmission, and the conditioning of signals and data in industrial environments. Recognized globally for engineering excellence, the company develops innovative components designed to optimize automation, ensure reliable power distribution, and streamline complex control panel assemblies. Our extensive portfolio of Weidmüller components is strongly centered around their industry-leading connectivity solutions. We carry a vast selection of terminal blocks to suit any application, including pluggable terminal blocks, headers and sockets, wire-to-board solutions, and rugged DIN rail terminal blocks. To support complete and organized installations, we also provide a comprehensive range of standard and fused terminal blocks, power distribution blocks, interface modules, and essential accessories like terminal block markers. Beyond core connectivity, our offering includes critical Weidmüller components for system protection and control. We supply a robust selection of circuit breakers, featuring magnetic hydraulic, thermal, and electronic variants to safeguard sensitive equipment. Additionally, our inventory encompasses dependable power relays, solid-state relays, and AC/DC converters, equipping engineers with the high-quality parts needed to build secure, efficient, and fully integrated industrial automation systems.
About Novapart
Novapart is a B2B electronic component broker specialising in stock shortages and cost reduction. We source hard-to-find parts and identify compliant alternatives across a catalogue of 410,000+ components from 500+ manufacturers.
Learn more →Stock Shortage Specialist
When a component is unavailable, discontinued or has an unacceptable lead time, we tap into our network of vetted European and Asian distributors to source what you need — without compromising on quality or traceability.
Request a quote →Compliant Alternatives
We identify pin-to-pin, electrically equivalent substitutes that meet the same certifications (RoHS, AEC-Q100, REACH) as your original specification — validated against datasheets, not just part numbers. Often at a lower cost.
BOM Analysis service →